64695439-3458-4d43-8e7b-a2ba75075cea
There must be safe and easily accessible, uninterrupted access routes to any chimneys, ventilation equipment and other building equipment and structural elements that are located on the roof of the building and that must be accessed regularly.
{'ID': '124_Finnish_SafetyOfUse'}
There must be safe and easily accessible, <e1>uninterrupted</e1> <e2>access routes</e2> to any chimneys, ventilation equipment and other building equipment and structural elements that are located on the roof of the building and that must be accessed regularly.
selection
c2c49207-78b3-42b0-8b61-ad506f5a80e2
In hard water areas, suitable measures should be taken to treat the feed water to water heaters and the hot water circuit of combination boilers to reduce lime-scale accumulation.
{'ID': '381_UK_DocL_V1_ConsrvationOfFuelAndPower'}
In <e1>hard water areas</e1>, suitable <e2>measures</e2> should be taken to treat the feed water to water heaters and the hot water circuit of combination boilers to reduce lime-scale accumulation.
necessity
726e23c9-02a3-4c56-98d0-8981b7ce877b
In the construction of a new building as well as in repair and alteration work corresponding to the construction of a new building, the premises to be fitted with a floor drain shall be: 1. showers and bathrooms as well as wash rooms in connection with saunas; 2. laundry room; 3. heat distribution room; 4. ventilation unit room; 5. toilet facility intended for public use; 6. technical utility room with a possibility to water damage; 7. car wash facility; 8. special facilities cleansed by water rinsing.
{'ID': '126_Finnish_Health-WaterAndSewerage'}
In the construction of a new building as well as in repair and alteration work corresponding to the construction of a new building, the premises to be <e1>fitted with a floor drain</e1> shall be: 1. showers and bathrooms as well as <e2>wash rooms</e2> in connection with saunas; 2. laundry room; 3. heat distribution room; 4. ventilation unit room; 5. toilet facility intended for public use; 6. technical utility room with a possibility to water damage; 7. car wash facility; 8. special facilities cleansed by water rinsing.
none
108b5709-f035-4697-ba25-56edd2ce60fc
Where permanent or removable seating is provided as part of the design, allowance should be made for disabled people to have a choice of seating location at spectator events.
{'ID': '126_UK_DocM_V2_AccessAndUseOfBuildings'}
Where permanent or <e1>removable</e1> seating is <e2>provided as part of the design</e2>, allowance should be made for disabled people to have a choice of seating location at spectator events.
none
a922fe4e-30c9-4fef-a442-27459b959914
Vertical service pipes shall be equipped with mechanical or structural leak detectors at each floor if the service pipes are not visible.
{'ID': '82_Finnish_Health-WaterAndSewerage'}
<e1>Vertical</e1> <e2>service pipes</e2> shall be equipped with mechanical or structural leak detectors at each floor if the service pipes are not visible.
selection
a387fcb8-ead2-4094-9be9-72d783468b33
If the area of windows, roof windows, rooflights and doors exceeds 25 of the total floor area of the dwelling, compensating measures should be taken to improve the energy efficiency of the dwelling.
{'ID': '422_UK_DocL_V1_ConsrvationOfFuelAndPower'}
If the <e1>area</e1> of windows, roof windows, rooflights and doors exceeds <e2>25</e2> of the total floor area of the dwelling, compensating measures should be taken to improve the energy efficiency of the dwelling.
greater
56517433-cf40-4b88-a9d4-18e61e0e9993
In addition, on both sides of the toilet seat there shall be a free space of at least 800 millimetres.
{'ID': '55_Finnish_Accessibility'}
In addition, on <e1>both sides</e1> of the toilet seat there shall be a <e2>free space</e2> of at least 800 millimetres.
necessity
8e5e9560-4b22-4fe0-ad86-e52b82ffe4d2
When calculating the energy consumption of a buildings cooling system, the energy consumption of cooling energy production and the electrical energy consumption of auxiliary units shall be taken into account where the use of the systems is required for indoor temperature control.
{'ID': '111_Finnish_EnergyEfficiency'}
When calculating the energy consumption of a buildings cooling system, the <e1>energy consumption</e1> of <e2>cooling energy production</e2> and the electrical energy consumption of auxiliary units shall be taken into account where the use of the systems is required for indoor temperature control.
part-of
4abb3268-3ba6-47e8-a8b7-4676dbaa9a16
For buildings other than dwellings and for common access areas in buildings that contain flats, Provide all means of escape routes with a minimum clear headroom of 2m, except in doorways.
{'ID': '28_UK_DocK_ProtectionFromFalling'}
For buildings other than dwellings and for common access areas in buildings that contain flats, Provide all means of escape routes with a minimum clear <e1>headroom</e1> of <e2>2m</e2>, except in doorways.
equal
703e5c71-bd54-4267-acf4-fa7db1e70d49
Any sound system in an auditorium, a restaurant, a conference facility, a facility for festive occasions, a teaching facility or other similar assembly facility or a public service facility shall have an induction loop or a similar sound transmission system.
{'ID': '67_Finnish_Accessibility'}
Any sound system in an auditorium, a restaurant, a conference facility, a <e1>facility for festive occasions</e1>, a <e2>teaching facility</e2> or other similar assembly facility or a public service facility shall have an induction loop or a similar sound transmission system.
none
7c8f6c05-769d-46a8-9dc6-84b509bf8d9c
The fire compartmenting requirement for the balcony slab of a glazed balcony of a building exceeding two storeys is EI 30; however, minor sealing parts and penetrations may be class E 15.
{'ID': '134_Finnish_FireSafety'}
The <e1>fire compartmenting requirement</e1> for the balcony slab of a glazed balcony of a building exceeding two storeys is EI 30; however, minor sealing parts and penetrations may be <e2>class</e2> E 15.
none
5ca184fa-e100-4f97-957d-e37ae944786f
The cost of installing electric vehicle charge points and cable routes is not more than 7% of the total capital cost of the major renovation.
{'ID': '51_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
The cost of <e1>installing electric vehicle charge points and cable routes</e1> is not more than 7% of the <e2>total capital cost</e2> of the major renovation.
none
f6e7c818-f661-400b-8272-8062c5a7de68
Where a lift is provided, it should be suitable for a wheelchair user.
