did
int64
0
671
query
stringlengths
6
865
name
stringlengths
1
75
datatype
stringclasses
6 values
unit
stringclasses
5 values
IRDI
stringlengths
20
21
metalabel
int64
1
37
300
actual value of the discrete input unit
discrete input value
null
null
0173-1#02-ABC146#001
13
301
actual value of the discrete output unit
discrete output value
null
null
0173-1#02-ABC142#001
13
302
user-defined value for use with fault action property
fault value
STRING
null
0173-1#02-ABC130#001
1
303
total number of transitions of the value from th off to the on state
on off cycle
INTEGER
null
0173-1#02-ABC141#001
31
304
desired operation mode of the pump
set operation mode
STRING
null
0173-1#02-ABC140#001
1
305
desired control mode of the pump
set control mode
STRING
null
0173-1#02-ABC139#001
1
306
actual status of the element
property-status
null
null
0173-1#02-ABC132#001
13
307
operation status of a machine
on/off
null
null
0173-1#02-ABC131#001
13
308
input variable to a comparing element in a controlling system, which sets the desired value of the controlled variable and is deducted from the command variable
reference variable
REAL_MEASURE
null
0173-1#02-ABC128#001
19
309
output variable of the controlling system, which is also an input variable of the controlled system
manipulated variable
STRING
null
0173-1#02-ABC125#001
1
310
variable quantity, which represents the controlled variable and is returned to the comparing element
feedback variable
REAL_MEASURE
null
0173-1#02-ABC122#001
19
311
duration of the time interval by which the output variable is shifted relative to the input variable
dead time
REAL_MEASURE
null
0173-1#02-AAM698#005
19
312
proportional element, the quotient of the variation of the output variable to the corresponding variation of the input variable
proportional action coefficient
STRING
null
0173-1#02-ABC127#001
1
313
characterization of the way and the extent to which the human operator intervenes in the control equipment
operating mode
STRING
null
0173-1#02-ABC126#001
1
314
integral element, the quotient of the time derivative of the output variable to the fixed value of the input variable
integral action coefficient
STRING
null
0173-1#02-ABC124#001
1
315
variable quantity which has, or combination of variable quantities which have, to be influenced by the control
final controlled variable
REAL_MEASURE
null
0173-1#02-ABC123#001
19
316
for a derivative element, the quotient of the value of the output variable to the value of the time derivative of the input variable
derivative action coefficient
STRING
null
0173-1#02-ABC121#001
1
317
output variable of the controlling element, which is deducted from the control difference variable and is also the input variable of the actuator
controller output variable
REAL_MEASURE
null
0173-1#02-ABC120#001
19
318
output variable of the controlled system that will be acted upon by one or more manipulated variables
controlled variable
REAL_MEASURE
null
0173-1#02-ABC119#001
19
319
difference between the reference variable and the feedback variable
control difference variable
REAL_MEASURE
null
0173-1#02-ABC118#001
19
320
variable quantity, which is not influenced by the control but is introduced into the control system from outside with the aim of making the final controlled variable follow it in a given relationship
command variable
REAL_MEASURE
null
0173-1#02-ABC117#001
19
321
absolute static pressure of the emerging mixture immediate downstream the pressure connection
Counterpressure
null
null
0173-1#02-BAJ129#007
13
322
temperature of the refrigerating agent used for cooling
Coolant temperature
REAL_MEASURE
null
0173-1#02-AAB758#006
19
323
measured rate of flow passing through the exit from the volute divided by the throat area
mean velocity at throat
REAL_MEASURE
null
0173-1#02-ABC161#001
19
324
measured power transmitted to the pump by its driver
water pump power consumption
REAL_MEASURE
null
0173-1#02-AAJ763#003
19
325
amount of the absolute value of the total head above the head, equivalent to the vapour pressure of the liquid at the particular temperature, with reference to the NPSH datum plane
