Datasets:
case_id stringlengths 25 25 | patient_id stringlengths 14 14 | series_uid stringlengths 64 64 | slice_index int32 16 584 | n_slices int32 65 764 | spacing_z float32 0.45 5 | manufacturer stringclasses 4
values | has_seg bool 2
classes | n_nodules int32 0 23 | n_nodules_default int32 0 12 | n_annotations int32 0 49 | in_luna16 bool 2
classes | luna16_subset stringclasses 10
values | in_qin_lungct_seg bool 2
classes | image imagewidth (px) 512 512 | mask imagewidth (px) 512 512 | overlay imagewidth (px) 512 512 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LIDC-IDRI-0001_9720603192 | LIDC-IDRI-0001 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.179049373636438705059720603192 | 89 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset1 | false | |||
LIDC-IDRI-0002_3149104919 | LIDC-IDRI-0002 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.619372068417051974713149104919 | 130 | 261 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 0 | 2 | true | subset3 | false | |||
LIDC-IDRI-0003_3480003264 | LIDC-IDRI-0003 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.170706757615202213033480003264 | 76 | 140 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 3 | 13 | true | subset9 | false | |||
LIDC-IDRI-0004_2212458228 | LIDC-IDRI-0004 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.323541312620128092852212458228 | 76 | 241 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset3 | false | |||
LIDC-IDRI-0005_7836686225 | LIDC-IDRI-0005 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.129007566048223160327836686225 | 80 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 2 | 9 | true | subset6 | false | |||
LIDC-IDRI-0006_7924920957 | LIDC-IDRI-0006 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.132817748896065918417924920957 | 84 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 1 | 8 | true | subset5 | false | |||
LIDC-IDRI-0007_8330857680 | LIDC-IDRI-0007 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.272348349298439120568330857680 | 109 | 145 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | true | subset7 | false | |||
LIDC-IDRI-0008_2229821954 | LIDC-IDRI-0008 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.774060103415303828812229821954 | 88 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 2 | 7 | true | subset8 | false | |||
LIDC-IDRI-0009_6912429210 | LIDC-IDRI-0009 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.286061375572911414226912429210 | 128 | 256 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 0 | 2 | true | subset9 | false | |||
LIDC-IDRI-0010_2405866796 | LIDC-IDRI-0010 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.416701701108520592702405866796 | 210 | 277 | 1.25 | GE MEDICAL SYSTEMS | true | 3 | 1 | 7 | true | subset6 | false | |||
LIDC-IDRI-0011_6468423138 | LIDC-IDRI-0011 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.140253591510022414496468423138 | 104 | 128 | 2.5 | GE MEDICAL SYSTEMS | true | 10 | 3 | 23 | true | subset7 | false | |||
LIDC-IDRI-0012_3438457842 | LIDC-IDRI-0012 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.328789598898469177563438457842 | 64 | 128 | 2.5 | GE MEDICAL SYSTEMS | true | 12 | 9 | 36 | true | subset7 | false | |||
LIDC-IDRI-0013_2640380786 | LIDC-IDRI-0013 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.174907798609768549012640380786 | 90 | 125 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 2 | 10 | true | subset5 | false | |||
LIDC-IDRI-0014_7626507402 | LIDC-IDRI-0014 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.747803439040091794717626507402 | 74 | 114 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset9 | false | |||
LIDC-IDRI-0015_6960828223 | LIDC-IDRI-0015 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.227962600322799211676960828223 | 180 | 209 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset0 | false | |||
LIDC-IDRI-0016_3134773630 | LIDC-IDRI-0016 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.153536305742006952753134773630 | 74 | 141 | 2.5 | GE MEDICAL SYSTEMS | true | 6 | 5 | 21 | true | subset2 | false | |||
