"question": "How much time do we have when battery low alarm is shown?", | |
"id": 679806, | |
"answers": [ | |
{ | |
"answer_id": 740398, | |
"document_id": 1379050, | |
"question_id": 679806, | |
"text": "a β battery low β message displaying at the technical alarm information area of screen and an audible system alarm indicate approximate 5 minutes of battery life remaining . you should connect the monitor to an ac power source when the message is displayed ", | |
"answer_start": 227, | |
"answer_end": 484, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What will happen if the monitor can not find ac power?", | |
"id": 679801, | |
"answers": [ | |
{ | |
"answer_id": 740393, | |
"document_id": 1379050, | |
"question_id": 679801, | |
"text": "when it is unable to be connected to the ac power , the battery can be used to supply power , and at this time it is unnecessary to use the electrical wires , and the instrument can be switched on directly", | |
"answer_start": 1, | |
"answer_end": 206, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What is the average lifetime of the battery of this monitor?", | |
"id": 679810, | |
"answers": [ | |
{ | |
"answer_id": 740402, | |
"document_id": 1379050, | |
"question_id": 679810, | |
"text": "the average life span of this type of battery is approximately three years", | |
"answer_start": 551, | |
"answer_end": 625, | |
"answer_category": "SHORT" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should we do when battery change is needed?", | |
"id": 679812, | |
"answers": [ | |
{ | |
"answer_id": 740404, | |
"document_id": 1379050, | |
"question_id": 679812, | |
"text": "when replacement becomes necessary , contact a qualified service representative to perform the replacement ", | |
"answer_start": 628, | |
"answer_end": 735, | |
"answer_category": "SHORT" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "what are the steps for installing the battery?", | |
"id": 679817, | |
"answers": [ | |
{ | |
"answer_id": 740409, | |
"document_id": 1379050, | |
"question_id": 679817, | |
"text": "nstall battery the battery storage is located at the bottom of the monitor , following the steps to install a battery . 1 ( cid:451 ) open the battery gate according to the direction marked on the monitor . 2 ( cid:451 ) turn the baffle up clockwise . 3 ( cid:451 ) push the battery into the gate with the electrode point to the bottom of the monitor . 4 ( cid:451 ) after pushing the battery inside the storage withdraw , the baffle turn back to the middle position . 5 ( cid:451 ) close the gate . ( cid:132 )", | |
"answer_start": 1080, | |
"answer_end": 1591, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What are the steps for uninstalling the battery?", | |
"id": 679820, | |
"answers": [ | |
{ | |
"answer_id": 740412, | |
"document_id": 1379050, | |
"question_id": 679820, | |
"text": "uninstall battery ( cid:20 ) ( cid:451 ) open the battery gate according to the direction marked on the monitor . ( cid:3 ) 2 ( cid:451 ) turn the baffle up clockwise . 3 ( cid:451 ) take out the battery . then close the gate . 3.3 connecting to the central monitor system", | |
"answer_start": 1592, | |
"answer_end": 1864, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " when it is unable to be connected to the ac power , the battery can be used to supply power , and at this time it is unnecessary to use the electrical wires , and the instrument can be switched on directly . ( cid:41 ) note : a β battery low β message displaying at the technical alarm information area of screen and an audible system alarm indicate approximate 5 minutes of battery life remaining . you should connect the monitor to an ac power source when the message is displayed . ( cid:41 ) note : this monitor contains a rechargeable battery . the average life span of this type of battery is approximately three years . when replacement becomes necessary , contact a qualified service representative to perform the replacement . 3-2 patient monitor user β s manual ( cid:41 ) disposal note : should this product become damaged beyond repair , or for some reason its service life is considered to be at an end , please observe all local , state , and federal regulations that relate to the disposal of products that contain lead , batteries , plastics , etc . ( cid:132 ) install battery the battery storage is located at the bottom of the monitor , following the steps to install a battery . 1 ( cid:451 ) open the battery gate according to the direction marked on the monitor . 2 ( cid:451 ) turn the baffle up clockwise . 3 ( cid:451 ) push the battery into the gate with the electrode point to the bottom of the monitor . 4 ( cid:451 ) after pushing the battery inside the storage withdraw , the baffle turn back to the middle position . 5 ( cid:451 ) close the gate . ( cid:132 ) uninstall battery ( cid:20 ) ( cid:451 ) open the battery gate according to the direction marked on the monitor . ( cid:3 ) 2 ( cid:451 ) turn the baffle up clockwise . 3 ( cid:451 ) take out the battery . then close the gate . 3.3 connecting to the central monitor system ( cid:48 ) warning : accessory equipment connected to the analog and digital interface must be certified according to the respective iec standards ( e.g . iec 60950 for data processing equipment and iec 60601-1:1995 for medical equipment ) . furthermore all configurations shall comply with the valid version of the system standard iec 60601-1-1 .", | |
