ConvNeXt V2-tiny CheXpert (seed 1)

A five-finding chest radiograph classifier: facebook/convnextv2-tiny-22k-384 fine-tuned end to end on CheXpert. It is one of the two subject models audited in "Show Me What You Don't Know: Efficient Sampling from Invariant Sets for Model Validation" (Rousselot, Wendebourg and Köthe, 2026), where it is not the end product but the thing being examined — the paper samples from its fibers, the sets of images it maps to the same representation.

This is one of an identically trained pair. convnext-chexpert-seed2 is the same recipe under a different random seed. The paper audits both to ask whether two models that differ only in training randomness end up sharing their invariances (Figure 18) — so if you want one classifier, take this one; if you want to reproduce that experiment, you need both.

Labels

Multi-label, five CheXpert competition findings, in this order:

["Atelectasis", "Cardiomegaly", "Consolidation", "Edema", "Pleural Effusion"]

The model outputs five raw logits. In the paper, φ(x) is that logit vector, and the fiber loss is the per-class probability distance of Appendix B.4.

Loading it

A standard transformers image classifier:

from transformers import AutoModelForImageClassification

model = AutoModelForImageClassification.from_pretrained(
    "RussellALA/convnext-chexpert-seed1").eval()
logits = model(pixel_values).logits            # (B, 5)

Or through the paper's subject-model wrapper, which takes a normalised 1-channel batch and repeats the channel to three:

from experiments.chexpert.subject_models import ConvNextClassfierSubjectModel

model = ConvNextClassfierSubjectModel("RussellALA/convnext-chexpert-seed1",
                                      n_channels=1).eval()

Training

Trained with notebooks/chexpert_classifier.ipynb in the repository above.

Base facebook/convnextv2-tiny-22k-384, fine-tuned end to end
Data CheXpert v1.0-small, frontal views only
Split train.csv divided by StratifiedGroupKFold grouped on PatientID, so no patient crosses the split; valid.csv (202 frontal studies) held out as the test set
Resolution 384 × 384
Augmentation Rotate(15°), horizontal flip
Normalisation Per-channel ImageNet statistics, mean (0.485, 0.456, 0.406), std (0.229, 0.224, 0.225)
Loss Masked Asymmetric Loss (Ridnik et al., 2020), gamma_neg=3, with uncertain (-1) labels masked out rather than imputed
Optimiser AdamW, lr 1e-3, weight decay 0.02, cosine schedule, 1600 warmup steps
Epochs 3, batch size 16, best checkpoint by validation loss

Missing labels are filled with 0; uncertain labels are excluded from the loss.

⚠️ Input convention

Two conventions are in play and they are not interchangeable:

  • As trained (and what you should use for ordinary inference): 384×384, RGB, per-channel ImageNet normalisation.
  • As audited in the paper: the invariance-auditing pipeline normalises the 1-channel image with grayscale-collapsed statistics — the mean of the per-channel values, 0.4490 / 0.2260 — and then repeats that one channel three times. renormalize_grayscale in experiments/chexpert/subject_models.py converts between the two, and is deliberately never called.

Measured against the logits the paper's runs stored, the per-channel convention sits 1.19% away from this model as a probability distance, where the repeat-only convention sits 0.0016% away. The BiomedCLIP companion is twenty times more sensitive, at 25.17% against 0.0001%.

Evaluation

Validation used label-wise AUROC, plus exact-match, specificity and Hamming distance (torchmetrics multilabel). The paper reports this model's fiber loss and nearest-neighbour baseline in Table 5, and its cross-model agreement with BiomedCLIP in Figure 8 — measurements of what the model treats as equivalent, not of its diagnostic accuracy.

Intended use and limitations

This is a research artifact, published so that the paper's invariance audit can be reproduced. It is not a diagnostic tool and must not be used for clinical decisions, or on patients.

Known limitations:

  • Trained on a single institution's data (Stanford Hospital) at low resolution, on five findings out of CheXpert's fourteen.
  • The paper's own finding is the sharpest limitation: the model assigns the same representation to images that differ in ways a radiologist would not consider equivalent. That is what the fiber samples show.
  • Uncertain labels were masked, so the model never learned to express uncertainty; its outputs are not calibrated.
  • Inherits whatever demographic and acquisition biases are in CheXpert.

Licence and data terms

The weights are derived from CheXpert, which is distributed under the Stanford University Dataset Research Use Agreement: research use only, non-commercial. By using this model you accept those terms as they extend to derivatives. The CheXpert images themselves are not redistributed here or in the paper's repository — request them from Stanford.

Citation

@article{rousselot2026show,
  title={Show Me What You Don't Know: Efficient Sampling from Invariant Sets for Model Validation},
  author={Rousselot, Armand and Wendebourg, Joran and K{\"o}the, Ullrich},
  journal={arXiv preprint arXiv:2603.21782},
  year={2026}
}