input
stringclasses
1 value
instruction
stringlengths
223
3.4k
output
stringlengths
206
380
category
stringclasses
1 value
index
stringclasses
1 value
fileName
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K316)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K316", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-168", "InspectionItems": [ "検査表PCB-COM :接続確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:0", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :基板ジャンパー設定確認", "削除", "GWCZ-E013-168" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "GWCZ-E013-168", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "34cN・m", "WorkName": "ボード設定、取付(K316)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K316", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業", "★静電対策作業" ], "Words": [ "検査表PCB-COM :基板ジャンパー設定確認", "検査表PCB-COM :接続確認", "削除", "★静電対策作業", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "34cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K317)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K317", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-168", "InspectionItems": [ "検査表PCB-COM :型式・検査書チェック" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:0", "検査表PCB-COM :基板ジャンパー設定確認", "検査表PCB-COM :接続確認", "削除", "GWCZ-E013-168" ] }
{ "QualityItem": "型式確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "型式が一致する事", "Method": "目視", "RecordMethod": "GWCZ-E013-168", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K317)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K317", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-168", "InspectionItems": [ "検査表PCB-COM :基板ジャンパー設定確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:0", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :接続確認", "削除", "GWCZ-E013-168" ] }
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "GWCZ-E013-168", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K317)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K317", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-168", "InspectionItems": [ "検査表PCB-COM :接続確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:0", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :基板ジャンパー設定確認", "削除", "GWCZ-E013-168" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "GWCZ-E013-168", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "34cN・m", "WorkName": "ボード設定、取付(K317)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K317", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業", "★静電対策作業" ], "Words": [ "検査表PCB-COM :基板ジャンパー設定確認", "検査表PCB-COM :接続確認", "★静電対策作業", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "34cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "固定用ブラケット取付(CPUUNIT)", "WorkItems": [ "1. ⑤にBRACKET BRACKET を取付ける" ], "WorkPoints": [ "面合わせ", "BOX組付けネジ", "⑤BOX組付けネジを緩めて、BRACKET BRACKET を挟み込み再度ネジで締付ける" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "削除" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "EXTENDEDUNIT設定、ボード取付", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "GWCZ-E013-302" ] }
{ "QualityItem": "型式確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "型式が一致する事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "EXTENDEDUNIT設定、ボード取付", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "GWCZ-E013-302" ] }
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "スケール", "Size": "300㎜", "ToolOther": "", "WorkName": "EXTENDEDUNIT設定、ボード取付", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "貼付確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示寸法各±1㎜", "Method": "スケール", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "34cN・m", "WorkName": "EXTENDEDUNIT設定、ボード取付", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "GWCZ-E013-168", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "34cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K340)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ、ジャンパー設定確認", "★3. ⑤にPCB-COM PANEL 、⑤付属品を取付ける" ], "WorkPoints": [ "K340", "ジャンパーが無いことを確認", "CPU UNIT側で外したパネルを使用", "青マーキングし検査書に記入する事", "取付け時、オレンジ色のゴムは外す" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :型式・検査書チェック" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:7", "検査表PCB-COM :基板ジャンパー設定確認", "検査表PCB-COM :接続確認", "GWCZ-E013-302" ] }
{ "QualityItem": "型式確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "型式が一致する事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K340)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ、ジャンパー設定確認", "★3. ⑤にPCB-COM PANEL 、⑤付属品を取付ける" ], "WorkPoints": [ "K340", "ジャンパーが無いことを確認", "CPU UNIT側で外したパネルを使用", "青マーキングし検査書に記入する事", "取付け時、オレンジ色のゴムは外す" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :基板ジャンパー設定確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:7", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :接続確認", "GWCZ-E013-302" ] }