LIDC-IDRI-0017_4210228428 | LIDC-IDRI-0017 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.108231420525711026834210228428 | 162 | 238 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset1 | false | |||
LIDC-IDRI-0018_1854510592 | LIDC-IDRI-0018 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.882070241245008756731854510592 | 109 | 127 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 4 | 14 | true | subset8 | false | |||
LIDC-IDRI-0019_2846006585 | LIDC-IDRI-0019 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.330425234131526435132846006585 | 152 | 305 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 0 | 2 | true | subset4 | false | |||
LIDC-IDRI-0020_6518747372 | LIDC-IDRI-0020 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.315214756157389122376518747372 | 190 | 225 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | true | subset1 | false | |||
LIDC-IDRI-0021_6515802868 | LIDC-IDRI-0021 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.188265424231150847356515802868 | 126 | 149 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 1 | 6 | true | subset5 | false | |||
LIDC-IDRI-0022_6219450076 | LIDC-IDRI-0022 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.296863826932699509516219450076 | 66 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 0 | 1 | true | subset2 | false | |||
LIDC-IDRI-0023_6016826588 | LIDC-IDRI-0023 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.487745546557477250336016826588 | 118 | 137 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset3 | false | |||
LIDC-IDRI-0024_7954580114 | LIDC-IDRI-0024 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.206028343897359374907954580114 | 72 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 3 | 12 | true | subset8 | false | |||
LIDC-IDRI-0025_7542153557 | LIDC-IDRI-0025 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.564534197011295112247542153557 | 132 | 265 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 0 | 1 | true | subset0 | false | |||
LIDC-IDRI-0026_7858840086 | LIDC-IDRI-0026 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.101228986346984399347858840086 | 128 | 257 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 0 | 3 | true | subset5 | false | |||
LIDC-IDRI-0027_7192412456 | LIDC-IDRI-0027 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.183843376225716802567192412456 | 77 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 7 | 4 | 19 | true | subset1 | false | |||
LIDC-IDRI-0028_7298352671 | LIDC-IDRI-0028 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.203741923654363010377298352671 | 70 | 141 | 2.5 | GE MEDICAL SYSTEMS | false | 0 | 0 | 0 | true | subset3 | false | |||
LIDC-IDRI-0029_7322794314 | LIDC-IDRI-0029 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.264090899378396711987322794314 | 136 | 273 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 0 | 1 | true | subset3 | false | |||
LIDC-IDRI-0030_3829243183 | LIDC-IDRI-0030 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.986011151772797848993829243183 | 59 | 119 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 0 | 4 | true | subset5 | false | |||
LIDC-IDRI-0031_0085460568 | LIDC-IDRI-0031 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.124663713663969377020085460568 | 113 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 5 | 3 | 14 | true | subset2 | false | |||
LIDC-IDRI-0032_8092691689 | LIDC-IDRI-0032 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.803808126682275425758092691689 | 124 | 249 | 1.25 | GE MEDICAL SYSTEMS | false | 0 | 0 | 0 | true | subset2 | false | |||
LIDC-IDRI-0033_3177283490 | LIDC-IDRI-0033 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.513023675145166449943177283490 | 106 | 137 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | true | subset6 | false | |||
LIDC-IDRI-0034_2824032832 | LIDC-IDRI-0034 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.338447145504282422142824032832 | 97 | 265 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 3 | true | subset6 | false | |||
LIDC-IDRI-0035_2951898613 | LIDC-IDRI-0035 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.161002239822118346732951898613 | 66 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 0 | 2 | true | subset1 | false | |||
