{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "警告ラベル貼付け確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "■1. 警告ラベル貼付けチェックリストに基づき、貼付けられているか確認する", "検査表①:9.警告ラベル貼付け確認", "WEPJ-G002-A07" ] }
{ "QualityItem": "貼付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに貼付け出来ている事", "Method": "目視", "RecordMethod": "WEPJ-G002-A07", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "300cN・m", "WorkName": "前面黒カバー取付け", "WorkItems": [ "1. ①をSCREW で取付ける" ], "WorkPoints": [], "Tolks": [ "締付トルク 300cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "FRONT" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "300cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "300cN・m", "WorkName": "後面黒カバー取付け", "WorkItems": [ "1. ①COVER をSCREW で取付ける" ], "WorkPoints": [ "トレイ仕様時は①のグロメット無し", "グロメット", "グロメット" ], "Tolks": [ "締付トルク 300cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "REAR" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "300cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.3", "ToolOther": "3.5N・m", "WorkName": "前面白カバー取付け", "WorkItems": [ "1. ①②をSCREW で取付ける" ], "WorkPoints": [ "①②を斜めから本体側のシャフトに引っ掛ける", "下側をSCREW で取付ける" ], "Tolks": [ "締付トルク 3.5N・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "FRONT" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.5N・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.3", "ToolOther": "3.5N・m", "WorkName": "後面白カバー取付け", "WorkItems": [ "1. ①②をSCREW で取付ける" ], "WorkPoints": [ "①②を斜めから本体側のシャフトに引っ掛ける", "下側をSCREW で取付ける" ], "Tolks": [ "締付トルク 3.5N・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "REAR" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.5N・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ソフトスイッチ設定", "WorkItems": [ "1. ①『サービスエンジニア』を押す", "2. ②『デバックモード』を押す", "3. ③『ソフトスイッチ』を押す", "4. ④精度検証実証選択を『ON』にする", "5. ⑤『ホーム』を押す", "6. ⑥『はい』を押す" ], "WorkPoints": [ "電源OFF⇒ON時、再度精度検証を実施する場合は再設定をする事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マシン仕様確認", "WorkItems": [ "1. 仕様書と実機が同じである事を確認し、検査表に記載する" ], "WorkPoints": [ "□にレを入れる", "PLラベルの言語電源電圧シグナルタワー搬送高さ基板流れ方向塗装色本体構成オプション仕様" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:仕様確認" ], "WorkTypes": [], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "仕様確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "-" ] }
information_extraction
0
null
{ "ToolName": "コンベックス", "Size": "", "ToolOther": "", "WorkName": "マシンレベル確認", "WorkItems": [ "1. 水準器設置箇所をウエスにてふきあげる", "2. マシンのレベルを調整する" ], "WorkPoints": [ "グリース・異物無き事", "規格値:0.06㎜/m", "目標値は2目盛とする", "アジャストボルトA・B・C・D・E・Fの浮きが無い事", "搬送レール高さ910㎜に調整する", "アジャストボルト" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "◆作業者安全作業" ], "Words": [ "◆作業者安全作業" ] }
{ "QualityItem": "高さ確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示寸法±10㎜", "Method": "コンベックス", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "作業者安全工程" ] }
information_extraction
0
null
{ "ToolName": "水準器", "Size": "", "ToolOther": "0.02㎜/m", "WorkName": "マシンレベル確認", "WorkItems": [ "1. 水準器設置箇所をウエスにてふきあげる", "2. マシンのレベルを調整する" ], "WorkPoints": [ "グリース・異物無き事", "規格値:0.06㎜/m", "目標値は2目盛とする", "アジャストボルトA・B・C・D・E・Fの浮きが無い事", "搬送レール高さ910㎜に調整する", "アジャストボルト" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [], "WorkTypes": [ "◆作業者安全作業" ], "Words": [ "◆作業者安全作業", "WEAV-G002-A05" ] }