net positive suction head
REAL_MEASURE
null
0173-1#02-ABC164#001
19
326
difference between the total head at the outlet side of the pump and the total head at the inlet side of the pump
lift circulating pump
REAL_MEASURE
null
0173-1#02-AAI540#004
19
327
measured dfifference between instantaneous pressure and static pressure
sound pressure
REAL_MEASURE
null
0173-1#02-ABC178#001
19
328
determined through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface
sound power
REAL_MEASURE
null
0173-1#02-ABC177#001
19
329
determined integral of the sound power, p, over a stated time interval of duration t (starting at t1 and ending at t2)
sound energy
REAL_MEASURE
null
0173-1#02-ABC175#001
19
330
measured residual force acting at right angles to the line of the shaft and derived from hydraulic forces
radial load of pump rotor
REAL_MEASURE
null
0173-1#02-ABC174#001
19
331
measured temperature of the pump
pump temperature
REAL_MEASURE
null
0173-1#02-ABC173#001
19
332
measured rate of flow leaking from shaft seals
leakage rate of flow
REAL_MEASURE
null
0173-1#02-ABC157#001
19
333
measured clearance flow between the housing and the impeller
clearance flow
REAL_MEASURE
null
0173-1#02-ABC151#001
19
334
determined power loss due clearance flows
power loss due to internal leakage
REAL_MEASURE
null
0173-1#02-ABC168#001
19
335
measured position of the axial rotor in bearing
axial rotor position
REAL_TYPE
null
0173-1#02-ABC149#001
37
336
measured residual thrust acting through the shaft derived from hydraulic or mechanical forces
axial load of pump rotor
REAL_MEASURE
null
0173-1#02-ABC148#001
19
337
ten times the logarithm to the base 10 of the ratio of the sound power of a source, p, to a reference value, p0, expressed in decibels
sound output level
null
null
0173-1#02-BAA081#005
13
338
measured oil pressure of the lubrication system
lubricating oil pressure
REAL_MEASURE
null
0173-1#02-ABC160#001
19
339
measured oil consumption of the lubricating system
lubricating oil consumption
REAL_MEASURE
null
0173-1#02-ABC159#001
19
340
measured level
level
REAL_MEASURE
null
0173-1#02-ABC158#001
19
341
part of the active maintenance time taken to perform a preventive maintenance
active preventive maintenance time
REAL_MEASURE
null
0173-1#02-ABA746#001
19
342
part of maintenance time when preventive maintenance is carried out on an item, including technical, logistic and internal administrative delay
preventive maintenance time
REAL_MEASURE
null
0173-1#02-ABA745#001
19
343
maintainability of an item determined by the design under expected conditions of maintenance and logistic support
intrinsic maintainability
REAL_MEASURE
null
0173-1#02-ABA734#001
19
344
Percent probability of a fault-free operation over the period of time specified under the reliability period under specified environmental conditions
Reliability according to norm
REAL_MEASURE
null
0173-1#02-AAY978#001
19
345
average of the time to restauration
time to restoration
REAL_MEASURE
null
0173-1#02-ABA728#001
19
346
time interval throughout which an item is in a standby state
standby time
REAL_MEASURE
null
0173-1#02-ABA726#001
19
347
average of the time to restauration
mean time to restauration
REAL_MEASURE
null
0173-1#02-ABA721#001
19
348
time interval throughout which an item is in an external disabled state
external disabled time
REAL_MEASURE
null
0173-1#02-ABA715#001
19
349
Timescale for the mean downtime
mean downtime
REAL_MEASURE
null
0173-1#02-AAO768#001
19
350
delivery which is to be expected for usual operation
normal feed flow
REAL_MEASURE
null
0173-1#02-BAJ126#007
19
351
gauge pressure of the gaseous state of a substance which is in thermodynamic equilibrium with the liquid or solid phase of the substance at a given temperature
vapor pressure (gauge)
REAL_MEASURE
null
0173-1#02-AAQ871#007
19
352
head observed at outlet area of the installation, corresponding to the sum of the height, pressure head and velocity head
