Datasets:
category stringclasses 12
values | messages listlengths 3 3 |
|---|---|
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the cooling load result."
},
{
"role": "assistant",
"content": "I should not gue... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need footing safety, just estimate it."
},
{
"role": "assistant",
"content": "This is ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need pump selection, just estimate it."
},
{
"role": "assistant",
"content": "This is ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate pump selection."
},
{
"role": "assistant",
"content": "This is missing key eng... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check this airflow conversion: 1003 m³/h = 1003 m³/s."
},
{
"role": "assistant",
"conten... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 67 m pump head be enough for a tall building?"
},
{
"role": "assistant",
"content"... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 10.5 m/s is reasonable for hydronic piping."
},
{
"role": "assistant",
"content... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size pipe diameter for me?"
},
{
"role": "assistant",
"content": "I cannot calcu... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 34 m²."
},
{
"role": "assistant",
"content":... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can a pump with only 21 m head serve a high-rise tower?"
},
{
"role": "assistant",
"cont... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Change 32.52 kW into W."
},
{
"role": "assistant",
"content": "1 kW = 1000 W, so 32.52 k... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I think 393 m³/h and 393 m³/s are identical."
},
{
"role": "assistant",
"content": "No. ... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Compare 397 Pa and 325 Pa pressure loss."
},
{
"role": "assistant",
"content": "The high... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Change 40.17 kW into W."
},
{
"role": "assistant",
"content": "1 kW = 1000 W, so 40.17 k... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size slab thickness for me?"
},
{
"role": "assistant",
"content": "There is not ... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check this unit conversion: 5580 m³/h = 5580 m³/s."
},
{
"role": "assistant",
"content":... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 20.3 m/s acceptable for office HVAC ducts?"
},
{
"role": "assistant",
"content": "20.... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 15138 m³/h to L/s."
},
{
"role": "assistant",
"content": "1 L/s = 3.6 m³/h, so 1... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size pipe diameter for me?"
},
{
"role": "assistant",
"content": "There is not e... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 30 m head is realistic for a high-rise system."
},
{
"role": "assistant",
"cont... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "4.13 kPa equals how many Pa?"
},
{
"role": "assistant",
"content": "4.13 kPa × 1000 = 4.... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is chilled water delta-T of 1.25°C normal?"
},
{
"role": "assistant",
"content": "1.25°C... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow."
},
{
"role": "assistant",
"content": "I should not guess ACH air... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The footing pressure is larger than allowable bearing. That means safer, correct?"
},
{
"rol... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "What is 4.586 m³/s in m³/h?"
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is chilled water delta-T of 1.11°C normal?"
},
{
"role": "assistant",
"content": "That d... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need ACH airflow, just estimate it."
},
{
"role": "assistant",
"content": "I cannot ca... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Compare 340 Pa and 575 Pa pressure loss."
},
{
"role": "assistant",
"content": "The grea... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find pump selection without more data."
},
{
"role": "assistant",
"content": "There is n... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 21 m²."
},
{
"role": "assistant",
"content":... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size duct diameter for me?"
},
{
"role": "assistant",
"content": "I should not g... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Change 971 L/s into m³/h for airflow."
},
{
"role": "assistant",
"content": "1 L/s = 3.6... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate fan selection."
},
{
"role": "assistant",
"content": "I should not guess fan s... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "ACH airflow can be found from floor area alone, right?"
},
{
"role": "assistant",
"conte... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "9878 m³/h equals 9878 m³/s, right?"
},
{
"role": "assistant",
"content": "m³/h and m³/s ... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 14.0 m/s is reasonable for ventilation ductwork."
},
{
"role": "assistant",
"co... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The smaller pressure drop is more severe, correct? Compare 497 Pa and 314 Pa."
},
{
"role": ... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 14.6% voltage drop normal for a building circuit?"
},
{
"role": "assistant",
"content... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size footing safety for me?"
},
{
"role": "assistant",
"content": "This is missi... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 0.66°C chilled water delta-T be acceptable?"
},
{
"role": "assistant",
"content": ... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 8.9 m/s is reasonable for hydronic piping."
},
{
"role": "assistant",
"content"... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need pipe diameter, just estimate it."
},
{
"role": "assistant",
"content": "There is ... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "3337 m³/h is how many L/s?"
},
{
"role": "assistant",
"content": "1 L/s = 3.6 m³/h, so 3... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The footing pressure is larger than allowable bearing. That means safer, correct?"
},
{
"rol... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate beam sizing."
},
{
"role": "assistant",
"content": "I should not guess beam si... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate ACH airflow using only floor area 23 m²."
