BioHCL-SSSM: Biologically-Gated Hybrid Convolutional Linear Selective State-Space Model (Audited Clean Release)

BioHCL-SSSM (unknownBrain/BioHCL-SSSM) is a consolidated, leak-free, fully reproducible codebase and checkpoint archive for pediatric chest X-ray pneumonia classification (Kermany et al., Cell 2018; paultimothymooney/chest-xray-pneumonia, N = 5,856 JPEGs only). Every architectural module, checkpoint, CSV log, bootstrap confidence interval, McNemar significance test, and scientific disclosure in this repository has been independently audited across multi-stage verification gates.

For full methodology, calibration analysis, patient-grouping forensics, legacy artifact corrections, and complete tables, see TECHNICAL_REPORT.md.


Key Verified Results

1. Held-Out Official Kermany Test Set (N = 624, Fixed Threshold t = 0.50, Strict FP32)

Model Params (Trainable) GMACs Test Acc [95% CI] Precision Recall Specificity F1 ROC-AUC Brier ECE (10-bin)
Student BioHCL-SSSM (256-d, KD) 8,340,554 3.429 87.50% [84.78, 90.06] 83.62% 99.49% 67.52% 0.9087 0.9391 0.1218 0.1229
Baseline ResNet-50 23,512,130 4.132 84.29%* [81.41, 87.18] 80.17% 99.49% 58.97% 0.8879 0.9605 0.1481 0.1465
Ablation: Single-CNN Branch 1,249,822 1.132 83.81% [80.93, 86.70] 84.99% 90.00% 73.50% 0.8742 0.9116 0.1179 0.0467
Ablation: No Bio-Prior 8,340,554 3.429 82.37% [79.33, 85.42] 78.11% 99.74% 53.42% 0.8761 0.9506 0.1701 0.1681
Ablation: No Positional Encoding 8,340,554 3.417 81.09% [77.88, 84.13] 76.88% 99.74% 50.00% 0.8683 0.9701 0.1875 0.1879

**Baseline_ResNet50 scores 84.29% (526/624) in strict FP32 and 84.46% (527/624) under torch.amp.autocast('cuda') due to 1 borderline image (p=0.5036 FP32). Paired McNemar exact test (Student vs ResNet-50 FP32): Ξ”Acc = +3.21% [+1.44%, +4.97%], 27 vs 7 discordant pairs, p = 0.000821.*

2. Clean Patient-Grouped 5-Fold Cross-Validation (N = 5,232, 2,861 Patient/MD5 Groups, Direct 256-d L=2)

Using Union-Find patient + exact MD5 grouping BEFORE StratifiedGroupKFold (0 patient overlap, 0 MD5 overlap per fold; official test/ untouched):

  • Mean Β± SD across 5 folds: Accuracy 99.35% Β± 0.26%, Macro-F1 0.9915 Β± 0.0032, F1 0.9956 Β± 0.0017, Specificity 99.11% Β± 0.61%, Recall 99.43% Β± 0.21%, ROC-AUC 0.9994 Β± 0.0004, Brier 0.0064 Β± 0.0025, ECE 0.0065 Β± 0.0027.
  • Pooled Out-Of-Fold (N = 5,232): Accuracy 99.35% [99.12%, 99.56%], TN = 1,337, FP = 12, FN = 22, TP = 3,861, ROC-AUC 0.9991, Brier 0.0064, ECE 0.0061.

Central Generalization Gap Finding: BioHCL-SSSM achieves 99.35% Β± 0.26% internal patient-grouped CV accuracy (N=5,232), demonstrating strong within-cohort generalization, while external transfer to the official held-out Kermany test set (N=624) yields 87.50% (KD Student) and 80.61%–85.90% across single-fold Ξ»_phys=0.0 direct runs (78.69%–85.90% across all 11 variants including regularized sweeps) β€” reflecting documented distribution shift (train+val 74.1% vs test 62.5% Pneumonia, acquisition/spectrum differences). We never conflate internal CV with external generalization.

3. Unified Controlled 256-d Fold-0 Ablation Highlights (--epochs 30 --patience 8, 11 Variants)

All 11 variants converged without single-class collapse (WeightedRandomSampler never stacked with weighted losses):

  • SSSM vs. Tuned 8-Head MHSA: SSSM_L2_Ref (8.34M params: 82.69% Test Acc [79.65, 85.58], 0.9588 AUC) vs. MHSA_L2_8Heads (8.56M params: 83.01% Test Acc [79.97, 85.90], 0.9482 AUC) perform within sampling noise on Fold 0 β€” no superiority claimed over MHSA without multi-fold testing.
  • Depth & Skip Connections (Single-Fold): Depth_SSSM_L4 reached 85.26% (0.9708 AUC) and Ablation_NoSkip_L2 reached 84.62% (0.9759 AUC), outperforming SSSM_L2_Ref (82.69%) on Fold 0 β€” reported transparently as single-fold observations requiring multi-fold validation.
  • Class-Imbalance Strategy: Loss_WeightedCE_Uniform (uniform shuffle + inverse class weights, no sampler) achieved the highest Fold-0 test accuracy at 85.90% (0.8981 F1, 63.25% Specificity, 0.9384 AUC).
  • Batch Feature-Consistency Regularizer (Ξ»_phys): Sweeping Ξ»_phys ∈ {0.0, 0.01, 0.05, 0.20} kept high internal Val accuracy (98.8%–99.1%) while degrading external Test ROC-AUC sharply from 0.9588 (Ξ»=0.0) β†’ 0.8514 (Ξ»=0.01) β†’ 0.7233 (Ξ»=0.05) and 0.8867 (Ξ»=0.20), empirically validating why Ξ»_phys = 0.0 is used in all clean configurations.

