Details provided to Patra sir.
BVLINE ECO 80 Test Stand
Detail to be provided of PT 100 sensor.
Found convoyed not start off backside. Operator side problem
Cleantech
Autocycle not start
Cleaned pallet
Kadia
Pallet clamp problem ( 05 no pallet )
Cheked found coolant flow problem so flow adjusted and need to check direction of nozzle.
ELB Wheel
Burned mark on job.
Coolant temperature checked
ELB Rim
Temperatures need to check
Found hydraulic motor, not start So started hydraulic motor
Piston Coining
Cycle N start.
Brush changing d1.
Deburring Machine
Brush change
Manually d1 the cylinder movement.
Piston Coining
Cylinder not operate
Restarted the printer properly, setting the paper
Assembly stations of CH06
Printer ne2rk problem.
USB Port is Alright then machine found hang then restarted the machine.
Durr Ultrasonic
Controller usb port not working.
Manually tightening d1 the fitting.
Test Rig D
Fitting loose from the shaft.
Fume extractor filters cleaning d1, then found 2 wires are broken. The new wire fitting d1. Then fume extractor setting d1 Machine under observation
Studer 2 (451)
Fume extractor not working
Found only 1 job have problem. so changed job and taking trial cobot working properly
Kadia
Cobot not picking job.
Found unloading side door not open so manually door opened and
Cleantech
Unloading side not working
Found downside reed switch signal missing. So adjusted sensor.
Piston Coining
Door problem.
found clamping sensor not working, so adjusted sensor properly.
Test Rig D1
Clamping problem
Both machine drain motor height adjusted
Test Rig E1 & E2
Drain motor height problem
Checked and found problem
Assembly stations of CH06
Piston coining pressure problem.
Found wheel guard not operating so make machine reset and stoped wheel checked valve stuck, make stuck
Studer Favorit
Wheel guard problem.
Checked found job fell down inside machine. Manually recovered job
Cleantech
Job fell down inside machine.
Found Basket Stuck so manually recovered abundant trial taken working properly.
Durr Ultrasonic
Basket stuck.
Found plc communication disconnected due to plc error. so make reset.
Assembly stations of CH03
Dust seal problem
Found height adjusted
Jerk Testing
Cap gun problem.
So fitting properly tightened.
Assembly stations of CH03
air Leakage
Manually based positioning d1.
Durr Ultrasonic
Basket base position problem
Checked and wheel guard sensor setting d1.
Studer Favorit
Wheelguard problem
found coolant nozzle Blocked. Cleaning d1
ELB Wheel
Job burning mark.
Machine restarted
Studer
Door problem.
sensor setting done.
Studer 1 (450)
Grippers sensor problem.
Checked and key replaced.
Studer Favorit
Door key broken.
Grieper alignment setting d1.
Studer 1 (450)
Gripper job stuck problem.
Cleaned PT line filter
Test Rig H1 & H2
Relief pressure high low pt line filter choke.
Cleaned PT line filter
Test Rig G2
Relief pressure high low pt line filter choke.
Fixed torque gun from line 5 to line 6.
Durr Ultrasonic
To fix torque gun.
Homing d1.
Nissin
Job stuck.
Fixture properly set.
Durr Ultrasonic
Basket in out fixture broken.
Found suction filter chok so cleaned the filter.
Studer
Chiller pump not working properly.
Changed with new 1
Test Rig D
Stud broken
Checked all them capacitor connection connected neutral to star and then found that wire is not properly connected. So connected them and relay changed with new 1
Jerk Testing
Indian motor not rotate
Changed sensor because found that damaged
Assembly stations of CH02
Emergency ball absent alarm came.
Changed bag filter and wire filter.
Nissin
Pressure not developing.
Pipe interchanged
BVLINE Assembly Station(Single Stage)
Air leak cycle not start
Properly door locked.
Test Rig E1
Door not looking
Weekly pm completed. Some PM point spending.
Test Rig G1 & G2
Weekly PM
Weekly pm completed. Some PM point spending.
Nissin
Weekly PM
Checked relay found that relay continuously on so removed that relay and interchanged with new
Test Rig G1
Motor rotating continuously.
sensor setting done.
Assembly stations of CH04
Emergency ball absent alarm
Weekly pm completed. Some PM point spending.
Cleantech
weekly pm
Weekly pm completed. Some PM point spending.
