accuracy stringclasses 3
values | output_type stringclasses 3
values | source_text stringclasses 3
values | response_time stringclasses 3
values | sensing_range stringclasses 3
values | mounting_method stringclasses 3
values |
|---|---|---|---|---|---|
±(0.15 °C + 0.002 × |t|) | Pt100, 3-wire resistance output | RTD Immersion Probe, Model RT-41. Measuring range: -50 to 250 °C. Accuracy: ±(0.15 °C + 0.002 × |t|). Output: Pt100, 3-wire resistance output. Response time: 2 s in water flowing at 0.4 m/s. Mounting: 1/2 in NPT threaded immersion fitting. | 2 s in water flowing at 0.4 m/s | -50 to 250 °C | 1/2 in NPT threaded immersion fitting |
±1.5 °C or ±0.4% of reading, whichever is greater | Type K thermocouple, ungrounded junction | Mineral-insulated thermocouple probe, Model TC-62. Temperature range: -200 to 600 °C. Accuracy: ±1.5 °C or ±0.4% of reading, whichever is greater. Output: Type K thermocouple, ungrounded junction. Response time: 0.8 s in stirred water. Mounting: spring-loaded bayonet fitting with a 1/4 in NPT process connection. | 0.8 s in stirred water | -200 to 600 °C | spring-loaded bayonet fitting with a 1/4 in NPT process connection |
±0.3 °C from 0 to 70 °C | 4–20 mA, two-wire loop-powered | Compact duct temperature transmitter, Model AT-18. Operating temperature range: -20 to 120 °C. Measurement accuracy: ±0.3 °C from 0 to 70 °C. Output signal: 4–20 mA, two-wire loop-powered. Response time: 5 s in air at 1 m/s. Installation: secured to the duct with a flange and two mounting screws. | 5 s in air at 1 m/s | -20 to 120 °C | secured to the duct with a flange and two mounting screws |
Temperature Sensor Product Specification Information Extraction Benchmark
This benchmark uses text from temperature sensor manufacturers' product pages and online technical catalogs as input, with structured reference answers for attributes such as sensing range, accuracy, output type, response time, and mounting method. It supports evaluation of a model's ability to identify and extract specifications from web text, as well as benchmarking, system comparisons, and iterative improvement of information extraction solutions.
Technical Specifications
| Field | Type | Description |
|---|---|---|
| accuracy | string | The stated measurement accuracy or tolerance, preserving the values and units provided in the source. |
| output_type | string | The sensor's output signal type or output interface format. |
| source_text | string | Temperature sensor text from a manufacturer product page or online technical catalog. |
| response_time | string | The response time stated for the product, preserving the values and units provided in the source. |
| sensing_range | string | The temperature range measurable by the sensor, preserving the values and units stated in the source. |
| mounting_method | string | The mounting method supported or required by the product. |
Compliance Statement
| Authorization Type | CC-BY-NC-SA 4.0 (Attribution–NonCommercial–ShareAlike) |
| Commercial Use | Requires exclusive subscription or authorization contract (monthly or per-invocation charging) |
| Privacy and Anonymization | No PII, no real company names, simulated scenarios follow industry standards |
| Compliance System | Compliant with China's Data Security Law / EU GDPR / supports enterprise data access logs |
Source & Contact
- Downloads last month
- -