accepted_inspectors string | exemptions string | governing_body string | id string | low_pressure_boiler_interval string | power_boiler_interval string | pressure_vessel_interval string | source string | source_quote string | state string | statute_citation string | url string | verified_fields list | also_reported list | disagreements list |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
State deputy inspectors; insurance company inspectors holding a Certificate of Competency issued by the Secretary of Labor | Boilers and pressure vessels under federal control or under regulations of Title 49 of the Code of Federal Regulations, Parts 192 and 193; pressure vessels used for transportation and storage of compressed liquefied gases per US DOT specs; pressure vessels on vehicles under other state or federal authorities; air tanks... | Alabama Department of Workforce | alabama | one biennial inspection with an internal inspection every four years | one annual internal and external inspection | one biennial inspection with an internal inspection at the discretion of the inspector | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Wiggins, Jr., Director of Inspections, Chief Inspector Alabama Department of Workforce 50 N Ripley Street Montgomery, AL 36131 Telephone — 334.956.7412 Email — edward.wiggins@workforce.alabama.gov Fax ­— 334.956.7405 EMPOWERMENT Boiler Board: Yes. (Contact above official for more information.) DAT... | Alabama | Alabama State Statutes, Title 25. Labor, Chapter 12. The Boiler and Pressure Vessel Safety Act , Sections 25.12.1 through 25.12.22. | https://referencesource.org/boiler-inspection-requirements-by-state/alabama/ | [
"governing_body",
"state",
"statute_citation"
] | null | null |
Department inspector; insurance company inspectors (inspections accepted in lieu of department inspector); special inspector commission may be issued to insurance inspectors or owner/user inspectors holding a Certificate of Competency or commission issued by a state that has adopted the ASME Code | Boilers and unfired pressure vessels under federal regulation; unfired pressure vessels meeting US DOT requirements for shipment; air tanks on vehicles under other state authorities; air tanks on railroad rights-of-way; unfired pressure vessels of 5 cubic feet or less or inside diameter not exceeding 6 inches; unfired ... | Alaska Department of Labor and Workforce Development, Mechanical Inspection Section | alaska | certificate inspection every two years with an internal inspection every four years if construction permits | certificate inspection annually; external inspection while under pressure, or internal inspection as warranted | inspected internally and externally at intervals set by the Department of Labor and Workforce Development | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Alaska Statutes Title 18, Chapter 60 Boilers and Unfired Pressure Vessels 18.60.180 RULES FOR CONSTRUCTION AND STAMPING Construction: | Alaska | Alaska Statutes Title 18, Chapter 60 Boilers and Unfired Pressure Vessels 18.60.180 | https://referencesource.org/boiler-inspection-requirements-by-state/alaska/ | [
"state",
"statute_citation"
] | null | null |
Third party inspectors employed by National Board or ASME accredited companies and issued a special inspection certificate by the chief boiler inspector, accepted per A.R.S. 23-485 | Boilers, lined hot water heaters and pressure vessels regulated by the US government; boilers, lined hot water heaters and pressure vessels located in private residences, or apartment complexes less than six units; boilers, lined hot water heaters and pressure vessels operated on Indian reservations; lined (potable) ho... | Industrial Commission of Arizona, Department of Safety and Health, Boiler & Elevator Safety Sections | arizona | certificate inspection every two years; internal inspection where construction permits | annual internal certificate inspection and an external inspection while under operating conditions; triennial (36-month) internal inspection and annual external inspection when fully attended by qualified attendants per Arizona Boiler Rule, R20-5-408(C) | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Arizona Revised Statutes, Title 23. Labor, Article 11. Arizona Boiler Act , Sections 471 through 488. RULES FOR CONSTRUCTION AND STAMPING Construction: | Arizona | Arizona Revised Statutes, Title 23. Labor, Article 11. Arizona Boiler Act , Sections 471 through 488. | https://referencesource.org/boiler-inspection-requirements-by-state/arizona/ | [
"state",
"statute_citation"
] | null | null |
Insurance company inspectors commissioned by the department (accepted in lieu of department inspector, except field inspections of anhydrous ammonia vessels); inspectors holding a National Board commission employed by insurance company, owner user organization or the State of Arkansas | Air tanks of 12 gallons or less containing 150 psi or less; boilers and unfired pressure vessels under Interstate Commerce Commission inspection regulations; boilers and unfired pressure vessels for domestic purposes in private dwellings and apartment houses of eight or fewer apartments; unfired pressure vessels with M... | Arkansas Department of Labor & Licensing, Boiler Inspection Division | arkansas | one internal inspection every three years | one annual internal inspection; one annual external inspection | every two years | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Boilers and fired pressure vessels: One annual internal inspection. One annual external inspection. Unfired pressure vessels every two years. Boilers, gas, and electric water heaters located in schools, nursing homes, day-care centers, and hospitals: Once annually. Low-pressure steam-heating boilers: One internal inspe... | Arkansas | Arkansas Code 20-23-101et seq.; and 5-64-1301 through 1303. | https://referencesource.org/boiler-inspection-requirements-by-state/arkansas/ | [
"low_pressure_boiler_interval",
"pressure_vessel_interval"
] | null | null |
Inspectors holding a valid Certificate of Competency issued by the division (accepted in lieu of Pressure Vessel Unit engineer); owner/user organization inspectors whose inservice programs have been approved by the Pressure Vessel Unit | Boilers and pressure vessels under federal inspection and control or exempted by the labor code; boilers on automobiles and road motor vehicles; boilers and unfired pressure vessels used in household service; air pressure tanks under US DOT, Public Utilities Commission, or Highway Patrol jurisdiction; unfired pressure ... | Department of Industrial Relations, Division of Industrial Safety and Health | california | null | one annual internal and external inspection (Exception: boilers in turbo-electric plants furnishing steam to a single turbine inspected internally at least once each 18 months); Title 8, Section 770 allows fired boilers to go up to three years without internal inspection after application and acceptance by the Pressure... | one inspection at least every three years for portable air tanks and five years for all other air tanks; LPG tanks on schedule by usage type (3–5 years) | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | California Code of Regulations, Title 8. Chapter 4. Division of Industrial Safety, Subchapter 1. Unfired Pressure Vessel Safety , Sections 450 through 560; Subchapter 2. Boiler and Fired Pressure Vessel Safety , Sections 750 through 797. RULES FOR CONSTRUCTION AND STAMPING Construction: | California | California Code of Regulations, Title 8. Chapter 4. Division of Industrial Safety, Subchapter 1. Unfired Pressure Vessel Safety , Sections 450 through 560; Subchapter 2. Boiler and Fired Pressure Vessel Safety , Sections 750 through 797. | https://referencesource.org/boiler-inspection-requirements-by-state/california/ | [
"state",
"statute_citation"
] | null | null |