"document_id": 1379050 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "What are the steps for shutting down the monitor?", | |
"id": 679852, | |
"answers": [ | |
{ | |
"answer_id": 740444, | |
"document_id": 1379052, | |
"question_id": 679852, | |
"text": "shutting off the monitor please follow these steps to shut off the monitor : ( cid:132 ) confirm that the patient monitoring is finished . ( cid:132 ) disconnect the cables and sensors form patient . ( cid:132 ) confirm that the monitoring data is stored or cleared . ( cid:132 ) press the power switch , then a dialog will pop up to ask you make sure the shut-off operation . select β ok β to shut off the monitor . if the monitor can β t be switched off normally , forced close the monitor by pressing and holding the power switch more than 5s . this may cause some damages to the device", | |
"answer_start": 225, | |
"answer_end": 814, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What are different configuration of this monitor?", | |
"id": 679859, | |
"answers": [ | |
{ | |
"answer_id": 740450, | |
"document_id": 1379052, | |
"question_id": 679859, | |
"text": "the monitor configuration is consist of standard and non-standard parameter configuration", | |
"answer_start": 1185, | |
"answer_end": 1274, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "what is the difference between standard and non-standard configuration?", | |
"id": 679862, | |
"answers": [ | |
{ | |
"answer_id": 740454, | |
"document_id": 1379052, | |
"question_id": 679862, | |
"text": "and their operation methods are basically the same , the standard configuration includes 5-lead ecg , resp , spo , single temp and nibp 2 modules , and the non-standard parameter configuration includes dual temp , ibp , co and ag modules", | |
"answer_start": 1277, | |
"answer_end": 1514, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does the standard screen mode work?", | |
"id": 679891, | |
"answers": [ | |
{ | |
"answer_id": 740483, | |
"document_id": 1379052, | |
"question_id": 679891, | |
"text": "standard the ecg waveform of one lead is displayed on the uppermost region above the waveforms ( this lead is called key monitoring lead and is set by the βΉ ecg1 > option in βΉ ecg > ) , and the waveforms below are displayed differently according to different configurations", | |
"answer_start": 1809, | |
"answer_end": 2082, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does nibp review screen mode work?", | |
"id": 679893, | |
"answers": [ | |
{ | |
"answer_id": 740485, | |
"document_id": 1379052, | |
"question_id": 679893, | |
"text": "nibp review the recent groups of nibp measurement results are displayed below the waveforms and the measurement records can be browsed by turning the trim knob", | |
"answer_start": 2135, | |
"answer_end": 2294, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does big numeric screen mode work?", | |
"id": 679896, | |
"answers": [ | |
{ | |
"answer_id": 740488, | |
"document_id": 1379052, | |
"question_id": 679896, | |
"text": "big numerics the main parameters are displayed in big font , e.g .", | |
"answer_start": 2311, | |
"answer_end": 2377, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " 2 . install the paper with the thermal side upwards . 3 . close the recorder with a section of paper outside of the storage . for detailed operation information , refer to fig . 3-6-1 fig . 3-6-1 install recording paper 3.7 shutting off the monitor please follow these steps to shut off the monitor : ( cid:132 ) confirm that the patient monitoring is finished . ( cid:132 ) disconnect the cables and sensors form patient . ( cid:132 ) confirm that the monitoring data is stored or cleared . ( cid:132 ) press the power switch , then a dialog will pop up to ask you make sure the shut-off operation . select β ok β to shut off the monitor . if the monitor can β t be switched off normally , forced close the monitor by pressing and holding the power switch more than 5s . this may cause some damages to the device . 