LIDC-IDRI-0036_4514718990 | LIDC-IDRI-0036 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.177685820605315926524514718990 | 201 | 273 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | true | subset3 | false | |||
LIDC-IDRI-0037_9438012179 | LIDC-IDRI-0037 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.219909753224298157409438012179 | 83 | 141 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 2 | 7 | true | subset0 | false | |||
LIDC-IDRI-0038_9083782428 | LIDC-IDRI-0038 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.117383608379722740629083782428 | 66 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 0 | 1 | true | subset2 | false | |||
LIDC-IDRI-0039_2521201463 | LIDC-IDRI-0039 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.332829333783605240302521201463 | 174 | 281 | 1.25 | GE MEDICAL SYSTEMS | true | 5 | 5 | 20 | true | subset7 | false | |||
LIDC-IDRI-0040_8175033640 | LIDC-IDRI-0040 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.272961322147784625028175033640 | 43 | 121 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 1 | 7 | true | subset1 | false | |||
LIDC-IDRI-0041_8313387015 | LIDC-IDRI-0041 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.138813197521718693188313387015 | 48 | 149 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 1 | 7 | true | subset9 | false | |||
LIDC-IDRI-0042_8346920341 | LIDC-IDRI-0042 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.280125803152924778388346920341 | 48 | 123 | 2.5 | GE MEDICAL SYSTEMS | true | 10 | 3 | 22 | true | subset7 | false | |||
LIDC-IDRI-0043_1509831276 | LIDC-IDRI-0043 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.503980049263254396021509831276 | 91 | 113 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 3 | 10 | true | subset1 | false | |||
LIDC-IDRI-0044_5216493273 | LIDC-IDRI-0044 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.511347030803753100045216493273 | 68 | 147 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 3 | 13 | true | subset0 | false | |||
LIDC-IDRI-0045_0711078950 | LIDC-IDRI-0045 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.910435939545691201820711078950 | 84 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 12 | 7 | 33 | true | subset4 | false | |||
LIDC-IDRI-0046_3065566972 | LIDC-IDRI-0046 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.122914038048856168343065566972 | 41 | 128 | 2.5 | GE MEDICAL SYSTEMS | true | 7 | 6 | 21 | true | subset4 | false | |||
LIDC-IDRI-0047_9943280992 | LIDC-IDRI-0047 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.338114620394879648539943280992 | 76 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset5 | false | |||
LIDC-IDRI-0048_8828903732 | LIDC-IDRI-0048 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.250863365157630276148828903732 | 189 | 297 | 1.25 | GE MEDICAL SYSTEMS | true | 3 | 1 | 7 | true | subset0 | false | |||
LIDC-IDRI-0049_9913775427 | LIDC-IDRI-0049 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.239358021703233250639913775427 | 67 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 15 | 8 | 39 | true | subset8 | false | |||
LIDC-IDRI-0050_7312236359 | LIDC-IDRI-0050 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.183982839679953938397312236359 | 94 | 139 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset8 | false | |||
LIDC-IDRI-0051_4892222907 | LIDC-IDRI-0051 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.779493719385047675154892222907 | 79 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 2 | 9 | true | subset4 | false | |||
LIDC-IDRI-0052_1988320084 | LIDC-IDRI-0052 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.126631670596873065041988320084 | 227 | 272 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 2 | 8 | true | subset3 | false | |||
LIDC-IDRI-0053_9390459071 | LIDC-IDRI-0053 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.300136985030081433029390459071 | 35 | 111 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 2 | 8 | true | subset8 | false | |||