Piston Coining
weekly pm
Return line filter cleaning
Test Rig D1
Pt line pressure high
Manually operated base position of basket
Durr Ultrasonic
Basket stuck
Maintenance interval alarm reset and cycle started
Durr Ultrasonic
Maintenance interval B alarm
All sensor cleaning d1
Stahli S/F Grinding Machine 2
Production hood alarm
Checked basket properly not locked by operator. so MCB released and manually operated base position basket.
Durr Ultrasonic
Conveyer Motor tripped and basket stuck
check cable disconnected press button so cable soldering d1
Assembly stations of CH02
Assembly line 1st station pressure relief valve gun not working.
Torque increased manually.
Assembly station 1
check valve gun torque low
Found clamping sensor not on so sensor adjustment d1
Test Rig D1
Clamping error.
Found MPCB trip so released and also son foam on water. So suggested to add deformer.
Durr Ultrasonic
Work tank to FT 1 time exceeded
Scanner restarted.
Assembly station 3
Scanner not working
Found error and door locking unit so machine restarted.
Test Rig G2
Door lnot lock
3 time setup changed
Test Rig E1
Set up to be change
Weekly pm completed. Some PM point spending.
Studer
Weekly PM
Weekly pm completed. Some PM point spending.
Deburring Machine
Weekly PM
Checked flood tank 1 at minimum level. So water filling d1
Durr Ultrasonic
Cycle not start
Mainline hydraulic filter cleaned.
BVLINE ECO 80 Test Stand
Contamination valve high
Level indicator replaced
Studer
Coolant level indicator to be replaced.
sensor adjustment d1.
Assembly station 3
Dust seal sensor disturb.
sensor adjustment d1& teaching d1
Assembly station 3
Dust seal sensor disturb.
Bearing replaced an alignment d1.
ELB Rim
Cutting wheel bearing replaced.
Checked and flow set.
ELB Rim
Coolant flow problem
Gripper replaced an alignment d1.
Studer 1 (450)
Job alignment problem
Air FRL replaced
Studer Favorit
Air leakage
Machine restarted
Studer
Emergency alarm came
Checked cable faulty replaced cable
EMAG Rim
Z axis motor megar check
FRL unit replaced.
EMAG Rim
Air leakage from FRL unit
1st shifts pending PM completed.
Assembly stations of CH02
Plan work
Gun not operate so found relay faulty changed the relay
Assembly stations of CH02
Screw tightening gun problem.
Air leak station problem found master job ok so found setup not properly adjusted.
Durr Ultrasonic
Air leak problem
Unloading side basket not going downside, so taking manually working ok.
Cleantech
Unloading side. Convoyer problem.
Unloading door problem so manually recovered.
Studer
Unloading door problem
Found door not close so close door manually and started machine.
Durr Ultrasonic
Emergency active
so water top up d1.
Studer 1 (450)
Oil separator problem.
Checked and found machine stuck during cycle time due to said axis vibration. So make velocity valve decrease after that working. OK
Centre Lapping
Z- Axis vibration problem
Found reed switch not working. In open time. So adjust reed switch taking trial. OK,
Cleantech
Dresser not working.
Downside reed switch not working. So adjusted
Piston Coining
Door problem.
Stopper properly tightened
Durr Ultrasonic
Basket stuck.
Found x axis encoder cap removed, but not found dirty but yet clean and trial bending.
Kapp Rim
X axis problem
Cleaned filter
Test Rig G2
PT line filter choke
Cleaned filter
Test Rig H2
PT line filter choke
Oil separator pump making noise, so found bolt stucked inside pump. So cleaned pump
Durr Ultrasonic
Process cicuit broken/ Trip
FRL unit fitted properly,
Durr Ultrasonic
Need to fit FRL unit on torque Gun
Repaired Gun
Assembly stations of CH06
Need to repair
SO checked & manually recovered
Cleantech
Job Stuck
Manually recovered
Nissin
Job height detection sensor problem
Manually restarted then setting done,
Assembly stations of CH04
Height sensor problem
Relay replaced
Assembly stations of CH02
Pressure relief gun stuck repeatedly
Found tail stock barrel movement hard, so tail stock servicing done,
Studer Favorit
Tail stock not operated
Manually recovered basket & handle tightened with cable tie.
Durr Ultrasonic
Basket stuck
Handle removed from SS-03 klein but SS-01 machine not fitted because SS-01 klein machine N/A for production side. ( Kept on dept)
Klein 2
Machine handle replaced with SS-01 Klein
Checked & found bolt stuck inside pump housing, removed the bolt.
Durr Ultrasonic
Oil separator spray pump continiously tripping