3-5 patient monitor user β s manual chapter 4 operation instructions for the monitor ( cid:41 ) note : in each menu , press ( cid:455 ) previous ( cid:456 ) to return to the previous menu and press the ( cid:455 ) main ( cid:456 ) button to return to main screen . in all the dialogue windows , there is help info to indicate the current operation . ( cid:41 ) note : the monitor configuration is consist of standard and non-standard parameter configuration , and their operation methods are basically the same , the standard configuration includes 5-lead ecg , resp , spo , single temp and nibp 2 modules , and the non-standard parameter configuration includes dual temp , ibp , co and ag modules . 2 4.1 screen mode in the < select screen > of the < main setup > menu , 8 kinds of different screen display modes can be selected , namely : standard , nibp review , big numerics , short trend , 7 leads , 12 leads , oxycrg , other bed . they are respectively showed as follow : 1 ( cid:709 ) standard the ecg waveform of one lead is displayed on the uppermost region above the waveforms ( this lead is called key monitoring lead and is set by the < ecg1 > option in < ecg > ) , and the waveforms below are displayed differently according to different configurations . 4-1 patient monitor user β s manual 2 ( cid:709 ) nibp review the recent groups of nibp measurement results are displayed below the waveforms and the measurement records can be browsed by turning the trim knob . 3 ( cid:709 ) big numerics the main parameters are displayed in big font , e.g .", | |
"document_id": 1379052 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "How does the short trend screen mode work?", | |
"id": 679905, | |
"answers": [ | |
{ | |
"answer_id": 740497, | |
"document_id": 1379053, | |
"question_id": 679905, | |
"text": "short trend the short trend diagram relevant to the parameters is displayed on the upper-left corner of the waveform ", | |
"answer_start": 89, | |
"answer_end": 206, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does the 7-lead screen mode work?", | |
"id": 679911, | |
"answers": [ | |
{ | |
"answer_id": 740503, | |
"document_id": 1379053, | |
"question_id": 679911, | |
"text": "7-leads the ecg waveforms of 7-lead are displayed in the waveform display zone , they are i , ii , iii , avr , avl , avf , and v- respectively ", | |
"answer_start": 222, | |
"answer_end": 365, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does the 12-lead screen mode work?", | |
"id": 679917, | |
"answers": [ | |
{ | |
"answer_id": 740509, | |
"document_id": 1379053, | |
"question_id": 679917, | |
"text": "12-leads the 12-lead ecg waveforms are displayed in the waveform display zone , they are i , ii , ( cid:267 ) ( cid:15 ) avr , avl , avf , v1 , v2 , v3 , v4 , v5 , v6 . in order to facilitate the diagnosis and analysis of heart disease , monitor is especially designed with displaying 12-lead ( all-lead ) ecg synchronously on screen . select ( cid:455 ) 12 leads ( cid:456 ) in the βΉ select screen > of the βΉ main setup > menu . the waveform is composed of left and right regions , and displayed in the left region are ecg waveforms of limb leads and on the right are the ecg waveforms of chest leads ", | |
"answer_start": 417, | |
"answer_end": 1019, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does oxycrg screen mode work?", | |
"id": 679918, | |
"answers": [ | |
{ | |
"answer_id": 740510, | |
"document_id": 1379053, | |
"question_id": 679918, | |
"text": "oxycrg the trend diagrams of hr , spo and resp within 8 minutes are displayed under the 2 waveforms", | |
"answer_start": 1035, | |
"answer_end": 1134, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does the other bed screen mode work?", | |
"id": 679922, | |
"answers": [ | |
{ | |
"answer_id": 740514, | |
"document_id": 1379053, | |
"question_id": 679922, | |
"text": "other bed the info for other beds is showed below the waveforms , including one waveform and parts of parameters . among them , through βΉ bed no > , the number of online machine can be selected and through βΉ bed wave > the waveform display of other beds can be selected . press βΉ run > to initiate monitoring of other beds , and press βΉ stop > to terminate the present monitoring of other beds . switching from monitoring of other beds screen to other screens will automatically terminate the present monitoring of other beds", | |
"answer_start": 1187, | |
