Dataset Viewer
Auto-converted to Parquet Duplicate
part_a
stringclasses
7 values
part_b
stringclasses
10 values
question
stringclasses
10 values
short_answer
stringclasses
10 values
reference_page
stringclasses
10 values
00-419670-00001
00-414146-00002
Can I use the LCH hi-limit (00-414146-00002) instead of the LC117 (00-419670-00001)?
No. They are both 450F-class fryer hi-limits, but one is auto-reset and the other is manual-reset, and the set points differ (450 F vs 435 F). Substituting one for the other changes the safety behaviour of the fryer.
https://magenta-puffpuff-d66f59.netlify.app/compare/lc117-vs-lch-hi-limit/
00-348358-00001
00-410839-00004
Can I use the two-lead thermopile (00-410839-00004) instead of the coaxial one (00-348358-00001)?
No. Both are 36 in, 250-750 mV thermopiles, and that is exactly why they get confused. The 00-348358-00001 is the coaxial type with a 3/8-32 thread; 00-410839-00004 is the two-lead type with a different terminal arrangement. Same length and same output voltage do not make them interchangeable.
https://magenta-puffpuff-d66f59.netlify.app/compare/coaxial-vs-two-lead-thermopile/
00-419670-00001
00-410840-00002
Can I replace 00-419670-00001 with 00-410840-00002?
Usually yes, but check the sensing bulb first. The successor 00-410840-00002 uses a 1/4 in x 4-1/2 in bulb, while the original LC117 uses a 1/4 in x 4-7/8 in bulb - about 3/8 in shorter. Both are 450 F auto-reset hi-limits with a 30 in capillary and a 3/8 in MPT stuffing box.
https://magenta-puffpuff-d66f59.netlify.app/compare/00-419670-00001-vs-00-410840-00002/
00-411506-00013
00-913153
Is 00-913153 the same part as 00-411506-00013?
Distributor interchange tables treat 00-913153 as the current number for the same RX thermostat kit. This is a distributor-level cross-reference, not a statement published by the manufacturer, so verify against your own parts manual before ordering.
https://magenta-puffpuff-d66f59.netlify.app/compare/rx-kit-vs-913153/
00-348361-00001
00-348361-00001
Is the non-OEM version of 00-348361-00001 the same as the Hobart-branded one?
Possibly - and that is the point. Fenwal builds this thermostat; Hobart resells it under its own number. On this part, OEM and non-OEM listings often describe the same device sold through different channels. The price gap can be several times, so ask the seller whether the body carries the Fenwal name and a UL file num...
https://magenta-puffpuff-d66f59.netlify.app/compare/fenwal-oem-vs-aftermarket/
RTCU700609
RTBF800164
Are RTCU700609 and RTBF800164 the same thermostat?
No. RTCU700609 is the electronic regulating thermostat (105-185 C) for Hobart HEF-series fryers. RTBF800164 is the separate high-limit thermostat. They do different jobs and are not substitutes for each other.
https://magenta-puffpuff-d66f59.netlify.app/compare/rtcu700609-vs-rtbf800164/
00-410841-00001
00-410841-00028
Can I use the 24 V electronic-ignition gas valve (00-410841-00028) in place of a millivolt valve (00-410841-00001)?
No. A millivolt valve is operated by a thermopile (750 mV open circuit, about 500 mV under load) through a bleed-gas safety valve. The 24 V electronic-ignition valve has a different operator and is wired to an ignition module. They are not interchangeable, and the ignition module and valve are a matched pair.
https://magenta-puffpuff-d66f59.netlify.app/compare/millivolt-vs-24v-gas-valve/
00-340307-00003
00-416741-000G9
Can I use an 8500 W element in place of a 5500 W element?
No. Element wattage, voltage and physical length must all match the original. Fitting a higher-wattage element increases current draw beyond the contactor and wiring rating; fitting the wrong voltage delivers the wrong wattage even at the same nominal size.
https://magenta-puffpuff-d66f59.netlify.app/compare/5500w-vs-8500w-element/
00-410841-00001
00-410841-00002
Can I use the natural-gas valve (00-410841-00001) on LP?
No, not without the LP conversion kit. The LP version (00-410841-00002) uses the same body with LP conversion kit 51-1470. A natural-gas valve running on LP will not regulate correctly and is a safety hazard.
https://magenta-puffpuff-d66f59.netlify.app/compare/ng-vs-lp-gas-valve/
00-411506-00013
00-410687-00001
What is the difference between the RX, KX and K fryer thermostats?
They are three different thermostat families with different bulb diameters, capillary lengths and temperature ranges. RX is the 24 in, 200-400 F regulating kit. KX uses a 1/4 in bulb with a 12-1/8 in capillary. K is a separate family again. The letter matters more than the shape.
https://magenta-puffpuff-d66f59.netlify.app/compare/rx-vs-kx-vs-k-thermostat/