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K340)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ、ジャンパー設定確認", "★3. ⑤にPCB-COM PANEL 、⑤付属品を取付ける" ], "WorkPoints": [ "K340", "ジャンパーが無いことを確認", "CPU UNIT側で外したパネルを使用", "青マーキングし検査書に記入する事", "取付け時、オレンジ色のゴムは外す" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :接続確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:7", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :基板ジャンパー設定確認", "GWCZ-E013-302" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "34cN・m", "WorkName": "ボード設定、取付(K340)", "WorkItems": [ "★3. ⑤にPCB-COM PANEL 、⑤付属品を取付ける" ], "WorkPoints": [ "K340", "ジャンパーが無いことを確認", "CPU UNIT側で外したパネルを使用", "青マーキングし検査書に記入する事", "取付け時、オレンジ色のゴムは外す" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "検査表PCB-COM :接続確認", "★静電対策作業", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "34cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K341)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K341", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :型式・検査書チェック" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :基板ジャンパー設定確認", "検査表PCB-COM :接続確認", "削除", "GWCZ-E013-302" ] }
{ "QualityItem": "型式確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "型式が一致する事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K341)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K341", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :基板ジャンパー設定確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :接続確認", "削除", "GWCZ-E013-302" ] }
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K341)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K341", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :接続確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :基板ジャンパー設定確認", "削除", "GWCZ-E013-302" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "34cN・m", "WorkName": "ボード設定、取付(K341)", "WorkItems": [ "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K341", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "検査表PCB-COM :接続確認", "★静電対策作業", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "34cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K342)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K342", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :型式・検査書チェック" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :基板ジャンパー設定確認", "検査表PCB-COM :接続確認", "GWCZ-E013-302" ] }
{ "QualityItem": "型式確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "型式が一致する事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K342)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K342", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :基板ジャンパー設定確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :接続確認", "GWCZ-E013-302" ] }
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ボード設定、取付(K342)", "WorkItems": [ "■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する", "★2. PCB-COM のスイッチ設定確認", "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K342", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "GWCZ-E013-302", "InspectionItems": [ "検査表PCB-COM :接続確認" ], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :型式・検査書チェック", "検査表PCB-COM :基板ジャンパー設定確認", "GWCZ-E013-302" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "GWCZ-E013-302", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "34cN・m", "WorkName": "ボード設定、取付(K342)", "WorkItems": [ "★3. ⑤にPCB-COM を取付ける" ], "WorkPoints": [ "K342", "青マーキングし検査書に記入する事" ], "Tolks": [ "締付トルク 34cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "★静電対策作業", "■安全作業" ], "Words": [ "設定:1", "検査表PCB-COM :接続確認", "★静電対策作業", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "34cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程", "静電対策工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "固定用ブラケット取付(EXTENDEDUNIT)", "WorkItems": [ "1. ⑤にBRACKET BRACKET を取付ける" ], "WorkPoints": [ "面合わせ", "BOX組付けネジ", "⑤BOX組付けネジを緩めて、BRACKET BRACKET を挟み込み再度ネジで締付ける" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "増設ケーブルラベル結束", "WorkItems": [ "1. ①にLABEL を取付ける" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "GWCZ-E013-296", "InspectionItems": [ "検査表①:マーキングタイ取付確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "CN1K333", "CN1K334", "CN1K334", "CN1K333", "削除", "GWCZ-E013-296" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "GWCZ-E013-296", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①_測定準備", "WorkItems": [ "1. XYユニットチェッカーケーブルを本体エンコーダと接続する", "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『Y AxisC』をクリックし、調整用ソフトを立ち上げる", "3. 機種選択、Y軸①設定のシリアルポートとY軸②設定のシリアルポートを確認する" ], "WorkPoints": [ "フロント側", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する", "接続1", "接続2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "Y軸 ①", "Y軸 ②", "COM 2", "X5K506", "接続", "接続", "接続", "接続", "ケーブルカバー㉗", "X5K502", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "フロント側_Y軸①_測定準備", "WorkItems": [ "1. XYユニットチェッカーケーブルを本体エンコーダと接続する", "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『Y AxisC』をクリックし、調整用ソフトを立ち上げる", "3. 