{ "QualityItem": "水準確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "0.06㎜/m以下", "Method": "水準器", "RecordMethod": "WEAV-G002-A05", "Other": "グリースLCG100", "ProcessNames": [ "作業者安全工程" ] }
information_extraction
0
null
{ "ToolName": "マルチテスター", "Size": "", "ToolOther": "", "WorkName": "電源電圧測定", "WorkItems": [ "7. 外したカバーを取付ける" ], "WorkPoints": [ "マシンの主電源をOFFにした状態で接続の事", "計測器No.を記入する事", "赤端子", "黒端子" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:2.電源電圧測定" ], "WorkTypes": [ "■安全作業" ], "Words": [ "■安全作業", "WEAV-G002-A05" ] }
{ "QualityItem": "電圧測定", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "200V±10V", "Method": "マルチテスター", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エアー接続確認1", "WorkItems": [ "1. マシン後側のカバーを外す", "2. マシンにエアーホースを接続する", "3. 工場側のエアーホースを接続する", "4. メインエアー圧を確認する", "5. 外したカバーを取付ける" ], "WorkPoints": [ "規格値:0.5~0.55MPa", "規格値外の場合は、矢印部を回して調整・ロックする", "ロック", "前工程で接続済であれば接続作業不要" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:3.エアー接続確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "0.5~0.505MPa", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エアー接続確認2", "WorkItems": [ "1. ①マシン⇒②調整⇒③ヘッド⇒④真空出力確認を押す", "2. を押しながら⑤破壊を押す", "3. を押しながら⑥真空ポンプを押す", "4. を押しながら⑦破壊⑧清掃ブローを押す", "5. オプション圧を確認する" ], "WorkPoints": [ "規格値:8kPa~12kPa", "規格値:-100kPa~-87kPa", "規格値:0.13MPa~0.14MPa", "各ゲージ位置", "オプション圧", "清掃ブロー圧", "真空ポンプ圧", "規格値:0.4MPa", "真空破壊圧" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:3.エアー接続確認", "検査表①:3.エアー接続確認", "検査表①:3.エアー接続確認", "検査表①:3.エアー接続確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "8~12kPa0.13~0.14MPa0.4MPa", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "外観確認", "WorkItems": [ "1. マシンに汚れ、傷、歪み等無き事確認する" ], "WorkPoints": [ "タッチパネル(F・R)", "側面上白カバー部(L・R)", "下白カバー(F)", "下白カバー(R)", "操作パネル(F・R)", "開閉カバー(F・R)", "側面下黒カバー(R・L)", "天井カバー" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:4.外観検査" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "外観確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ラインSWBOX", "Size": "", "ToolOther": "FM-2460", "WorkName": "安全動作確認1", "WorkItems": [ "1. 本体に㉖を接続する", "2. SW BOXを設定する", "■3. 開口部センサ確認", "■4. 隣接装置入力確認", "■5. 非常停止確認", "■6. サーボSW機能確認" ], "WorkPoints": [ "原点復帰動作中に検査SWBOXのR_OPIN SWをOFFした時マシンが停止する事右側搬送部開口サンサーを遮光した時に検査用SW-BOX R_OPOT:消灯エラーメッセジ:『搬送開口部検出(右側)』", "原点復帰動作中に検査SWBOXのL_OPIN SWをOFFした時マシンが停止する事左側搬送部開口サンサーを遮光した時に検査用SW-BOX L_OPOT:消灯エラーメッセジ:『搬送開口部検出(左側)』", "L_OPIN:ON、R_OPIN:ONDCIN:CNEXL、その他 SW OFF", "右→左仕様時逆に接続する", "右→左仕様時逆に接続する", "SW-BOXのR.STIN#0をOFFして、原点復帰動作中にSW-BOXのR.STIN#0をONした時、マシンが停止する事エラーメッセジ:『安全装置検出(後工程)』", "SW-BOXのL.STIN#0をOFFして、原点復帰動作中にSW-BOXのL.STIN#0をONした時、マシンが停止する事エラーメッセジ:『安全装置検出(前工程)』", "原点復帰動作中に非常停止SWを押すと、マシンが停止する事エラーメッセジ:『非常停止スイッチオン』", "原点復帰動作中に前後各々でサーボSWをOFFさせると、マシンが停止する事を確認するエラーメッセージ:『サーボスイッチ オフ』" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "-XS接続", "-XP接続", "CNEXR接続", "CNDUS接続", "CNEXL接続", "CNDUP接続", "WEAV-G002-A05" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2460", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ラインSWBOX", "Size": "", "ToolOther": "FM-2460", "WorkName": "安全動作確認2", "WorkItems": [ "■1. カバーオープン確認", "■2. 