TPS56637: OCP limit for 20V input and 5V output condition
Part Number: TPS56637 Hi Expert, 1. Can below circuit continuously output 5V/6A(30W), when input is 20V? What will the thermal performance be with 5V/6A under nature cooling and typical layout condition? 2. What is the output current OCP limitation for below schematic? How to calculate and modify? 3. How will the converter respond when OCP happens?
Hi, 1, it support this application, you can use webench to evaluate the thermal. 2, OCP is fixed value, can’t be changed, you can check page5 “current limitation” to get. 3, When hit OCP, current will be limited and then Vout will drop to hit UVP, then happen hiccups, you can check page15 datasheet for details. Yuchang
Hi Expert, Thanks for the info, however I cannot find thermal performance(tested thermal image) anywhere, no matter in EVM user's guide, or in Webench. Please help check.
Hi Shenhua, Just refer to the thermal picture below from EVM for reference: 19V-5V/6A,15mins, Ta=25degC: Tc = 78.5degC 24V-5V/6A, 15mins, Ta=25degC: Tc = 85.6degC Thanks very much. Bruce