Found air leakage, so fitting changed
Test Rig D1
Clamping problem
Found cable damaged, so new cable fitted,
PDI Assembly & PDI Packing CH01 Line-1
Z axis problem
Manually removed ball
Assembly station 3
Ball stuck
Manually basket movment d1
Durr Ultrasonic
Basket stuck
New grub screw fitted & tightened.
Test Rig F2
Drain motor problem
Machine restarted
Centre Lapping
Cycle not start
Portable chiller installed
EMAG-Rim
Chiller Temperature high
Found filter choked, so cleaned filter & refitted.
Test Rig G2
Pressure not developing
Changed bush accordingly
Deburring Machine
Need to change tool
Checked & restarted PC
Test Rig D1
Clamping problem
Allen key provided then ok.
Assembly stations of CH04
3mm allen key required
Checked & line filter cleaned
Test Rig F2
Pressure not developing
Checked door connection d1 properly then
Test Rig E2
Door not locked
Assembled all but still machine not working due to spindle slipping pulley assembly.
Klein 1
Need to assemble guide assembly & motor dresser
Torque gun to torque wmpalete but signal not on, due to low air pressure. SO pending
BVLINE PVM Assembly
Cycle not complete
Found key missing, so new key provided on spindle,
Klein 1
Spindle not rotate
Manually recovered
Durr Ultrasonic
Basket stuck
Torque gun changed but problem still same, so provided not air pressure line
BVLINE PVM Assembly
Cycle not soing ok
Select proper program
Micromatic Grinding
Job clamping problem
Brush changed
Deburring Machine
Brush to be changed
Tool repaired
Test Rig G1
Pressure releif tool broken
Filter cleaned
Test Rig E2
Tank pressure high
Gun height adjustment d1.
Assembly stations of CH04
Height of gun need to adjust
Found balls stuck, so manually recovered
Assembly stations of CH04
Balls feeder not working
After homing cycle started
Deburring Machine
Auto cycle not start
Switch tightened.
BVLINE PVG Assembly
Confirmation switch loose
Found station 2 sensor broken, so new sensor fitted.
Piston Coining
Station 2 cylinder problem
Checked & prerssure setting d1,
Piston Coining
Pressur problem
Found shaft, but properly tightened
Test Rig H1
Neutral problem
Filter cleaning d1
Test Rig E2
Tank line filter block
Machine restarted
Deburring Machine
Auto cycle not start
Filter changed
BVLINE Test Stand A(Dual stage)
Pressure not ok
Checked & new stud fitted
Test Rig D1
Stud broken
Hydraulic chuck pressure set
EMAG Rim
Checked feeder problem
Checked motor broke, relay not fitted properly. Relay installed
BVLINE Test Stand A (Single stage)
Cylinder rev. forward motor not operate
Checked & new PIN bolt fitted
Test Rig G1
Spline shaft pin broken
New tool trial taken found ok.
Assembly stations of CH05
New tool trail
Z axis bellow cover problem
Studer
Leakage
Found filter choked, so cleaned filter & refitted.
Test Rig E1 & E2
Tank pressure high
Fitted bolt properly then trial found ok.
Stahli S/F Grinding Machine 1
Slider locking belt missing
Top up oil d1.
PV Assembly & Leak Testing
Hydraulic oil low
Drain pipe choked, so cleaning d1 then trial found ok.
EMAG Rim
Conveyor oil leakage
Suction strainer cleaning d1. then trial found ok.
Cleantech
L.P problem
Checked need filter that working, so adjust then trial found ok.
Test Rig D1
Clamping problem
Fitted bolt properly tthen trial found ok.
Cleantech
LM block mounting bolt broken
Top up oil d1.
Cleantech
Lubrication oil low
Checked & m/c shutdown, then trial found ok.
Test Rig G1
Door lock problem
Drain oil.
BVLINE Assembly Station(Dual Stage)
Oil overflow
Adjust d1 of sensor, then trial found ok.
Studer 1 (450)
Pallte sensing present problem
Adjusted sensor properly then trial found ok.
Studer 1 (450)
Sensor routing worse
Checked & sensor fitted properly, then trial found ok.
Centre Lapping
Pallet stopper sensor problem
Changed drive but alarm came on expansion tool.
Kadia
Drive problem
then trial found ok.
EMAG Wheel
Lubrication unit faulty
Adjusted properly after cleaning, then trial found ok.