city-employed inspectors | null | The City of Chicago Boiler Bureau | chicago | periodic external inspections and internal inspections at the inspector's discretion | periodic internal and external inspections | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | The City of Chicago Boiler Bureau administers inspections under the Municipal Code of Chicago, Title 4, Chapter 344. Authorized inspector types: Chicago accepts only city-employed inspectors and does not recognize insurance company inspections. Inspection frequency: High-pressure boilers require periodic internal and e... | Chicago | Municipal Code of Chicago, Title 4, Chapter 344 | https://referencesource.org/boiler-inspection-requirements-by-state/chicago/ | [
"accepted_inspectors",
"governing_body",
"power_boiler_interval",
"state",
"statute_citation"
] | null | null |
Insurance company inspectors commissioned by the division (accepted in lieu of division inspector, except first certificate inspection of new or reinstalled boiler must be by division inspector); owner/user inspection organizations approved by the director | Boilers owned or operated by the federal government; locomotive boilers of carriers subject to Federal Locomotive Inspection Act; boilers in private residences and apartment houses with fewer than six families; boilers in cities where city boiler inspectors and codes are comparable to state program; service and domesti... | Department of Labor and Employment, Division of Oil and Public Safety - Boiler Section | colorado | certificate inspection biennially; external or internal inspection | certificate inspection annually; internal inspection annually (may be extended to triennially with prior approval from the Boiler Division) | ASME Code vessels bearing ASME Code stamping considered suitable; non-ASME Code pressure vessel must be certified by the Boiler Inspection Section | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Power boilers and high-temperature water boilers shall receive a certificate inspection annually. Such boilers where construction permits shall also receive an internal inspection annually, or when the inspector deems necessary. The internal inspection frequency may be extended to triennially with prior approval from t... | Colorado | Colorado Revised Statutes, Title 9. Safety — Industrial and Commercial, Article 4. Buildings and Equipment, Boiler Inspection . | https://referencesource.org/boiler-inspection-requirements-by-state/colorado/ | [
"power_boiler_interval"
] | null | null |
Insurance company inspectors commissioned by the department (accepted in lieu of department inspector) | Boilers under federal control; portable boilers used in pumping, heating, steaming, and drilling in the open field; portable boilers for agricultural purposes; steam-heating boilers, hot-water heaters, and hot-water heating boilers in private homes or apartment houses of not more than five families; hot-water heaters a... | Department of Administrative Services, Bureau of Boilers, Office of the State Building Inspector, Division of Construction Services | connecticut | external biennially, with an internal at the discretion of the inspector | one annual internal and external inspection; one annual external inspection under operating conditions not more than six months after the internal and external inspection (power boilers with internal water treatment under qualified engineer: internal and external inspection every eighteen months, plus external inspecti... | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Public service companies as defined in Connecticut General Statutes (Section 16-1). OBJECTS SUBJECT TO RULES FOR FIELD INSPECTION Same as OBJECTS SUBJECT TO RULES FOR CONSTRUCTION AND STAMPING, plus water heaters in public buildings, regardless of size or BTU rating. INSPECTIONS REQUIRED Power boilers: One annual inter... | Connecticut | Connecticut General Statutes, Chapter 540, Sections 29-231 through 29-244 . | https://referencesource.org/boiler-inspection-requirements-by-state/connecticut/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"state"
] | null | null |
commissioned inspectors holding a National Board Inservice Inspector Commission (IS), commissioned insurance company inspectors, and National Board-369 accredited inspection agencies | null | The Delaware Department of Natural Resources and Environmental Control | delaware | biennial external inspections | annual internal and external inspections, with external inspections conducted under pressure within six months of internal inspections | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Governing body: The Delaware Department of Natural Resources and Environmental Control administers the Boiler Safety Program under Delaware Code, Title 7, Chapter 74B, Section 7401B. Authorized inspector types: Delaware accepts commissioned inspectors holding a National Board Inservice Inspector Commission (IS), commis... | Delaware | Delaware Code, Title 7, Chapter 74B, Section 7401B | https://referencesource.org/boiler-inspection-requirements-by-state/delaware/ | [
"accepted_inspectors",
"governing_body",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Power boilers, miniature boilers, and high-pressure, high-temperature water boilers: Annual internal inspection; Annual externa... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Governing body: The Delaware Department of Natural Resources and Environmental Con... |
Insurance companies required to do inservice inspections of all insured boilers in areas of public assembly; upon filing report of satisfactory inspection, boiler exempt from inspection by the Boiler Safety Program | Boilers and lined hot-water heaters under the control of the federal government; HLW hot-water supply boilers or lined storage water heaters directly fired with oil, gas, electricity, or solar energy not exceeding 400,000 BTU per hour, 210°F, 120 gallons | Bureau of Fire Prevention, Boiler Safety Section, Division of the State Fire Marshal | florida | certificate inspection biennially; internal inspection if the construction so permits | certificate inspection annually; external inspection while under pressure; internal inspection if the construction so permits | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Power boilers and high-temperature water boilers: Certificate inspection annually; External inspection while under pressure; Internal inspection if the construction so permits. Low-pressure steam or vapor heating boilers: Certificate inspection biennially; Internal inspection if the construction so permits. Hot-water h... | Florida | Florida Statutes, Title 33. Regulations of Trade, Commerce, Investments and Solicitations, Chapter 554. Boiler Safety , Sections 101.1 through 115.0. | https://referencesource.org/boiler-inspection-requirements-by-state/florida/ | [
"low_pressure_boiler_interval",
"power_boiler_interval"
] | null | null |
Insurance company inspectors commissioned by the department (accepted in lieu of department inspector); owner/user inspection organizations approved by the chief safety engineer | Boilers and pressure vessels under federal control; US DOT pressure vessels for transportation and storage of compressed or liquefied gases; unfired pressure vessels on vehicles under other state or federal agencies; air tanks on railroad rights-of-way; unfired pressure vessels not exceeding 5 cu ft/250 psig or 1-1/2 c... | Office of Insurance and Safety Fire Commissioner | georgia | certificate inspection biennially with an internal inspection quadrennially where construction permits | certificate inspection annually, internal inspection where construction permits, plus external inspection while under operating pressure | triennial certificate inspection (if subject to internal corrosion); all others at intervals set by the board with at least a quadrennial certificate inspection | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | King, Commissioner William "Butch" Lynch Jr., Chief Inspector Office of Insurance and Safety Fire Commissioner 2 Martin Luther King Jr. Drive West Tower, Suite 920 Atlanta , Georgia 30334 Telephone ­— 404.656.2064 Email — blynch@oci.ga.gov Firemarshal@oci.ga.gov Fax — 404.679.5818 EMPOWERMENT Dire... | Georgia | Official Code of Georgia Annotated, Title 25. Labor, Chapter 15 Article 2. Regulations of Boilers and Pressure Vessel Safety Act , Chapter 120-3-26. Georgia Boiler and Pressure Vessel Rules. | https://referencesource.org/boiler-inspection-requirements-by-state/georgia/ | [