機種選択、Y軸①設定のシリアルポートとY軸②設定のシリアルポートを確認する" ], "WorkPoints": [ "フロント側", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する", "接続1", "接続2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "Y軸 ①", "Y軸 ②", "COM 2", "X5K506", "接続", "接続", "接続", "接続", "ケーブルカバー㉗", "X5K502", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①_信号Monitor1", "WorkItems": [ "1. チェッカー電源㉖をONにする", "2. 『起動』をクリックすると通信確認OKと表示され画面が切り替わる", "4. 『信号Monitor』をクリックする", "3. Xビームをフロント側メカストッパーまで移動する" ], "WorkPoints": [ "通信エラ-の場合はケーブル繋ぎ、チェッカー電源(ON)を確認する", "画面表示で自動ON" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "信号Monitor" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①_信号Monitor2", "WorkItems": [ "3. 『終了』を押す", "2. ScaleA、B、Cのmax値の中で最も高い数値の位置へXビームを移動する", "1. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)" ], "WorkPoints": [ "フロント側", "Xビームを移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "メーター", "メーター、及びメーター値を見ながらmax値の位置まで移動", "max 値", "メーター値" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①_信号調整START", "WorkItems": [ "1. 『信号調整Start』をクリックする", "2. 『開始』をクリックする", "3. Loopカウンターが動き出したら、Xビームをリア側に動かす", "4. 【信号を確認します】が表示されたら、Xビームをフロント側に戻す" ], "WorkPoints": [ "フロント側", "フロント側", "Xビームは50mm/sec以下で60mm以上移動させる事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号調整Start" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①_Gain設定確認", "WorkItems": [ "1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する", "2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る", "3. Xビームをフロント側メカストッパーまで移動する" ], "WorkPoints": [ "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す", "OKを確認" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "設定確認", "■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①_信号Monitor3", "WorkItems": [ "3. 『終了』を押す", "4. Xビームをフロント側メカストッパーまで移動する", "1. 『信号Monitor』をクリックする", "2. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)" ], "WorkPoints": [ "画面表示で自動ON", "フロント側", "OKを確認", "■信号強度規格_min:40以上/max:80以下", "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "信号Monitor", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "OK表示である事max値:各80以下min値:各40以上", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸②_信号Monitor1", "WorkItems": [ "4. 『終了』を押す", "1. 『信号Monitor』をクリックする", "2. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)", "3. ScaleA、B、Cのmax値の中で最も高い数値の位置へX軸を移動する" ], "WorkPoints": [ "画面表示で自動ON", "フロント側", "Xビームを移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号Monitor", "メーター、及びメーター値を見ながらmax値の位置まで移動", "メーター", "max 値", "メーター値" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸②_信号調整START", "WorkItems": [ "1. 『信号調整Start』をクリックする", "2. 『開始』をクリックする", "3. Loopカウンターが動き出したら、Xビームをリア側に動かす", "4. 【信号を確認します】が表示されたら、Xビームをフロント側に戻す" ], "WorkPoints": [ "フロント側", "Xビームは50mm/sec以下で60mm以上移動させる事", "フロント側" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号Monitor", "信号調整Start" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸②_Gain設定確認", "WorkItems": [ "1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する", "2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る", "3. Xビームをフロント側メカストッパーまで移動する" ], "WorkPoints": [ "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す", "OKを確認" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9", "Gain設定確認", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸②_信号Monitor2", "WorkItems": [ "3. 『終了』を押す", "1. 『信号Monitor』をクリックする", "4. Xビームをフロント側メカストッパーまで移動する", "2. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)" ], "WorkPoints": [ "画面表示で自動ON", "フロント側", "OKを確認", "■信号強度規格_min:40以上/max:80以下", "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "信号Monitor", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "OK表示である事max値:各80以下min値:各40以上", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①②_原点プリセット", "WorkItems": [ "2. 『原点プリセット』をクリックする", "3. 『F側SET』をクリックする", "4. 『終了』をクリックする", "1. Xビームをフロント側メカストッパーに当付ける" ], "WorkPoints": [ "D_Pos1:-18.5㎜", "D_Pos4:179.5㎜", "D_Pos2:18.5㎜", "D_Pos3:-179.5㎜", "D_Pos値は固定値_入力不要", "SET_Pos値は『0.00』_入力不要", "18.5000が表示", "-18.5000が表示", "右のOKランプ点灯", "右のOKランプ点灯", "完了ランプ点灯" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "原点プリセット", "WEPJ-G002-C02" ] }
{ "QualityItem": "原点プリセット値設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Y軸①プリセット値:-18.5㎜Y軸②プリセット値:18.5㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸_偏差測定1", "WorkItems": [ "1. Xビームをフロント側メカストッパーに当付ける", "2. 『偏差測定』をクリックする", "4. 3位置にて『データ取込』をクリックする(PCの『Enterキー』でも可)", "3. Xビームを【 0(ゼロ)】付近に移動する" ], "WorkPoints": [ "移動後の誤差は±10㎜以内にする事", "取込み位置を行き過ぎてしまった場合は、再度戻り-方向で必ず行うこと" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "※注意", "-方向で取込むことGOOD", "戻り方向で取込みはNG", "Xビーム", "Xビーム", "偏差測定" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸_偏差測定2", "WorkItems": [ "2. 『終了』をクリックする", "1. Xビームを100㎜毎移動させデータを取込む", "3. Xビームをフロント側メカストッパーに当付ける" ], "WorkPoints": [ "100㎜づつ、計10回取込", "100㎜~1000㎜まで取込む", "移動後の誤差は±10㎜以内にする事。【 0(ゼロ) 】付近取込時同様、戻り方向での取込みは禁止", "取込み位置を行き過ぎてしまった場合は、再度戻り-方向で必ず行うこと" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "0mm → データ取込 済 100mm → データ取込 ・ ・ ・ ・ ・ 1000mm → データ取込", "※注意", "-方向で取込むことGOOD", "戻り方向で取込みはNG", "Xビーム", "Xビーム" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸_偏差設定", "WorkItems": [ "1. 『偏差設定』をクリックする", "2. 『F側SET』をクリックする", "3. 『終了』をクリックする" ], "WorkPoints": [ "偏差調整値が表示されている", "右のOKランプ点灯", "右のOKランプ点灯", "完了ランプ点灯", "Y-2:偏差調整後の数値が表示", "Y-1:-18.5000が表示" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "偏差設定" ] }