total head at outlet area of the installation
REAL_MEASURE
null
0173-1#02-ABC112#001
19
353
head observed at inlet area of the installation, corresponding to the sum of the height, pressure head and velocity head
total head at inlet area of the installation
REAL_MEASURE
null
0173-1#02-ABC111#001
19
354
difference between the total head at the outlet side of the installation and the total head at the inlet side of the installation
installation total head
REAL_MEASURE
null
0173-1#02-ABC095#001
19
355
power absorbed by friction in bearings and shaft seal at given operating conditions of the pump
pump mechanical power losses
REAL_MEASURE
null
0173-1#02-ABC106#001
19
356
smallest rate of flow that the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied
Min. feed flow
REAL_MEASURE
null
0173-1#02-BAI022#005
19
357
greatest rate of flow the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied
Max. feed flow
REAL_MEASURE
null
0173-1#02-BAI023#005
19
358
proportion of the pump power input, p, delivered as pump power output, pu, at given operating conditions
pump efficiency
REAL_MEASURE
null
0173-1#02-ABC105#001
19
359
proportion of the pump power input, p, available after satisfying the mechanical power losses, pj,ab, at given operating conditions
mechanical efficiency
REAL_MEASURE
null
0173-1#02-ABC100#001
19
360
proportion of the driver power input, pmot, delivered as pump power output, pu
overall efficiency
REAL_MEASURE
null
0173-1#02-ABC103#001
19
361
proportion of pump available power input, pa, which is delivered as pump power output, pu, after satisfying the losses resulting from friction due to the relative motion of internal surfaces and internal leakage
hydraulic efficiency
REAL_MEASURE
null
0173-1#02-ABC094#001
19
362
total pressure (including velocity pressure) at the pump inlet connection less the liquid vapour pressure at the present temperature of the liquid
net positive inlet pressure available
REAL_MEASURE
null
0173-1#02-ABC084#001
19
363
greatest difference between the total energy height at the outlet side of the pump aggregate and the total energy height of the intake side of the pump aggregate at operating point
maximum feed height
REAL_MEASURE
null
0173-1#02-BAJ123#007
19
364
absolute total inlet head above the head equivalent to the vapor pressure based on the NPSH at the operating point
NPSH-nominal
REAL_MEASURE
null
0173-1#02-BAJ153#009
19
365
smallest total energy height at the outlet side of the pump aggregate to the total energy height of the admission side of the pump aggregate at operating point
minimum feed height
REAL_MEASURE
null
0173-1#02-BAJ124#008
19
366
difference between the total energy height on the outlet side of the pump aggregate and the total energy height of the intake side of the pump aggregate ruling at operating point
nominal feed height
REAL_MEASURE
null
0173-1#02-BAJ125#007
19
367
representation of the pump head plotted against the flow rate
installation NPSH curve
null
null
0173-1#02-ABB432#001
13
368
pure number calculated at the point of best efficiency
type number
STRING
null
0173-1#02-ABC068#001
1
369
pump h(q) curve where the maximum head (peak point) and shut-off head are not coincidental, or the total head does not decline continuously as the rate of flow increases
stable pump H(Q) curve
null
null
0173-1#02-ABC064#001
13
370
Hoisting height for the feed flow Q = 0
Zero-delivery height
REAL_MEASURE
null
0173-1#02-BAI147#004
19
371
power consumption at flow = 0 and speed guaranteed
Zero flow power requirement
REAL_MEASURE
null
0173-1#02-BAJ154#008
19
372
highest value of the mechanical power demand of the pump for any delivery flow under any permitted working conditions
maximum power requirement of the pump
REAL_MEASURE
null
0173-1#02-BAJ143#008
19
373
average speed given by the stroke length multiplied with the number of complete pumping cycles of the piston, plunger or piston attached to the diaphragm per minute (stroke per minute or pump crank speed)
piston velocity
REAL_MEASURE
null
0173-1#02-ABC049#001