"governing_body",
"state",
"statute_citation"
] | null | null |
Insurance companies required to inspect all insured objects; inspection reports submitted within thirty days | Boilers and pressure vessels under federal inspection and control; unfired pressure vessels meeting US DOT requirements for transporting liquids or gases under pressure; containers for storage of liquefied compressed flammable gases under other agencies; unfired pressure vessels with nominal water-containing capacity o... | Hawaii Department of Labor and Industrial Relations, Division of Occupational Safety and Health, Boiler and Elevator Inspection Branch | hawaii | biennial external inspection and/or an internal inspection where construction permits (large steam heating boilers require annual internal inspection, and external inspection at approximately six-months after each internal) | annual internal or permit inspection; external inspection at approximately six-months after each internal (biennial internal inspections permitted for power boilers with continuous internal water treatment under qualified supervision upon approval of the director) | biennial external inspection and/or internal inspection where construction permits | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Hawaii Revised Statutes, Chapter 397 Boiler and Elevator Safety Law . Hawaii Administrative Rules: Part 10, Boilers and Pressure Vessels. RULES FOR CONSTRUCTION AND STAMPING Construction: | Hawaii | Hawaii Revised Statutes, Chapter 397 Boiler and Elevator Safety Law . Hawaii Administrative Rules: Part 10, Boilers and Pressure Vessels. | https://referencesource.org/boiler-inspection-requirements-by-state/hawaii/ | [
"state",
"statute_citation"
] | null | null |
Insurance company (contact insurance company for regular inspections) | null | Idaho Division of Occupational and Professional Licenses, Industrial Safety Section | idaho | null | null | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | The Idaho Legislature repealed the Boiler and Pressure Vessel Rules effective March 29, 2010. Contact your insurance company for regular inspections in order to maintain the safety of your workplace. | Idaho | null | https://referencesource.org/boiler-inspection-requirements-by-state/idaho/ | [
"state"
] | null | null |
division inspectors, commissioned insurance company inspectors, and commissioned owner inspectors | null | The Illinois Office of the State Fire Marshal | illinois | biennial inspections | annual internal and external inspections while not under pressure, plus an annual external inspection while under pressure | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Governing body: The Illinois Office of the State Fire Marshal oversees boiler safety through its Division of Boiler and Pressure Vessel Safety under Illinois Compiled Statutes, Chapter 430, Subchapter 75, Boiler and Pressure Vessel Safety Act. Authorized inspector types: Illinois accepts division inspectors, commission... | Illinois | Illinois Compiled Statutes, Chapter 430, Subchapter 75, Boiler and Pressure Vessel Safety Act | https://referencesource.org/boiler-inspection-requirements-by-state/illinois/ | [
"accepted_inspectors",
"governing_body",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Illinois Compiled Statutes, Health and Safety, Chapter 430. Public Safety, Subchapter 75. Boiler and Pressure Vessel Safety Act... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Governing body: The Illinois Office of the State Fire Marshal oversees boiler safe... |
State-employed inspectors conduct all first inspections. For ongoing inspections, commissioned insurance inspectors when vessels are insured and commissioned owner inspection agency inspectors | null | Department of Homeland Security's Division of Fire and Building Safety | indiana | biennial certificate inspections conducted externally and internally, where construction permits | annual internal and external certificate inspections, plus an annual external inspection while under pressure if possible | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | The Department of Homeland Security’s Division of Fire and Building Safety oversees boiler inspections under Indiana Administrative Code, Title 680. Authorized inspector types: State-employed inspectors conduct all first inspections. For ongoing inspections, Indiana requires commissioned insurance inspectors when... | Indiana | Indiana Administrative Code, Title 680 | https://referencesource.org/boiler-inspection-requirements-by-state/indiana/ | [
"accepted_inspectors",
"governing_body",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "One annual internal and external certificate inspection; One annual external inspection while under pressure, if possible. With... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "The Department of Homeland Security’s Division of Fire and Building Safety o... |
Inspections made by inspectors employed by insurance companies and commissioned by the division are accepted in lieu of inspections made by a state inspector. | Section 89.4 identifies the objects that are exempted from section 89.3. | Department of Inspections, Appeals, & Licensing, Boilers & Pressure Vessel Inspection Bureau | iowa | null | null | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | INSPECTIONS REQUIRED <http://www.legis.iowa.gov/docs/ico/chapter/89.pdf> Iowa Code Chapter 89 Section 89.3 identifies the different equipment types, inspection type(s), and the inspection schedule(s) to be performed. Section 89.4 identifies the objects that are exempted from section 89.3. INSURANCE INSPECTION REQUIREME... | Iowa | Iowa Code Chapter 89; Iowa Administrative Code Chapters 481-390 through 481-395 | https://referencesource.org/boiler-inspection-requirements-by-state/iowa/ | [
"exemptions",
"state"
] | null | null |
Inspections made by inspectors employed by insurance companies and certified by the chief inspector are accepted in lieu of inspections made by a state inspector. | Boilers and pressure vessels under the control of the US government. Fire engine boilers brought into the state for temporary use in times of emergency. Boilers and pressure vessels located on producing oil and gas leases or storage areas outside the limits of any municipality, used solely for oil and gas production pu... | Office of the State Fire Marshal | kansas | Steam heating boilers: Annual certificate inspection; A triennial internal inspection where construction permits. Hot-water supply boilers: a triennial external certificate inspection (under 400,000 BTU per hour). Low-pressure hot-water supply boilers with heat input over 400,000 BTU: an annual external certificate ins... | Annual certificate inspection (internal inspection); Annual external inspection while under pressure, if possible, at approximately a six-month interval from the certificate inspection. | One-time inspection of new installations and the replacement of vessels 15 cubic feet and over constructed and installed after January 1, 1999. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | STATE DEPARTMENT Robert Stimson, Acting Chief Boiler Inspector Office of the State Fire Marshal 800 S.W. Jackson St., Suite 104 Topeka , Kansas 66612 Telephone — 785.296.3401 Email — boiler.inspection@ks.gov rob.stimson@ks.gov Fax — 785.296.0151 EMPOWERMENT Legislative committees empowered to make, al... | Kansas | Kansas Statutes Annotated, Chapter 44. Labor and Industries, Kansas Boiler Safety Act, K.S.A 44-913 et. seq. | https://referencesource.org/boiler-inspection-requirements-by-state/kansas/ | [