{ "QualityItem": "原点プリセット値登録確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸_ストローク確認", "WorkItems": [ "2. 『ストローク確認』をクリックする", "3. フロントXビームをY軸フロントストッパーに押し当て測定する", "4. フロントXビームをY軸リアストッパーに押し当て測定する", "1. Xビームをフロント側メカストッパーに当付ける" ], "WorkPoints": [ "■規格値Y軸① -18.7mm~-18.3mmY軸② 18.3mm~18.7mm", "■規格値Y軸① 1117mm~1298.5mmY軸② -1298.5mm~-1117mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,12 Y軸ストローク確認", "検査表①:No,12 Y軸ストローク確認" ], "WorkTypes": [], "Words": [ "奥側ストローク位置", "手前側ストローク位置", "手前側ストローク位置データを記入", "ストローク確認", "奥側ストローク位置データを記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値Y軸①-18.7~-18.3㎜Y軸②18.3~18.7㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸_ストローク確認", "WorkItems": [ "2. 『ストローク確認』をクリックする", "3. フロントXビームをY軸フロントストッパーに押し当て測定する", "4. フロントXビームをY軸リアストッパーに押し当て測定する", "1. Xビームをフロント側メカストッパーに当付ける" ], "WorkPoints": [ "■規格値Y軸① -18.7mm~-18.3mmY軸② 18.3mm~18.7mm", "■規格値Y軸① 1117mm~1298.5mmY軸② -1298.5mm~-1117mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,12 Y軸ストローク確認", "検査表①:No,12 Y軸ストローク確認" ], "WorkTypes": [], "Words": [ "奥側ストローク位置", "手前側ストローク位置", "手前側ストローク位置データを記入", "ストローク確認", "奥側ストローク位置データを記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値Y軸①1117~1298.5㎜Y軸②-1298.5~-1117㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸①②_エラー履歴クリア", "WorkItems": [ "1. 『エラー履歴クリア』クリックする", "2. 『クリア』をクリックする", "3. 完了ランプ点灯を確認し『終了』をクリックする", "4. 『終了』をクリックし『×』をクリックする" ], "WorkPoints": [ "完了ランプ点灯" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "エラー履歴クリア" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_Y軸_XYチェッカー切り離し", "WorkItems": [ "1. チェッカー電源㉖をOFFにする", "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す" ], "WorkPoints": [ "フロント側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し1", "切り離し2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "Y軸 ①", "Y軸 ②", "OFF", "ON", "COM 2", "X5K506", "外す", "外す", "ケーブルカバー㉗", "X5K502", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "フロント側_Y軸_XYチェッカー切り離し", "WorkItems": [ "1. チェッカー電源㉖をOFFにする", "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す" ], "WorkPoints": [ "フロント側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し1", "切り離し2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "Y軸 ①", "Y軸 ②", "OFF", "ON", "COM 2", "X5K506", "外す", "外す", "ケーブルカバー㉗", "X5K502", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "取外確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_測定準備", "WorkItems": [ "1. XYユニットチェッカーケーブルを本体エンコーダと繋ぐ", "3. 機種選択、シリアルポートを確認する", "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『X AxisC』をクリックし、調整用ソフトを立ち上げる" ], "WorkPoints": [ "フロント側", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを繋ぐ", "接続" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "COM 1", "接続", "ケーブルカバー㉗", "X5K501", "X軸" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "フロント側_X軸_測定準備", "WorkItems": [ "1. XYユニットチェッカーケーブルを本体エンコーダと繋ぐ", "3. 機種選択、シリアルポートを確認する", "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『X AxisC』をクリックし、調整用ソフトを立ち上げる" ], "WorkPoints": [ "フロント側", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを繋ぐ", "接続" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "COM 1", "接続", "ケーブルカバー㉗", "X5K501", "X軸" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_信号Monitor1", "WorkItems": [ "1. チェッカー電源㉖をONにする", "4. 『信号Monitor』をクリックする", "3. X軸を左側メカストッパーまで移動する", "2. 『起動』をクリックすると通信確認OKと表示され画面が切り替わる" ], "WorkPoints": [ "通信エラ-の場合はケーブル繋ぎ、チェッカー電源(ON)を確認する", "画面表示で自動ON" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "信号Monitor" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_信号Monitor2", "WorkItems": [ "3. 『終了』を押す", "1. X軸をフルストローク往復させ測定する(左側メカストッパー~右側メカストッパーまでを往復)", "2. ScaleA、B、Cのmax値の中で最も高い数値の位置へX軸を移動する" ], "WorkPoints": [ "フロント側", "X軸を移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "メーター", "メーター、及びメーター値を見ながらmax値の位置まで移動", "max 値", "メーター値" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_信号調整START", "WorkItems": [ "1. 『信号調整Start』をクリックする", "2. 『開始』をクリックする", "3. Loopカウンターが動き出したら、X軸を右側に動かす", "4. 【信号を確認します】が表示されたら、X軸を左側に戻す" ], "WorkPoints": [ "フロント側", "フロント側", "X軸は50mm/sec以下で60mm以上移動させる事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号調整Start" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_Gain設定確認", "WorkItems": [ "1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する", "2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る", "3. X軸を左側メカストッパーまで移動する" ], "WorkPoints": [ "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す", "OKを確認" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "Gain設定確認", "■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_信号Monitor3", "WorkItems": [ "3. 