LIDC-IDRI-0054_3093760291 | LIDC-IDRI-0054 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.174449669706458092793093760291 | 85 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset9 | false | |||
LIDC-IDRI-0055_4741039150 | LIDC-IDRI-0055 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.214252223927572015414741039150 | 121 | 139 | 2.5 | GE MEDICAL SYSTEMS | true | 7 | 3 | 20 | true | subset7 | false | |||
LIDC-IDRI-0056_6362698069 | LIDC-IDRI-0056 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.161067514225109999586362698069 | 78 | 245 | 1.25 | GE MEDICAL SYSTEMS | true | 3 | 3 | 10 | true | subset6 | false | |||
LIDC-IDRI-0057_4167856951 | LIDC-IDRI-0057 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.252634638822000832774167856951 | 160 | 245 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset2 | false | |||
LIDC-IDRI-0058_8873200770 | LIDC-IDRI-0058 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.323408652979949774528873200770 | 69 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 2 | 9 | true | subset5 | false | |||
LIDC-IDRI-0059_2378348912 | LIDC-IDRI-0059 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.128023902651233986592378348912 | 101 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset0 | false | |||
LIDC-IDRI-0060_7913355115 | LIDC-IDRI-0060 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.463214953282361219537913355115 | 40 | 115 | 2.5 | GE MEDICAL SYSTEMS | true | 6 | 2 | 13 | true | subset4 | false | |||
LIDC-IDRI-0061_7019247886 | LIDC-IDRI-0061 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.287966244644280690737019247886 | 90 | 123 | 2.5 | GE MEDICAL SYSTEMS | true | 6 | 5 | 19 | true | subset1 | false | |||
LIDC-IDRI-0062_5178209430 | LIDC-IDRI-0062 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.210426531621179400035178209430 | 58 | 117 | 2.5 | GE MEDICAL SYSTEMS | false | 0 | 0 | 0 | true | subset3 | false | |||
LIDC-IDRI-0063_2079081128 | LIDC-IDRI-0063 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.272190966764020277652079081128 | 67 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 4 | 2 | 10 | true | subset3 | false | |||
LIDC-IDRI-0064_2433148666 | LIDC-IDRI-0064 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.487268565754493433372433148666 | 78 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 2 | 8 | true | subset8 | false | |||
LIDC-IDRI-0065_2166468085 | LIDC-IDRI-0065 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.163217526257871051722166468085 | 118 | 237 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 0 | 2 | true | subset7 | false | |||
LIDC-IDRI-0066_6148200410 | LIDC-IDRI-0066 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.430109407146633213496148200410 | 584 | 733 | 0.5 | SIEMENS | true | 3 | 3 | 11 | true | subset0 | false | |||
LIDC-IDRI-0067_2900221600 | LIDC-IDRI-0067 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.228511122591230092662900221600 | 114 | 244 | 1.25 | GE MEDICAL SYSTEMS | true | 4 | 3 | 14 | true | subset4 | false | |||
LIDC-IDRI-0068_6286626125 | LIDC-IDRI-0068 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.187108608022306504546286626125 | 216 | 261 | 1.25 | GE MEDICAL SYSTEMS | true | 6 | 5 | 22 | true | subset2 | false | |||
LIDC-IDRI-0069_6154504249 | LIDC-IDRI-0069 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.131939324905446238286154504249 | 83 | 136 | 2 | TOSHIBA | true | 3 | 2 | 9 | true | subset8 | false | |||
LIDC-IDRI-0070_9737454720 | LIDC-IDRI-0070 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.178391668569567816549737454720 | 79 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 1 | 7 | true | subset5 | false | |||
LIDC-IDRI-0071_4833254861 | LIDC-IDRI-0071 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.290410217650314119074833254861 | 130 | 261 | 1.25 | GE MEDICAL SYSTEMS | false | 0 | 0 | 0 | true | subset6 | false | |||
LIDC-IDRI-0072_7655488650 | LIDC-IDRI-0072 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.153985109349433321657655488650 | 256 | 305 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 3 | true | subset9 | false | |||
LIDC-IDRI-0073_5868125932 | LIDC-IDRI-0073 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.279300249795483097365868125932 | 110 | 131 | 2.5 | GE MEDICAL SYSTEMS | true | 3 | 1 | 7 | true | subset7 | false | |||
