did
int64
0
671
query
stringlengths
6
865
name
stringlengths
1
75
datatype
stringclasses
6 values
unit
stringclasses
5 values
IRDI
stringlengths
20
21
metalabel
int64
1
37
0
internationally unique and unambiguous article number for products and services (Global Trade Item Number)
GTIN
STRING
null
0173-1#02-AAO663#003
1
1
unique product order identifier of the supplier
product article number of supplier
STRING
null
0173-1#02-AAO736#004
1
2
13-digit numeric code, identifying all the standardized material items of supply as they have been recognized by the United States Department of Defense
National stock number
STRING_TRANSLATABLE
null
0173-1#02-AAN075#003
7
3
Characteristic to differentiate between different products of a product family or special variants
Product type
STRING_TRANSLATABLE
null
0173-1#02-AAO057#002
7
4
Short description of the product (short text)
Manufacturer product designation
STRING_TRANSLATABLE
null
0173-1#02-AAW338#001
7
5
Name of the supplier or vendor of a device/name of supplier which provides the customer with a product or a service
name of supplier
STRING
null
0173-1#02-AAO735#003
1
6
legally valid designation of the natural or judicial person which is directly responsible for the design, production, packaging and labeling of a product in respect to its being brought into circulation
Manufacturer name
STRING
null
0173-1#02-AAO677#002
1
7
alphanumeric character sequence assigned to a fabricated product, which allows the date, time and circumstances of fabrication to be traced
fabrication number
STRING
null
0173-1#02-AAO674#004
1
8
Unique combination of numbers and letters used to identify the device once it has been manufactured
Serial number
STRING_TRANSLATABLE
null
0173-1#02-AAM556#002
7
9
Date from which the production and / or development process is completed or from which a service is provided completely
Date of manufacture
null
null
0173-1#02-AAR972#002
13
10
Unique global identification of the product using an universal resource identifier (URI)
URI of the product
STRING_TRANSLATABLE
null
0173-1#02-AAY811#001
7
11
Fully qualified domain name of the manufacturer of a product using a universal resource identifier (URI)
URI of manufacturer
null
null
0173-1#02-ABA669#001
13
12
pressure for a component on the basis of materials used and on the basis of calculation rules at the specified operating temperature
maximum allowable working pressure
REAL_MEASURE
null
0173-1#02-ABB705#001
19
13
Rate of flow at the point of best efficiency
Optimum rate of flow
REAL_MEASURE
null
0173-1#02-ABC048#001
19
14
Total head developed by the pump at a rate of flow corresponding to the best efficiency
Optimum head
REAL_MEASURE
null
0173-1#02-ABC046#001
19
15
Maximum permissible head at which the pump can be continuously operated without suffering damage
Maximum allowable head
REAL_MEASURE
null
0173-1#02-ABB545#001
19
16
Speed corresponding to the motor used according to the name plate ratings
nominal speed
REAL_MEASURE
null
0173-1#02-BAA580#006
19
17
describes the nominal power consumption
Nominal power consumption
REAL_MEASURE
W
0173-1#02-AAI843#002
20
18
nominal voltage is the specified value which shows the voltag in normal operation given by the manufacturer or supplier
Nominal voltage
REAL_MEASURE
V
0173-1#02-AAF583#004
21
19
Highest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used
Maximum allowable outlet pressure
REAL_MEASURE
null
0173-1#02-ABC196#001
19
20
Lowest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used
Minimum allowable outet pressure
REAL_MEASURE
null
0173-1#02-ABC197#001
19
21
highest speed for continuous operation recommended by the manufacturer
maximum allowable continuous speed
REAL_MEASURE
null
0173-1#02-ABB544#001
19
22
Minimum permissible head at which the pump can be operated without suffering damage
Minimum allowable head
REAL_MEASURE
null
0173-1#02-ABC040#001
19
23
Ten times the logarithm to the base 10 of the ratio of the square of the sound pressure, p, to the square of a reference value, p0, expressed in decibels
Sound pressure level
REAL_MEASURE
null
0173-1#02-AAO419#004
19
24
comprising a fluid together with substances in solid or gaseous states, whether due to deliberate addition or a change of state caused by a change in conditions
multi-phase
BOOLEAN
null
0173-1#02-ABC083#001