Assembly stations of CH02
Ball feeder not working
Adjusted sensor properly then trial found ok.
Assembly stations of CH06
Dust seal problem
Manually declamp then trial found ok.
Studer 1 (450)
Job stuck
Adjusted sensor properly then trial found ok.
PV Assembly & Leak Testing
Clamp signal missing
Adjusted sensor properly then trial found ok.
Piston Coining
Job present signal missing
Housing d1 then trial found ok.
Deburring Machine
Auto cycle not work
Checked relay, found working ok, then checked clutch assembly tightened & filetr cleaning d1 & also adjusted QP.
Test Rig G2
Neutral QP problem
Air leakage arrested
Centre Lapping
Air leakage
Clutch assembly retightened
Test Rig E1 & E2
Neutral problem
feeder properly alinment d1.
Assembly stations of CH02
Ball not feed
Found motor in head condition, so motor connection disconnected for sometime and then reconnected, then trial found ok.
EMAG Wheel
Spindle lubrication not reedy alarm
Mist collector cleaned and found 3 induction wire broken buit not replaced due to wire not found by store person.
Kapp Wheel
Mist collector leakage
Manually recovered
Test Rig B
Declamp problem
Manually recovered
Test Rig B
Declamp problem
Oil topup d1, then trial found ok.
BVLINE Test Stand A(Dual stage)
Oil level low
Filter cleaning d1
Test Rig F1 & F2
Neutral problem
Relay replaced, pallet filter cleaning d1, pallet pump faulty.
Test Rig G2
Neutral problem
Found that, tool present proxy disturbed, so setting d1. then trial found ok.
Piston Coining
Cycle start problem
Air leakage arrested then trial found ok.
PV Assembly & Leak Testing
Low pressure alarm
PLC restarted, then trial found ok.
PV Assembly & Leak Testing
Pressure problem
Sensor setting d1, then trial found ok.
Test Rig D1
Clamping problem
Magnetic separator slug cleaning d1, then trial found ok.
Studer Favorit
Magnetic separator problem
Door open relay stuck, removed the relay & reinserted. then trial found ok.
Cleantech
Unloading side door, open time aborted
Door open valve stuck, valve manually operated then trial found ok.
Cleantech
Middle side door open time aborted
Checked & found both stud broken, so replaced both, then trial found ok.
Test Rig D1
Stud broken
Properly alignment d1, then trial found ok.
Assembly station 2
Suction ball stucked
Found filter changing d1 then trial found ok.
Durr Ultrasonic
Vacuum pump filter leakage
Machine restarted, then trial found ok.
Studer
Cycle not start
Reed switch was disturbed, setting d1
Test Rig D1
Clamping problem
Fixture clamping cycle pin fall down, so connected it .
BVLINE PVM Assembly
Clamping problem
Didn't found any abnormalities, so machine restarted .
ELB Wheel
Operating panel hangout
For reducing the motor RPM changed gearbox, but same problem after changing new motor with gear box but same problem not solved. After as it is & space gearbox and motor with gear box handed to store person.
Test Rig D2
Plan work
Checked tank line filter cleaned
Test Rig F2
Tank pressure problem
Oil topup machine ok
Kadia 40
Lubrication oil low
Maintenance interval counter reset d1.
Durr Ultrasonic
Maintenace interval full alarm came
Checked & found problem came Emag wheel machine but night shift person's card interchanged by Emag Rim. Checked 30 minutes after same problem coming in Rim machine, so removed this card & fitted to original machine. trial taken found ok.
EMAG Rim & Wheel
Spindle lubrication faulty alarm came
Machine PLC restarted trial taken found ok.
Assembly stations of CH06
PLC disconnection problem
Belt properly tightened
Stahli S/F Grinding Machine 1
Beat station problem
Sensor cleaning d1, machine under observation
Centre Lapping
Return conveyor stopper problem
Found filter choked, so cleaned filter & refitted.
Test Rig E2
11.23 filter block problem
Tailstuck adjusted properly,
Studer
Tailstuck adjustment
So tool counter restarted.
Kadia 40
Cycle not start
Found clamping sensor not working properly. So adjusted sensor
Test Rig D1
Clamping problem
Checked & canged with new 1.
Test Rig D1
Stud Damaged
Set guard position accordingly,
Studer 1 (450)
Grinding wheel cover position need to set
Spanner provided.
PDI Line Cobot
10-11 Spanner required for setup
Master job has problem, so changed master & filter cleaned