"answer_end": 1712, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " hr , spo , nibp , resp and etco . 2 2 4-2 patient monitor user β s manual 4 ( cid:709 ) short trend the short trend diagram relevant to the parameters is displayed on the upper-left corner of the waveform . 5 ( cid:709 ) 7-leads the ecg waveforms of 7-lead are displayed in the waveform display zone , they are i , ii , iii , avr , avl , avf , and v- respectively . 4-3 patient monitor user β s manual 6 ( cid:709 ) 12-leads the 12-lead ecg waveforms are displayed in the waveform display zone , they are i , ii , ( cid:267 ) ( cid:15 ) avr , avl , avf , v1 , v2 , v3 , v4 , v5 , v6 . in order to facilitate the diagnosis and analysis of heart disease , monitor is especially designed with displaying 12-lead ( all-lead ) ecg synchronously on screen . select ( cid:455 ) 12 leads ( cid:456 ) in the < select screen > of the < main setup > menu . the waveform is composed of left and right regions , and displayed in the left region are ecg waveforms of limb leads and on the right are the ecg waveforms of chest leads . 7 ( cid:709 ) oxycrg the trend diagrams of hr , spo and resp within 8 minutes are displayed under the 2 waveforms . 4-4 patient monitor user β s manual 8 ( cid:709 ) other bed the info for other beds is showed below the waveforms , including one waveform and parts of parameters . among them , through < bed no > , the number of online machine can be selected and through < bed wave > the waveform display of other beds can be selected . press < run > to initiate monitoring of other beds , and press < stop > to terminate the present monitoring of other beds . switching from monitoring of other beds screen to other screens will automatically terminate the present monitoring of other beds . 4.2 main menu 4-5 patient monitor user β s manual select screen such eight display modes as standard , nibp review , big numerics , short trend , 7 leads , 12 leads , oxycrg and other bed can be selected . and the display mode varies according to different manufacturer configurations . monitor setup click and open the dialog of monitor configuration . conduct some configurations of the monitor . trend review click and open the dialog of trend browse . browse trend tables or trend diagrams . alarm review click and open the dialog of alarm event review . browse alarm events .", | |
"document_id": 1379053 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "What does alarm volume do in monitor's setup?", | |
"id": 679950, | |
"answers": [ | |
{ | |
"answer_id": 740542, | |
"document_id": 1379054, | |
"question_id": 679950, | |
"text": "alarm volume set the alarm volume and options are off , 1 , 2 , 3 , 4 , 5 , 6 . after one selection is made , a testing beep will be produced", | |
"answer_start": 1097, | |
"answer_end": 1238, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What does the beep volume do in monitor's setup?", | |
"id": 679946, | |
"answers": [ | |
{ | |
"answer_id": 740538, | |
"document_id": 1379054, | |
"question_id": 679946, | |
"text": "beep volume set the volume of beep and options are off , 1 , 2 , 3 , 4 , 5 , 6 . after one selection is made , a testing beep will be produced ", | |
"answer_start": 952, | |
"answer_end": 1095, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What will happen after initiating the monitoring of a new patient?", | |
"id": 679941, | |
"answers": [ | |
{ | |
"answer_id": 740533, | |
"document_id": 1379054, | |
"question_id": 679941, | |
"text": "after initiating the monitoring of a new patient , the data of historical patients will be completely eliminated", | |
"answer_start": 781, | |
"answer_end": 893, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What does patient info option do in main menu?", | |
"id": 679937, | |
"answers": [ | |
{ | |
"answer_id": 740529, | |
"document_id": 1379054, | |
"question_id": 679937, | |
"text": "patient info click and open the dialog of patient info . it provides the input and browse of patient info", | |
"answer_start": 462, | |
"answer_end": 567, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What does drug dose calc option do in main menu?", | |
"id": 679939, | |
"answers": [ | |
{ | |
"answer_id": 740531, | |
"document_id": 1379054, | |
"question_id": 679939, | |
"text": "drug dose calc click and open the dialog of drug concentration . open the calculation tool of drug concentration and it provides the calculation and printing of drug calculation and titration tables", | |
"answer_start": 570, | |
"answer_end": 768, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " arr review click and open the dialog of arrhythmia review . browse the waveforms and events of arrhythmia . alarm setup click and open the dialog of alarm configuration . conduct configuration of alarm parameters . new patient terminate the monitoring of the current patient and initiate the monitoring of a new patient . pressing the option will delete the monitoring data of the current patient and patient info and initiate the monitoring of a new patient . patient info click and open the dialog of patient info . it provides the input and browse of patient info . drug dose calc click and open the dialog of drug concentration . open the calculation tool of drug concentration and it provides the calculation and printing of drug calculation and titration tables . caution : after initiating the monitoring of a new patient , the data of historical patients will be completely eliminated . 