},
{
"role": "assistant",
"content":... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 7.916 m³/s to m³/h."
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Size a round duct for 15155 m³/h at 4.0 m/s using D = sqrt(4V²Q/pi)."
},
{
"role": "assistan... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need beam sizing, just estimate it."
},
{
"role": "assistant",
"content": "I cannot ca... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "What is 6.887 m³/s in m³/h?"
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 39.0 m/s acceptable for office HVAC ducts?"
},
{
"role": "assistant",
"content": "39.... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 42.9 m/s duct velocity be normal in an office?"
},
{
"role": "assistant",
"content... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate voltage drop."
},
{
"role": "assistant",
"content": "There is not enough infor... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 29.93 kW to W."
},
{
"role": "assistant",
"content": "1 kW = 1000 W, so 29.93 kW... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "The smaller pressure drop is more severe, correct? Compare 532 Pa and 147 Pa."
},
{
"role": ... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "A voltage drop of 12.8% is acceptable, right?"
},
{
"role": "assistant",
"content": "12.... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need pump selection, just estimate it."
},
{
"role": "assistant",
"content": "I cannot... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 10.21 kPa to Pa."
},
{
"role": "assistant",
"content": "10.21 kPa × 1000 = 1.02e... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size beam sizing for me?"
},
{
"role": "assistant",
"content": "There is not eno... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 4 m pump head be enough for a tall building?"
},
{
"role": "assistant",
"content":... |
sanity_pump_head | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can a pump with only 64 m head serve a high-rise tower?"
},
{
"role": "assistant",
"cont... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the pipe diameter result."
},
{
"role": "assistant",
"content": "There is not en... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate beam sizing."
},
{
"role": "assistant",
"content": "This is missing key engine... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is chilled water delta-T of 1.13°C normal?"
},
{
"role": "assistant",
"content": "That d... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "For HVAC airflow, convert 16611 m³/h into m³/s."
},
{
"role": "assistant",
"content": "1... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 7.1 m/s pipe velocity be normal?"
},
{
"role": "assistant",
"content": "7.1 m/s is... |
sanity_delta_t | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 0.77°C is a realistic HVAC water delta-T."
},
{
"role": "assistant",
"content":... |
sanity_pipe_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 10.2 m/s pipe velocity be normal?"
},
{
"role": "assistant",
"content": "That velo... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Which pressure drop is worse: 37 Pa or 598 Pa?"
},
{
"role": "assistant",
"content": "La... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Convert 7.905 m³/s to m³/h."
},
{
"role": "assistant",
"content": "To convert m³/s to m³... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 16.8 m/s acceptable for office HVAC ducts?"
},
{
"role": "assistant",
"content": "16.... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need ACH airflow, just estimate it."
},
{
"role": "assistant",
"content": "I should no... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find ACH airflow without more data."
},
{
"role": "assistant",
"content": "This is missi... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is 12.4% voltage drop normal for a building circuit?"
},
{
"role": "assistant",
"content... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 37.9 m/s is reasonable for ventilation ductwork."
},
{
"role": "assistant",
"co... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can you size ACH airflow for me?"
},
{
"role": "assistant",
"content": "I cannot calcula... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find footing safety without more data."
},
{
"role": "assistant",
"content": "I cannot c... |
sanity_velocity | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Would 30.5 m/s duct velocity be normal in an office?"
},
{
"role": "assistant",
"content... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Can I use D = sqrt(4V²Q/pi) for HVAC duct sizing with 1744 m³/h and 8.7 m/s?"
},
{
"role": "... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the pump selection result."
},
{
"role": "assistant",
"content": "There is not e... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Compare 232 Pa and 282 Pa pressure loss."
},
{
"role": "assistant",
"content": "Larger p... |
correction_missing_volume | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I only have room area 104 m² and 7 ACH. Calculate airflow."
},
{
"role": "assistant",
"c... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need pipe diameter, just estimate it."
},
{
"role": "assistant",
"content": "There is ... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find fan selection without more data."
},
{
"role": "assistant",
"content": "I should no... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Compare 285 Pa and 261 Pa pressure loss."
},
{
"role": "assistant",
"content": "Larger p... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the duct diameter result."
},
{
"role": "assistant",
"content": "I cannot calcul... |
sanity_voltage_drop | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check if 8.2% voltage drop is okay."
},
{
"role": "assistant",
"content": "8.2% voltage ... |
correction_comparison_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Is a footing safe when 140 kPa exceeds 287 kPa?"
},
{
"role": "assistant",
"content": "H... |
correction_unit_error | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I think 3219 m³/h and 3219 m³/s are identical."
},
{
"role": "assistant",
"content": "No... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Calculate slab thickness."