Visualizations

Figure Description
Confusion Matrices Side-by-side held-out test confusion matrices (N = 624, fixed t = 0.50) for all 5 verified Aug-12 models.
ROC & Calibration Ranking ROC-AUC vs. top-label reliability calibration explaining why Student KD wins at t = 0.50.
Patient-Grouped CV Per-fold accuracy/F1/AUC across all 5 patient-grouped folds + pooled N = 5,232 OOF confusion matrix.
Clean 256-d Ablations Complete 11-variant Fold-0 test accuracy & 95% CI comparison at fixed t = 0.50.

Repository Structure

BioHCL-SSSM/
β”œβ”€β”€ README.md                              # Overview, verified metrics, quick-start
β”œβ”€β”€ TECHNICAL_REPORT.md                    # Full audit report, Old-vs-New comparison & disclosures D1–D7
β”œβ”€β”€ requirements.txt                       # Clean Python dependencies
β”œβ”€β”€ src/
β”‚   β”œβ”€β”€ models/biohcl_sssm.py              # Single canonical BioHCLSSSM (`256-d`, `L=2` default) + MHSA/ResNet50
β”‚   β”œβ”€β”€ data/dataset.py                    # Union-Find patient + MD5 grouping + StratifiedGroupKFold
β”‚   β”œβ”€β”€ losses/losses.py                   # FP32 CE, Weighted CE, Focal (Ξ³=2), & documented consistency term
β”‚   β”œβ”€β”€ training/trainer.py                # Shared AdamW + warmup-cosine loop, collapse guard & FP32 eval
β”‚   └── utils/metrics.py                   # Acc/Prec/Rec/Spec/F1/AUC/PR-AUC/Brier/ECE, 10k bootstrap, McNemar
β”œβ”€β”€ scripts/
β”‚   β”œβ”€β”€ smoke_check.py                     # Architecture, forward/backward, zero-leakage & zero-secret check
β”‚   β”œβ”€β”€ evaluate_single_checkpoint.py      # Standalone FP32 checkpoint evaluator CLI
β”‚   β”œβ”€β”€ run_phase0_eval.py                 # Reproduce Priority 1 official test evaluation + McNemar tests
β”‚   β”œβ”€β”€ run_phase1_groupkfold.py           # Reproduce Priority 3 5-fold patient-grouped CV
β”‚   β”œβ”€β”€ run_phase1_ablations.py            # Reproduce Priority 4 11-variant 256-d ablation suite
β”‚   └── generate_figures.py                # Regenerate all 4 300-DPI figures from CSV/NPZ outputs
β”œβ”€β”€ results/                               # Audited CSVs, JSON summaries, McNemar results & NPZ probabilities
β”œβ”€β”€ figures/                               # 300-DPI PNG figures
└── checkpoints/                           # 21 clean verified `.pt` state_dicts + checkpoints/README.md

Quick Start & Reproducibility

pip install -r requirements.txt

# 1. Verify package integrity, zero secrets, zero thop buffers, and patient/MD5 CV isolation
python scripts/smoke_check.py

# 2. Evaluate the verified Aug-12 Student BioHCL-SSSM checkpoint on official Kermany test (N=624)
python scripts/evaluate_single_checkpoint.py \
  --checkpoint checkpoints/aug12_verified/biohcl_sssm_student_256d.pt \
  --data-dir /path/to/chest_xray

# 3. Reproduce full Priority 1 table + exact McNemar test + Brier/ECE
python scripts/run_phase0_eval.py --data-dir /path/to/chest_xray

# 4. Reproduce 5-fold patient-grouped CV (official test/ untouched)
python scripts/run_phase1_groupkfold.py --data-dir /path/to/chest_xray

# 5. Reproduce the unified 11-variant 256-d ablation suite on Fold 0
python scripts/run_phase1_ablations.py --data-dir /path/to/chest_xray --epochs 30 --patience 8

Mandatory Scientific Scope & Limitations

  • Single-Dataset Provenance: All experiments in this repository were executed strictly on the Kermany Pediatric Chest X-Ray cohort (ages 1–5, Guangzhou Women and Children's Medical Center). Results do not establish generalization to adult populations or other modalities (no Brain MRI, RSNA, or NIH runs were executed).
  • Kermany Dataset Artifacts: Official test/PNEUMONIA/ restarts person numbering independently of train/; patient tokens are disambiguated by split prefix ({split}_person_{id}). One exact-byte duplicate pair exists inside official test/NORMAL (NORMAL2-IM-0095-0001.jpeg == NORMAL2-IM-0096-0001.jpeg) and is retained unmodified inside N = 624 for benchmark comparability.
  • Architecture & Regularizer Transparency: ResidualConnector projection/norm layers (132,608 params inside the 8,340,554 trainable total) exist inside state_dict for checkpoint compatibility while BioHCLSSSM.forward() reads skip_step directly. The auxiliary features.roll(1) L2 penalty is accurately documented as a Batch Feature-Consistency Regularizer (disabled at Ξ»_phys = 0.0), not a biophysical PDE loss.
  • Clinical Sensitivity vs. Specificity: At fixed t = 0.50, all models prioritize Pneumonia Sensitivity (β‰₯ 90% / 99.49%) with moderate external Specificity (44%–73.5%). Clinical deployment would require threshold calibration on a dedicated held-out validation calibration subset.
Downloads last month

-

Downloads are not tracked for this model. How to track
Inference Providers NEW