4-6 patient monitor user β s manual 4.2.1 monitor setup beep volume set the volume of beep and options are off , 1 , 2 , 3 , 4 , 5 , 6 . after one selection is made , a testing beep will be produced . alarm volume set the alarm volume and options are off , 1 , 2 , 3 , 4 , 5 , 6 . after one selection is made , a testing beep will be produced . wave setup click and open the dialog of waveform configuration . conduct the customization of screen waveforms and relevant waveform displays can be selected according to needs . select module click and open the dialog of module configuration . some of the modules not in current use can be switched off , and after switching-off , the relevant parameters and waveforms will not be displayed and no alarm will be made . trend storage click and open the dialog of configuration of trend storage .", | |
"document_id": 1379054 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "How should Potential equalization conductor terminal be connected", | |
"id": 679716, | |
"answers": [ | |
{ | |
"answer_id": 740308, | |
"document_id": 1379043, | |
"question_id": 679716, | |
"text": "connect the potential equalization conductor terminal to the potential equalization system with the green and yellow potential equalization cable ", | |
"answer_start": 412, | |
"answer_end": 558, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should monitor connected with", | |
"id": 679713, | |
"answers": [ | |
{ | |
"answer_id": 740305, | |
"document_id": 1379043, | |
"question_id": 679713, | |
"text": " the monitor must be connected with potential equalization system individual ", | |
"answer_start": 333, | |
"answer_end": 410, | |
"answer_category": "SHORT" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What will happen if the protection earth system is damaged?", | |
"id": 679718, | |
"answers": [ | |
{ | |
"answer_id": 740310, | |
"document_id": 1379043, | |
"question_id": 679718, | |
"text": "if the protection earth system is damaged , the potential equalization system can take on the safety function of protection earth conductor ", | |
"answer_start": 560, | |
"answer_end": 700, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What will happen when an alarm occurs?", | |
"id": 679721, | |
"answers": [ | |
{ | |
"answer_id": 740313, | |
"document_id": 1379043, | |
"question_id": 679721, | |
"text": " when an alarm occurs , outputting the nurse call signal to remind nurse", | |
"answer_start": 864, | |
"answer_end": 936, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " co /ag socket 2 2 . spo socket 2 3 . ecg socket 4 . ibp socket ( ibp1 and ibp2 ) 5 . nibp cuff connector 6 . temp socket ( temp1 and temp2 ) 7 . receptacle for dehydration flask 1.4.3 rear view 5 6 7 4 3 2 1 1 . ac input socket 2 . potential equalization conductor terminal base on the requirements of safety and anti-interference , the monitor must be connected with potential equalization system individual . connect the potential equalization conductor terminal to the potential equalization system with the green and yellow potential equalization cable . if the protection earth system is damaged , the potential equalization system can take on the safety function of protection earth conductor . 3 . auxiliary output connector connect to the device , such as oscillograph to output analog signals . it also can be connected to nurse call system in hospital . when an alarm occurs , outputting the nurse call signal to remind nurse . 4 . secondary display socket connect to standard vga display for secondary displaying . 5 . usb socket connect to usb device .", | |
"document_id": 1379043 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "what is the most reliable method of patient monitoring?", | |
"id": 679775, | |
"answers": [ | |
{ | |
"answer_id": 740367, | |
"document_id": 1379047, | |
"question_id": 679775, | |
"text": "remember that the most reliable method of patient monitoring combines close personal surveillance and correct operation of monitoring equipment ", | |
"answer_start": 249, | |
"answer_end": 393, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "Can we rely on the audible alarm system?", | |
"id": 679774, | |
"answers": [ | |
{ | |
"answer_id": 740366, | |
"document_id": 1379047, | |
"question_id": 679774, | |
"text": "do not rely exclusively on the audible alarm system for patient monitoring . adjustment of alarm volume to a low level or off during patient monitoring may result in a hazard to the patient ", | |
"answer_start": 57, | |
"answer_end": 247, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should we do when monitoring new patient?", | |
"id": 679777, | |
"answers": [ | |
{ | |