LIDC-IDRI-0074_6232944897 | LIDC-IDRI-0074 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.339546614783708685476232944897 | 79 | 109 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 3 | true | subset4 | false | |||
LIDC-IDRI-0075_5592995222 | LIDC-IDRI-0075 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.177086402277715068525592995222 | 161 | 257 | 1.25 | GE MEDICAL SYSTEMS | true | 4 | 2 | 9 | true | subset8 | false | |||
LIDC-IDRI-0076_0333093071 | LIDC-IDRI-0076 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.479402560265137632920333093071 | 76 | 297 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 2 | 8 | true | subset1 | false | |||
LIDC-IDRI-0077_2318480131 | LIDC-IDRI-0077 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.669435869708883155232318480131 | 73 | 130 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | true | subset6 | false | |||
LIDC-IDRI-0078_4852353824 | LIDC-IDRI-0078 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.303494235102183795724852353824 | 67 | 87 | 3 | TOSHIBA | true | 4 | 3 | 13 | false | null | false | |||
LIDC-IDRI-0079_5724605159 | LIDC-IDRI-0079 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.213233719488315954975724605159 | 69 | 113 | 3 | TOSHIBA | true | 1 | 1 | 4 | false | null | false | |||
LIDC-IDRI-0080_4630781782 | LIDC-IDRI-0080 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.613212850444255764524630781782 | 98 | 257 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 2 | 7 | true | subset7 | false | |||
LIDC-IDRI-0081_4757844726 | LIDC-IDRI-0081 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.172243743899615313644757844726 | 96 | 126 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 2 | 7 | true | subset8 | false | |||
LIDC-IDRI-0082_4022644822 | LIDC-IDRI-0082 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.652347820272212119124022644822 | 171 | 242 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 3 | true | subset6 | false | |||
LIDC-IDRI-0083_1247860532 | LIDC-IDRI-0083 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.204287915902811325371247860532 | 116 | 218 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 2 | 7 | true | subset8 | false | |||
LIDC-IDRI-0084_4642979503 | LIDC-IDRI-0084 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.288701997968615460794642979503 | 56 | 166 | 2 | TOSHIBA | true | 6 | 3 | 13 | true | subset8 | false | |||
LIDC-IDRI-0085_1600846659 | LIDC-IDRI-0085 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.156990013635454707781600846659 | 125 | 267 | 1.25 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | false | null | false | |||
LIDC-IDRI-0086_0879444879 | LIDC-IDRI-0086 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.145580766024236783540879444879 | 123 | 246 | 1.5 | SIEMENS | true | 1 | 0 | 2 | false | null | false | |||
LIDC-IDRI-0087_4244485809 | LIDC-IDRI-0087 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.194632613233275988184244485809 | 107 | 130 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 1 | 4 | true | subset9 | false | |||
LIDC-IDRI-0088_0336702075 | LIDC-IDRI-0088 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.113679818447732724990336702075 | 74 | 241 | 1.25 | GE MEDICAL SYSTEMS | true | 3 | 3 | 10 | true | subset7 | false | |||
LIDC-IDRI-0089_5399155268 | LIDC-IDRI-0089 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.146987333806092287055399155268 | 49 | 147 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset4 | false | |||
LIDC-IDRI-0090_6013446707 | LIDC-IDRI-0090 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.733642690503782454656013446707 | 100 | 133 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 4 | true | subset9 | false | |||
LIDC-IDRI-0091_4024478441 | LIDC-IDRI-0091 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.134996872583497382954024478441 | 159 | 197 | 1.25 | GE MEDICAL SYSTEMS | true | 5 | 4 | 17 | true | subset0 | false | |||
LIDC-IDRI-0092_8717203667 | LIDC-IDRI-0092 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.286217539434358186648717203667 | 178 | 241 | 1.25 | GE MEDICAL SYSTEMS | true | 4 | 3 | 13 | true | subset6 | false | |||