『終了』を押す", "1. 『信号Monitor』をクリックする", "4. X軸を左側メカストッパーまで移動する", "2. X軸をフルストローク往復させ測定する(左側メカストッパー~右側メカストッパーまでを往復)" ], "WorkPoints": [ "画面表示で自動ON", "フロント側", "OKを確認", "■信号強度規格_min:40以上/max:80以下", "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "信号Monitor", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "OK表示である事max値:各80以下min値:各40以上", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_原点プリセット", "WorkItems": [ "2. 『原点プリセット』をクリックする", "5. 『終了』をクリックする", "3. 『F-X』をクリックする", "4. 原点プリセット値【 8.0000 】が表示されたら『SET』をクリックする", "1. X軸を左側メカストッパーに当付ける" ], "WorkPoints": [ "8.0000が表示" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 X軸原点調整" ], "WorkTypes": [], "Words": [ "原点位置", "原点プリセット", "WEPJ-G002-C02" ] }
{ "QualityItem": "原点プリセット値設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "X軸プリセット値:8.0㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_ストローク確認", "WorkItems": [ "2. 『位置データ確認』をクリックする", "3. X軸を左側メカストッパーに当付けた状態で位置データを検査表に記入", "1. X軸を左側メカストッパーに当付ける", "4. X軸を右側メカストッパーに当付けた状態で位置データを検査表に記入し、『終了』をクリックする" ], "WorkPoints": [ "■(-)ストローク規格値 7.8mm~8.2mm", "■(+)ストローク規格値 -497mm~-498mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,14 X軸ストローク確認", "検査表①:No,14 X軸ストローク確認" ], "WorkTypes": [], "Words": [ "(-)側ストローク位置", "(+)側ストローク位置", "(-) 側ストローク欄に記入", "位置データ確認", "(+) 側ストローク欄に記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値X軸:7.8~8.2㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_ストローク確認", "WorkItems": [ "2. 『位置データ確認』をクリックする", "3. X軸を左側メカストッパーに当付けた状態で位置データを検査表に記入", "1. X軸を左側メカストッパーに当付ける", "4. X軸を右側メカストッパーに当付けた状態で位置データを検査表に記入し、『終了』をクリックする" ], "WorkPoints": [ "■(-)ストローク規格値 7.8mm~8.2mm", "■(+)ストローク規格値 -497mm~-498mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,14 X軸ストローク確認", "検査表①:No,14 X軸ストローク確認" ], "WorkTypes": [], "Words": [ "(-)側ストローク位置", "(+)側ストローク位置", "(-) 側ストローク欄に記入", "位置データ確認", "(+) 側ストローク欄に記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値X軸:-497~-498㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_エラー履歴クリア", "WorkItems": [ "2. 『クリア』をクリックする", "3. 完了ランプ点灯を確認し、『終了』をクリックする", "4. 『終了』をクリックし『×』をクリックする", "1. 『エラー履歴クリア』をクリックする" ], "WorkPoints": [ "完了ランプ点灯" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "エラー履歴クリア" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "フロント側_X軸_XYチェッカー切り離し", "WorkItems": [ "1. チェッカー電源㉖をOFFにする", "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す" ], "WorkPoints": [ "フロント側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "COM 1", "外す", "ケーブルカバー㉗", "X5K501", "OFF", "ON", "X軸" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "フロント側_X軸_XYチェッカー切り離し", "WorkItems": [ "1. チェッカー電源㉖をOFFにする", "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す" ], "WorkPoints": [ "フロント側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "COM 1", "外す", "ケーブルカバー㉗", "X5K501", "OFF", "ON", "X軸" ] }
{ "QualityItem": "取外確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①_測定準備", "WorkItems": [ "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『Y AxisC』をクリックし、調整用ソフトを立ち上げる", "3. 機種選択、Y軸①設定のシリアルポートとY軸②設定のシリアルポートを確認する", "1. XYユニットチェッカーケーブルを本体エンコーダと接続する" ], "WorkPoints": [ "リア側", "接続1", "接続2", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "Y軸 ①", "Y軸 ②", "COM 2", "X5K508", "接続", "接続", "接続", "接続", "ケーブルカバー㉗", "X5K504", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "リア側_Y軸①_測定準備", "WorkItems": [ "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『Y AxisC』をクリックし、調整用ソフトを立ち上げる", "3. 機種選択、Y軸①設定のシリアルポートとY軸②設定のシリアルポートを確認する", "1. XYユニットチェッカーケーブルを本体エンコーダと接続する" ], "WorkPoints": [ "リア側", "接続1", "接続2", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "Y軸 ①", "Y軸 ②", "COM 2", "X5K508", "接続", "接続", "接続", "接続", "ケーブルカバー㉗", "X5K504", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①_信号Monitor1", "WorkItems": [ "1. チェッカー電源㉖をONにする", "2. 『起動』をクリックすると通信確認OKと表示され画面が切り替わる", "4. 『信号Monitor』をクリックする", "3. Xビームをフロント側メカストッパーまで移動する" ], "WorkPoints": [ "通信エラ-の場合はケーブル繋ぎ、チェッカー電源(ON)を確認する", "画面表示で自動ON" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "信号Monitor" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①_信号Monitor2", "WorkItems": [ "3. 『終了』を押す", "2. ScaleA、B、Cのmax値の中で最も高い数値の位置へXビームを移動する", "1. Xビームをフルストローク往復させ測定する(リア側メカストッパー~フロント側メカストッパーまでを往復)" ], "WorkPoints": [ "Xビームを移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事", "リア側" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "メーター", "メーター、及びメーター値を見ながらmax値の位置まで移動", "max 値", "メーター値" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①_信号調整START", "WorkItems": [ "1. 『信号調整Start』をクリックする", "2. 『開始』をクリックする", "3. Loopカウンターが動き出したら、Xビームをリア側に動かす", "4. 