"answer_id": 740369, | |
"document_id": 1379047, | |
"question_id": 679777, | |
"text": "to clear patient data when monitoring a new patient , you must clear all previous patient data from the system . to accomplish this , shut down the device , and then turn on it . selecting ( cid:455 ) new patient ( cid:456 ) in ( cid:455 ) main setup ( cid:456 ) menu can also clear the previous patient data ", | |
"answer_start": 1007, | |
"answer_end": 1316, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should we do before putting system into use?", | |
"id": 679776, | |
"answers": [ | |
{ | |
"answer_id": 740368, | |
"document_id": 1379047, | |
"question_id": 679776, | |
"text": "before use 2-3 patient monitor user β s manual before putting the system into operation , please visually inspect all connecting cables for signs of damage . damaged cables and connectors must be replaced immediately . before using the system , the operator must verify that it is in correct working order and operating condition . periodically , and whenever the integrity of the product is in doubt , test all functions ", | |
"answer_start": 496, | |
"answer_end": 918, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should we do in case of interfacing with other equipment?", | |
"id": 679778, | |
"answers": [ | |
{ | |
"answer_id": 740370, | |
"document_id": 1379047, | |
"question_id": 679778, | |
"text": "leakage current test when interfacing with other equipment , a test for leakage current must be performed by qualified biomedical engineering personnel before using with patients", | |
"answer_start": 1579, | |
"answer_end": 1757, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " verify that all equipment is working correctly . alarms do not rely exclusively on the audible alarm system for patient monitoring . adjustment of alarm volume to a low level or off during patient monitoring may result in a hazard to the patient . remember that the most reliable method of patient monitoring combines close personal surveillance and correct operation of monitoring equipment . the functions of the alarm system for monitoring the patient must be verified at regular intervals . before use 2-3 patient monitor user β s manual before putting the system into operation , please visually inspect all connecting cables for signs of damage . damaged cables and connectors must be replaced immediately . before using the system , the operator must verify that it is in correct working order and operating condition . periodically , and whenever the integrity of the product is in doubt , test all functions . cables route all cables away from patient β s throat to avoid possible strangulation . to clear patient data when monitoring a new patient , you must clear all previous patient data from the system . to accomplish this , shut down the device , and then turn on it . selecting ( cid:455 ) new patient ( cid:456 ) in ( cid:455 ) main setup ( cid:456 ) menu can also clear the previous patient data . disposal of package dispose of the packaging material , please observe the applicable waste control regulations and keeping it out of children β s reach . explosion hazard do not use this equipment in the presence of flammable anesthetics , vapors or liquids . leakage current test when interfacing with other equipment , a test for leakage current must be performed by qualified biomedical engineering personnel before using with patients . battery power the device is equipped with a battery pack . the battery discharges even when the device is not in use . store the device with a fully charged battery and take out the battery , so that the service life of the battery will not be shortened . disposal of accessories and device disposable devices are intended for single use only .", | |
"document_id": 1379047 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "What should we do for connecting the device to the power?", | |
"id": 679788, | |
"answers": [ | |
{ | |
"answer_id": 740380, | |
"document_id": 1379049, | |
"question_id": 679788, | |
"text": "connecting to power 3.2.1 ac power ( cid:30 ) confirm the rated ac current is : ac 100-240v 50/60hz ( cid:30 ) use the electrical wires provided along with the instrument , put its output end plug ( round headed ) into the ac current socket on the back of the monitor , and the plug of input end into a grounded socket of the mains ( it must be a special socket of the hospital ) , connect the monitor through the earth one of electrical wires", | |
"answer_start": 60, | |
"answer_end": 503, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How does the monitor can be switched off?", | |
"id": 679793, | |
"answers": [ | |
{ | |
"answer_id": 740385, | |
"document_id": 1379049, | |
"question_id": 679793, | |
