BQ34Z100-G1: self-learning ra flag shows 5555 | |
Part Number: BQ34Z100-G1 Golden learning for the gas gauge chip. Qmax sucessful update. During ra table updata period (discharging), Ra table keeps updating, but Ra_a0 flag shows 5555. I notcie that normally this ra flag should begin with ff or 00. Is that correct that ra_flag shows 5555? what does this ra_a0 flag mean? Thank you very much! | |
Has your leaning cycle done yet? 0x5555 should mean that the resistance update is still in progress. Andy | |
hi andy, thank you for your reply. Understand that 5555 means under updating. but unfortunately i still failed the learning. the ra flag never changed to 0055 until the battery finished discharge. May i know that how can i start another learning cycle? just restart the learning by RESET--DISCHARGE--RELAX--CHARGE--RELAX---DISCHARGE? Do i have to reinstal the firmware? | |