{'ID': '22_UK_DocM_V1_AccessAndUseOfBuildings'}
Where a <e1>lift</e1> is provided, it should be <e2>suitable for a wheelchair use</e2>r.
necessity
aca1acce-65c1-4677-a979-ce2920457a55
The surface of stairs the must not be slippery.
{'ID': '14_Finnish_SafetyOfUse'}
The <e1>surface</e1> of <e2>stairs</e2> the must not be slippery.
part-of
dae0db09-fd4b-4f2c-99c0-cd742b19d17a
A glass structure or other light-permeable structure, along with its mountings, must withstand the load to which it is normally subject, unless the structure is protected by a fixed collision barrier.
{'ID': '68_Finnish_SafetyOfUse'}
A glass structure or other light-permeable structure, along with <e1>its</e1> <e2>mountings</e2>, must withstand the load to which it is normally subject, unless the structure is protected by a fixed collision barrier.
part-of
d43e4877-601c-43eb-9d33-96945754374b
Good acoustic design should be employed to achieve an acoustic environment that is neither too reverberant nor too absorbent so that announcements and conversations can be heard clearly.
{'ID': '99_UK_DocM_V2_AccessAndUseOfBuildings'}
Good acoustic design should be employed to achieve an <e1>acoustic environment</e1> that is neither too reverberant nor too absorbent <e2>so that announcements and conversations can be heard clearly</e2>.
none
77be05f2-cd8c-4d35-85e4-6637b999d8e7
The value of the consequential improvement works should not be less than 10 of the value of the principal works.
{'ID': '452_UK_DocM_V2_AccessAndUseOfBuildings'}
The <e1>value</e1> of the consequential <e2>improvement works</e2> should not be less than 10 of the value of the principal works.
part-of
a9c88566-e4e5-4cba-8165-9916820d9cc5
Doors, gates and boom barriers must operate safely and in such a way that they do not cause a danger of an accident.
{'ID': '75_Finnish_SafetyOfUse'}
Doors, gates and <e1>boom barriers</e1> must <e2>operate safely</e2> and in such a way that they do not cause a danger of an accident.
necessity
fc54cd23-e216-4f59-b1b6-35ec47a83a4a
Test data must be from a minimum of five in-situ measurements of the same module types and link details as used in the actual building.
{'ID': '351_UK_DocM_V2_AccessAndUseOfBuildings'}
<e1>Test data</e1> must be <e2>from a minimum of five in-situ measurements of the same module types</e2> and link details as used in the actual building.
necessity
1c511111-ab71-4b68-9421-f588bc4b9180
People with visual impairment should be in no doubt as to the location of glass doors, especially when they are within a glazed screen.
{'ID': '76_UK_DocM_V2_AccessAndUseOfBuildings'}
<e1>People</e1> <e2>with visual impairment</e2> should be in no doubt as to the location of glass doors, especially when they are within a glazed screen.
necessity
5925ca4d-801c-42e4-b581-a176dea2519f
If thermal energy is supplied from a district heat network, a CO2 emission factor and primary energy factor for the heat delivered to the dwelling by the district heat network should be calculated.
{'ID': '76_UK_DocL_V1_ConsrvationOfFuelAndPower'}
If thermal energy is supplied from a district heat network, a CO2 emission factor and <e1>primary energy factor</e1> for the heat delivered to the dwelling by the district heat network should be <e2>calculated</e2>.
necessity
5211dbd1-d12a-4371-ad62-1dc5616cd2f5
The heat pump along with its accompanying pipework should be flushed and purged as a separate system while isolated from the ground array system.
{'ID': '387_UK_DocL_V1_ConsrvationOfFuelAndPower'}
The <e1>heat pump</e1> along with its accompanying <e2>pipework</e2> should be flushed and purged as a separate system while isolated from the ground array system.
part-of
e7be7432-5505-47ad-b586-2a2e3f5a1a37
If the index terminal has to be set to a significantly closed position to achieve the required air flow rate, then the fan speed should be reduced and the terminals rebalanced.
{'ID': '203_UK_DocF_V1_Ventilation'}
If the index terminal has to be <e1>set to a significantly closed position to achieve the required air flow rate</e1>, then the fan <e2>speed</e2> should be reduced and the terminals rebalanced.
none
81f14fc1-af5d-45e8-8725-94d2510e4701
A dwelling that is intended for service housing or supported housing of a person with mobility and functional impairment shall, irrespective of the number of storeys in the building, have a turning space with a diameter of at least 1,500 millimetres in the hallway and kitchen.
{'ID': '29_Finnish_Accessibility'}
A dwelling that is intended for service housing or supported housing of a person with mobility and functional impairment shall, irrespective of the number of storeys in the building, have a turning space with a <e1>diameter</e1> of at least <e2>1,500 millimetres</e2> in the hallway and kitchen.
greater-equal
29232335-402c-4ed9-af74-fd093ac22e28
The natural or mechanical ventilation system of a building shall be strong and its air-tightness shall be at least class B.
{'ID': '95_Finnish_Health-IndoorClimateAndVentilation'}
The natural or <e1>mechanical</e1> <e2>ventilation system</e2> of a building shall be strong and its air-tightness shall be at least class B.
selection
16f6f10e-f32f-48b2-85f9-123cdb5448ee
Any unavoidable gaps between boards should be infilled using compressible tape (e.g. for boards within roof rafters) or low expansion foam (e.g. for boards within wall cavities).
{'ID': '147_UK_DocL_V1_ConsrvationOfFuelAndPower'}
Any unavoidable gaps between boards should be <e1>infilled</e1> using <e2>compressible tape</e2> (e.g. for boards within roof rafters) or low expansion foam (e.g. for boards within wall cavities).
selection
0df5892a-e396-424e-90f1-74f6ccfb9e1a
A certain proportion of the changing rooms, washing facilities, saunas and swimming pools in a non-residential building shall be suitable for a person with mobility and functional impairment.
{'ID': '61_Finnish_Accessibility'}
A certain proportion of the changing rooms, <e1>washing facilities</e1>, saunas and swimming pools in a <e2>non-residential building</e2> shall be suitable for a person with mobility and functional impairment.
part-of
6ec243f2-9294-4b7c-89a4-1c46e4a69cc9
If site constraints necessitate an approach of 1:20 or steeper, an approach incorporating ramped access should be provided.
{'ID': '49_UK_DocM_V2_AccessAndUseOfBuildings'}
If site constraints necessitate an <e1>approach</e1> of <e2>1:20</e2> or steeper, an approach incorporating ramped access should be provided.
greater-equal
f27c9fb4-dc28-494c-a277-a51360cdfdb8