【信号を確認します】が表示されたら、Xビームをフロント側に戻す" ], "WorkPoints": [ "リア側", "リア側", "Xビームは50mm/sec以下で60mm以上移動させる事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号調整Start" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①_Gain設定確認", "WorkItems": [ "1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する", "2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る", "3. Xビームをリア側メカストッパーまで移動する" ], "WorkPoints": [ "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す", "OKを確認" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "Gain設定確認", "■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①_信号Monitor3", "WorkItems": [ "3. 『終了』を押す", "1. 『信号Monitor』をクリックする", "2. Xビームをフルストローク往復させ測定する(リア側メカストッパー~フロント側メカストッパーまでを往復)", "4. Xビームをリア側メカストッパーまで移動する" ], "WorkPoints": [ "リア側", "画面表示で自動ON", "OKを確認", "■信号強度規格_min:40以上/max:80以下", "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "信号Monitor", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "OK表示である事max値:各40以下min値:各40以上", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸②_信号Monitor1", "WorkItems": [ "4. 『終了』を押す", "1. 『信号Monitor』をクリックする", "2. Xビームをフルストローク往復させ測定する(リア側メカストッパー~フロント側メカストッパーまでを往復)", "3. ScaleA、B、Cのmax値の中で最も高い数値の位置へX軸を移動する" ], "WorkPoints": [ "リア側", "画面表示で自動ON", "Xビームを移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号Monitor", "メーター、及びメーター値を見ながらmax値の位置まで移動", "メーター", "max 値", "メーター値" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸②_信号調整START", "WorkItems": [ "1. 『信号調整Start』をクリックする", "2. 『開始』をクリックする", "3. Loopカウンターが動き出したら、Xビームをフロント側に動かす", "4. 【信号を確認します】が表示されたら、Xビームをリア側に戻す" ], "WorkPoints": [ "リア側", "Xビームは50mm/sec以下で60mm以上移動させる事", "リア側" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号Monitor", "信号調整Start" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸②_Gain設定確認", "WorkItems": [ "1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する", "2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る", "3. Xビームをリア側メカストッパーまで移動する" ], "WorkPoints": [ "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す", "OKを確認" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9", "設定確認", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸②_信号Monitor2", "WorkItems": [ "3. 『終了』を押す", "1. 『信号Monitor』をクリックする", "4. Xビームをリア側メカストッパーまで移動する", "2. Xビームをフルストローク往復させ測定する(リア側メカストッパー~フロント側メカストッパーまでを往復)" ], "WorkPoints": [ "リア側", "画面表示で自動ON", "OKを確認", "■信号強度規格_min:40以上/max:80以下", "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "信号Monitor", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "OK表示である事max値:各80以下min値:各40以上", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①②_原点プリセット", "WorkItems": [ "2. 『原点プリセット』をクリックする", "4. 『終了』をクリックする", "1. Xビームをリア側メカストッパーに当付ける", "3. 『R側SET』をクリックする" ], "WorkPoints": [ "D_Pos1:-18.5㎜", "D_Pos4:179.5㎜", "D_Pos2:18.5㎜", "D_Pos3:-179.5㎜", "D_Pos値は固定値_入力不要", "SET_Pos値は『0.00』_入力不要", "右のOKランプ点灯", "右のOKランプ点灯", "完了ランプ点灯", "-179.5000が表示", "179.5000が表示" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,11 Y軸原点調整" ], "WorkTypes": [], "Words": [ "原点プリセット", "WEPJ-G002-C02" ] }
{ "QualityItem": "原点プリセット値設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Y軸①プリセット値:-179.5㎜Y軸②プリセット値:179.5㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸_偏差測定1", "WorkItems": [ "2. 『偏差測定』をクリックする", "4. 3位置にて『データ取込』をクリックする(PCの『Enterキー』でも可)", "3. Xビームを【 0(ゼロ)】付近に移動する", "1. Xビームをリア側メカストッパーに当付ける" ], "WorkPoints": [ "移動後の誤差は±10㎜以内にする事", "取込み位置を行き過ぎてしまった場合は、再度戻り-方向で必ず行うこと" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "※注意", "-方向で取込むことGOOD", "戻り方向で取込みはNG", "Xビーム", "Xビーム", "偏差測定" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸_偏差測定2", "WorkItems": [ "2. 『終了』をクリックする", "1. Xビームを100㎜毎移動させデータを取込む", "3. Xビームをリア側メカストッパーに当付ける" ], "WorkPoints": [ "100㎜づつ、計10回取込", "100㎜~1000㎜まで取込む", "移動後の誤差は±10㎜以内にする事。【 0(ゼロ) 】付近取込時同様、戻り方向での取込みは禁止", "取込み位置を行き過ぎてしまった場合は、再度戻り-方向で必ず行うこと" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "0mm → データ取込 済 100mm → データ取込 ・ ・ ・ ・ ・ 1000mm → データ取込", "※注意", "-方向で取込むことGOOD", "戻り方向で取込みはNG", "Xビーム", "Xビーム" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸_偏差設定", "WorkItems": [ "1. 『偏差設定』をクリックする", "2. 『R側SET』をクリックする", "3. 『終了』をクリックする" ], "WorkPoints": [ "偏差調整値が表示されている", "右のOKランプ点灯", "右のOKランプ点灯", "完了ランプ点灯", "Y-2:偏差調整後の数値が表示", "Y-1:-179.5000が表示" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "偏差設定" ] }
{ "QualityItem": "原点プリセット値登録確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸_ストローク確認", "WorkItems": [ "2. 『ストローク確認』をクリックする", "1. Xビームをリア側メカストッパーに当付ける", "4. リアXビームをY軸フロントストッパーに押し当て測定する", "3. リアXビームをY軸リアストッパーに押し当て測定する" ], "WorkPoints": [ "■規格値Y軸① -179.7mm~-179.3mmY軸② 179.3mm~179.7mm", "■規格値Y軸① 1117mm~1298.5mmY軸② -1298.5mm~-1117mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,12 Y軸ストローク確認", "検査表①:No,12 Y軸ストローク確認" ], "WorkTypes": [], "Words": [ "奥側ストローク位置", "手前側ストローク位置", "手前側ストローク位置データを記入", "ストローク確認", "奥側ストローク位置データを記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値Y軸①-179.7~-179.3㎜Y軸②179.3~179.7㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸_ストローク確認", "WorkItems": [ "2. 