"governing_body",
"state",
"statute_citation"
] | null | null |
Department inspectors conduct all new installation inspections. For ongoing inspections, commissioned insurance company inspectors | null | Department of Housing, Buildings and Construction, Division of Plumbing | kentucky | biennial internal and external inspections, where construction permits, with a two-month grace period allowed | annual internal and external inspections while not under pressure, plus annual external inspections while under pressure if possible | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Governing body: The Department of Housing, Buildings and Construction oversees boiler inspections through its Division of Plumbing under Kentucky Revised Statutes, Title XIX, Chapter 236.00, Sections .005 through .990. Authorized inspector types: Department inspectors conduct all new installation inspections. For ongoi... | Kentucky | Kentucky Revised Statutes, Title XIX, Chapter 236.00, Sections .005 through .990 | https://referencesource.org/boiler-inspection-requirements-by-state/kentucky/ | [
"accepted_inspectors",
"governing_body",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "exemptions",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Kentucky Revised Statutes , Chapter 234. Pressure vessels used for transportation of compressed gases constructed and operated in compliance ... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Governing body: The Department of Housing, Buildings and Construction oversees boi... |
Inspections made by inspectors employed by insurance companies and commissioned by the department are accepted in lieu of inspections made by deputy boiler inspectors. | Boilers under federal control. Boilers on steam fire engines brought into the state for temporary use in times of emergency. Portable boilers used for agricultural purposes only. Boilers built for a pressure of 15 psig or less, for noncommercial use. All potable water boilers and hot-water heaters, except the provision... | Louisiana State Fire Marshal Office, Mechanical Safety Section | louisiana | A certificate inspection will be conducted biennially: Steam or vapor boilers: An external inspection and internal inspection biennially where construction permits; Hot-water heating and hot-water supply boilers: An external certificate inspection biennially, and – where construction permits — an internal inspection ev... | An annual external certificate inspection followed by an internal certificate inspection approximately six months after each external inspection. The interval between internal inspections may be extended for a period not to exceed 24 months on a stationary boiler provided certain conditions are met. Internal inspection... | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Louisiana Revised Statutes, Title 23, Chapter 5, Part III, Regulations Affecting Boilers . | Louisiana | Louisiana Revised Statutes, Title 23, Chapter 5, Part III, Regulations Affecting Boilers | https://referencesource.org/boiler-inspection-requirements-by-state/louisiana/ | [
"state",
"statute_citation"
] | null | null |
Inspections made by inspectors employed by insurance companies and licensed by the Boiler and Pressure Vessel Safety Program are accepted in lieu of inspections made by a department inspector. | Boilers and pressure vessels under federal control. Boilers and pressure vessels used for agricultural purposes only. Boilers used solely for propelling motor road vehicles. Boilers of steam fire engines brought into the state for temporary use in times of emergency to check conflagrations. Low pressure steam heating b... | Boiler and Pressure Vessel Safety Program, Office of Professional and Occupational Regulation | maine | Low pressure steam heating boilers located in schoolhouses: one annual certificate inspection, which shall be an internal inspection every third year, with an external or internal inspection at the discretion of the inspector on the two intervening years. Low pressure hot-water supply boilers located in schoolhouses: o... | One annual internal certificate inspection; One annual external inspection, in operation, approximately six months from the certificate inspection. | Initial inspection shall be an external safety inspection; Renewal certificate inspections are completed once every 3 years and it shall be an internal where construction permits. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | High-pressure boilers: One annual internal certificate inspection; One annual external inspection, in operation, approximately six months from the certificate inspection. Miniature boilers: One annual certificate inspection; One biennial internal inspection. Cast-iron boilers: one annual certificate inspection while un... | Maine | Maine Revised Statutes, Title 32. Professions and Occupations, Chapter 131. Boilers and Pressure Vessels, Sections 15101 through 15121. | https://referencesource.org/boiler-inspection-requirements-by-state/maine/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval"
] | null | null |
commissioned special inspectors from insurance companies. The Commissioner may also commission qualified owner company inspectors upon request | null | Department of Labor, Licensing and Regulation's Safety Inspections Unit | maryland | biennial certificate inspections | annual internal inspections, where construction permits and annual external inspections performed while under pressure | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Annotated Code of Maryland, Public Safety Article, Title 12, Subtitle 9. Authorized inspector types: Maryland accepts commissioned special inspectors from insurance companies. The Commissioner may also commission qualified owner company inspectors upon request. Inspection frequency: High-pressure boilers require annual... | Maryland | Annotated Code of Maryland, Public Safety Article, Title 12, Subtitle 9 | https://referencesource.org/boiler-inspection-requirements-by-state/maryland/ | [
"accepted_inspectors",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Power boilers and high-pressure, high-temperature boilers: Annual internal inspection when construction permits; otherwise, as ... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Annotated Code of Maryland, Public Safety Article, Title 12, Subtitle 9. Authorize... |
Inspections, except first inspections, made by inspectors employed by Authorized Inspection Agencies and commissioned by the department are accepted in lieu of inspections made by a department inspector. | All boilers, refrigeration and air conditioning systems, except when under the jurisdiction of the federal government. Heating boilers having less than 4 square feet grate surface; having a steam capacity less than 104 pounds per hour; used as a hot-water heating boiler with an output capacity less than 200,000 BTU per... | Department of Fire Services, Chief of Engineering Inspections | massachusetts | Hot-water heating and hot-water supply boilers: One inspection annually; One internal inspection every three years where construction permits. | One annual internal inspection; One annual external inspection with boiler in service at approximately a six-month interval from the internal inspection. | Air tanks: one internal inspection every two years. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | The General Laws of Massachusetts, Part I. Administration of the Government, Title 20. Public Safety and Good Order, Chapter 146. Inspection of Boilers, Air Tanks, etc. RULES FOR CONSTRUCTION AND STAMPING Construction: | Massachusetts | The General Laws of Massachusetts, Part I. Administration of the Government, Title 20. Public Safety and Good Order, Chapter 146. Inspection of Boilers, Air Tanks, etc. | https://referencesource.org/boiler-inspection-requirements-by-state/massachusetts/ | [
"state",
"statute_citation"
] | null | null |