25
25
2nd level of a 3 level manufacturer specific product hierarchy
Manufacturer product family
STRING_TRANSLATABLE
null
0173-1#02-AAU731#001
7
26
web site address where information about the product or contact is given
adress of additional link
STRING
null
0173-1#02-AAQ326#002
1
27
guideline, stipulation or legislation used for determining conformity
guideline for confirmity declaration
STRING
null
0173-1#02-AAO856#003
1
28
Speed of rotation at which the frequency of vibration (or its multiples) corresponds to the rotor resonant (lateral or torsional)
Critical speed
REAL_MEASURE
null
0173-1#02-ABA888#001
19
29
Rotor resonant frequency calculated assuming that the rotor is supported only at its bearings and that the bearings are of infinite stiffness
Dry critical speed
REAL_MEASURE
null
0173-1#02-ABB129#001
19
30
Rotor resonant frequency calculated considering the additional support and damping produced by the action of the pumped fluid within rotor
Wet critical speed
REAL_MEASURE
null
0173-1#02-ABC073#001
19
31
Speed that characterizes a pump in terms of its speed, flow rate per impeller eye, i.e. total flow for single-flow impeller, half flow for double-flow impeller, at the best efficiency point and head per stage at maximum impeller diameter
Specific speed
REAL_MEASURE
null
0173-1#02-ABC063#001
19
32
Speed that characterizes a pumps cavitation performance in terms of its speed, optimum rate of flow per impeller eye at best efficiency point and NPSH3 at best efficiency point for the first stage at maximum impeller diameter
Suction-specific speed
REAL_MEASURE
null
0173-1#02-ABC067#001
19
33
highest pressure, excluding hydrostatic testing, to which the seal can be subjected while the pump is shut down
maximum static sealing pressure
REAL_MEASURE
null
0173-1#02-ABB797#001
19
34
greatest outlet pressure at the specified operating temperature at which the pump casing can be used
Maximum allowable casing working pressure
REAL_MEASURE
null
0173-1#02-ABB543#001
19
35
pressure to which the pulsation dampener is charged with dry gas prior to start of operation
Pre-charge pressure
REAL_MEASURE
null
0173-1#02-ABC051#001
19
36
Rate of flow which is extracted to activate a balance device
Balancing rate of flow
REAL_MEASURE
null
0173-1#02-ABA884#001
19
37
Rate of flow leaking from shaft seals
Leakage rate of flow
REAL_MEASURE
null
0173-1#02-ABB474#001
19
38
Lowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid
Minimum allowable thermal flow
REAL_MEASURE
null
0173-1#02-ABC041#001
19
39
Lowest flow at which the pump can be operated without it adversely affecting ist performance in terms of life expectancy, noise and vibrations
Minimum continuous stable flow
REAL_MEASURE
null
0173-1#02-ABC042#001
19
40
Lowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid
Minimum continuous thermal flow
REAL_MEASURE
null
0173-1#02-ABC043#001
19
41
Flow lost internally through clearances
Slip flow
REAL_MEASURE
null
0173-1#01-ABC058#001
19
42
displacement volume for one stroke or one cycle
geometrical flow
REAL_MEASURE
null
0173-1#02-ABB205#001
19
43
NPSH-value required for a drop of 3 % in the total head of the first stage of the pump as a standard basis for use in performance curves
Net positive suction head required for a drop of 3 %
REAL_MEASURE
null
0173-1#02-ABC045#001
19
44
minimum NPSH-value at the pump inlet connection required to give the rated or operating performance at the specified conditions
Net positive suction head required
REAL_MEASURE
null
0173-1#02-ABC044#001
19
45
Highest total head developed by a pump when this does not occur at a zero rate of flow
Head at peak point
REAL_MEASURE
null
0173-1#02-ABB342#001
19
46
relationship between the pump power input and the rate of flow given operating conditions of speed and liquid
pump curve
null
null
0173-1#02-ABC052#001
13
47
relationship between the net positive suction head required and the rate of flow at given operating conditions of speed and liquid
Pump power input curve
null
null
0173-1#02-ABC056#001
13
48
Relationship between the net positive suction head required and the rate of flow at given operating conditions of speed and liquid
Pump NPSH curve
null
null
0173-1#02-ABC055#001
13
49
relationship between the total head of the pump and the rate of flow at given operating conditions /rated conditions of speed and liquid