"text": "the equipment has no mains switch . the equipment is switched completely only by disconnecting the power supply from the wall socket . the wall socket has to be easily accessible", | |
"answer_start": 1096, | |
"answer_end": 1274, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What is happening when the indicating light is green and orange?", | |
"id": 679789, | |
"answers": [ | |
{ | |
"answer_id": 740381, | |
"document_id": 1379049, | |
"question_id": 679789, | |
"text": "when the indicating light above the power switch on the panel of the monitor is green , it means the ac power is on . and when the monitor is not connected to ac power and the dc battery is used as the power source , the indicating light is orange ", | |
"answer_start": 517, | |
"answer_end": 765, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "How is the runtime of the battery?", | |
"id": 679798, | |
"answers": [ | |
{ | |
"answer_id": 740390, | |
"document_id": 1379049, | |
"question_id": 679798, | |
"text": "run time of the batteries is according to the usage and configuration of monitor . nibp and spo monitoring and the usage of the recorder will drain battery power faster than 2 other parameters", | |
"answer_start": 1971, | |
"answer_end": 2163, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "When is the battery charged?", | |
"id": 679795, | |
"answers": [ | |
{ | |
"answer_id": 740387, | |
"document_id": 1379049, | |
"question_id": 679795, | |
"text": "the battery is charged when the monitor is connected to ac power", | |
"answer_start": 1763, | |
"answer_end": 1827, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " in case of problems , please contact us or our agent . 3.2 connecting to power 3.2.1 ac power ( cid:30 ) confirm the rated ac current is : ac 100-240v 50/60hz ( cid:30 ) use the electrical wires provided along with the instrument , put its output end plug ( round headed ) into the ac current socket on the back of the monitor , and the plug of input end into a grounded socket of the mains ( it must be a special socket of the hospital ) , connect the monitor through the earth one of electrical wires . ( cid:30 ) when the indicating light above the power switch on the panel of the monitor is green , it means the ac power is on . and when the monitor is not connected to ac power and the dc battery is used as the power source , the indicating light is orange . ( cid:48 ) warning : the monitor must be connected to a properly installed power outlet with protective earth contacts only . if the installation does not provide for a protective earth conductor , disconnect the monitor from the power line and operate it on battery power . 3-1 patient monitor user β s manual ( cid:41 ) note : the equipment has no mains switch . the equipment is switched completely only by disconnecting the power supply from the wall socket . the wall socket has to be easily accessible . ( cid:41 ) note : for measurements in or near the heart we recommend connecting the monitor to the potential equalization system . use the green/yellow potential equalization cable and connect it to the pin labeled with the symbol . 3.2.2 battery power the monitor has a battery pack to provide power to the monitor whenever ac power is interrupted . the battery is generally referred to as the β battery β . you must charge the battery before using it . there is no external charger . the battery is charged when the monitor is connected to ac power . to assure a fully charged battery that is ready for use , we recommend that the monitor be plugged into ac power whenever it is not in use . run time of the batteries is according to the usage and configuration of monitor . nibp and spo monitoring and the usage of the recorder will drain battery power faster than 2 other parameters . ( cid:41 ) note : when the monitor is connected to ac power , the battery is in a state of being recharged .", | |
"document_id": 1379049 | |
} | |
] | |
}, | |
{ | |
"paragraphs": [ | |
{ | |
"qas": [ | |
{ | |
"question": "What should we check when we are configuring the device?", | |
"id": 679823, | |
"answers": [ | |
{ | |
"answer_id": 740415, | |
"document_id": 1379051, | |
"question_id": 679823, | |
"text": "everybody who connects additional equipment to the signal input part or signal output part configures a medical system , and is therefore responsible that the system complies with the requirements of the valid version of the system standard iec 60601-1-1", | |
"answer_start": 1, | |
"answer_end": 255, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should user do if they intend to connect the monitor to the central monitoring system?", | |
"id": 679831, | |
"answers": [ | |
{ | |
"answer_id": 740423, | |
"document_id": 1379051, | |
"question_id": 679831, | |