幅寄せインターロック確認", "■3. 幅寄せ中、非常停止SWにて停止確認", "■4. フィーダカバー確認", "■5. 部品廃棄BOX確認", "■6. テープ浮きインターロック確認", "■7. 交換台車確認" ], "WorkPoints": [ "原点復帰動作中に前後各々でカバーを開けると、マシンが停止する事を確認するエラーメッセージ:『カバーオープン(*)』 (該当安全スイッチ箇所と*表示が一致する事)", "下受けプレートにピンを立て、幅寄せ動作を行いピン検出にて幅寄せ動作が停止する事を確認するエラーメッセージ:『下受けピン干渉エラー(レーン*)』 (該当レーンと*表示が一致する事)", "幅寄せ動作中に前後各々で非常停止SWを押すと、マシンが停止する事を確認するエラーメッセージ:『非常停止スイッチオン』", "前後各々でフィーダカバーを開いた状態で、マシンを原点復帰動作させた場合にマシンが動作し無い事エラーメッセージ:『フィーダカバー無し』", "前後各々で部品廃棄BOXを取り外した状態で、マシンを原点復帰動作させた場合にマシンが動作し無い事エラーメッセージ:『排出BOX無し』", "前後各々でテープ浮きセンサを遮光した状態で、マシンを原点復帰動作させた場合にましが動作し無い事エラーメッセージ:『テープカバー検出4』、『テープカバー検出3』、『テープカバー検出2』、『テープカバー検出1』", "前後各々で交換台車を取り外した状態で、マシンを原点復帰動作させた場合にマシンが動作し無い事エラーメッセージ:『供給部接続エラー』", "※トレイストッカー仕様の場合このページの内容プラスSD-EJM9D05-201を参照" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認", "検査表①:6.安全動作確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2460", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全動作確認3(トレイストッカー仕様時)", "WorkItems": [ "■1. 非常停止スイッチ確認", "■2. サーボスイッチOFFにて停止確認", "■3. トレイストッカー未接続確認", "■4. トレイストッカーのメンテンナンスカバーオープン時の確認", "■5. 非常停止スイッチ停止確認", "■6. マガジンドアAオープンで動作確認", "■7. . マガジンドアBオープンで動作確認", "■8. . メンテンナンスカバーオープン時の確認" ], "WorkPoints": [ "原点復帰動作中に設備非常停止スイッチにて、トレイフィーダ部X11が停止すること ※トレイストッカーは、停止しない", "原点復帰動作中にサーボスイッチOFFにて、トレイフィーダー部X11が動作しないこと ※トレイストッカーは、停止しない", "トレイストッカーが接続未状態のときトレイフィーダー部X11が動作しないこと", "トレイストッカーのメンテンナンスカバーをオープンにした時、X11が動作しないことを確認 ※トレイストッカーも動作しない", "トレイストッカー非常停止スイッチにて、トレイストッカーX20が停止すること(原点復帰で確認) ※トレイフィーダX11と NPM-WXは動作する", "トレイストッカーマガジンドアA オープンでトレイストッカーX20が動作しないこと(原点復帰で確認) ※トレイフィーダX11と NPM-WXは動作する", "トレイストッカーマガジンドアB オープンでトレイストッカーX20が動作しないこと(原点復帰で確認) ※トレイフィーダX11と NPM-WXは動作する", "メンテナンスカバーオープンでトレイストッカーX20が動作しないこと※トレイフィーダX11と NPM-WXも動作しない※マシン画面の表示に【パワーON不可】と表示されること" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:.安全動作確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:7-2.安全動作確認", "検査表①:7-2.安全動作確認", "検査表①:7-2.安全動作確認", "検査表①:7-2.安全動作確認", "検査表①:7-2.安全動作確認", "検査表①:7-2.安全動作確認", "トレイフィーダ:X11", "トレイストッカー:X20", "検査表①:7-2.安全動作確認", "WEAV-G002-A05" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション", "WorkItems": [ "1. キャリブレーションSTEP1を実施する", "2. キャリブレーションSTEP2を実施する", "3. キャリブレーションSTEP3を実施する", "4. キャリブレーションSTEP4を実施する" ], "WorkPoints": [ "SD-EJM9D04-301~305参照", "SD-EJM9D04-306~316参照", "SD-EJM9D04-317~325参照", "SD-EJM9D04-326~329参照" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:8.キャリブレーションSTEP1" ], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:9.キャリブレーションSTEP2", "検査表①:10.キャリブレーションSTEP3", "検査表①:11.キャリブレーションSTEP4", "WEAV-G002-A05" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(チップ)1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『オフセット反映』を押す", "4. ④実装する部品を選択する", "6. ⑥使用するノズルを選択する", "7. ⑦『読込』を押す", "8. ⑧データが生成されたか確認する", "5. ⑤実装するステージを選択する" ], "WorkPoints": [ "データロード", "レーン2生成時はここを選択する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(チップ)2", "WorkItems": [ "1. ①『段取り』を押す", "2. ②『部材準備』を押す", "3. ③『TBL1』を押す", "4. ④『表示切替』を押す", "5. ⑤チェンジャユニットを取外す", "6. ⑥指定されたノズルを指定位置にセットする", "7. ⑦『TBL2』を押す", "9. ⑨チェンジャユニットを取外す", "10. ⑩指定されたノズルを指定位置にセットする", "8. ⑧『表示切替』を押す" ], "WorkPoints": [ "セット後チェンジャーを戻す", "⑩指定ノズル・位置", "ノズルセット", "⑥指定ノズル・位置", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す", "セット後チェンジャーを戻す", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "※画像は全て16N+16Nのものです" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(チップ)3", "WorkItems": [ "1. ①『段取り替え』を押す", "2. ②『TBL1』を押す", "3. ③『フィーダ』を押す", "4. ④指定された位置にテープフィーダをセットする", "5. ⑤『TBL2』へ切り替え、手順3~4を実施する" ], "WorkPoints": [ "フィーダセット" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "自己計測(チップ)4", "WorkItems": [ "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "6. 自動運転終了後、⑥ ホーム』を押す", "8. 画面上の⑧『基板抜き取り』を押す", "9. 『はい』を押す", "7. 操作パネルの を押しながら⑦『はい』を押す", "3. 操作パネルの を押しながら③『はい』を押す", "4. 操作パネルの を押しながら④『はい』を押す", "5. 操作パネルの を押しながら⑤『はい』を押す" ], "WorkPoints": [ "精度検証1/2", "コンベア上の基板情報が全てクリアされ継続生産が出来なくなります。よろしいですか?", "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "自己診断が開始され全て『OK』になったら自動運転~自動認識が開始する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(チップ)5", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "6. 角度毎オフセットが表示されるので確認後 ⑥『検証データ反映』を押す", "3. ③『精度検証結果』を押す", "7. 「チップの値を微微小に反映しますか?よろしいですか?」  と表示されるので、⑦『はい』を押す", "8. 「第一レーンの値を他レーンに反映しますか」 と表示されるので、⑧『はい』を押す", "9. 「データの保存を行います。よろしいですか?」  と表示されるので、⑨『はい』を押す", "10. レーン2も同様に検証データ反映を行う", "5. ⑤『角度毎オフセット』を押す", "4. ④『TBL1』を押す" ], "WorkPoints": [ "精度検証2/2", "『検証データ反映』を実行する事によりオフセットが自動計算される", "1005JIGチップ実装時のみ表示", "既に0402Rでの精度検証を終えている場合は『いいえ』を押す", "既にレーン2での精度検証を終えている場合は『いいえ』を押す", "デュアルコンベア仕様時のみ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "精度検証・実装精度確認(チップ)", "WorkItems": [ "9. 操作パネルの を押しながら⑨『はい』を押す", "6. 操作パネルの を押しながら⑥『いいえ』を押す", "5. 操作パネルの を押しながら④『第一』を押す", "1. 自己計測1~3までの作業を実施する", "4. 操作パネルの を押しながら④『はい』を押す", "3. ③操作パネルの を押しながら を押し生産を開始する", "2. ②『生産』を押す", "7. 操作パネルの を押しながら⑦『はい』を押す", "8. 自動運転終了後、⑧『ホーム』を押す", "10. ⑩『メンテナンス』を押す", "11. ⑪『データ生成』を押す", "12. ⑫『検証結果』を押す", "13. ⑬実装後の精度を確認する", "14. Nikon計測器にて、実装した基板の装着精度を確認する", "15. レーン2も同様に装着精度を確認する" ], "WorkPoints": [ "精度検証データ生成の①『精度検証』を選択しデータ生成を行う事", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "デュアルコンベア仕様時のみ", "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "XY目標値:±0.025㎜ CpK:1.0以上" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:14.装着精度確認(チップ部品)", "検査表②:CR6.装着精度確認(チップ部品)", "検査表②:CR6.装着精度確認(チップ部品)", "検査表①:14.装着精度確認(チップ部品)" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "-", "Method": "-", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "2次元測定器", "Size": "", "ToolOther": "", "WorkName": "精度検証・実装精度確認(チップ)", "WorkItems": [ "9. 操作パネルの を押しながら⑨『はい』を押す", "6. 操作パネルの を押しながら⑥『いいえ』を押す", "5. 操作パネルの を押しながら④『第一』を押す", "1. 自己計測1~3までの作業を実施する", "4. 操作パネルの を押しながら④『はい』を押す", "3. ③操作パネルの を押しながら を押し生産を開始する", "2. ②『生産』を押す", "7. 操作パネルの を押しながら⑦『はい』を押す", "8. 自動運転終了後、⑧『ホーム』を押す", "10. ⑩『メンテナンス』を押す", "11. ⑪『データ生成』を押す", "12. ⑫『検証結果』を押す", "13. ⑬実装後の精度を確認する", "14. Nikon計測器にて、実装した基板の装着精度を確認する", "15. レーン2も同様に装着精度を確認する" ], "WorkPoints": [ "精度検証データ生成の①『精度検証』を選択しデータ生成を行う事", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "デュアルコンベア仕様時のみ", "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "XY目標値:±0.025㎜ CpK:1.0以上" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:14.装着精度確認(チップ部品)", "検査表②:CR6.装着精度確認(チップ部品)", "検査表②:CR6.装着精度確認(チップ部品)", "検査表①:14.