LIDC-IDRI-0093_0110762069 | LIDC-IDRI-0093 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.227707494413800460340110762069 | 56 | 125 | 2.5 | GE MEDICAL SYSTEMS | true | 2 | 1 | 5 | true | subset7 | false | |||
LIDC-IDRI-0094_9469324839 | LIDC-IDRI-0094 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.143622857676008763729469324839 | 300 | 385 | 1 | SIEMENS | true | 1 | 1 | 4 | true | subset8 | false | |||
LIDC-IDRI-0095_5286615668 | LIDC-IDRI-0095 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.137773550852881583165286615668 | 194 | 343 | 1 | SIEMENS | true | 3 | 2 | 9 | true | subset8 | false | |||
LIDC-IDRI-0096_3889983845 | LIDC-IDRI-0096 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.310548927038333190233889983845 | 109 | 127 | 2.5 | GE MEDICAL SYSTEMS | true | 1 | 1 | 3 | true | subset0 | false | |||
LIDC-IDRI-0097_0165935891 | LIDC-IDRI-0097 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.461155505515403114280165935891 | 112 | 245 | 1.25 | GE MEDICAL SYSTEMS | true | 1 | 1 | 3 | true | subset2 | false | |||
LIDC-IDRI-0098_7777745271 | LIDC-IDRI-0098 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.286524966129599998397777745271 | 74 | 104 | 3 | SIEMENS | true | 1 | 1 | 3 | false | null | false | |||
LIDC-IDRI-0099_8946053237 | LIDC-IDRI-0099 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.931383239747372227838946053237 | 44 | 194 | 1.25 | GE MEDICAL SYSTEMS | true | 4 | 2 | 9 | true | subset8 | false | |||
LIDC-IDRI-0100_3059698181 | LIDC-IDRI-0100 | 1.3.6.1.4.1.14519.5.2.1.6279.6001.622243923620914676263059698181 | 134 | 269 | 1.25 | GE MEDICAL SYSTEMS | false | 0 | 0 | 0 | true | subset8 | false |
LIDC-IDRI — lung nodule segmentation on chest CT (complete TCIA collection, NIfTI)
The Lung Image Database Consortium / Image Database Resource Initiative collection: 1,010 patients / 1,018 chest CT scans / 243,958 slices with the four-radiologist nodule (≥ 3 mm) contours, re-hosted as NIfTI with per-annotation masks and a documented default ground truth. Source images: TCIA collection LIDC-IDRI (doi:10.7937/K9/TCIA.2015.LO9QL9SX). Source annotations: the QIICR DICOM-SEG/SR re-encoding DICOM-LIDC-IDRI-Nodules (doi:10.7937/TCIA.2018.h7umfurq). Both CC BY 3.0.
This mirror supersedes and absorbs a planned separate DICOM-LIDC-IDRI-Nodules
dataset: same annotations, same TrackingUID clustering, over the 883-scan subset that
carries contours. Never count the two as independent benchmarks.
What is here
| path | content |
|---|---|
images/<case>.nii.gz |
CT in Hounsfield units, int16, native geometry (1,018) |
masks/<case>.nii.gz |
default ground truth, uint8 {0,1}: nodules with ≥ 3 annotations at ≥ 50 % consensus of their annotations |
masks_instance/<case>.nii.gz |
uint16 nodule id (per scan) for every clustered nodule at 50 % consensus |
masks_annotation_count/<case>.nii.gz |
uint8 number of annotations covering each voxel |
masks_annotation/<case>/<case>_nodNN_annK.nii.gz |
one uint8 mask per DICOM-SEG object (6,859) — lossless w.r.t. the source |
scans.csv |
one row per scan: geometry, manufacturer, transfer syntax, duplicate-z slices dropped, nodule/annotation counts, in_luna16, luna16_subset, in_qin_lungct_seg |
nodules.csv |
one row per clustered nodule (2,651): n_annotations, in_default_gt, consensus/union/intersection voxels, bbox, centroid, median SR characteristics (subtlety … malignancy, volume, diameter) |
annotations.csv |
one row per SEG object with its SR characteristics and mask path |
train.jsonl |
loader manifest, one row per scan (single train split — no official split exists) |
aux/ |
LIDC-XML-only.zip (the original XML reads incl. < 3 mm and non-nodule point marks), LIDC-IDRI_MetaData.csv, nodule-count and diagnosis sheets, verbatim from TCIA |
preview config |
one PNG per scan (the slice with the most default-GT foreground, or the middle slice) with mask and overlay, for the Dataset Viewer |
<case> = <PatientID>_<10-char SeriesInstanceUID suffix>; eight patients have two scans
(LIDC-IDRI-0132/0151/0315/0332/0355/0365/0442/0484) — group on patient_id.