A handrail and its ending must be shaped safely and must continue past the start and end points of the structure.
{'ID': '57_Finnish_SafetyOfUse'}
A handrail and <e1>its</e1> <e2>ending</e2> must be shaped safely and must continue past the start and end points of the structure.
part-of
9dd2a0f1-0ff9-4416-8abd-1e6589980ff4
If the cross-sectional area of a mechanical ventilation systems air duct is designed to be greater than 0.06 m2, the outdoor air and exhaust air ducts shall be fitted with shutoff dampers that close automatically when the system shuts down.
{'ID': '100_Finnish_Health-IndoorClimateAndVentilation'}
If the cross-sectional area of a mechanical <e1>ventilation systems</e1> <e2>air duct</e2> is designed to be greater than 0.06 m2, the outdoor air and exhaust air ducts shall be fitted with shutoff dampers that close automatically when the system shuts down.
part-of
259c1614-77ef-4ae4-a401-83caa603e374
The main doors for entering a dwelling (usually the front doorset) should be fitted with a multipoint locking system that meets the requirements of: PAS 3621 (key locking on both sides), or PAS 8621 (non-key locking on the internal face), or PAS 10621 (non-key locking on the internal face, but with an external locking override facility).
{'ID': '35_UK_DocQ_Security_Dwellings'}
The <e1>main doors</e1> <e2>for entering a dwelling</e2> (usually the front doorset) should be fitted with a multipoint locking system that meets the requirements of: PAS 3621 (key locking on both sides), or PAS 8621 (non-key locking on the internal face), or PAS 10621 (non-key locking on the internal face, but with an external locking override facility).
selection
66249fda-33bf-4d93-8bf9-53fb82ad0e95
The driveway and parking area at a plot or building site must be separated from pedestrian, play and recreation areas.
{'ID': '87_Finnish_SafetyOfUse'}
The driveway and <e1>parking area</e1> at a plot or <e2>building site</e2> must be separated from pedestrian, play and recreation areas.
part-of
103f99ad-884b-4bae-9f22-ccb1c5bc3d26
In an open garage of no more than five storeys, the maximum area may be used as the surface area of the storeys, even though the driveways between the various storeys are combined.
{'ID': '110_Finnish_FireSafety'}
In an open garage of no more than five <e1>storeys</e1>, the maximum area may be used as the surface area of the storeys, even though the driveways between the various storeys are <e2>combined</e2>.
none
6e5e61dd-039d-4079-9c3f-f52fc12efefb
For continuing horizontal structures the loaded area shall be calculated span by span.
{'ID': '12_Finnish_StabilityOfStructures'}
For continuing horizontal structures the <e1>loaded area</e1> shall be <e2>calculated span by span</e2>.
necessity
83ff563b-077a-4849-b526-382fbb012647
The breaking of a glass structure or other light-permeable structure of a building must not cause a danger of falling or a danger of injury from fragments falling onto persons below.
{'ID': '67_Finnish_SafetyOfUse'}
The breaking of a glass structure or other <e1>light-permeable structure</e1> of a <e2>building</e2> must not cause a danger of falling or a danger of injury from fragments falling onto persons below.
part-of
4c83069b-8c22-43ad-92a0-354ecd0e40a1
Sufficient information should be provided to ensure that people can operate, maintain or alter an electrical installation with reasonable safety.
{'ID': '7_UK_DocP_ElectricalSafety'}
Sufficient <e1>information</e1> should be <e2>provided to ensure that people can operate, maintain or alter an electrical installation with reasonable safety</e2>.
necessity
06c2e0f7-69c8-47ec-bf31-9902ae9df7cf
Provision shall be made for any windows, skylights, or any transparent or translucent walls, ceilings or roofs to be safely accessible for cleaning.
{'ID': '109_UK_DocK_ProtectionFromFalling'}
Provision shall be made for any windows, <e1>skylights</e1>, or any transparent or translucent walls, ceilings or roofs to <e2>be safely accessible for cleaning</e2>.
necessity
710ef992-e187-4b1a-894b-e0e222f54359
NOTE: For grid-supplied electricity, a CO2 emission factor of 0.136kgCO2/kWh and primary energy factor of 1.501kWhPE/kWh should be used.
{'ID': '199_UK_DocM_V2_AccessAndUseOfBuildings'}
NOTE: For <e1>grid-supplied</e1> <e2>electricity</e2>, a CO2 emission factor of 0.136kgCO2/kWh and primary energy factor of 1.501kWhPE/kWh should be used.
selection
7f72632a-dc0a-4318-afd7-7090b42350fc
Mechanical supply terminals should be located and directed to avoid draughts.
{'ID': '106_UK_DocF_V1_Ventilation'}
Mechanical <e1>supply terminals</e1> should be located and <e2>directed</e2> to avoid draughts.
necessity
4e119abd-0cf7-4c60-9c7b-1083f9b46280
NOTE: If an exposed facade is close to an area of sustained and loud noise (e.g. a main road), then a noise attenuating background ventilator should be fitted.
{'ID': '85_UK_DocF_V2_Ventilation'}
NOTE: If an <e1>exposed</e1> facade is close to an area of sustained and loud noise (e.g. a main road), then a noise attenuating background ventilator should be <e2>fitted</e2>.
none
2cf150af-bede-4bb6-aa2e-b9f42a109761
The warning should be placed sufficiently in advance of the hazard to allow time to stop and not be so narrow that it might be missed in a single stride.
{'ID': '53_UK_DocM_V2_AccessAndUseOfBuildings'}
The <e1>warning</e1> should be placed sufficiently in advance of the hazard to allow time to stop and <e2>not be so narrow that it might be missed in a single stride</e2>.
necessity
0a53e4af-84a7-46aa-b28a-cb1d873c8cae
The type and quality of public address, hearing enhancement and telephone systems should be chosen carefully to ensure intelligibility.
{'ID': '151_UK_DocM_V2_AccessAndUseOfBuildings'}
The <e1>type and quality</e1> of <e2>public address</e2>, hearing enhancement and telephone systems should be chosen carefully to ensure intelligibility.
selection
35af73f1-53c7-4377-9da0-acf99eef4d8e
WC compartment doors, and doors to wheelchair-accessible unisex toilets, changing rooms or shower rooms have an emergency release mechanism so that they are capable of being opened outwards, from the outside , in case of emergency.
{'ID': '159_UK_DocM_V2_AccessAndUseOfBuildings'}
WC compartment doors, and doors to wheelchair-accessible <e1>unisex</e1> <e2>toilets</e2>, changing rooms or shower rooms have an emergency release mechanism so that they are capable of being opened outwards, from the outside , in case of emergency.
selection
525aa713-65e1-4368-a6f4-38f628be7fed
in clothes shops, the dimensions and fittings recommended for an individual changing cubicle in a sports building should be provided.