装着精度確認(チップ部品)", "WEAV-G002-A05WEAV-G002-A03" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "1回/3年", "ToolRecord": "校正成績書", "StdVal": "XY=±0.025㎜θ=±5CpK≧1.0", "Method": "2次元測定器", "RecordMethod": "WEAV-G002-A05WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "精度検証_軽量16Nヘッド0201C装着対応", "WorkItems": [ "9. 操作パネルの を押しながら⑩『はい』を押す", "6. 操作パネルの を押しながら⑦『いいえ』を押す", "5. 操作パネルの を押しながら⑥『第一』を押す", "1. 自己計測1~3までの作業を実施する", "2. ③『生産』を押す", "3. ④操作パネルの を押しながら を押し生産を 開始する", "4. 操作パネルの を押しながら⑤『はい』を押す", "7. 操作パネルの を押しながら⑧『いいえ』を押す", "8. 自動運転終了後、⑨『ホーム』を押す", "10. Nikon計測器にて、実装した基板の装着精度を確認する", "11. レーン2も同様に装着精度を確認する" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "精度検証データ生成の①『精度検証』・②『0201』を選択しデータ生成を行う事", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "デュアルコンベア仕様時のみ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:14.装着精度確認(オプション)", "検査表①:14.装着精度確認(オプション)" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "-", "Method": "-", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "2次元測定器", "Size": "", "ToolOther": "", "WorkName": "精度検証_軽量16Nヘッド0201C装着対応", "WorkItems": [ "9. 操作パネルの を押しながら⑩『はい』を押す", "6. 操作パネルの を押しながら⑦『いいえ』を押す", "5. 操作パネルの を押しながら⑥『第一』を押す", "1. 自己計測1~3までの作業を実施する", "2. ③『生産』を押す", "3. ④操作パネルの を押しながら を押し生産を 開始する", "4. 操作パネルの を押しながら⑤『はい』を押す", "7. 操作パネルの を押しながら⑧『いいえ』を押す", "8. 自動運転終了後、⑨『ホーム』を押す", "10. Nikon計測器にて、実装した基板の装着精度を確認する", "11. レーン2も同様に装着精度を確認する" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "精度検証データ生成の①『精度検証』・②『0201』を選択しデータ生成を行う事", "規格値:XY=±0.025mm CpK≧1.0 :θ=±5° CpK≧1.0", "デュアルコンベア仕様時のみ" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:14.装着精度確認(オプション)", "検査表①:14.装着精度確認(オプション)" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "1回/3年", "ToolRecord": "校正成績書", "StdVal": "XY=±0.025㎜θ=±5CpK≧1.0", "Method": "2次元測定器", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "【高精度モード】自己計測(チップ)1", "WorkItems": [ "2. ②『精度検証』を押す", "3. ③『オフセット反映』を押す", "4. ④実装する部品を選択する", "1. オプションライセンスが登録されている事を確認する", "1. ①『メンテナンス』を押す", "5. ⑤使用するノズルを選択する", "6. ⑥『詳細』を押す", "7. ⑦高精度モードの『ON』を押す", "8. ⑧『戻る』を押す", "9. ⑨『読込』を押す", "10. ⑩データが生成されたか確認する", "11. 自己計測2~5までの作業を実施する" ], "WorkPoints": [ "標準の検証データ反映・精度確認(1005JIG・0402R)終了後実施の事", "ライセンス確認", "データロード", "レーン2生成時はここを選択する", "SD-EJM8D05-011~014" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通りに設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "オプション", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "【高精度モード】実装精度確認(チップ)", "WorkItems": [ "6. 操作パネルの を押しながら⑦『いいえ』を押す", "1. 自己計測1~3までの作業を実施する", "4. 操作パネルの を押しながら⑤『はい』を押す", "2. ③『生産』を押す", "3. ④操作パネルの を押しながら を押し生産を開始する", "5. 操作パネルの を押しながら⑥『第一』を押す", "8. 自動運転終了後、⑨『ホーム』を押す", "9. 操作パネルの を押しながら⑩『はい』を押す", "10. ⑪『メンテナンス』を押す", "11. ⑫『データ生成』を押す", "12. ⑬『検証結果』を押す", "13. ⑭実装後の精度を確認する", "14. Nikon計測器にて、実装した基板の装着精度を確認する", "15. 作業が終了したら、 を押しながら⑮『取外し』でノズルを取り外す", "7. 操作パネルの を押しながら⑧『はい』を押す" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "XY目標値:±0.015㎜ CpK:1.0以上", "規格値:XY=±0.015mm CpK≧1.0 :θ=±5° CpK≧1.0", "データ生成時は①『精度検証』・②『1005 or 0402』『高精度モード:ON』を選択しデータ生成を行う事", "SD-EJM8D08-066・011~012" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:15.