"text": "if the user intends to connect the monitor to the central monitoring system , plug its connecting electrical cable into the network connector at the back of the monitor", | |
"answer_start": 344, | |
"answer_end": 512, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What kind of central monitoring system, this monitor can be connected to?", | |
"id": 679836, | |
"answers": [ | |
{ | |
"answer_id": 740428, | |
"document_id": 1379051, | |
"question_id": 679836, | |
"text": "this monitor can only be connected to the central monitoring system provided by manufacturer , do not attempt to connect this monitor to other central monitoring system ", | |
"answer_start": 569, | |
"answer_end": 738, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "what is the process for starting the monitor?", | |
"id": 679841, | |
"answers": [ | |
{ | |
"answer_id": 740433, | |
"document_id": 1379051, | |
"question_id": 679841, | |
"text": "starting the monitor ( cid:30 ) press the power button . the alarm indicating lamps flash , and then go out . the system gives a beep and displays the startup screen . ( cid:30 ) the startup screen disappears and the monitor enters the main screen ", | |
"answer_start": 744, | |
"answer_end": 992, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "What should we do in case of abnormal behaviour by the monitor?", | |
"id": 679844, | |
"answers": [ | |
{ | |
"answer_id": 740436, | |
"document_id": 1379051, | |
"question_id": 679844, | |
"text": "warning : in case the monitor is found to be working abnormally or indication of errors appears , please do not use this monitor for monitoring and should contact the after-sale service center as soon as possible ", | |
"answer_start": 1005, | |
"answer_end": 1218, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
}, | |
{ | |
"question": "what should we do when we want to connect the monitor to the sensors?", | |
"id": 679849, | |
"answers": [ | |
{ | |
"answer_id": 740441, | |
"document_id": 1379051, | |
"question_id": 679849, | |
"text": "connecting to various kinds of sensors connect sensor cables to the relevant sockets on the monitor and put sensors on the monitored locations on the body of the patient . refer to the relevant content of chapter 5 for details ", | |
"answer_start": 1224, | |
"answer_end": 1451, | |
"answer_category": "LONG" | |
} | |
], | |
"is_impossible": false | |
} | |
], | |
"context": " everybody who connects additional equipment to the signal input part or signal output part configures a medical system , and is therefore responsible that the system complies with the requirements of the valid version of the system standard iec 60601-1-1 . if in doubt , consult the technical service department or your local representative . if the user intends to connect the monitor to the central monitoring system , plug its connecting electrical cable into the network connector at the back of the monitor . 3-3 patient monitor user β s manual ( cid:41 ) note : this monitor can only be connected to the central monitoring system provided by manufacturer , do not attempt to connect this monitor to other central monitoring system . 3.4 starting the monitor ( cid:30 ) press the power button . the alarm indicating lamps flash , and then go out . the system gives a beep and displays the startup screen . ( cid:30 ) the startup screen disappears and the monitor enters the main screen . ( cid:48 ) warning : in case the monitor is found to be working abnormally or indication of errors appears , please do not use this monitor for monitoring and should contact the after-sale service center as soon as possible . 3.5 connecting to various kinds of sensors connect sensor cables to the relevant sockets on the monitor and put sensors on the monitored locations on the body of the patient . refer to the relevant content of chapter 5 for details . ( cid:48 ) warning : for safety reasons , all connectors for patient cables and sensor leads ( with the exception of temperature ) are designed to prevent inadvertent disconnection , should someone pull on the leads . do not route cables in a way that they may present a stumbling hazard . do not install the monitor in a location where it may drop to the patient . all consoles and brackets used must have a raised edge at the front . 3.6 preparation of recorder if the monitor you use has been provided with a recorder , before starting of monitoring please check if the recorder has had recording thermal paper installed . the thermal side ( that is the smoother side ) should face upwards and a small section should be pulled out onto the outlet of the paper ( on the right panel of the monitor ) . if record paper has been used up , following the steps to install recording paper . 3-4 patient monitor user β s manual 1 . push down the switch to open recorder .", | |
"document_id": 1379051 | |
} | |
] | |
} | |
] | |
} |