{'ID': '177_UK_DocM_V2_AccessAndUseOfBuildings'}
in clothes shops, the dimensions and <e1>fittings</e1> <e2>recommended for an individual changing cubicle</e2> in a sports building should be provided.
selection
0cfe8c0e-45e4-4c4c-bf9b-906e26e28c75
There should be sufficient space for people to approach the building, pass others who are travelling in the opposite direction and carry out all necessary manoeuvres.
{'ID': '43_UK_DocM_V2_AccessAndUseOfBuildings'}
There should be <e1>sufficient</e1> space for people to approach the building, <e2>pass others who are travelling in the opposite direction</e2> and carry out all necessary manoeuvres.
none
656aa2fa-18cb-41ee-ae28-28deb3dffcc3
The water temperature of the water in the hot water system shall be at least 55 degrees Celsius and available from the hot water plumbing fixture within 20 seconds.
{'ID': '61_Finnish_Health-WaterAndSewerage'}
The water temperature of the <e1>water</e1> in the <e2>hot water system</e2> shall be at least 55 degrees Celsius and available from the hot water plumbing fixture within 20 seconds.
part-of
7d7d55f1-b28d-4ce8-aec6-dd4dc0786ce8
For sizes of cylinder not listed, the heat loss from the cylinder should not exceed (16.66 8.33 V0.4)/(1000 24), where V is the volume in litres.
{'ID': '208_UK_DocL_V1_ConsrvationOfFuelAndPower'}
For sizes of <e1>cylinder</e1> not listed, the heat loss <e2>from the cylinder</e2> should not exceed (16.66 8.33 V0.4)/(1000 24), where V is the volume in litres.
none
a922fe4e-30c9-4fef-a442-27459b959914
Vertical service pipes shall be equipped with mechanical or structural leak detectors at each floor if the service pipes are not visible.
{'ID': '82_Finnish_Health-WaterAndSewerage'}
Vertical <e1>service pipes</e1> shall be equipped with mechanical or structural leak detectors at each floor if the service pipes are <e2>not visible</e2>.
selection
7f72632a-dc0a-4318-afd7-7090b42350fc
Mechanical supply terminals should be located and directed to avoid draughts.
{'ID': '106_UK_DocF_V1_Ventilation'}
Mechanical <e1>supply terminals</e1> should be <e2>located</e2> and directed to avoid draughts.
necessity
c47598f9-df79-4d77-aba9-8f380342372f
extract air of category 4 shall be conducted to the outdoors through individual extract air ducts.
{'ID': '88_Finnish_Health-IndoorClimateAndVentilation'}
extract air of <e1>category</e1> <e2>4</e2> shall be conducted to the outdoors through individual extract air ducts.
equal
8e9ef8dc-18bd-4877-98cd-556aa4adee8f
Reasonable provision shall be made for the conservation of fuel and power in buildings by: (a) limiting heat gains and losses (i) through thermal elements and other parts of the building fabric; and (ii) from pipes, ducts and vessels used for space heating, space cooling and hot water services; (b) providing fixed building services which (i) are energy efficient to a reasonable standard; (ii) have effective controls; and (iii) are commissioned by testing and adjusting as necessary to ensure they use no more fuel and power than is reasonable in the circumstances.
{'ID': '431_UK_DocM_V2_AccessAndUseOfBuildings'}
Reasonable provision shall be made for the conservation of fuel and power in <e1>buildings</e1> by: (a) limiting heat gains and losses (i) through thermal elements and other parts of the building fabric; and (ii) from pipes, ducts and vessels used for space heating, space cooling and hot water services; (b) <e2>providing fixed building services</e2> which (i) are energy efficient to a reasonable standard; (ii) have effective controls; and (iii) are commissioned by testing and adjusting as necessary to ensure they use no more fuel and power than is reasonable in the circumstances.
none
09b2a395-5293-4b7d-82d4-5312482d59e9
Door entry controls, where provided, are mounted 900-1000mm above finished ground level, and at least 300mm away from any projecting corner.
{'ID': '46_UK_DocM_V1_AccessAndUseOfBuildings'}
Door entry controls, where provided, are mounted <e1>900-1000mm</e1> above finished ground level, and at least 300mm away from any <e2>projecting corner</e2>.
none
b51c7a9f-2080-4e60-940f-e59af0cc97ce
The buildings enclosure together with its construction layers and joints must form a whole, preventing the transfer of water across the surface of the enclosure into the construction by wind, slanting rain and wind pressure.
{'ID': '34_Finnish_Health-Humidity'}
The buildings <e1>enclosure</e1> together with its <e2>construction layers</e2> and joints must form a whole, preventing the transfer of water across the surface of the enclosure into the construction by wind, slanting rain and wind pressure.
part-of
77be05f2-cd8c-4d35-85e4-6637b999d8e7
The value of the consequential improvement works should not be less than 10 of the value of the principal works.
{'ID': '452_UK_DocM_V2_AccessAndUseOfBuildings'}
The <e1>value</e1> of the consequential improvement works should not be less than <e2>10</e2> of the value of the principal works.
greater-equal
ccc405a0-c6d6-4ace-ad70-e0cfe07cd1e3
Stairs, ladders and ramps shall be so designed, constructed and installed as to be safe for people moving between different levels in or about the building.
{'ID': '14_UK_DocK_ProtectionFromFalling'}
<e1>Stairs</e1>, ladders and ramps shall be so <e2>designed, constructed and installed as to be safe for people moving between different levels in or about the building</e2>.
necessity
6e5e61dd-039d-4079-9c3f-f52fc12efefb
For continuing horizontal structures the loaded area shall be calculated span by span.
{'ID': '12_Finnish_StabilityOfStructures'}
For <e1>continuing</e1> horizontal structures the loaded area shall be <e2>calculated span by span</e2>.
none
9952f64d-e0df-4b03-84af-150782f81387
For mobility-impaired people, a going of at least 300mm is preferred.
{'ID': '124_UK_DocM_V2_AccessAndUseOfBuildings'}
For <e1>mobility-impaired</e1> people, a going of at least <e2>300mm</e2> is preferred.
none
4e1bda84-398f-4bae-a335-2c7f24501b09
The water heater is situated centrally with a distribution system to supply water to the drawoff points and has a capacity greater than 300 litres.
{'ID': '456_UK_DocM_V2_AccessAndUseOfBuildings'}
The <e1>water heater</e1> is situated centrally with a distribution system to supply water to the drawoff points and has a <e2>capacity</e2> greater than 300 litres.
part-of
239bd568-c5f2-4ab5-955c-f2d8d86b7b7f
Where closing devices are needed for fire control, electrically powered hold-open devices or swing-free closing devices should be used as appropriate.