装着精度確認(チップ部品)高精度モード" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "-", "Method": "-", "RecordMethod": "-", "Other": "オプション", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "2次元測定器", "Size": "", "ToolOther": "", "WorkName": "【高精度モード】実装精度確認(チップ)", "WorkItems": [ "6. 操作パネルの を押しながら⑦『いいえ』を押す", "1. 自己計測1~3までの作業を実施する", "4. 操作パネルの を押しながら⑤『はい』を押す", "2. ③『生産』を押す", "3. ④操作パネルの を押しながら を押し生産を開始する", "5. 操作パネルの を押しながら⑥『第一』を押す", "8. 自動運転終了後、⑨『ホーム』を押す", "9. 操作パネルの を押しながら⑩『はい』を押す", "10. ⑪『メンテナンス』を押す", "11. ⑫『データ生成』を押す", "12. ⑬『検証結果』を押す", "13. ⑭実装後の精度を確認する", "14. Nikon計測器にて、実装した基板の装着精度を確認する", "15. 作業が終了したら、 を押しながら⑮『取外し』でノズルを取り外す", "7. 操作パネルの を押しながら⑧『はい』を押す" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "XY目標値:±0.015㎜ CpK:1.0以上", "規格値:XY=±0.015mm CpK≧1.0 :θ=±5° CpK≧1.0", "データ生成時は①『精度検証』・②『1005 or 0402』『高精度モード:ON』を選択しデータ生成を行う事", "SD-EJM8D08-066・011~012" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:15.装着精度確認(チップ部品)高精度モード" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "1回/3年", "ToolRecord": "校正成績書", "StdVal": "XY:±0.015㎜θ:±5°CpK≧1.0", "Method": "2次元測定器", "RecordMethod": "WEAV-G002-A05", "Other": "オプション", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "【高精度モード】精度検証_軽量16Nヘッド0201C装着対応", "WorkItems": [ "1. 自己計測1~3までの作業を実施する", "3. ④操作パネルの を押しながら を押し生産を開始する", "2. ③『生産』を押す", "4. 操作パネルの を押しながら⑤『はい』を押す", "5. 操作パネルの を押しながら⑥『第一』を押す", "6. 操作パネルの を押しながら⑦『いいえ』を押す", "15. 作業が終了したら、 を押しながら⑮『取外し』でノズルを取り外す", "8. 自動運転終了後、⑨『ホーム』を押す", "9. 操作パネルの を押しながら⑩『はい』を押す", "14. Nikon計測器にて、実装した基板の装着精度を確認する", "7. 操作パネルの を押しながら⑧『はい』を押す", "10. ⑪『メンテナンス』を押す", "11. ⑫『データ生成』を押す", "12. ⑬『検証結果』を押す", "13. ⑭実装後の精度を確認する" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "データ生成時は①『精度検証』・②『0201』・『高精度モード:ON』を選択しデータ生成を行う事", "SD-EJM8D05-066・011~012", "規格値:XY=±0.015mm CpK≧1.0 :θ=±5° CpK≧1.0" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:16.装着精度確認(オプション)" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "-", "Method": "-", "RecordMethod": "-", "Other": "オプション", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "2次元測定器", "Size": "", "ToolOther": "", "WorkName": "【高精度モード】精度検証_軽量16Nヘッド0201C装着対応", "WorkItems": [ "1. 自己計測1~3までの作業を実施する", "3. ④操作パネルの を押しながら を押し生産を開始する", "2. ③『生産』を押す", "4. 操作パネルの を押しながら⑤『はい』を押す", "5. 操作パネルの を押しながら⑥『第一』を押す", "6. 操作パネルの を押しながら⑦『いいえ』を押す", "15. 作業が終了したら、 を押しながら⑮『取外し』でノズルを取り外す", "8. 自動運転終了後、⑨『ホーム』を押す", "9. 操作パネルの を押しながら⑩『はい』を押す", "14. Nikon計測器にて、実装した基板の装着精度を確認する", "7. 操作パネルの を押しながら⑧『はい』を押す", "10. ⑪『メンテナンス』を押す", "11. ⑫『データ生成』を押す", "12. ⑬『検証結果』を押す", "13. ⑭実装後の精度を確認する" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "『はい』を押すと実装速度が遅くなる", "データ生成時は①『精度検証』・②『0201』・『高精度モード:ON』を選択しデータ生成を行う事", "SD-EJM8D05-066・011~012", "規格値:XY=±0.015mm CpK≧1.0 :θ=±5° CpK≧1.0" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:16.装着精度確認(オプション)" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "1回/3年", "ToolRecord": "校正成績書", "StdVal": "XY:±0.015㎜θ:±5°CpK≧1.0", "Method": "2次元測定器", "RecordMethod": "WEAV-G002-A05", "Other": "オプション", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『オフセット反映』を押す", "4. ④『BGA12』を選択する", "5. ⑤実装するステージを選択する", "6. ⑥『読込』を押す", "7. ⑦データが生成されたか確認する" ], "WorkPoints": [ "データロード", "レーン2生成時はここを選択する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)2", "WorkItems": [ "1. ①『段取り』を押す", "2. ②『部材準備』を押す", "3. ③『実装するステージ』を選択する", "4. ④『表示切替』を押す", "5. ⑤チェンジャユニットを取外す", "6. ⑥指定されたノズルを指定位置にセットする" ], "WorkPoints": [ "ノズルセット", "⑥指定ノズル・位置", "各チェンジャーのノズルセット箇所", "8ノズルチェンジャー", "3ノズルチェンジャー", "4ノズルチェンジャー", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す", "セット後チェンジャーを戻す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "※画像は8Nチェンジャーです" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)3", "WorkItems": [ "1. ㉖をカートにセットする", "3. 