Department inspectors conduct all new and secondhand boiler inspections. For ongoing inspections, licensed inspectors from insurance companies | null | Department of Licensing and Regulatory Affairs' Boiler Division | michigan | biennial certificate inspections, with a two-month grace period allowed | annual certificate inspections and annual external inspections while under pressure within six months of the internal inspection | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Boiler Division oversees inspections under Michigan Compiled Laws, Skilled Trades Act of 2016, Sections 339.5901 through 339.5947. Authorized inspector types: Department inspectors conduct all new and secondhand boiler inspections. For ongoing inspections, Michigan accepts licensed inspectors from insurance companies. ... | Michigan | Michigan Compiled Laws, Skilled Trades Act of 2016, Sections 339.5901 through 339.5947 | https://referencesource.org/boiler-inspection-requirements-by-state/michigan/ | [
"accepted_inspectors",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "exemptions",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Michigan Compiled Laws, Skilled Trades Act of 2016, Sections 339.5901 through 339.5947 RULES FOR CONSTRUCTION AND STAMPING Construction:",
... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Boiler Division oversees inspections under Michigan Compiled Laws, Skilled Trades ... |
Inspections made by inspectors employed by insurance companies and holding a valid Certificate of Competency issued by the department are accepted in lieu of inspections made by a department inspector. | Boilers and pressure vessels under federal control. Boilers and pressure vessels in buildings occupied solely for residential purposes with accommodations for not more than five families. Railroad locomotives. Air tanks installed on the right-of-way of railroads. Unfired pressure vessels having an internal or external ... | Minnesota Department of Labor and Industry, Construction Codes and Licensing Division, Boiler Division | minnesota | Boilers and steam generators: one annual inspection. | Boilers and steam generators: one annual inspection. | Unfired pressure vessels: biennial inspection. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Boilers and steam generators: one annual inspection. Unfired pressure vessels: biennial inspection. Stationary show boilers used for display and demonstration: Biennial inspection. Note: Refer to last two paragraphs under Insurance Inspection Requirements. INSURANCE INSPECTION REQUIREMENTS Inspections made by inspector... | Minnesota | Minnesota Statutes – 2023, Chapters 326B.93 to 326B.998, Boilers. Minnesota Rules – Chapter 5225. | https://referencesource.org/boiler-inspection-requirements-by-state/minnesota/ | [
"accepted_inspectors",
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval",
"state"
] | null | null |
Inspections made by insurance company inspectors commissioned by the board are accepted in lieu of inspections made by a department inspector. | Boilers and pressure vessels located on US government property and/or under federal government control. Pressure vessels used for transportation and storage of compressed gases when constructed in compliance with specifications of the US Department of Transportation. Air tanks located on vehicles operating under the ru... | Mississippi State Department of Health, Boiler and Pressure Vessel Safety Branch | mississippi | Heating boilers shall receive a certificate inspection biennially. | Power boilers and high-pressure, high-temperature water boilers shall receive a certificate inspection annually (or as the board may require) and shall receive an annual external inspection while under pressure, if possible. | Pressure vessels subject to internal corrosion shall receive a certificate inspection biennially. Pressure vessels not subject to internal corrosion shall receive a certificate inspection at intervals set by the board. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Pressure vessels covered under the Liquefied Compressed Gas Equipment Inspection Law of Mississippi (Sections 75-57-1 through 75-57-63), Mississippi Code of 1972 . Air-receiving tanks and attached tanks used in connection with automobile filling stations that do not exceed 15 cubic feet in volume and 250 psig pressure ... | Mississippi | Mississippi Code, Title 45. Public Safety and Good Order, Chapter 23. Boiler and Pressure Vessel Safety. | https://referencesource.org/boiler-inspection-requirements-by-state/mississippi/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval",
"state"
] | null | null |
Inspectors employed by insurance companies and approved owner/user inspection agencies are accepted in lieu of inspections made by the department. | Water heaters, pool heaters, and hot-water supply boilers in which none of the following limitations is exceeded: A heat input of 200,000 BTU per hour; A water temperature of 210°F; A nominal water-containing capacity of 120 gallons. Hot-water storage tanks less than or equal to 120 gallons. Pressure vessels that have ... | Division of Fire Safety, Boiler and Pressure Vessel Safety Unit | missouri | Low-pressure boilers and pressure vessels: A biennial certificate inspection: Steam or vapor boilers shall have an external inspection and an internal inspection biennially where construction permits; Hot-water heating and hot-water supply boilers shall have an external inspection biennially and where construction perm... | An annual certificate inspection which shall be an internal inspection where construction permits; An annual external inspection while under normal operating conditions. | Pressure vessels shall have an external inspection biennially. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Power boilers; high-pressure, high-temperature water boilers; waste heat boilers; and unfired steam boilers and thermal fluid heaters: An annual certificate inspection which shall be an internal inspection where construction permits; An annual external inspection while under normal operating conditions. Low-pressure bo... | Missouri | Missouri Revised Statutes, Chapter 650. Department of Public Safety, Boiler and Pressure Vessel Act, Sections 200 through 290. Rules of Department of Public Safety, Division 40, Chapter 2, Boiler and Pressure Vessel Safety Rules. | https://referencesource.org/boiler-inspection-requirements-by-state/missouri/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval"
] | null | null |
Inspections made by inspectors employed by insurance companies may be accepted in lieu of inspections made by bureau inspectors as equivalent to those of the state inspectors. Each such special inspector shall hold a certificate as boiler inspector issued by the National Board of Boiler and Pressure Vessel Inspectors. | Boilers under federal control. Steam-heating boilers operated at not over 15 psig in private residences or apartments of six or fewer families. Hot-water heating or supply boilers operated at not over 50 psig and temperatures not over 250°F when in private residences, or apartments of six or fewer families. | Department of Labor and Industry, Building Codes Bureau, Boiler, Elevator, Weights and Measures | montana | All automatically fired boilers rated with an input of less than 400,000 BTU per hour: biennial inspection. | Steam heating and power boilers: annual internal inspection. All manually-fired boilers and all boilers and banks of boilers rated with a total input of 400,000 BTU per hour or greater: annual inspection. | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | All manually-fired boilers and all boilers and banks of boilers rated with a total input of 400,000 BTU per hour or greater: annual inspection. All automatically fired boilers rated with an input of less than 400,000 BTU per hour: biennial inspection. Steam heating and power boilers: annual internal inspection. This in... | Montana | Montana Code 2001, Title 50. Health and Safety, Chapter 60. Building Construction Standards and Chapter 74. Boiler and Steam Engines. | https://referencesource.org/boiler-inspection-requirements-by-state/montana/ | [
