Text Generation
Transformers
English
mixtral
legal
conversational
Inference Endpoints
d-delaurier's picture
Upload 11 files
30e605a
raw
history blame
5.49 kB
{"prompt":"Model: Date:\nAccessories:\nJob Name: Type:\n800.533.3948 β€’ www.barronltg.com\nSpecifications are subject to change without notice.\nInstallation must be performed in accordance with\nBarron Lighting Group installation instructions.\nPage 1 of 2\n400U Series\nUniversal Die-Cast Aluminum LED Exit\nFEATURES & BENEFITS\nβ€’ Universal style - includes 2 faceplates, a backplate and\nmounting canopy\nβ€’ Suitable for Damp Locations\nβ€’ California Energy Commission (CEC) compliant\nVersatile and easy to install, the 400U Series is constructed out\nof premium grade heavy-duty die-cast aluminum for long lasting\ndurability. Giving you a contemporary look that withstands tough\nconditions, this corrosion proof universal luminaire comes in a variety\nof colors to fit your needs.\nSPECIFICATIONS\nIllumination: Long-life, high-intensity, red or green LEDs.\nHousing: Die-cast aluminum with power coated finish\nInput: 120/277VAC dual primary, 60Hz.\nBattery: Maintenance-free NiCad battery.\nRun Time: UL Listed 90 minute emergency run time, 24\nhour recharge time.\nElectrical: Low Voltage Disconnect\nLegend: Fully-illuminated 6” characters with 3/4” stroke\nand field-selectable directional chevrons.\nMounting: Ceiling, end or wall mounted, canopy included.\nFinishes: Black, Brushed Aluminum or White\nOptions: G2 = Self-test/Self-diagnostics\nCertfications: UL Listed for Damp Locations and meets or\nexceeds the following: NEC requirements and\nNFPA 101.\nWarranty: Any component that fails due to a\nmanufacturing defect is guaranteed for five\nyears with a separate five year prorated\nwarranty on the battery. The warranty does not\ncover physical damage, abuse or instances\nof uncontrollable natural forces. See the full\nExitronix warranty document for detailed\ninformation. (Terms and Conditions apply)\n10800052 Rev 15\n5.5” 4.5”\n8.5” 9.0”\n12.5” 2.1”\nORDERING INFORMATION Example: 400U-WB-BA-G2\nSeries Power Source Finish Options (Factory Installed)\n400S = Red Single-face LB = AC Only BA = Brushed Aluminum with Aluminum Face G22 = Self-test/Self-diagnostics\nG400S = Green Single-face WB = With Battery BB = Black with Black Face\n400U1 = Red Universal 2CI1 = 120V 2 Circuit Input BL = Black with Aluminum Face\nG400U1 = Green Universal 2CI7 = 277V 2 Circuit Input WW = White with White Face\nAccessories3 (Field Installed)\nNotes 400U-VL-TRH-KIT = Tamper/Vandal-Resistant Hardware\n1 Universal includes 2nd exit face and backplate WG-S = Wire Guard (Back Mount)\n2 G2 not available with LB, 2CI1 or 2CI7 option XG-1 = Poly Guard (Back Mount)\n3 Order as separate line item XG-3 = Poly Guard (Ceiling Mount)\n800.533.3948 β€’ www.barronltg.com\nSpecifications are subject to change without notice.\nInstallation must be performed in accordance with\nBarron Lighting Group installation instructions.\nPage 2 of 2\nCONSTRUCTION\nThe Exitronix 400U series is constructed of a rugged die-cast aluminum\nbody with soft corners designed for traditional mounting as well as\nconduit entry and pendant mounting. Clear finish on brushed face\nprevents fingerprints or other surface impurities. Field selectable chevron\nknockouts are concealed and easily removed. All units are supplied with\nmounting canopy for back, top or end mounting.\nILLUMINATION\nIllumination is accomplished utilizing high-intensity, long-life LEDs\nexceeding UL 924 requirements for brightness and uniformity. Starting\nat only 2W, LEDs provide excellent illumination while maximizing energy\nefficiency.\nELECTRICAL\nInput\nDual-voltage input 120/277VAC @ 60Hz, 2.8W.\nNickel Cadmium Battery - NiCad (WB Only)\nExitronix nickel cadmium batteries are maintenance-free.\nTwo-circuit Operation (2CI1 or 2CI7)\nTwo-circuit input allows for a primary and auxiliary power source to\nbe connected to the emergency unit that does not contain a battery.\nApplications include those with inverters or alternate backup power\nsources.\nSolid-state Transfer\nThe circuit features solid-state switching for emergency lamps,\neliminating concerns of damaged contact or mechanical failures\nassociated with relays. The switching circuit detects a loss of line voltage\nand automatically switches to emergency mode.\nTest Button\nThe test button is easy to locate and provides manual verification of the\ntransfer circuit and emergency lamps.\nINSTALLATION\nInstalls in minutes with easy-to-read instructions and detailed diagrams.\nNo special hardware or tools necessary. Internally housed components\nand battery eliminate the risk of damage during installation. Mounting\ncanopy included.\nOPTIONS\nGuardian Self-Test/Self-Diagnostics (Option: G2)\nThe Guardian bi-color circuit is factory preset; without any field\nadjustments needed. It continuously monitors the performance condition\nof the AC power, battery supply and charging circuitry.\nThe intent of this option is to provide visual signaling to identify fault at\nthe exit. Fault indicators are as follow:\nBattery Disconnection: (Steady RED)\nBattery Recharge Failure: (Flashing RED)\nBattery Failure: (RED Blinking '2' times)\nLED Failure: (RED Blinking '3' times)\nVandal-Resistant Kit (Accessory: 400U-VL-TRH-KIT)\nVandal-resistant hardware adds an additional layer of protection to unit,\npreventing intentional or unintentional abuse.\nCONFORMANCE TO CODES & STANDARDS\nThe 400U Series is UL Listed for Damp Locations and meets or exceeds\nthe following: UL 924, CEC, NEC requirements and NFPA 101.\n10800052 Rev 15"}