19
374
volume remaining unswept at the end of the discharge stroke
clearance volume
REAL_MEASURE
null
0173-1#02-ABA886#001
19
375
product of geometrical displacement volume and speed of rotation or stroke frequency
geometric displacement volume
REAL_MEASURE
null
0173-1#02-ABB160#001
19
376
Volume of one unit of mass measure of a substance which is required for a single stroke
Stroke volume
REAL_MEASURE
null
0173-1#02-BAA486#003
19
377
exact, standardized agreements, to exchange data between appliances as well as processes, those which are conntected via network
supported protocol
STRING
null
0173-1#02-AAM479#008
1
378
indication whether an evaluation of the device for international comparison is present
conformity declaration present
BOOLEAN
null
0173-1#02-AAC225#007
25
379
device type according to functional principle and pumped fluid
device type
STRING
null
0173-1#02-ABC057#001
1
380
difference between instantaneous pressure and static pressure
sound pressure
REAL_MEASURE
null
0173-1#02-ABC062#001
19
381
through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface
sound power
REAL_MEASURE
null
0173-1#02-ABC061#001
19
382
ten times the logarithm to the base 10 of the ratio of the sound energy, j, to a reference value, j0, expressed in decibels
sound energy level
REAL_MEASURE
null
0173-1#02-ABC060#001
19
383
integral of the sound power, p, over a stated time interval of duration t (starting at t1 and ending at t2)
sound energy
REAL_MEASURE
null
0173-1#02-ABC059#001
19
384
highest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used
maximum allowable inlet pressure
REAL_MEASURE
null
0173-1#02-ABC205#001
19
385
free cross-sectional area of the entry opening in the inlet connection of the pump
inlet area of the pump
REAL_MEASURE
null
0173-1#02-ABC204#001
19
386
outlet pressure at which the relief valve begins to open
relief-valve set pressure
REAL_MEASURE
null
0173-1#02-ABC202#001
19
387
outlet pressure at which the relief valve will close after passing the total pump flow
relief-valve reseat pressure
REAL_MEASURE
null
0173-1#02-ABC201#001
19
388
pressure at the outlet of the relief valve when the valve is closed
relief-valve back pressure
REAL_MEASURE
null
0173-1#02-ABC200#001
19
389
outlet pressure at which the relief valve will pass the total pump flow
relief-valve accumulation pressure
REAL_MEASURE
null
0173-1#02-ABC199#001
19
390
total inlet pressure required to ensure there is sufficient margin to maintain the minimum instantaneous inlet pressure with adequate margin above the minimum liquid vapour pressure expected
net positive inlet pressure required
REAL_MEASURE
null
0173-1#02-ABC209#001
19
391
total pressure (including velocity pressure) at the pump inlet connection less the liquid vapour pressure at the present temperature of the liquid
net positive inlet pressure
REAL_MEASURE
null
0173-1#02-ABC163#001
19
392
mean velocity of the flow through the valve seat at the specified operating conditions
valve seat velocity
REAL_MEASURE
null
0173-1#02-ABC114#001
19
393
mean velocity of the flow through the valve spill area
valve spill velocity
REAL_MEASURE
null
0173-1#02-ABC115#001
19
394
ratio of the actual delivered volume at maximum pressure to the geometric displacement volume
volumetric efficiency
REAL_MEASURE
null
0173-1#02-ABC116#001
19
395
Language-independent, unambiguous code of a class within a class system
Class code of the electric motor
STRING
null
0173-1#02-AAO714#001
1
396
language-independent, unambiguous code of a class within a class system
code of class
STRING
null
0173-1#02-AAO712#002
1
397
language-independent, unambiguous code of a class within a class system
Class code of the transmission
STRING
null
0173-1#02-AAO716#001
1
398
Name and version status of the used classification system
Classification system of the electric motor
STRING
null
0173-1#02-AAO717#001
1
399
description comprising one or more words allocated to a class within a class system
description of class
STRING_TRANSLATABLE
null
0173-1#02-AAD282#006
7