Pump efficiency curve
null
null
0173-1#02-ABC053#001
13
50
pump H(Q) curve where the maximum head and shut-off head are coincidental, and the total head declines continuously as the rate of flow increases
Pump H(Q) curve
null
null
0173-1#02-ABC054#001
13
51
Residual axial thrust on the pump rotor on which the thrust-bearing selection is based
Design axial load
REAL_MEASURE
null
0173-1#02-ABA890#001
19
52
Greatest value of the residual axial thrust on the pump rotor resulting from operating the pump at any condition within its allowable operating range
Maximum axial load
REAL_MEASURE
null
0173-1#02-ABB758#001
19
53
Radial load of the pump rotor for which the bearing system is selected
Design radial load
REAL_MEASURE
null
0173-1#02-ABA914#001
19
54
Greatest radial load of the pump rotor resulting from operating the pump at any condition within ist allowable operating range
Maximum radial load
REAL_MEASURE
null
0173-1#02-ABB796#001
19
55
expectation of the operating time between failures
mean time between failures (MTBF)
REAL_MEASURE
null
0173-1#02-AAQ399#005
19
56
Provides information as to whether it is possible to continuously adapt the control variable to the reference variable of the control unit of the object
Controllable
BOOLEAN
null
0173-1#02-BAI732#009
25
57
Fluid that can be pumped by the pump
Possible Fluid
STRING
null
0173-1#02-ABC050#001
1
58
Specifies whether the pump is to be operated in single, parallel or series connection.
Operating mode
STRING
null
0173-1#02-ABC085#001
1
59
control mode is to be used for the use case
Required control mode
STRING
null
0173-1#02-ABC088#001
1
60
Fluid that is handled by the pump at specified operating conditions
Fluid
STRING
null
0173-1#02-ABC075#001
1
61
maximal permitted temperature of the atmosphere surrounding the operating resource during operation
maximum ambient temperature (during operation)
REAL_MEASURE
null
0173-1#02-AAW302#002
19
62
minimal permitted temperature of the atmosphere surrounding the operating resource during operation
minimum ambient temperature (during operation)
REAL_MEASURE
null
0173-1#02-AAW301#002
19
63
Temperature determined by the given application and fluid.
Working temperature
REAL_MEASURE
null
0173-1#02-AAJ936#003
19
64
maximum value of physical and thermodynamical state variable temperature dimensioned for an operational medium
max. temperature
REAL_MEASURE
null
0173-1#02-AAF584#003
19
65
minimum maximum value of physical and thermodynamical state variable temperature dimensioned for an operational medium
min. temperature
REAL_MEASURE
null
0173-1#02-AAF585#003
19
66
Inlet pressure of the installation for the working conditions
Rated inlet pressure of the installation
REAL_MEASURE
null
0173-1#02-ABC086#001
19
67
Lowest outlet pressure that can occur during operation for the pump
Minimum outlet pressure
REAL_MEASURE
null
0173-1#02-ABC082#001
19
68
Lowest inlet pressure that can occur during operation for the pump
Minimum inlet pressure
REAL_MEASURE
null
0173-1#02-ABC081#001
19
69
horizontal plane for use as the datum for height measurement
Reference plane
REAL_MEASURE
null
0173-1#02-ABC087#001
19
70
Height of the fluid level on the outlet side of the installation or in the centre of the outlet manifold
Height of the outlet side of the installation
REAL_MEASURE
null
0173-1#02-ABC078#001
19
71
Height of the fluid level on the inlet side of the installation, or in the centre of the inlet manifold
Height of the inlet side of the installation
REAL_MEASURE
null
0173-1#02-ABC077#001
19
72
Height of the centre of the pump
Height of the pump
REAL_MEASURE
null
0173-1#02-ABC079#001
19
73
Height of the zero or centre position of the outlet manometer, or other point as defined by the manometer calibration
Height of the outlet manometer
REAL_MEASURE
null
0173-1#02-ABC093#001
19
74
Height of the zero or centre position of the inlet manometer, or other point as defined by the manometer calibration
Height of the inlet manometer
REAL_MEASURE
null
0173-1#02-ABC091#001
19
75
Ratio of the shear stress to the shear velocity acting in a liquid subjected to a plane shear motion
Dynamic viscosity
REAL_MEASURE
null
0173-1#02-BAB606#006
19
76
ratio of the dynamic viscosity to the density of the pumped liquid
Kinematic viscosity
REAL_MEASURE
