"type": "bundle",
"id": "bundle--24c2c656-e8bf-4ca2-a206-e69f101e3ef3",
"spec_version": "2.0",
"objects": [
{
"modified": "2022-10-24T15:09:07.609Z",
"name": "Block Command Message",
"description": "Adversaries may block a command message from reaching its intended target to prevent command execution. In OT networks, command messages are sent to provide instructions to control system devices. A blocked command message can inhibit response functions from correcting a disruption or unsafe condition. (Citation: Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011) (Citation: Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems March 2016)",
"kill_chain_phases": [
{
"kill_chain_name": "mitre-ics-attack",
"phase_name": "inhibit-response-function"
}
],
"x_mitre_modified_by_ref": "identity--c78cb6e5-0c4b-4611-8297-d1b8b55e40b5",
"x_mitre_platforms": [
"Field Controller/RTU/PLC/IED",
"Device Configuration/Parameters"
],
"x_mitre_domains": [
"ics-attack"
],
"x_mitre_version": "1.0",
"x_mitre_attack_spec_version": "2.1.0",
"x_mitre_data_sources": [
"Operational Databases: Process History/Live Data",
"Network Traffic: Network Traffic Flow",
"Application Log: Application Log Content",
"Operational Databases: Process/Event Alarm",
"Process: Process Termination"
],
"type": "attack-pattern",
"id": "attack-pattern--008b8f56-6107-48be-aa9f-746f927dbb61",
"created": "2020-05-21T17:43:26.506Z",
"created_by_ref": "identity--c78cb6e5-0c4b-4611-8297-d1b8b55e40b5",
"external_references": [
{
"source_name": "mitre-attack",
"url": "https://attack.mitre.org/techniques/T0803",
"external_id": "T0803"
},
{
"source_name": "Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011",
"description": "Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011 A Taxonomy of Cyber Attacks on SCADA Systems Retrieved. 2018/01/12 ",
"url": "http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6142258"
},
{
"source_name": "Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems March 2016",
"description": "Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems 2016, March 18 Analysis of the Cyber Attack on the Ukranian Power Grid: Defense Use Case Retrieved. 2018/03/27 ",
"url": "https://assets.contentstack.io/v3/assets/blt36c2e63521272fdc/blt6a77276749b76a40/607f235992f0063e5c070fff/E-ISAC_SANS_Ukraine_DUC_5%5b73%5d.pdf"
}
],
"object_marking_refs": [
"marking-definition--fa42a846-8d90-4e51-bc29-71d5b4802168"
],
"x_mitre_is_subtechnique": false
}
]
}