{'ID': '90_UK_DocM_V2_AccessAndUseOfBuildings'}
Where closing devices are needed for fire control, electrically powered <e1>hold-open devices</e1> or swing-free closing devices should be <e2>used as appropriate</e2>.
necessity
81f14fc1-af5d-45e8-8725-94d2510e4701
A dwelling that is intended for service housing or supported housing of a person with mobility and functional impairment shall, irrespective of the number of storeys in the building, have a turning space with a diameter of at least 1,500 millimetres in the hallway and kitchen.
{'ID': '29_Finnish_Accessibility'}
A dwelling that is intended for service housing or supported housing of a person with mobility and functional impairment shall, irrespective of the number of storeys in the building, have a <e1>turning space</e1> with a <e2>diameter</e2> of at least 1,500 millimetres in the hallway and kitchen.
part-of
642e2c46-45a8-440f-af0b-1b53f41d8d8f
Taps and WC cubicle doors should be operable by people with limited strength or manual dexterity and doors to cubicles should be capable of being opened if a person has collapsed against them while inside the cubicle.
{'ID': '156_UK_DocM_V2_AccessAndUseOfBuildings'}
<e1>Taps</e1> and WC cubicle doors should be <e2>operable by people with limited strength or manual dexterity</e2> and doors to cubicles should be capable of being opened if a person has collapsed against them while inside the cubicle.
necessity
ffc11c58-ff7e-45f4-a5c7-da59404e5659
Reasonable provision shall be made in the design and installation of electrical installations in order to protect persons operating, maintaining or altering the installations from fire or injury.
{'ID': '1_UK_DocP_ElectricalSafety'}
Reasonable provision shall be made in the design and <e1>installation</e1> of electrical installations in order to <e2>protect persons operating, maintaining or altering the installations from fire or injury</e2>.
necessity
aaca648c-5f60-4300-a30f-887da252ebd0
The use of visually and acoustically reflective wall surfaces should be minimised within the lifting platform to prevent discomfort for people with visual and hearing impairment.
{'ID': '116_UK_DocM_V2_AccessAndUseOfBuildings'}
The use of <e1>visually</e1> and acoustically reflective <e2>wall surfaces</e2> should be minimised within the lifting platform to prevent discomfort for people with visual and hearing impairment.
selection
b5aa20f2-571e-48d8-9943-4102c9f9bd1a
In exit passageways and fire-compartmented elevator shafts, means must be arranged for both smoke extraction and flow of replacement air.
{'ID': '250_Finnish_FireSafety'}
In exit passageways and fire-compartmented elevator shafts, <e1>means</e1> must be arranged for both smoke extraction and <e2>flow of replacement air</e2>.
selection
1cf2f287-457b-4f89-8c43-135ffda5029a
The provision made must be sufficient to (a) meet the needs of occupants with differing needs, including some older or disabled people; and (b) to allow adaptation of the dwelling to meet the changing needs of occupants over time.
{'ID': '36_UK_DocM_V1_AccessAndUseOfBuildings'}
The <e1>provision</e1> made must be sufficient to (a) <e2>meet the needs of occupants with differing needs, including some older or disabled people</e2>; and (b) to allow adaptation of the dwelling to meet the changing needs of occupants over time.
necessity
fc129e2c-abfa-48be-9fd6-e85f077ae67b
A space alongside the leading edge of a door should be provided to enable a wheelchair user to reach and grip the door handle, then open the door without releasing hold on the handle and without the footrest colliding with the return wall.
{'ID': '70_UK_DocM_V2_AccessAndUseOfBuildings'}
A <e1>space</e1> alongside the leading edge of a <e2>door</e2> should be provided to enable a wheelchair user to reach and grip the door handle, then open the door without releasing hold on the handle and without the footrest colliding with the return wall.
none
fac44f87-4eb9-4f56-998c-74efa9512309
If air barriers or vapour barriers have been used in the structure, the seams, edges and penetrations must be tight.
{'ID': '106_Finnish_Health-Humidity'}
If <e1>air barriers</e1> or vapour barriers have been used in the structure, the seams, edges and <e2>penetrations</e2> must be tight.
none
1913381b-a2cc-496e-9168-82ccf2a01d50
In connection with repair and alteration work, the heat emitters connected to the domestic hot water ring duct may be replaced so that the heat emission capacity of the heat emitters to be installed does not exceed 200 Watts per room.
{'ID': '67_Finnish_Health-WaterAndSewerage'}
In connection with repair and alteration work, the heat emitters connected to the domestic hot water ring duct may be replaced so that the heat emission capacity of the <e1>heat emitters</e1> <e2>to be installed</e2> does not exceed 200 Watts per room.
selection
db734798-9e42-4fe1-900c-77d4e6131809
The main doors for entering a dwelling (usually the front door) should have a door viewer unless other means exist to see callers, such as clear glass within the door or a window next to the doorset.
{'ID': '11_UK_DocQ_Security_Dwellings'}
The <e1>main doors</e1> for entering a dwelling (usually the <e2>front door</e2>) should have a door viewer unless other means exist to see callers, such as clear glass within the door or a window next to the doorset.
selection
354c849e-8e02-47ec-992c-e5431a62cb3f
Ventilation systems that provide supply and extract ventilation should be fitted with a heat recovery system where technically feasible.
{'ID': '309_UK_DocM_V2_AccessAndUseOfBuildings'}
<e1>Ventilation systems</e1> that provide supply and extract ventilation should be <e2>fitted with a heat recovery system where technically feasible</e2>.
necessity
d9b8f957-49e3-45d0-83ca-c0419a50361a
In a mechanical system, there shall be a clearly labelled stop switch, which shall be located in an easily accessible place.
{'ID': '48_Finnish_Health-IndoorClimateAndVentilation'}
In a mechanical system, there shall be a <e1>clearly labelled</e1> <e2>stop switch</e2>, which shall be located in an easily accessible place.
selection
825053cb-af5d-43a9-b59b-e2a5ae78ea73
The total number of associated parking spaces which have access to either: a. cable routes; b. an electric vehicle charge point should be the greater of the following: a. the number of dwellings in the residential building; b. the number of associated parking spaces.
{'ID': '59_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
