### Human: The specified system is currently in the storage system initialization process. Only one initialization process can run at one time:### Assistant:This message displays when the wizards of two users try to initialize the same storage system on the same Service Processor (SP). Only one wizard can initialize a storage system. Two options are available when this error displays in a dialog box; end user can click Retry or Cancel. When the error does not display in a dialog box, but rather inline, look for another SP by serial number or wait a while and try again later. |
### Human: Unable to start SysManager. Make sure the storage system is running and in manual startup mode:### Assistant:Turn the storage system on and make sure it is running in manual startup mode. This message displays either in a dialog box or inline. If the message displays in a dialog box, end user can click Retry or Cancel in the wizard. If the message appears inline, end user can only click Next in the wizard. |
### Human: Could not communicate with the server. Make sure end user is currently connected to the network:### Assistant:This message displays when the client computer that is running the wizard cannot communicate with the SP, such as when network connectivity is lost. The error can occur for one of the following reasons: Network connectivity is lost. The SP is no longer running. The SP is not plugged into the network. The SP IP address has been changed. |
### Human: Could not communicate with the storage system. Make sure it is running and connected to the network. ### Assistant:This message can display if the HPE 3PAR Operating System (OS) loses network connectivity, either by becoming unplugged or by going down for some other reason. This message displays either in a dialog box or inline. If the message displays in a dialog box, end user can click Retry or Cancel in the wizard. If the message appears inline, end user can only click Next in the wizard. |
### Human: Setup encountered an unknown error ({0}). Contact HPE Support for help. ### Assistant:This message displays in a dialog box with Retry and Cancel buttons, where {0} is the error number. |
### Human: Unable to execute the command. All required data was not sent to the SP server. Contact HPE Support for help. ### Assistant:This message displays as an inline error on the bottom of the wizard page. |
### Human: No uninitialized storage system with the specified serial number could be found. Make sure the SP is on the same network as the specified storage system.### Assistant:This message displays as an inline error on the bottom of the wizard page. In order for the Storage System Setup Wizard to work, the storage system must be on the same network as the SP, and end user must type in the serial number of the storage system in order for the SP to find it. If either of these conditions is not met, this error message displays. Verify that the serial number end user entered for the SP is correct, and then do one of the following: Move the SP or storage system so that they are on the same network. Use a different SP to set up the storage system. |
### Human: Unable to gather the storage system information. Make sure the specified storage system is running HPE 3PAR OS 3.1.2 or later. For more help, contact HPE Support. ### Assistant:This message displays as an inline error on the bottom of the wizard page. The error might be caused by a defect in the Storage System Setup Wizard code or by unexpected information being returned in the CLI. |
### Human: The SP encountered an unknown error while finding the specified storage system. Contact HPE Support for help. ### Assistant:This message displays as an inline error on the bottom of the wizard page. |
### Human: The SP does not have a suitable HPE 3PAR OS version installed for the specified storage system. Use SPOCC to install HPE 3PAR OS version {0}. ### Assistant:This message displays as an inline error on the bottom of the wizard page. The SP needs to have the same Major.Minor.Patch TPD package as the storage syste's HPE 3PAR OS. If the package is not the same, then the SP does not know how to communicate with the HPE 3PAR OS. {0} will be the version of the TPD package that the user must install so that the SP will work with the storage system. |
### Human: The SP does not have an HPE 3PAR OS version installed. Use SPOCC to install an HPE 3PAR OS package. ### Assistant:This message displays as an inline error on the bottom of the wizard page when no TPD package is installed. The SP needs a TPD package installed in order to communicate with an HPE 3PAR StoreServ Storage system. |
### Human: The storage system has not yet discovered all the drive types. Make sure there are no cage problems. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. It occurs when the HPE 3PAR StoreServ Storage is unable to determine all the drive types that are connected to the cage. Wait for about 5 minutes for drive discovery to complete. If the error persists, contact HPE Support. |
### Human: The storage system has not yet discovered all the drive positions. Make sure there are no cage problems. ### Assistant:Wait for about 5 minutes for drive position discovery to complete. If the error persists, contact HPE Support. |
### Human: The storage system found an error while checking node health. Details are listed below. {0} appears to be offline. Make sure the node is plugged in all the way and powered on. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. {0} is the name of the node that appears to be offline. Turn the storage system on and make sure the node is plugged into the backplane. |
### Human: The storage system found an error while checking node health. Details are listed below. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. {0} is the port location with the problem. Make sure the port is plugged into the node. |
### Human: The storage system found an error while checking port health. Details are listed below. Port {0} appears to be offline. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. Information listed below the message is the CLI output for the checkhwconfig command, which occurs when the SP does not recognize the command, allowing to see the output. |
### Human: The storage system found an error while checking port health. Details are listed below. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. {0} is the location of the port with the problem. |
### Human: The storage system found an error while checking cabling health. Details are listed below. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. The message is followed by a list of errors. The errors may include: Cage {0} is connected to the same node twice through ports {1} and {2}. Re-Cable this cage. This error displays if a cage is connected to the same node twice. {0} will be the name of the cage and {1} and {2} will be the port locations where the cage is connected. Re-Cable the cage using best practices. Cage {0} appears to be missing a connection to a node. It does have a connection on port {1}. Connect the loop pair. This message displays if a cage is connected to only one node. {0} will be the name of the cage, and {1} will be the single port to which the cage is connected. Re-Cable the cage using best practices. Cage {0} is not connected to the same slot and port on the nodes it is connected to. Re-Cable this cage. This message displays if a cage is connected to different slots, ports, and nodes. {0} will be the name of the cage with the problem. Re-Cable the cage using best practices. |
### Human: The storage system found an error while checking cabling health. Details are listed below. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. Information listed below the message is the CLI output for the checkhwconfig command, which occurs when the SP does not recognize the command, allowing to see the output. |
### Human: The storage system found an error while checking cage health. The firmware upgrade succeeded, but cage {0} has not come back. Contact HPE Support for help. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. This error might occur after the drive cages have had a firmware upgrade. {0} will be the name of the cage with the problem. Although the firmware upgrade may have succeeded, this error might occur if the cage does not boot back up. Contact HPE Support. |
### Human: The storage system found an error while checking cage health. Details are listed below. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. Information listed below the message is the CLI output for the checkhwconfig command, which occurs when the SP does not recognize the command, allowing to see the output. |
### Human: The storage system found an error while checking cage health. There is a problem with a drive cage that has had a firmware upgrade. Cage {0} did not come back after the firmware upgrade. Contact HPE Support for help. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. This error might occur after the drive cages have had a firmware upgrade. {0} will be the name of the cage with the problem. |
### Human: The storage system found an error while checking disk health. Details are listed below. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. Information listed below the message is the CLI output for the checkhwconfig command, which occurs when the SP does not recognize the command, allowing to see the output. |
### Human: Unable to set the storage system network configuration. The storage system's admin volume has not been created. This must be created before any networking information is set. Contact HPE Support for help. ### Assistant:This message displays in a dialog box with Retry and Cancel buttons. This error occurs if a previous command failed and the wizard did not detect the error, or if the system is rebooted for any reason during the installation. Click Cancel to close the wizard, and then begin the setup process again. |
### Human: Unable to set the storage system network configuration. An invalid name was specified. A storage system name must start with an alphanumeric character followed by any combination of the following characters: a-z, A-Z, 0-9, period (.), hyphen (-), or underscore (_). ### Assistant:This message displays in a dialog box with Retry and Cancel buttons. A storage system name must contain at least 6 characters, must begin with an alphanumeric character, and must include at least one of each of the following characters: lowercase letters (a-z); uppercase letters (A-Z); numbers (0-9); and a period (.), a hyphen (-), or an underscore (_). Click Cancel to close the wizard, and then begin the setup process again. |
### Human: Unable to set the storage system network configuration. An invalid IPv4 address was specified. ### Assistant:This message displays in a dialog box. The error occurs if the storage system detects that the defined storage system name is invalid. Click Back and specify a valid IPv4 address. |
### Human: Unable to set the storage system network configuration. An invalid subnet was specified. ### Assistant:This message displays in a dialog box. The error occurs if the storage system detects that the defined subnet address is invalid. Click Back and specify a valid subnet address. |
### Human: Unable to set the storage system network configuration. An invalid IPv4 gateway was specified. ### Assistant:This message displays in a dialog box. The error occurs if the storage system detects that the defined IPv4 gateway address is invalid. Click Back and specify a valid IPv4 gateway address. |
### Human: Unable to set the storage system network configuration. The specified IPv4 gateway address is not reachable by using the specified storage system IPv4 address. ### Assistant:This message displays in a dialog box. The error occurs if the storage system detects that the defined IPv4 gateway address could not be reached. Click Back and specify a valid IPv4 gateway address. If the error persists, contact HPE Support. |
### Human: Unable to set the storage system network configuration. The storage system IPv4 address cannot be the same as the IPv4 gateway. ### Assistant:This message displays in a dialog box. The error occurs if the storage system detects that the defined IPv4 gateway address is the same as the configured IPv4 address. Click Back and specify a different address for the IPv4 gateway address. |
### Human: Unable to set the storage system network configuration. The specified address is already in use by another machine. ### Assistant:This message displays in a dialog box. The error occurs if the storage system detects that the defined IPv4 address is already in use by another machine. Click Back and specify a different IPv4 address. |
### Human: Unable to set the storage system network configuration. The storage system could not be reached at the new IP address. Make sure the network settings are configured correctly. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. This error displays when the SP is unable to reach the storage system at the new IP address. Click Cancel to close the wizard, and then begin the setup process again. |
### Human: Unable to set the storage system network configuration. The storage system did not recognize its new IP address as being validated. ### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. This error displays when the SP reaches the storage system at the new IP but fails to recognize that the SP was able to do this. Click Back and specify a valid IP address. if the error persists, contact HPE Support. |
### Human: Unable to set the storage system NTP server. An invalid address was specified.### Assistant:This error message displays in a dialog box. This error displays if the storage system detects that the Network Time Protocol (NTP) address is invalid. Click Cancel to close the wizard, and then begin the setup process again. |
### Human: Unable to set the storage system NTP server. The storage system's admin volume has not been created. This must be created before any networking information is created. Contact HPE Support for help.### Assistant:This error message displays in a dialog box with Retry and Cancel buttons. This error occurs if a previous command failed and the wizard did not detect the error, or if the system was rebooted for any reason during installation. Click Cancel to close the wizard, and then begin the setup process again. |
### Human: Unable to set the storage system time zone. An invalid time zone was specified.### Assistant:This error message displays in a dialog box. This error occurs if the storage system detects that an unfamiliar time zone was selected. Click Back and specify a valid time zone. |
### Human: Unable to set the storage system time zone. The storage system saw the time zone as invalid.### Assistant:This error message displays in a dialog box. This error occurs if the storage system detects that an unfamiliar time zone was selected. Click Back and specify a valid time zone. |
### Human: Unable to set the storage system time. An invalid time was specified.### Assistant:This error message displays in a dialog box. This error occurs if the storage system detects that an unfamiliar time zone was selected. Click Back and specify a valid time zone. |
### Human: Unable to set the storage system time. The storage system saw the time as invalid.### Assistant:This error message displays in a dialog box. This error occurs if the storage system detects that an invalid time zone was selected. Click Back and specify a valid time zone. |