},
{
"role": "assistant",
"content": "There is not enough inf... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need pipe diameter, just estimate it."
},
{
"role": "assistant",
"content": "I should ... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Which pressure drop is worse: 403 Pa or 32 Pa?"
},
{
"role": "assistant",
"content": "Th... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "I need cooling load, just estimate it."
},
{
"role": "assistant",
"content": "This is mi... |
correction_wrong_formula | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Check this duct equation only: D = sqrt(4V²Q/pi). No airflow or velocity values are given."
},
{... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find cooling load without more data."
},
{
"role": "assistant",
"content": "I should not... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Find pump selection without more data."
},
{
"role": "assistant",
"content": "I should n... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the footing safety result."
},
{
"role": "assistant",
"content": "There is not e... |
correction_pressure_logic | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Which pressure drop is worse: 246 Pa or 200 Pa?"
},
{
"role": "assistant",
"content": "T... |
missing_input_refusal | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Give me the fan selection result."
},
{
"role": "assistant",
"content": "This is missing... |
unit_conversion | [
{
"role": "system",
"content": "You are a careful building engineering assistant. Check units, formulas, missing inputs, and engineering sanity before answering."
},
{
"role": "user",
"content": "Change 94.05 kW into W."
},
{
"role": "assistant",
"content": "1 kW = 1000 W, so 94.05 k... |
license: apache-2.0 language: - en pipeline_tag: text-generation tags: - engineering - hvac - building-engineering - lora - qwen - synthetic-data - reasoning base_model: - Qwen/Qwen2.5-1.5B-Instruct
Qwen2.5-1.5B BuildEng V7
Repository: Irfanuruchi/qwen2.5-1.5b-buildeng-v7-lora
This model is a building-engineering focused LoRA fine-tune of Qwen2.5-1.5B-Instruct.
V7 was made to move away from only direct engineering calculations and push the model more toward engineering reasoning behavior. Earlier versions could solve formulas, but still sometimes accepted wrong assumptions, bad unit conversions, unrealistic HVAC values, or incomplete design prompts.
The main goal of V7 was making the model more careful instead of just making it sound technical.
What Was Used
Base model:
Qwen/Qwen2.5-1.5B-Instruct
Training method:
LoRA fine-tuning with Unsloth
Dataset used:
buildeng-v7-15k
The dataset was generated using custom Python generators focused on engineering calculations, sanity checks, formula correction, and refusal behavior.
Main Focus Of V7
V7 focuses heavily on:
HVAC airflow reasoning, unit consistency, m³/h to m³/s conversion, duct sizing logic, formula correction. Engineering sanity checks, missing-input refusal behavior, ventilation reasoning and basic structural comparison logic
One major focus was teaching the model to stop giving confident answers when engineering inputs are incomplete.
For example, the model is trained to avoid:
• accepting wrong duct equations
• calculating ACH airflow from floor area only
• accepting unrealistic HVAC velocities
• guessing missing values
• confusing airflow units
Example Behavior
Example:
User:
7200 m³/h equals 7200 m³/s, right?
Assistant:
No. 7200 m³/h ÷ 3600 = 2 m³/s.
Another example:
User:
Calculate duct diameter.
Assistant:
More information is required before sizing the duct. Airflow and target velocity are needed.
Engineering Areas
The model was trained mainly around simplified building-engineering reasoning tasks including:
HVAC airflow calculations, duct sizing, ventilation logic, pressure reasoning
Hydronic sanity checks, footing pressure comparison, engineering unit conversion, missing-input engineering prompts
Limitations
This model is not a replacement for professional engineering software or real engineering review.
The training data is synthetic and simplified. Full ASHRAE, Eurocode, or professional design standards are not fully implemented.
Outputs should always be checked by a qualified engineer.
The model can still make arithmetic mistakes or produce incorrect engineering assumptions in some cases, especially on more complex problems.
Future Improvements
V7 is an intermediate version before larger datasets and stronger engineering models.
Future work includes:
• larger datasets
• stronger arithmetic consistency
• multi-turn engineering reasoning
• more structural engineering examples
• better HVAC design workflows
• larger engineering-specialized models including 32B systems
Training Notes
One interesting part during V7 development was that failed model outputs were analyzed and then turned into new repair-focused synthetic samples. For example, if the model repeatedly failed m³/h conversions or accepted bad duct formulas, additional targeted repair samples were added into later dataset versions. This made the tuning process much more iterative instead of just generating random engineering problems.
Author
Irfan Uruchi
Part of my ongoing work on domain-specialized engineering language models and lightweight engineering reasoning systems.
- Downloads last month
- 11