Not mirrored: the collection's 290 chest radiographs (DX/CR, no annotations) and the 90
3D Slicer Community SEG objects served under the same collection name (QIN CT-challenge
algorithm outputs on 10 patients, already in MedOtter/QIN-LungCT-Seg).
Ground truth
Each scan was read by four thoracic radiologists (blinded, then unblinded; no forced consensus). Only nodules ≥ 3 mm were outlined. Upstream ships no consensus mask — each SEG object is one annotation of one nodule, and reader identity "was intentionally not exposed by the LIDC initiative" (Fedorov et al. 2020), so counts here are of annotations (a nodule carries 1–8; distribution over 2,651 nodules: 1 × 771, 2 × 488, 3 × 481, 4 × 897, 5 × 8, 6 × 2, 7 × 3, 8 × 1).
- Default (
masks/): nodule included when ≥ 3 annotations exist (the LUNA16 reference-standard rule); voxel included when ≥ 50 % of that nodule's annotations include it (pylidcconsensus(clevel=0.5)). Keeps 1,392 nodules; 1–2-annotation nodules are background here. 135 scans have no contour at all (real all-zero masks). - Any other tier is reconstructible from
masks_annotation/(+nodules.csv) or frommasks_annotation_count/+masks_instance/.
Overlap with other datasets
LUNA16 is a strict subset: all 888 LUNA16 scans are LIDC-IDRI series (the LUNA16
.mhd name is the SeriesInstanceUID) — see in_luna16 / luna16_subset. LUNA16's nodule
masks are sphere approximations; these are the real contours. QIN-LungCT-Seg shares 10
series (in_qin_lungct_seg). Also LIDC-derived elsewhere: SAROS, CADS 0016_lidc,
Pulmonary-Nodules-Segmentation, ULS23 (upstream), LUNA22-ISMI, NoduleMNIST3D. Dedup on
series_uid.
Provenance and quirks
- DICOM instances pulled from NCI Imaging Data Commons (v24, public S3) — byte-identical to
TCIA's; every series verified against the NBIA
ImageCount. - Five series carried duplicate-z slices (0085, 0146, 0418, 0572, 0979): the first slice
at each z is kept and SEG frames referencing the twin are composited onto it
(
n_duplicate_slices_dropped). z_gap_min/z_gap_maxexpose irregular slice spacing;transfer_syntaxrecords JPEG-compressed series (decoded with GDCM).
License and attribution
CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) — stated on the TCIA collection
page for the images and every annotation row, on the DICOM-LIDC-IDRI-Nodules page, and in
the LicenseName of every series. Mirrored under TCIA's Data Usage Policy
(https://www.cancerimagingarchive.net/data-usage-policies-and-restrictions/): attribute,
link the policy, do not attempt re-identification.
Please cite:
- Armato SG III, McLennan G, Bidaut L, et al. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A completed reference database of lung nodules on CT scans. Medical Physics 38(2):915–931, 2011. doi:10.1118/1.3528204
- Armato SG III, et al. Data From LIDC-IDRI. The Cancer Imaging Archive, 2015. doi:10.7937/K9/TCIA.2015.LO9QL9SX
- Fedorov A, Hancock M, Clunie D, et al. DICOM re-encoding of volumetrically annotated Lung Imaging Database Consortium (LIDC) nodules. Medical Physics 47(11):5953–5965, 2020. doi:10.1002/mp.14445; data doi:10.7937/TCIA.2018.h7umfurq
- Clark K, et al. The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. J Digit Imaging 26(6):1045–1057, 2013.
Acknowledgement required by the collection: "The authors acknowledge the National Cancer Institute and the Foundation for the National Institutes of Health, and their critical role in the creation of the free publicly available LIDC/IDRI Database used in this study."
- Downloads last month
- 21,142