null
0173-1#02-ABC096#001
19
77
quotient of the mass m divided by the spatial volume V
Density
REAL_MEASURE
null
0173-1#02-BAA356#004
19
78
Mean absolute pressure of the atmosphere measured at the place of installation of the pump
Atmospheric pressure
REAL_MEASURE
null
0173-1#02-ABC090#001
19
79
Differential pressure for the operating conditions at the guarantee point
Rated differential pressure
REAL_MEASURE
null
0173-1#02-ABC109#001
19
80
Highest pressure expected at the shaft seals during any specified operating condition and during startup and shutdown
Maximum dynamic sealing pressure
REAL_MEASURE
null
0173-1#02-ABC097#001
19
81
Lowest flow at which the pump can operate without exceeding the noise and vibration limits imposed in the order
Minimum allowable stable flow
REAL_MEASURE
null
0173-1#02-ABC101#001
19
82
proportion of gaseous substance in the liquid to be pumped, either as a contaminant or as vapour from the main body of liquid
gas content
REAL_MEASURE
null
0173-1#02-ABC076#001
19
83
generic term for different physically distinct bus systems for automation , manufacturing technology , building automation
Field bus system
STRING
null
0173-1#02-AAW334#001
1
84
ratio of the volume of the solids to the total volume of all constituents the fluid
solids volume fraction
REAL_MEASURE
null
0173-1#02-AAQ874#003
19
85
Difference between the total head at the outlet side of the pump and the total head at the inlet side of the pump
Pump total head
REAL_MEASURE
null
0173-1#02-ABC108#001
19
86
Difference between the NPSH datum plane and the reference plane
Height of the NPSH datum plane
REAL_MEASURE
null
0173-1#02-ABC092#001
19
87
Minimum NPSH available at the inlet area of the pump as determined by the conditions of the installation for a specified rate of flow
Net positive suction head available
REAL_MEASURE
null
0173-1#02-ABC102#001
19
88
Rated flow at the inlet area of the installation divided by the inlet area of the installation
Mean rated velocity at inlet area of the installation
REAL_MEASURE
null
0173-1#02-ABC098#001
19
89
Rated flow at the outlet area of the installation divided by the inlet area of the installation
Mean rated velocity at outlet area of the installation
REAL_MEASURE
null
0173-1#02-ABC099#001
19
90
Power required by the pump at the rated conditions
Pump rated power input
REAL_MEASURE
null
0173-1#02-ABC107#001
19
91
maximum boundary value of temperature range in a specified temperature, in which an operating unit can be used, without serious changes of assigned features, depending on the exposure time. Temporal restrictions like short-time or durability have to be stated
max. temperature range
REAL_MEASURE
null
0173-1#02-AAH176#003
19
92
Greatest value of pump efficiency obtained at given operating conditions
Pump best efficiency
REAL_MEASURE
null
0173-1#02-ABC104#001
19
93
minimum boundary value of the temperature range, in which an operating unit can be used, without serious changes of assigned features, depending on the exposure time. Temporal restrictions like short-time or durability have to be stated
min. temperature range
REAL_MEASURE
null
0173-1#02-AAH177#003
19
94
quantitative information relating to the utilization duration in years
Useful life
null
null
0173-1#02-BAF286#005
13
95
Number of revolutions of the pump in a given time required to meet the rated conditions
Rated speed
REAL_MEASURE
null
0173-1#02-ABC110#001
19
96
Time interval from first use until the instant when a limiting state is reached
useful life
null
null
0173-1#02-ABC113#001
13
97
passed time period after comissioning of a system, sub-system, component or piping
Operating time
REAL_MEASURE
null
0173-1#02-AAZ825#001
19
98
Time interval when maintenance is carried out on an item including technical, logistic and internal administrative delays
Maintenance time
REAL_MEASURE
null
0173-1#02-ABA719#001
19
99
Part of the maintenance time when active maintenance is carried out on an item
Active maintenance time
REAL_MEASURE
null
0173-1#02-ABA713#001
19

Dataset Card for "eclassCorpus"

This Dataset consists of names and descriptions from ECLASS-standard pump-properties. It can be used to evaluate models on the task of matching paraphrases to the ECLASS-standard pump-properties based on their semantics.

Downloads last month
2
Edit dataset card