『ストローク確認』をクリックする", "1. Xビームをリア側メカストッパーに当付ける", "4. リアXビームをY軸フロントストッパーに押し当て測定する", "3. リアXビームをY軸リアストッパーに押し当て測定する" ], "WorkPoints": [ "■規格値Y軸① -179.7mm~-179.3mmY軸② 179.3mm~179.7mm", "■規格値Y軸① 1117mm~1298.5mmY軸② -1298.5mm~-1117mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,12 Y軸ストローク確認", "検査表①:No,12 Y軸ストローク確認" ], "WorkTypes": [], "Words": [ "奥側ストローク位置", "手前側ストローク位置", "手前側ストローク位置データを記入", "ストローク確認", "奥側ストローク位置データを記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値Y軸①1117~1298.5㎜Y軸②-1298.5~-1117㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸①②_エラー履歴クリア", "WorkItems": [ "1. 『エラー履歴クリア』クリックする", "2. 『クリア』をクリックする", "3. 完了ランプ点灯を確認し『終了』をクリックする", "4. 『終了』をクリックし『×』をクリックする" ], "WorkPoints": [ "完了ランプ点灯" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "エラー履歴クリア" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_Y軸_XYチェッカー切り離し", "WorkItems": [ "1. チェッカー電源㉖をOFFにする", "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す" ], "WorkPoints": [ "リア側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し1", "切り離し2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "Y軸 ①", "Y軸 ②", "OFF", "ON", "COM 2", "X5K508", "外す", "外す", "ケーブルカバー㉗", "X5K504", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "リア側_Y軸_XYチェッカー切り離し", "WorkItems": [ "1. チェッカー電源㉖をOFFにする", "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す" ], "WorkPoints": [ "リア側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し1", "切り離し2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "Y軸 ①", "Y軸 ②", "OFF", "ON", "COM 2", "X5K508", "外す", "外す", "ケーブルカバー㉗", "X5K504", "COM 1", "ケーブルカバー㉗" ] }
{ "QualityItem": "取外確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_測定準備", "WorkItems": [ "3. 機種選択、シリアルポートを確認する", "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『X AxisC』をクリックし、調整用ソフトを立ち上げる", "1. XYユニットチェッカーケーブルを本体エンコーダと接続する" ], "WorkPoints": [ "リア側", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する", "接続" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "COM 1", "接続", "ケーブルカバー㉗", "X5K503", "X軸" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りの設定になっている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "リア側_X軸_測定準備", "WorkItems": [ "3. 機種選択、シリアルポートを確認する", "2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『X AxisC』をクリックし、調整用ソフトを立ち上げる", "1. XYユニットチェッカーケーブルを本体エンコーダと接続する" ], "WorkPoints": [ "リア側", "チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する", "接続" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "COM 1", "接続", "ケーブルカバー㉗", "X5K503", "X軸" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_信号Monitor1", "WorkItems": [ "1. チェッカー電源㉖をONにする", "4. 『信号Monitor』をクリックする", "3. X軸を左側メカストッパーまで移動する", "2. 『起動』をクリックすると通信確認OKと表示され画面が切り替わる" ], "WorkPoints": [ "通信エラ-の場合はケーブル繋ぎ、チェッカー電源(ON)を確認する", "画面表示で自動ON" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "OFF", "ON", "信号Monitor" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_信号Monitor2", "WorkItems": [ "3. 『終了』を押す", "1. X軸をフルストローク往復させ測定する(左側メカストッパー~右側メカストッパーまでを往復)", "2. ScaleA、B、Cのmax値の中で最も高い数値の位置へX軸を移動する" ], "WorkPoints": [ "リア側", "X軸を移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "メーター", "メーター、及びメーター値を見ながらmax値の位置まで移動", "max 値", "メーター値" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_信号調整START", "WorkItems": [ "1. 『信号調整Start』をクリックする", "2. 『開始』をクリックする", "3. Loopカウンターが動き出したら、X軸を右側に動かす", "4. 【信号を確認します】が表示されたら、X軸を左側に戻す" ], "WorkPoints": [ "リア側", "リア側", "X軸は50mm/sec以下で60mm以上移動させる事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "信号調整Start" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_Gain設定確認", "WorkItems": [ "1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する", "2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る", "3. X軸を左側メカストッパーまで移動する" ], "WorkPoints": [ "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す", "OKを確認" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "Gain設定確認", "■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_信号Monitor3", "WorkItems": [ "3. 『終了』を押す", "1. 『信号Monitor』をクリックする", "4. X軸を左側メカストッパーまで移動する", "2. X軸をフルストローク往復させ測定する(左側メカストッパー~右側メカストッパーまでを往復)" ], "WorkPoints": [ "リア側", "画面表示で自動ON", "OKを確認", "■信号強度規格_min:40以上/max:80以下", "NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,10 XY軸リニアスケール信号調整" ], "WorkTypes": [], "Words": [ "信号Monitor", "WEPJ-G002-C02" ] }
{ "QualityItem": "XY軸リニアスケール信号調整", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "OK表示である事max値:各80以下min値:各40以上", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_原点プリセット", "WorkItems": [ "2. 『原点プリセット』をクリックする", "3. 『R-X』をクリックする", "4. 原点プリセット値【 8.0000 】が表示されたら『SET』をクリックする", "1. X軸を左側メカストッパーに当付ける", "5. 『終了』をクリックする" ], "WorkPoints": [ "8.0000が表示" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,13 X軸原点調整" ], "WorkTypes": [], "Words": [ "原点位置", "原点プリセット", "WEPJ-G002-C02" ] }
