New MultiView recordings
Nineteen sessions (7–100 min) recorded 2026-11-03 to 2026-11-08: up to six synchronized Basler daA1280-54uc colour cameras (1280×960, 24 fps, software-triggered) with simultaneous 128-channel EMG from an Intan RHX recording controller (2 kHz).
| Session | Length | Frames / camera | Rounds with all cameras | Calibration recorded |
|---|---|---|---|---|
subject02_session01 |
67.9 min | ~97,730 | 97,720 | 16:08 (calib_20261103_1608) |
subject03_session01 |
61.1 min | ~87,925 | 87,919 | 17:43 (calib_20261103_1743) |
subject05_session01 |
70.5 min | ~101,510 | 101,485 | 19:06 (calib_20261103_1906) |
subject06_session01 |
35.2 min | ~50,709 | 50,703 | 2026-11-05 13:27 (calib_20261105_1327) |
subject07_session01 |
65.4 min | ~94,222 | 94,197 | 2026-11-05 14:54 (calib_20261105_1454) |
subject07_session02 |
70.6 min | ~101,651 | 101,639 | 2026-11-05 16:26 (calib_20261105_1626) |
subject09_session01 |
12.8 min | ~17,830–18,390 | 17,825 | 2026-11-06 11:19 (calib_20261106_1119) |
subject09_session02 |
19.8 min | ~28,533 | 28,532 (5 cameras) | 2026-11-06 11:19 (calib_20261106_1119) |
subject10_session01 |
60.6 min | ~87,236 | 87,223 | 2026-11-06 13:14 (calib_20261106_1314) |
subject11_session01 |
22.7 min | ~32,592 | 32,590 | 2026-11-06 14:42 (calib_20261106_1442) |
subject11_session02 |
22.2 min | ~31,988 | 31,981 | 2026-11-06 15:09 (calib_20261106_1509) |
subject12_session02 |
52.4 min | ~75,429 | 75,407 | 2026-11-06 16:11 (calib_20261106_1611) |
subject13_session01 |
7.4 min | ~10,649 | 10,647 | 2026-11-06 17:24 (calib_20261106_1724) |
subject13_session02 |
52.0 min | ~74,824 | 74,809 | 2026-11-06 17:24 (calib_20261106_1724) |
subject14_session01 |
23.5 min | ~33,782 (cam2 33,616) | 33,616 | 2026-11-07 14:19 (calib_20261107_1419) |
subject14_session02 |
49.5 min | ~71,211 | 71,193 | 2026-11-07 14:19 (calib_20261107_1419) |
subject15_session01 |
67.3 min | ~96,928 | 96,890 | 2026-11-07 16:17 (calib_20261107_1617) |
subject16_session01 |
100.0 min | ~143,997 | 143,927 | 2026-11-08 20:22 (calib_20261108_2022) |
subject16_session03 |
33.3 min | ~47,843 | 47,825 | 2026-11-08 20:22 (calib_20261108_2022) |
Layout
<session>/
session.json capture settings, per-camera stats, clock anchor, EMG summary
triggers.csv every trigger: seq, host_trigger_ns
synced_frames.csv one row per trigger: n_cameras + each camera's image path
cam<i>_<serial>_timestamps.csv one row per frame: frame_idx, image, trigger_seq,
device timestamp, device timestamp mapped to host clock, ...
frames/cam<i>_<serial>/*.tar the JPEG frames, 10,000 per tar (see below)
calibration/ the calibration used for this session
intrinsics/camera_<i>.npz K, dist (OpenCV 5-coefficient), image_size, serial
extrinsics/camera_poses.json R, t per camera: X_cam = R @ X_world + t, metres,
world = cam0 frame
calibration_summary.json quality report
emg.h5 EMG on the host clock, with per-frame index
emg_frame_index.csv EMG sample range for every camera trigger
timing_v2/ corrected timing -- use instead of the above (see below)
emg_frames.bin, emg_blocks.csv raw EMG blocks as streamed
intan_rhd/ Intan's own .rhd recording
Corrected timing: timing_v2/ (use this)
Every session also has a timing_v2/ folder with refitted clock timing. Use it in place of
the original timing files. The original post-pass mapped the Intan sample counter and each
camera's clock onto host time with one straight line per session. When the host clock changed
rate mid-session, the line could not follow, and EMG-to-video alignment drifted:
| Worst EMG-to-video error in the original files | Sessions |
|---|---|
| 17.5 ms | subject16_session01 |
| 7.0 ms | subject10_session01 |
| 4.5 ms | subject07_session02 |
| 3.5 ms | subject13_session02 |
| 1.5–2 ms | subject07_session01, subject12_session02, subject16_session03 |
| ≤ 1 ms | all others |
timing_v2/ refits both clocks with a correction re-estimated every 60 s. The EMG and camera
corrections, fitted independently, agree to ~0.3 ms rms.
emg_frame_index.csvreplacesemg_frame_index.csv.emg_timestamps.h5(host_ns,timestamps, one row per row ofemg.h5) replacesemg.h5'shost_nsandtimestamps. The EMG samples are unchanged.cam<i>_<serial>_timestamps.csvreplaces the camera timestamp CSVs; onlydev_ts_host_nsdiffers.timing_v2.jsonholds the fits and how much each quantity moved.
Restoring the frames
Each tar holds paths relative to the session folder (cam0_22865794/000/frame_000000.jpg),
so extracting in the session folder restores the layout that synced_frames.csv and the
timestamp CSVs refer to:
cd subject03_session01
for t in frames/*/*.tar; do tar -xf "$t"; done
Frames are stored as <camera>/<NNN>/frame_<frame_idx>.jpg (1,000 per folder). The
trigger each frame answers is in the trigger_seq column; frames with the same
trigger_seq were exposed together (median cross-camera spread ~0.15 ms).
Cameras
| Index | Serial |
|---|---|
| cam0 | 22865794 |
| cam1 | 22865834 |
| cam2 | 22873121 |
| cam3 | 22873159 |
| cam4 | 24702671 |
| cam5 | 24702677 |
Images are upright (cameras flipped in hardware).
Camera indices follow the cameras present in each session. Always use the serial in the
folder name (cam<i>_<serial>), not the index, when matching across sessions:
subject09_session02 has no 24702677 (cam0–cam4 as in the table above).
Known issues
subject02_session01: cam4 (24702671) was physically moved at ~11:03 into the session (trigger 15912). Its calibration is valid only before that; drop cam4 afterwards.subject05_session01: by the next calibration (20:56) cam5 (24702677) had shifted relative to the other cameras (~8 px); when this happened could not be determined from the video. cam3 also moved, but only after the session ended.subject13_session02: cam0 (22865794) was bumped at trigger 59749 (2489.8 s, ~92 px shift); disregard cam0 frames withtrigger_seq >= 59749. Details insubject13_session02/NOTES.mdandexclusions.json. The other cameras did not move.subject09_session01: cam5 (24702677) was on a faulty USB port: ~560 missed triggers and some late exposures (up to ~20 ms), and the camera dropped out near the end. Checkcam5_24702677_timestamps.csv(dev_ts_host_nsvshost_trigger_ns) and drop late cam5 frames.subject14_session01: cam2 (22873121) skipped 164 triggers and hung at 1407 s (missing for the last ~7 s); ~35 cam2 frames started more than 5 ms late (up to 21 ms). Drop late cam2 frames by comparingdev_ts_host_nswithhost_trigger_nsincam2_22873121_timestamps.csv.subject09_session02: recorded with 5 cameras (24702677 unplugged).- A handful of frames per camera were lost to USB hiccups (listed as missing in
synced_frames.csv,n_cameras < 6).