"low_pressure_boiler_interval",
"power_boiler_interval"
] | null | null |
Inspections made by Special Inspectors employed by National Board Accredited Authorized Inspection Agencies are accepted in lieu of inspections made by an agency inspector. | Boilers under federal jurisdiction and control. Boilers of railway locomotives subject to federal inspection. Boilers operated and regularly inspected by railway companies operating in interstate commerce. Boilers used exclusively for agricultural purposes. Steam-heating boilers in single family residences and apartmen... | Nebraska State Fire Marshal Agency, Boiler Inspection Division | nebraska | Steam or vapor boilers shall receive an external inspection annually to renew the certificate and an internal inspection biennially where construction permits. Pool heaters, spa heaters, hot water heating boilers and hot water supply boilers shall receive an external inspection annually to renew the certificate, and, w... | Power boilers and high-pressure, high-temperature water boilers shall receive an internal inspection annually where construction permits and an external inspection while in operation, if possible; otherwise, it shall be as complete an inspection as possible. All jurisdictional boilers shall receive an annual external c... | Pressure vessels subject to internal corrosion shall be inspected internally and externally biennially. Pressure vessels not subject to corrosion shall receive an external inspection biennially. Pressure vessels not subject to internal corrosion shall be inspected internally, where construction permits, quinquennially ... | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Nebraska Administrative Code and the National Board Inspection Code , or API-510, as applicable. INSURANCE INSPECTION REQUIREMENTS Inspections made by Special Inspectors employed by National Board Accredited Authorized Inspection Agencies are accepted in lieu of inspections made by an agency inspector. | Nebraska | Nebraska Revised Statutes, Boiler Inspection Act. Title 81, Sections 81-5,165 to 81-5,189. Nebraska Administrative Code, Title 229. Chapters 1 through 28. | https://referencesource.org/boiler-inspection-requirements-by-state/nebraska/ | [
"accepted_inspectors",
"state"
] | null | null |
An inspection made by a special inspector (employed by an inspection entity), holding a Certificate of Competency received from the division, is accepted in lieu of an inspection made by a Jurisdictional inspector. | Objects meeting exemption rules per NAC 455C.114 | Department of Business & Industry, Division of Industrial Relations, Mechanical Compliance Section | nevada | Low-pressure steam heating boilers: one annual external inspection. Where design and construction permit, an internal inspection shall be conducted biennially. Hot-water heating boilers and hot-water supply boilers: one internal inspection biennially if design and construction permit and inspector/special inspector req... | One annual internal inspection; One annual external inspection at approximately a six-month interval from the internal inspection. | Mechanical Compliance Section jurisdiction: One external inspection quadrennially; internal if design and construction permit. Mine Section jurisdiction: One external inspection triennially; internal if design and construction permit. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Nevada Administrative Code, Title 455C. Boilers, Elevators, and Pressure Vessels Mine Section: | Nevada | Nevada Administrative Code, Title 455C. Boilers, Elevators, and Pressure Vessels | https://referencesource.org/boiler-inspection-requirements-by-state/nevada/ | [
"state",
"statute_citation"
] | null | null |
Inspectors employed by insurance companies and commissioned by the department are accepted in lieu of inspections made by a department inspector. | Properties used exclusively as private residences or apartment houses of fewer than three family units. Properties used exclusively as private residences or apartment houses with three or more family units with an output of less than 200,000 BTU per hour. | New Hampshire Department of Labor | new-hampshire | one biennial certificate inspection, with an internal inspection at least once quadrennially where construction permits | One annual certificate inspection; One annual external inspection while under pressure, if possible. | one biennial certificate inspection | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Power boilers and high-pressure, high-temperature water boilers: One annual certificate inspection; One annual external inspection while under pressure, if possible. Low-pressure steam or vapor heating boilers, hot-water heating and hot-water supply boilers: one biennial certificate inspection, with an internal inspect... | New Hampshire | New Hampshire Revised Statutes, Annotated and Administrative Rules, New Hampshire Department of Labor, Title 12. Public Safety and Welfare, Chapter 157-A. Boilers and Pressure Vessels, Sections A1 through A14. | https://referencesource.org/boiler-inspection-requirements-by-state/new-hampshire/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval"
] | null | null |
commissioned inspectors from authorized agencies who hold a Certificate of Competency. The state also recognizes API and National Board owner-user inspection programs | null | Department of Labor and Workforce Development's Mechanical Inspection Bureau | new-jersey | annual external inspections and biennial internal inspections | annual internal and external inspections | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | New Jersey State Statutes, Title 34, and Administrative Code 12:90. Authorized inspector types: New Jersey accepts commissioned inspectors from authorized agencies who hold a Certificate of Competency. The state also recognizes API and National Board owner-user inspection programs. Inspection frequency: High-pressure b... | New Jersey | New Jersey State Statutes, Title 34, and Administrative Code 12:90 | https://referencesource.org/boiler-inspection-requirements-by-state/new-jersey/ | [
"accepted_inspectors",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Boilers: An annual internal and external inspection for steam boilers; An annual external inspection and biennial internal insp... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "New Jersey State Statutes, Title 34, and Administrative Code 12:90. Authorized ins... |
Any inspection agency, authorized by the National Board, licensed to sell boiler or pressure vessel insurance in New Mexico, and insuring a boiler located in the state is required to inspect. Insurance company inspectors must hold a National Board Commission and be commissioned by the state. | Public utilities, rural electric cooperatives, mine processing, refinery processing, gas processing, and lumber industries (sawmill only). Listed and approved potable water heaters when heat input does not exceed 200,000 BTU per hour, water temperature does not exceed 250°F and 160 psi pressure, and nominal water-conta... | Regulation and Licensing Department, Construction Industries Division | new-mexico | A biennial external inspection; An internal inspection if need indicates. (Applies to low-pressure steam boilers and low-pressure, hot-water heating boilers, and hot-water supply boilers.) | An annual external inspection; An annual internal inspection, where construction permits. | null | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Any inspection agency, authorized by the National Board, licensed to sell boiler or pressure vessel insurance in New Mexico, and insuring a boiler located in the state is required to inspect. Insurance company inspectors must hold a National Board Commission and be commissioned by the state. CERTIFICATE OF INSPECTION A... | New Mexico | New Mexico Administrative Code, Title 14. Housing and Construction, Chapter 9. Mechanical Codes, Part 4. Boilers. | https://referencesource.org/boiler-inspection-requirements-by-state/new-mexico/ | [