{ "QualityItem": "原点プリセット値設定確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "X軸プリセット値:8.0㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_ストローク確認", "WorkItems": [ "2. 『位置データ確認』をクリックする", "3. X軸を左側メカストッパーに当付けた状態で位置データを検査表に記入", "1. X軸を左側メカストッパーに当付ける", "4. X軸を右側メカストッパーに当付けた状態で位置データを検査表に記入し、『終了』をクリックする" ], "WorkPoints": [ "■(-)ストローク規格値 7.8mm~8.2mm", "■(+)ストローク規格値 -497mm~-498mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,14 X軸ストローク確認", "検査表①:No,14 X軸ストローク確認" ], "WorkTypes": [], "Words": [ "(-)側ストローク位置", "(+)側ストローク位置", "(-) 側ストローク欄に記入", "位置データ確認", "(+) 側ストローク欄に記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値X軸:7.8~8.2㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_ストローク確認", "WorkItems": [ "2. 『位置データ確認』をクリックする", "3. X軸を左側メカストッパーに当付けた状態で位置データを検査表に記入", "1. X軸を左側メカストッパーに当付ける", "4. X軸を右側メカストッパーに当付けた状態で位置データを検査表に記入し、『終了』をクリックする" ], "WorkPoints": [ "■(-)ストローク規格値 7.8mm~8.2mm", "■(+)ストローク規格値 -497mm~-498mm" ], "Tolks": [], "InspectionNo": "WEPJ-G002-C02", "InspectionItems": [ "検査表①:No,14 X軸ストローク確認", "検査表①:No,14 X軸ストローク確認" ], "WorkTypes": [], "Words": [ "(-)側ストローク位置", "(+)側ストローク位置", "(-) 側ストローク欄に記入", "位置データ確認", "(+) 側ストローク欄に記入", "WEPJ-G002-C02" ] }
{ "QualityItem": "測定値記録", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "規格値X軸:-497~-498㎜", "Method": "目視", "RecordMethod": "WEPJ-G002-C02", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_エラー履歴クリア", "WorkItems": [ "2. 『クリア』をクリックする", "3. 完了ランプ点灯を確認し、『終了』をクリックする", "4. 『終了』をクリックし『×』をクリックする", "1. 『エラー履歴クリア』をクリックする" ], "WorkPoints": [ "完了ランプ点灯" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "エラー履歴クリア" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示通りに表示されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYユニットチェッカー", "Size": "", "ToolOther": "FM-2224", "WorkName": "リア側_X軸_XYチェッカー切り離し", "WorkItems": [ "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを外す", "1. チェッカー電源㉖をOFFにする" ], "WorkPoints": [ "フロント側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "COM 1", "外す", "ケーブルカバー㉗", "X5K503", "OFF", "ON", "X軸" ] }
{ "QualityItem": "取外確認", "ToolManageNo": "FM-2224", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "全て取外してある事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "XYチェッカーコネクターカバー", "Size": "", "ToolOther": "FM-3979", "WorkName": "リア側_X軸_XYチェッカー切り離し", "WorkItems": [ "2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを外す", "1. チェッカー電源㉖をOFFにする" ], "WorkPoints": [ "フロント側", "チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す", "切り離し" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "COM 1", "外す", "ケーブルカバー㉗", "X5K503", "OFF", "ON", "X軸" ] }
{ "QualityItem": "取外確認", "ToolManageNo": "FM-3979", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "全て取外してある事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け準備", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "1.下記リストの順番でケーブルを準備する" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け1", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "爪の反対側にタグが見えるようにする", "コネクタの向きに注意すること", "マーキングタイの端をケーブル根元に合わせる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "X2BK506", "X2AK503", "X2AK503", "X2BK506" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け2", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "マーキングタイの端をケーブル根元に合わせる", "矢印側にタグが見えるようにする", "マーキングタイの真ん中をコネクタ根元に合わせる", "矢印側にタグが見えるようにする", "コネクタの向きに注意すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "USB1(Type_A)", "USBC101(Type_B)", "横図" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け3", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "爪側にタグが見えるようにする", "コネクタの向きに注意すること", "爪の反対側にタグが見えるようにする", "マーキングタイの端をケーブル根元に合わせる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "X2AK501", "3K302", "3K302", "X2AK501" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け4", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "爪側にタグが見えるようにする", "爪の反対側にタグが見えるようにする", "マーキングタイの端をケーブル根元に合わせる", "コネクタの向きに注意すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "X2BK508", "4K302", "4K302", "X2BK508" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け5", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "コネクタの向きに注意すること", "マーキングタイの端をケーブル根元に合わせる", "爪側にタグが見えるようにする" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "LAN1_K301", "CNLN", "CNLN" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け6", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "コネクタの向きに注意すること", "爪の反対側にタグが見えるようにする", "マーキングタイの端をケーブル根元に合わせる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "X2BK503", "X2AK504", "X2AK504", "X2BK503" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け7", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "マーキングタイの端をケーブル根元に合わせる", "KAMERAシールの無い側にタグが見えるようにする", "ケーブル表側からタグが見えるようにする", "コネクタの向きに注意すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "2A12", "1K303" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マーキングタイ取付け8", "WorkItems": [ "1. CABLE にLABEL を取付ける" ], "WorkPoints": [ "爪の反対側にタグが見えるようにする", "マーキングタイの端をケーブル根元に合わせる", "コネクタの向きに注意すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "X2BK504", "X2AK508", "X2AK508", "X2BK504" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付け出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null