Dataset Viewer
The dataset could not be loaded because the splits use different data file formats, which is not supported. Read more about the splits configuration. Click for more details.
Couldn't infer the same data file format for all splits. Got {NamedSplit('validation'): ('json', {}), NamedSplit('test'): ('csv', {})}
Error code:   FileFormatMismatchBetweenSplitsError

Need help to make the dataset viewer work? Make sure to review how to configure the dataset viewer, and open a discussion for direct support.

ODL-EGO S1 | Stereo Calibration Validation

REAL-WORLD DATA ENGINEERING · TECHNICAL EVIDENCE SERIES

Origin Data Lab Stereo Vision Physical AI

Evaluation Artifacts Documentation License Version

Stereo calibration consistency · Epipolar geometry · Capture-mode sensitivity

Explore GitHub Evidence · Read Technical Field Note · Origin Data Lab


Technical evaluation artifacts · Origin Data Lab · Field Note #04 · October 2026

Scope: This is a compact calibration evaluation artifact collection, not a downloadable video dataset, benchmark leaderboard, or production-certified calibration. The data describes a particular ODL-EGO S1 sample and sensor configuration.

Technical source & inspection tools (GitHub) · Origin Data Lab · Contact

Key results at a glance

0.408 px 1.685 px 29 pairs 19,386 matches
Median angular epipolar error p90 angular epipolar error Sampled stereo pairs Unfiltered matches

Reported metrics for the specified evaluated configuration, not generalized camera accuracy or production certification.

At a glance

Evaluation item Reported result Interpretation
Capture mode evaluated 1600 × 1200, 30 fps Mode-specific results
Original Kalibr solution 800 × 600 Calibration adapted to the evaluated mode
Stereo pairs sampled 29 Evaluation sample, not a full deployment survey
Unfiltered stereo matches 19,386 No RANSAC filtering reported
Angular epipolar error, median 0.408 px Angular metric expressed in center-equivalent pixels
Angular epipolar error, p90 1.685 px Distribution has a nontrivial tail
Held-out median, supplied rotation 0.399 px As reported by source validation
Held-out median, after fitted 3-DoF correction 0.374 px Fitted on evaluation setup; not a new certified calibration

Important: The 0.408 px angular metric is not interchangeable with rectified vertical residual or a metric depth error. A mode-mismatched 16:9 comparison in Field Note #04 reports a different error distribution; do not combine measurements from different capture configurations.


Visual evaluation

1. Epipolar consistency across the image

Spatial distribution of angular epipolar error

Figure: spatial error pattern for the tested stereo configuration. Edge and field-angle behavior must be evaluated separately from the overall median.

2. Capture-mode matching matters

Matched versus mismatched calibration modes

Figure: a comparison of matching and nonmatching sensor modes. This is not an estimate of generic camera accuracy.

3. Sensitivity to small rotation changes

Rotation sensitivity

Figure: sensitivity of the reported metric to deliberately perturbed stereo rotation.

4. Different error metrics versus field angle

Metrics versus field angle

Figure: angular epipolar error and rectified residuals are different quantities.

5. Fisheye inverse-model behavior

Fisheye undistortion roundtrip

Figure: tested OpenCV fisheye unprojection behavior in the specified setup; it is not a universal claim about library correctness.


Downloadable evaluation artifacts

Folder Contents
03_Validation/ Original JSON summaries and source PNG evaluation figure
figures/ Five WebP figures for review and citation
00_Report/ Full calibration validation report (PDF)
data/ Compact CSV table derived from the original JSON summaries
SOURCE_AND_LIMITATIONS.md Provenance, metric definitions, cautions

The original Kalibr YAML outputs, Python inspection scripts, and source-package checksum manifest are maintained in the GitHub repository. This Hugging Face release is intentionally organized for discovery, inspection, and evaluation.


What this release does not validate

  • Metric stereo depth accuracy or independently verified baseline accuracy.
  • Camera-to-IMU extrinsics or timing to production tolerances.
  • Generalization to other lenses, resolutions, crops, devices, or capture modes.
  • Universal rectification quality or a universal bug in OpenCV.
  • End-to-end independent reproduction of the original calibration run from raw recordings.

The values and figures are published as supplied in the accompanying technical package. Packaging them here is not an independent rerun or certification.

Technical field notes

These article links are intended public URLs; confirm site deployment before relying on them.

Rights and permitted use

Public visibility does not grant an open-data license. See LICENSE.md. For redistribution, incorporation into products, training, or commercial use, obtain written permission from Origin Data Lab: contact@origindatalab.io.

Suggested citation: Origin Data Lab (2026). ODL-EGO S1 Stereo Calibration Validation Artifacts, v1.0. Technical Field Note #04. GitHub: https://github.com/origin-data-lab/stereo-calibration-validation