"accepted_inspectors",
"state"
] | null | null |
commissioned insurance company inspectors and National Board-commissioned shop inspectors | null | New York Department of Labor's Boiler Safety Bureau | new-york | triennial internal inspections and biennial external inspections (steam); internal inspections every five years and biennial external inspections (hot-water) | annual internal and external inspections, with external inspections conducted approximately six months after internal inspections | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | The New York Department of Labor’s Boiler Safety Bureau administers inspections under New York State Laws, Labor, Chapter 31, Article 7, Section 204. Authorized inspector types: New York accepts commissioned insurance company inspectors and National Board-commissioned shop inspectors. Inspection frequency: High-p... | New York | New York State Laws, Labor, Chapter 31, Article 7, Section 204 | https://referencesource.org/boiler-inspection-requirements-by-state/new-york/ | [
"accepted_inspectors",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "exemptions",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "New York State Laws, Labor, Chapter 31. Article 7, Section 204. RULES FOR CONSTRUCTION AND STAMPING Construction:",
"value": "Boilers loc... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "The New York Department of Labor’s Boiler Safety Bureau administers inspecti... |
Department inspectors conduct all first inspections. For subsequent inspections, commissioned insurance inspectors. Local Law 62/91 also permits NYC-licensed master plumbers, oil burner installers, and high-pressure boiler operators to conduct annual low-pressure inspections | null | New York City Department of Buildings | new-york-city | annual external inspections and triennial internal inspections (steam); annual external inspections and internal inspections every five years (hot-water) | annual internal and external inspections (steam); annual external inspections and triennial internal inspections (hot-water) | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Governing body: The New York City Department of Buildings administers inspections under New York State Industrial Code Rules 4 and 14. Authorized inspector types: Department inspectors conduct all first inspections. For subsequent inspections, New York City accepts commissioned insurance inspectors. Local Law 62/91 als... | New York City | New York State Industrial Code Rules 4 and 14 | https://referencesource.org/boiler-inspection-requirements-by-state/new-york-city/ | [
"accepted_inspectors",
"governing_body",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "exemptions",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "High-pressure steam boilers: One annual external inspection; One annual internal inspection. High-pressure, high-temperature hot-water boiler... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Governing body: The New York City Department of Buildings administers inspections ... |
Inspections made by "Special" inspectors employed by insurance companies and commissioned by the Commissioner are accepted in lieu of inspections made by a State deputy inspector. | Boilers and pressure vessels owned and/or operated by the federal government. Boilers and pressure vessels which are located in private residences or in apartment houses of fewer than six families. Pressure vessels operating at a working pressure not exceeding 15 psig. | Department of Labor, Boiler Safety Bureau | north-carolina | Low-pressure boilers and pressure vessels: External 2 Years. | High-pressure boilers: Internal 1 Year, External 1 Year. | Low-pressure boilers and pressure vessels: External 2 Years. Hydropneumatic storage tanks: External 4 Years. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | North Carolina General Statutes, Chapter 95, Article 7A, and North Carolina Administrative Code, Title 13, Chapter 13. RULES FOR CODES AND STAMPING Codes: | North Carolina | North Carolina General Statutes, Chapter 95, Article 7A, and North Carolina Administrative Code, Title 13, Chapter 13. | https://referencesource.org/boiler-inspection-requirements-by-state/north-carolina/ | [
"state",
"statute_citation"
] | null | null |
Inspections made by inspectors employed by National Board approved Authorized Inspection Agencies and commissioned by the department are accepted. Inspections made by inspectors employed by owners/users and commissioned by the department are accepted. | Boilers and pressure vessels subject to federal inspection or under federal control. Boilers and pressure vessels located on farms and used solely for agricultural purposes. Heating boilers which are located in private residences or in apartment houses of fewer than six family units. Miniature hobby boilers not exceedi... | North Dakota Department of Environmental Quality, Boiler Inspection Program | north-dakota | Low-pressure steam boilers, steel: Internal 2 Years, External 2 Years. Low-pressure steam boilers, cast-iron: External 1 Year. Hot-water heating and hot-water supply boilers: External 3 Years (one annual external inspection for those located in hospitals, nursing homes, schools, nursery schools, and kindergartens). | High-pressure boilers: Internal 1 Year, External 1 Year (while under pressure). | Field inspection of pressure vessels (other than anhydrous ammonia pressure vessels) is not required. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Item | Internal | External | High-pressure boilers | 1 Year | 1 Year* | Low-pressure steam boilers, steel | 2 Years | 2 Years | Low-pressure steam boilers, cast-iron | — | 1 Year | Hot-water heating and hot-water supply boilers | — | 3 Years** | *External inspection while under pressure. **One annual extern... | North Dakota | North Dakota Statutes, Title 23.1. Environmental Quality, Chapter 23.1-16. Boiler Inspection, Sections 1 through 14. | https://referencesource.org/boiler-inspection-requirements-by-state/north-dakota/ | [
"low_pressure_boiler_interval",
"power_boiler_interval"
] | null | null |
commissioned inspectors from authorized insurance companies | null | Ohio Department of Commerce's Division of Industrial Compliance | ohio | triennial internal inspections and annual external inspections under operating conditions | annual internal and external inspections while operating | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | Ohio Ohio’s inspection framework: Governing body: The Ohio Department of Commerce’s Division of Industrial Compliance oversees boiler inspections under Ohio Revised Code, Title 41, Chapter 4104. Authorized inspector types: Ohio accepts commissioned inspectors from authorized insurance companies. Inspection ... | Ohio | Ohio Revised Code, Title 41, Chapter 4104 | https://referencesource.org/boiler-inspection-requirements-by-state/ohio/ | [
"accepted_inspectors",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "Ohio Revised Code, Title 41. Labor and Industry, Chapter 4104. Division of Boiler Inspection, Chapter 4104. Boilers. RULES FOR ... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "Ohio Ohio’s inspection framework: Governing body: The Ohio Department of Com... |