治具パレットにJIG_BGAをセットする", "2. JIG_BGA置き台にJIG_BGAをセットする", "4. ①『段取り替え』を押す", "5. ②『部材準備』を押す", "6. ③『TBL2』を押す", "7. ④『トレイ』を押し、『取付け確認』を押す。", "8. ⑤『マガジン交換』を押す", "10. ⑥『リセット』を押して、吸着開始位置をX:1、Y:1にする", "9. トレイの前扉を開け、トレイパレットをマガジンの1番にセットし、 『配置』を押す。" ], "WorkPoints": [ "ADR1 ADR16にセット", "一段目・16個 二段目・16個(斜めにセット)", "一段目", "二段目", "交換台車仕様時", "奥に当付け固定する", "トレイ仕様時", "トレイが動作し、トレイ扉のロックが解除", "コンパクトトレイ", "※トレイストッカー仕様の場合SD-EJM9D05-202、203を参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "右上から順番にBGASUS部品をセットする" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)3-1(トレイストッカー仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)3-2(トレイストッカー仕様)", "WorkItems": [], "WorkPoints": [ "トレイストッカー仕様時", "【確認順序】 13:マガジンAのドアを開けマガジンをセットする 14:マガジンAのドアを閉める 15:ボタンを押して完了 16:『配置』を押す 17:『全リセット』を押す", "レバーをつまみ引き出す", "ベアリングの間にマガジンのブロックがハマるようにセットする", "セット完了状態", "レバーがカチッと音がするまで押し込む", "マガジン側面ブロック", "上側から見た状態" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "-段取り替え(BGA部品セット)-", "マガジンA" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)4", "WorkItems": [ "8. 操作パネルの を押しながら⑧『はい』を押す", "6. 操作パネルの を押しながら⑥『はい』を押す", "5. 操作パネルの を押しながら⑤『はい』を押す", "4. 操作パネルの を押しながら④『第一』を押す", "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 操作パネルの を押しながら③『はい』を押す", "7. 自動運転終了後、⑦『ホーム』を押す", "9. 画面上の⑨『基板抜き取り』を押す", "10. ⑩『はい』を押す" ], "WorkPoints": [ "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "自己診断が開始され全て『OK』になったら自動運転~自動認識が開始する", "精度検証1/2", "コンベア上の基板情報が全てクリアされ継続生産が出来なくなります。よろしいですか?" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "自己計測(JIGBGA)5", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "6. 角度毎オフセットが表示されるので確認後 ⑥『検証データ反映』を押す", "3. ③『精度検証結果』を押す", "5. ⑤『角度毎オフセット』を押す", "7. 「第一レーンの値を他レーンに反映しますか」 と表示されるので、⑦『はい』を押す", "8. 「データの保存を行います。よろしいですか?」  と表示されるので、⑧『はい』を押す", "9. レーン2も同様に検証データ反映を行う", "4. ④『実装したステージ』を選択する" ], "WorkPoints": [ "精度検証2/2", "『検証データ反映』を実行する事によりオフセットが自動計算される", "既にレーン2での精度検証を終えている場合は『いいえ』を押す", "デュアルコンベア仕様時のみ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラス基板ジグ寺岡両面テープ", "Size": "", "ToolOther": "", "WorkName": "精度検証・実装精度確認(BGAJIG)", "WorkItems": [ "1. 自己計測1~3までの作業を実施する", "2. ②『生産』を押す", "3. ③操作パネルの を押しながら を押し生産を開始する", "4. 操作パネルの を押しながら④『はい』を押す", "5. 操作パネルの を押しながら⑤『いいえ』を押す", "7. 自動運転終了後、⑦『ホーム』を押す", "8. 操作パネルの を押しながら⑧『はい』を押す", "9. ⑨『メンテナンス』を押す", "10. ⑩『データ生成』を押す", "11. ⑪『検証結果』を押す", "13. Nikon計測器にて、実装した基板の装着精度を確認する", "14. レーン2も同様に装着精度を確認する", "12. ⑫実装後の精度を確認する", "6. 操作パネルの を押しながら⑥『はい』を押す" ], "WorkPoints": [ "精度検証データ生成の①『精度検証』を選択しデータ生成を行う事", "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "規格値_8ノズル:XY=±0.025mm CpK≧1.0 θ=±0.3° CpK≧1.0 4ノズル:XY=±0.020mm CpK≧1.0 θ=±0.08° CpK≧1.0", "規格値_8ノズル:XY=±0.025mm CpK≧1.0 θ=±0.3° CpK≧1.0 4ノズル:XY=±0.020mm CpK≧1.0 θ=±0.08° CpK≧1.0", "XY目標値:±0.025㎜ CpK:1.0以上", "『はい』を押すと実装速度が遅くなる", "デュアルコンベア仕様時のみ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:17.