The <e1>total number</e1> of associated <e2>parking spaces</e2> which have access to either: a. cable routes; b. an electric vehicle charge point should be the greater of the following: a. the number of dwellings in the residential building; b. the number of associated parking spaces.
part-of
d8a06af7-3a6b-4d68-8bba-342aac6d3ac0
Water pipes and sewers installed in the ground shall be identifiable and they shall be located separate from one another.
{'ID': '146_Finnish_Health-WaterAndSewerage'}
Water pipes and sewers <e1>installed in the ground</e1> shall be <e2>identifiable</e2> and they shall be located separate from one another.
none
4f2b56cb-9852-4406-bbea-31f426fb4910
replacing a heating system including the heating appliance, pipework and heat emitters), the energy performance of the whole system should be assessed, and the results documented and handed over to the building owner with the manufacturers supporting literature.
{'ID': '397_UK_DocM_V2_AccessAndUseOfBuildings'}
<e1>replacing</e1> a heating system including the <e2>heating appliance</e2>, pipework and heat emitters), the energy performance of the whole system should be assessed, and the results documented and handed over to the building owner with the manufacturers supporting literature.
none
5869233a-4fc0-48bf-9007-2b0c9a169fef
A building shall, if its size, number of storeys or an intended purpose of a premises within the building so requires, be divided into fire compartments in order to restrict the spread of fire and smoke, to provide safe evacuation and to facilitate rescue and extinguishing measures.
{'ID': '100_Finnish_FireSafety'}
A building shall, if its size, <e1>number of storeys</e1> or an intended purpose of a premises within the building so <e2>requires</e2>, be divided into fire compartments in order to restrict the spread of fire and smoke, to provide safe evacuation and to facilitate rescue and extinguishing measures.
selection
c06bb553-d8f1-47f5-ab33-cfdebb6bca52
When a building undergoes a major renovation, the technical, environmental and economic feasibility of installing high-efficiency alternative systems should be considered.
{'ID': '117_UK_DocM_V2_AccessAndUseOfBuildings'}
When a <e1>building</e1> undergoes a major renovation, the technical, environmental and economic <e2>feasibility of installing high-efficiency alternative systems</e2> should be considered.
necessity
74b9ee2c-0192-442d-b5a1-a2974d456429
The dwelling is wheelchair adaptable such that key parts of the accommodation, including sanitary facilities and kitchens, could be easily altered to meet the needs of a wheelchair user or, where required by a local planning authority, the dwelling is wheelchair accessible.
{'ID': '67_UK_DocM_V1_AccessAndUseOfBuildings'}
The dwelling is wheelchair adaptable such that key parts of the accommodation, including sanitary facilities and kitchens, could be easily altered to meet the needs of a wheelchair user or, <e1>where required by a local planning authority</e1>, the <e2>dwelling is wheelchair accessible</e2>.
necessity
8207751f-13b8-4fe3-9bfe-4423093d4905
A building with dwellings or accommodation or patient rooms shall be designed and implemented so that the reverberation time of the staircase and exit route is no more than 1.3 seconds.
{'ID': '26_Finnish_AcousticEnvironment'}
A <e1>building</e1> with dwellings or accommodation or patient rooms shall be <e2>designed and implemented</e2> so that the reverberation time of the staircase and exit route is no more than 1.3 seconds.
necessity
b5aa20f2-571e-48d8-9943-4102c9f9bd1a
In exit passageways and fire-compartmented elevator shafts, means must be arranged for both smoke extraction and flow of replacement air.
{'ID': '250_Finnish_FireSafety'}
In <e1>exit passageways</e1> and fire-compartmented elevator shafts, <e2>means</e2> must be arranged for both smoke extraction and flow of replacement air.
necessity
1603fe12-9df6-4ab9-acbe-44895cccb7ed
Any looped cords must be fitted with child safety devices.
{'ID': '87_UK_DocO_Overheating'}
Any <e1>looped</e1> <e2>cords</e2> must be fitted with child safety devices.
selection
d0ef750b-078c-4e63-a57f-298674c06a5e
Moisture-resistant insulation should be fitted below damp-proof course level and extend to the foundation block/structure.
{'ID': '136_UK_DocL_V1_ConsrvationOfFuelAndPower'}
Moisture-resistant <e1>insulation</e1> should be fitted below damp-proof course level and <e2>extend to the foundation block/structure</e2>.
necessity
50e89a86-e2be-439d-b230-79274cd7199b
Modular and portable buildings with a planned service life of more than two years at a single location should be shown to comply with the energy efficiency requirements.
{'ID': '81_UK_DocM_V2_AccessAndUseOfBuildings'}
Modular and <e1>portable</e1> buildings with a planned service life of more than <e2>two years</e2> at a single location should be shown to comply with the energy efficiency requirements.
none
f009a781-0ced-408d-b3d1-6ae7a848012e
The landings in the indoor and outdoor areas of a building must be safe, sufficiently spacious and suitable for their purpose.
{'ID': '31_Finnish_SafetyOfUse'}
The <e1>landings</e1> in the indoor and outdoor areas of a building must be safe, <e2>sufficiently spacious</e2> and suitable for their purpose.
necessity
d3fc8c9b-c23a-4188-8723-369caa90453c
The reference value for a building's total combined window area is 15 of the sum total of the floor plate areas of the buildings storeys that are fully or in part above the ground but, however, at most 50 of the building's facade area.
{'ID': '124_Finnish_EnergyEfficiency'}
The reference value for a building's total combined window area is 15 of the sum total of the floor plate areas of the buildings storeys that are fully or in part above the ground but, however, at most 50 of the <e1>building's</e1> <e2>facade area</e2>.
part-of
f02161e2-1942-4ddf-9627-e3343df63909
System controls should be wired so that when there is no demand for space heating, the heating appliance and pump are switched off.
{'ID': '214_UK_DocM_V2_AccessAndUseOfBuildings'}
<e1>System controls</e1> should be <e2>wired</e2> so that when there is no demand for space heating, the heating appliance and pump are switched off.
necessity
0cafda73-ee3a-4a99-a224-2d142de63618
Where a wet heating system is either: a. newly installed b. fully replaced in an existing building, including the heating appliance, emitters and associated pipework all parts of the system including pipework and emitters should be sized to allow the space heating system to operate effectively and in a manner that meets the heating needs of the dwelling, at a maximum flow temperature of 55C or lower.