Inspections made by insurance company inspectors may be accepted in lieu of inspections made by a department inspector, provided a photostatic copy of the inspector's National Board Certificate is furnished to the department and the inspector is authorized by the commissioner of labor. | Pressure vessels not exceeding 15 cubic feet in volume and 250 psig. Low-pressure steam boilers, hot-water heating boilers, hot-water supply boilers, hot-water supply heaters, or pressure vessels located in private residences or in apartment houses of fewer than six family units. Pressure vessels on remote sites limite... | Department of Labor, Safety Standards Division | oklahoma | Low-pressure steam and vapor heating boilers: Internal 2 Years, External 1 Year. Hot-water heating and hot-water supply boilers: Internal at the discretion of the inspector, External 1 Year. | Power boilers and high-temperature, high-pressure boilers: Internal 1 Year, External 1 Year (under pressure). | Pressure vessels subject to internal corrosion: Internal 3 Years, External 3 Years. Pressure vessels not subject to internal corrosion: Internal 10 Years, External 3 Years. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Item | Internal | External | Power boilers and high-temperature, high-pressure boilers | 1 Year | 1 Year* | Low-pressure steam and vapor heating boilers | 2 Years | 1 Year | Hot-water heating and hot-water supply boilers | ** | 1 Year | Hot-water supply heaters | *** | 2 Years | Pressure vessels, excluding those within... | Oklahoma | Oklahoma State Statutes, Title 40. Labor, Oklahoma Boiler and Pressure Vessel Law, Sections 141.0 through 141.20 and Administrative Rules 380:25. | https://referencesource.org/boiler-inspection-requirements-by-state/oklahoma/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval"
] | null | null |
Inspections made by special boiler inspectors holding a valid Oregon Certificate of Competency from the Building Codes Division and continuously employed by insurance companies authorized to write boiler and machinery insurance in the state are accepted in lieu of inspections made by a deputy boiler inspector. | Boilers and pressure vessels under federal control. Domestic water heaters not exceeding 120 gallons, 210°F, 150 psig, and 200,000 BTU per hour. Boilers operated at less than 15 psig located on farms and used solely for agricultural purposes. Boilers or pressure vessels used in a single private residence (exempt from s... | Department of Consumer and Business Services, Building Codes Division, Boiler and Pressure Vessel Group | oregon | Low-pressure steam and vapor-heating boilers: Internal 2 Years, External 2 Years. Cast-iron boilers: External 2 Years. Low-pressure hot-water heating and hot-water supply boilers: Internal 6 Years, External 2 Years. | Power Boilers: Internal 1 Year, External 1 Year. | Pressure vessels subject to internal corrosion: Internal 2 Years, External 2 Years. Pressure vessels not subject to internal corrosion: External 2 Years. Pressure vessels containing anhydrous ammonia intended for use as a fertilizer: External 3 Years. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | INSURANCE INSPECTION REQUIREMENTS Inspections made by special boiler inspectors holding a valid Oregon Certificate of Competency from the Building Codes Division and continuously employed by insurance companies authorized to write boiler and machinery insurance in the state are accepted in lieu of inspections made by a... | Oregon | Oregon Revised Statutes, Volume 11, Title 38. Protection from Fire, Chapter 480. Explosives, Flammable Materials, Pressure Vessels, Sections 510 through 990. | https://referencesource.org/boiler-inspection-requirements-by-state/oregon/ | [
"accepted_inspectors",
"state"
] | null | null |
commissioned inspectors from authorized insurance companies and registered owner inspection agencies | null | Department of Labor and Industry's Boiler Division | pennsylvania | biennial internal or external inspections | annual internal and external inspections, though internal inspections may be extended to 24 months if specific criteria are met | null | https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/ | The Department of Labor and Industry’s Boiler Division administers inspections under Pennsylvania Code No. 104, Boiler and Unfired Pressure Vessel Law, Sections 1 through 17. Authorized inspector types: Pennsylvania accepts commissioned inspectors from authorized insurance companies and registered owner inspectio... | Pennsylvania | Pennsylvania Code No. 104, Boiler and Unfired Pressure Vessel Law, Sections 1 through 17 | https://referencesource.org/boiler-inspection-requirements-by-state/pennsylvania/ | [
"accepted_inspectors",
"low_pressure_boiler_interval",
"power_boiler_interval",
"state",
"statute_citation"
] | [
{
"as_of": "2026-08-05T00:00:00",
"field": "pressure_vessel_interval",
"source": "https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select",
"source_quote": "INSURANCE INSPECTION REQUIREMENTS Inspections made by inspectors of authorized insurance companies and companies operating vess... | [
{
"field": "governing_body",
"versions": [
{
"as_of": "2026-08-05T00:00:00",
"source": "https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/",
"source_quote": "The Department of Labor and Industry’s Boiler Division administers inspectio... |
Inspections are made by private inspectors and inspectors employed by insurance companies authorized by the Secretary of Labor and Human Resources. (Department of Labor and Human Resources does not make inspections). | All boilers and pressure vessels, except definitions and exemptions as established by ASME Code. | Commonwealth of Puerto Rico, Department of Labor and Human Resources, P.R. Occupational Safety and Health Administration (PR OSHA), Boiler and Elevator Division | puerto-rico | One annual internal; One annual external and operational. | One annual internal; One annual external and operational. | One annual internal; One annual external and operational. | https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select | Boilers and Pressure Vessels: One annual internal; One annual external and operational. | Puerto Rico | Regulation Number 17 of the Office of the Assistant Secretary for Occupational Safety & Health, Regulation of Boilers and Pressure Vessels | https://referencesource.org/boiler-inspection-requirements-by-state/puerto-rico/ | [
"low_pressure_boiler_interval",
"power_boiler_interval",
"pressure_vessel_interval"
] | null | null |
US boiler and pressure vessel inspection requirements by state
Canonical, always-current version: https://referencesource.org/boiler-inspection-requirements-by-state/ Machine-readable: https://referencesource.org/boiler-inspection-requirements-by-state/data.json — this mirror is a point-in-time copy.
- Last verified: 2026-08-05
- Stale after: 2027-08-05 (past this date, prefer the canonical copy — it re-verifies on a cadence this snapshot does not)
- Records: 55
State-by-state comparison of boiler and pressure vessel inspection requirements across all US states. Each record is one state with its inspection intervals by boiler type (power, low-pressure steam, hot water, unfired pressure vessel), accepted inspector qualifications (state, insurance, owner-user), residential and size/pressure exemptions, governing statute citation, and administering agency. Answers 'how often does Ohio require boiler inspections', 'which states accept insurance company inspections in lieu of state inspections', and 'are residential boilers exempt in my state'.
Provenance — what every record carries
Every record carries source (the URL the value was read from) and
source_quote (a verbatim quote from that page stating it). A value you
cannot check against its page is indistinguishable from an invented one;
these can all be checked. Each record is also individually addressable on
the canonical site at its url.
Licence position
Facts extracted from state statutes (government works) and industry reference (National Board Synopsis, freely published). Inspection intervals and exemptions are regulatory facts, not copyrightable.
Facts are not copyrightable; what this dataset takes from each source is a fact plus a short attributed quote linking back to the page that states it.
Sources
- https://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select
- https://www.chardonlabs.com/resources/commercial-boiler-inspection-regulations-by-state/
Fields
See any record in data/records.jsonl — field names are self-describing,
and the canonical page for each record renders them with labels:
https://referencesource.org/boiler-inspection-requirements-by-state/