Medical-Image-Segmentation
Collection
5 items • Updated
Two-stage 3D nodule segmentation on lung-cropped CT at native 1 mm resolution. Trained on 128^3 nodule-biased patches (Focal Tversky + weighted CE, nodule CE weight 10), inference via 128^3 sliding windows (overlap 0.5, Gaussian blending).
Test split of the released split.csv (308 series): nodule Dice (micro) 0.6005, precision 0.5104, recall 0.7291; instance recall 0.8758, instance precision 0.0780.
Files: model.pth (weights-only state dict) + config.yaml (full training
configuration). Training and evaluation code, lung bounding boxes and reports:
szegedai/nodule-segmentation-baselines.