{'ID': '238_UK_DocL_V1_ConsrvationOfFuelAndPower'}
Where a wet <e1>heating system</e1> is either: a. newly installed b. <e2>fully replaced</e2> in an existing building, including the heating appliance, emitters and associated pipework all parts of the system including pipework and emitters should be sized to allow the space heating system to operate effectively and in a manner that meets the heating needs of the dwelling, at a maximum flow temperature of 55C or lower.
selection
0f67dad7-6df9-444b-8e72-f447668e3fde
Where sanitary facilities are wheelchair accessible, WC pans should be a minimum of 400mm high.
{'ID': '104_UK_DocM_V1_AccessAndUseOfBuildings'}
Where sanitary facilities are wheelchair accessible, WC pans should be a minimum of <e1>400mm</e1> <e2>high</e2>.
greater-equal
8fec1c4a-527e-49b6-9267-89ff700a9291
Where membranes are penetrated, careful detailing should be used to achieve a robust and durable seal at these penetrations.
{'ID': '182_UK_DocL_V1_ConsrvationOfFuelAndPower'}
Where <e1>membranes</e1> are <e2>penetrated</e2>, careful detailing should be used to achieve a robust and durable seal at these penetrations.
selection
77f993c6-dff1-4f9a-8f66-73221d3cbaff
If the dwelling only has one habitable room, a minimum ventilation rate of 13l/s should be used.
{'ID': '43_UK_DocF_V1_Ventilation'}
If the <e1>dwelling</e1> only has one <e2>habitable room</e2>, a minimum ventilation rate of 13l/s should be used.
part-of
9fee4426-8d7f-40f9-bc6f-562a5d3fd9b4
For roofs insulated at ceiling level, the long-term protection of the insulation layer should be considered: boarded areas should be provided above the insulation to give access for maintenance.
{'ID': '144_UK_DocL_V1_ConsrvationOfFuelAndPower'}
For roofs insulated at ceiling level, the long-term protection of the insulation layer should be considered: boarded areas should be <e1>provided above the insulation</e1> to <e2>give access for maintenance</e2>.
selection
339fc78c-a2f2-481c-a410-3aeb41e24b8a
Solid walls constructed of coursed brickwork or blockwork should be at least as thick as 1/16 of the storey height.
{'ID': '32_UK_DocA_Structure'}
Solid walls constructed of coursed brickwork or blockwork should be at least as <e1>thick</e1> as 1/16 of the storey <e2>height</e2>.
none
4d80c4d1-08ee-481a-9f9c-e9151ce1094d
The area of windows, roof windows, rooflights and doors should not exceed 25 of the total floor area of the dwelling.
{'ID': '421_UK_DocL_V1_ConsrvationOfFuelAndPower'}
The area of windows, roof windows, rooflights and <e1>doors</e1> should not exceed <e2>25</e2> of the total floor area of the dwelling.
none
7d877df3-9aa7-4dff-a64d-5356a66c944d
In public outdoor and indoor spaces, and in business and service premises, a handrail must continue at least 300 millimetres past the start and end points of the structure, and in the case of stairs or ramps that have a width exceeding 2.4 metres and are located in assembly areas, it must also be placed so as to divide the passageway into parts no wider than the abovementioned width.
{'ID': '59_Finnish_SafetyOfUse'}
In <e1>public</e1> <e2>outdoor and indoor spaces</e2>, and in business and service premises, a handrail must continue at least 300 millimetres past the start and end points of the structure, and in the case of stairs or ramps that have a width exceeding 2.4 metres and are located in assembly areas, it must also be placed so as to divide the passageway into parts no wider than the abovementioned width.
selection
c2c49207-78b3-42b0-8b61-ad506f5a80e2
In hard water areas, suitable measures should be taken to treat the feed water to water heaters and the hot water circuit of combination boilers to reduce lime-scale accumulation.
{'ID': '381_UK_DocL_V1_ConsrvationOfFuelAndPower'}
In hard water areas, suitable <e1>measures</e1> should be taken to <e2>treat the feed water to water heaters and the hot water circuit of combination boilers to reduce lime-scale accumulation</e2>.
selection
7c44934c-61e1-4904-a493-1aa360ccc7d1
The building shall be constructed so that the combined dead,imposed and wind loads are sustained and transmitted by it to the ground: (a) safely; and (b) without causing such deflection or deformation of any part of the building, or such movement of the ground, as will impair the stability of any part of another building.
{'ID': '1_UK_DocA_Structure'}
The building shall be constructed so that the combined dead,imposed and wind loads are <e1>sustained</e1> and transmitted by it to the ground: (a) safely; and (b) <e2>without causing such deflection or deformation of any part of the building, or such movement of the ground, as will impair the stability of any part of another building</e2>.
selection
d3e7a947-536e-4a49-9823-e27fc0f68b27
Length of landings to be at least equal to the width of the ramp.
{'ID': '66_UK_DocK_ProtectionFromFalling'}
<e1>Length</e1> of landings to be at least equal to the <e2>width</e2> of the ramp.
greater-equal
0cfe8c0e-45e4-4c4c-bf9b-906e26e28c75
There should be sufficient space for people to approach the building, pass others who are travelling in the opposite direction and carry out all necessary manoeuvres.
{'ID': '43_UK_DocM_V2_AccessAndUseOfBuildings'}
There should be sufficient space for <e1>people</e1> to approach the building, pass others who are travelling in the opposite direction and <e2>carry out all necessary manoeuvres</e2>.
none
457ecdc0-8247-4ad4-9beb-3b7a31cfa0fd
All public areas, including lavatory accommodation, public telephones and external terraces should be accessible.
{'ID': '138_UK_DocM_V2_AccessAndUseOfBuildings'}
All <e1>public areas</e1>, including lavatory accommodation, public telephones and external terraces should be <e2>accessible</e2>.
necessity
a7e4ad57-ea09-4d8e-8b3a-4d33447237ab
The free opening of the vertical hatch or window of an emergency exit must be at least 600 millimetres in height and 500 millimetres in width; however, the sum of these must be at least 1,500 millimetres.
{'ID': '83_Finnish_SafetyOfUse'}
The free opening of the vertical hatch or <e1>window</e1> of an emergency exit must be at least 600 millimetres in height and 500 millimetres in <e2>width</e2>; however, the sum of these must be at least 1,500 millimetres.
none
bfc6b7af-2aa8-4c6c-8d4d-1b86f8a67eb5
The total supply air flow should be distributed proportionately to the volume of each habitable room.
{'ID': '105_UK_DocF_V1_Ventilation'}
The <e1>total supply air flow</e1> should be <e2>distributed proportionately to the volume of each habitable room</e2>.
necessity