Commercial Fryer Parts β€” Cross-Reference Dataset

A machine-readable cross-reference dataset for commercial deep-fryer components: thermostats, hi-limits, gas valves, ignition boards, thermopiles and heating elements used on Hobart, Vulcan, Wolf, Garland, Frymaster and Broaster equipment.

Assembled from publicly available OEM parts manuals, distributor catalogs and interchange tables. Provided as a reference for identification and research.

Coverage

System Families Distinct part numbers
Thermostats / hi-limits 7 80
Gas valves / ignition / thermopiles 6 52
Heating elements 3 β€”

Brands: Hobart, Vulcan, Wolf, Garland, Frymaster, Broaster, Welbilt, plus Robertshaw and Fenwal component-level equivalents.

Files

Config File Rows Contents
part_numbers data/part-numbers.csv 13 Primary part numbers with type and brand coverage
cross_reference data/cross-reference.csv 119 Primary number β†’ interchange number mappings
specifications data/specifications.csv 117 Specification fields per part family (long format)
fitment data/fitment.csv 249 Part number β†’ brand β†’ compatible model
comparisons data/comparisons.csv 10 Whether one part can replace another, with the reason

Data model

  • part-numbers.csv: part_number, type, brands, cross_ref_count, reference_page
  • cross-reference.csv: one row per interchange number. Interchange numbers come from distributor tables, not from manufacturer statements. A mapping is a claim about compatibility, not a verification of it.
  • specifications.csv: long format β€” one row per field, so families with different sets of fields stay in one table without sparse columns.
  • fitment.csv: one row per (part, brand, model). Model strings are reproduced as published; some are series names rather than single model codes.
  • comparisons.csv: part_a, part_b, question, short_answer, reference_page β€” the highest-value subset: whether a substitute is safe, and why.

What this dataset is not

  • Not an offer, quotation or availability statement. No row implies a part is in stock at any seller at any price.
  • Not a manufacturer publication. Every cross-reference is reproduced as reported by a distributor or catalog.
  • Not a fitment guarantee. Physical fit does not establish functional equivalence β€” especially for safety devices.
  • Not complete. Fields marked as not published were genuinely absent from the sources checked.

How to use it responsibly

  1. Verify against the equipment's own parts manual before ordering anything.
  2. Treat interchange tables as leads, not answers. If a mapping does not state the dimensions that matter (bulb size, capillary length, reset type, fitting thread), it has not been verified at the level that matters.
  3. Never substitute a safety device on physical fit alone. A hi-limit that is dimensionally close but has the wrong reset behaviour removes a protection layer.

Citation

Xue, Kyle. (2026). Commercial Fryer Parts Cross-Reference Dataset
(Hobart / Vulcan / Wolf / Garland / Frymaster) (Version 1.0) [Data set].
Zenodo. https://doi.org/10.5281/zenodo.23613054
@dataset{xue_2026_fryer_parts,
  author    = {Xue, Kyle},
  title     = {Commercial Fryer Parts Cross-Reference Dataset
               (Hobart / Vulcan / Wolf / Garland / Frymaster)},
  year      = 2026,
  publisher = {Zenodo},
  version   = {1.0},
  doi       = {10.5281/zenodo.23613054},
  url       = {https://doi.org/10.5281/zenodo.23613054}
}

License

Data files are dedicated to the public domain under CC0 1.0.

Downloads last month
43