CODE-ACCORD: A Corpus of Building Regulatory Data for Rule Generation towards Automatic Compliance Checking

The CODE-ACCORD corpus contains annotated sentences from the building regulations of England and Finland and has been developed as part of the Horizon European project for Automated Compliance Checks for Construction, Renovation or Demolition Works (ACCORD). The corpus is in English, and it consists of both the English Building Regulations and the English translation of the Finnish National Building Code.

Data Annotation

CODE-ACCORD is mainly focused on extracting information from text to support rule generation. There are two key types of information found in the text: named entities and relations, which are essential for comprehending the ideas conveyed in natural language. Hence, this dataset primarily focused on annotating entities and relations.

Four categories were considered for entity annotation: (1) object, (2) property, (3) quality and (4) value. The relations annotations span in ten categories: (1) selection, (2) necessity, (3) part-of, (4) not-part-of, (5) greater, (6) greater-equal, (7) equal, (8) less-equal, (9) less and (10) none. Please refer to our Annotation Stragety for more details about the categories and sample annotations.

Data Splits

Both entity and relation-annotated data consist of two data splits named train and test. The train split forms 80% of the full dataset, while the remaining 20% belongs to the test split.

Entities

The format of an entity data file is as follows:

Attribute Description
example_id Unique ID assigned for each sentence
content Original textual content of the sentence
processed_content Tokenised (using NLTK's word_tokenize package) textual content of the sentence
label Entity labelled sequence in IOB format
metadata Additional information of sentence (i.e. original approved document from which the sentence is extracted)

Using Data

The train and test splits of entity-annotated data can be loaded into Pandas DataFrames using the following Python code.

from datasets import Dataset
from datasets import load_dataset

train = Dataset.to_pandas(load_dataset('ACCORD-NLP/CODE-ACCORD-Entities', split='train'))
test = Dataset.to_pandas(load_dataset('ACCORD-NLP/CODE-ACCORD-Entities', split='test'))

Relations

The format of a relation data file is as follows:

Attribute Description
example_id Unique ID assigned for each sentence
content Original textual content of the sentence
metadata Additional information of sentence (i.e. original approved document from which the sentence is extracted)
tagged_sentence Sentence with tagged entity pair
relation_type Category of the relation in between the tagged entity pair

Using Data

The train and test splits of relation-annotated data can be loaded into Pandas DataFrames using the following Python code.

from datasets import Dataset
from datasets import load_dataset

train = Dataset.to_pandas(load_dataset('ACCORD-NLP/CODE-ACCORD-Relations', split='train'))
test = Dataset.to_pandas(load_dataset('ACCORD-NLP/CODE-ACCORD-Relations', split='test'))

Citation

More details about data annotation, statistics, and distribution are available in the following paper.

@article{hettiarachchi2024code,
  title={{CODE-ACCORD}: A Corpus of Building Regulatory Data for Rule Generation towards Automatic Compliance Checking},
  author={Hettiarachchi, Hansi and Dridi, Amna and Gaber, Mohamed Medhat and Parsafard, Pouyan and Bocaneala, Nicoleta and Breitenfelder, Katja and Costa, Gon{\c{c}}al and Hedblom, Maria and Juganaru-Mathieu, Mihaela and Mecharnia, Thamer and Park, Sumee and Tan, He and Tawil, Abdel-Rahman H. and Vakaj, Edlira},
  journal={arXiv preprint arXiv:2403.02231},
  year={2024},
  url={https://arxiv.org/abs/2403.02231}
}
Downloads last month
2
Edit dataset card

Models trained or fine-tuned on ACCORD-NLP/CODE-ACCORD-Relations