装着精度確認(JIG_BGA)", "検査表①:17.装着精度確認(JIG_BGA)", "検査表②:CR6.装着精度確認(チップ部品)", "検査表②:CR6.装着精度確認(チップ部品)" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "8ノズルXY=±0.025㎜θ=±0.3°CpK≧1.04ノズルXY=±0.020㎜θ=±0.08°CpK≧1.0", "Method": "-", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "2次元測定器", "Size": "", "ToolOther": "", "WorkName": "精度検証・実装精度確認(BGAJIG)", "WorkItems": [ "1. 自己計測1~3までの作業を実施する", "2. ②『生産』を押す", "3. ③操作パネルの を押しながら を押し生産を開始する", "4. 操作パネルの を押しながら④『はい』を押す", "5. 操作パネルの を押しながら⑤『いいえ』を押す", "7. 自動運転終了後、⑦『ホーム』を押す", "8. 操作パネルの を押しながら⑧『はい』を押す", "9. ⑨『メンテナンス』を押す", "10. ⑩『データ生成』を押す", "11. ⑪『検証結果』を押す", "13. Nikon計測器にて、実装した基板の装着精度を確認する", "14. レーン2も同様に装着精度を確認する", "12. ⑫実装後の精度を確認する", "6. 操作パネルの を押しながら⑥『はい』を押す" ], "WorkPoints": [ "精度検証データ生成の①『精度検証』を選択しデータ生成を行う事", "=重要=サポートプレート上にPINが差さって無い事を確認!! ⇒ガラス基板破損の恐れあり", "規格値_8ノズル:XY=±0.025mm CpK≧1.0 θ=±0.3° CpK≧1.0 4ノズル:XY=±0.020mm CpK≧1.0 θ=±0.08° CpK≧1.0", "規格値_8ノズル:XY=±0.025mm CpK≧1.0 θ=±0.3° CpK≧1.0 4ノズル:XY=±0.020mm CpK≧1.0 θ=±0.08° CpK≧1.0", "XY目標値:±0.025㎜ CpK:1.0以上", "『はい』を押すと実装速度が遅くなる", "デュアルコンベア仕様時のみ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:17.装着精度確認(JIG_BGA)", "検査表①:17.装着精度確認(JIG_BGA)", "検査表②:CR6.装着精度確認(チップ部品)", "検査表②:CR6.装着精度確認(チップ部品)", "WEAV-G002-A05WEAV-G002-A03" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "1回/3年", "ToolRecord": "校正成績書", "StdVal": "8ノズルXY=±0.025㎜θ=±0.3°CpK≧1.04ノズルXY=±0.020㎜θ=±0.08°CpK≧1.0", "Method": "2次元測定器", "RecordMethod": "WEAV-G002-A05WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『 』を押す", "4. ④『吸着ミス率計測を押す』", "5. ⑤『0402』を押す", "7. ⑦使用するノズルを選択する", "8. ⑧『読込』を押す", "9. ⑨データが生成されたか確認する", "6. ⑥使用するステージを選択する" ], "WorkPoints": [ "データロード" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)2", "WorkItems": [ "1. ①『段取り』を押す", "5. ⑤指定されたノズルを指定位置にセットする", "6. ⑥『TBL2』を押す", "7. ⑦チェンジャユニットを取外す", "8. ⑧指定されたノズルを指定位置にセットする", "2. ②『TBL1』を押す", "3. ③『表示切替』を押す", "4. ④チェンジャユニットを取外す" ], "WorkPoints": [ "セット後チェンジャーを戻す", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す", "セット後チェンジャーを戻す", "⑤指定ノズル・位置", "⑧指定ノズル・位置", "ノズルセット", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "※画像は全て16N+16Nのものです" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)3", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "フィーダセット", "1. ①『段取り替え』を押す", "2. ②『部材準備』を押す", "3. ③『TBL1』を押す", "4. ④『フィーダ』を押す", "5. ⑤指定された位置にテープフィーダをセットする", "6. ⑥『TBL2』へ切り替え、手順 5を実施する" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)4", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "7. ⑦ホームを押すと『コンベアの終了処理を行います  よろしいですか?』と表示されるので  操作パネルの  を押しながら『確認』を押す", "6. 操作パネルの を押しながら⑥『実行』を押す", "基板幅変更", "サポートピン取付け", "1. 操作パネルのサーボSWをOFFし、前扉を開ける", "2. フロントヘッドを手で、奥に回避させる", "ヘッド(ノズル)が下がってい無い事を確認 ⇒ 干渉の恐れ有", "3. サポートプレートにピン取付ける(左図参考)", "4. 前扉を閉じ、操作パネルのサーボSWをONに戻す", "実装エリア", "サポートピン", "実装エリア", "サポートピン", "右→左流れ仕様時", "左→右流れ仕様時", "幅寄せ動作が開始する", "1. ①『段取り』を押す", "2. ②『部材準備』を押す", "3. ③『コンベア』を押す", "4. ④『幅調整』を押す", "5. ⑤『レーン2』を押す" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)5", "WorkItems": [ "1. ①『生産管理』を押す", "2. ②『 』を押す", "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 設備が搬入待ち状態になった事を確認し、基板を設備に搬入する", "4. 基板が搬入され、生産が開始される", "3. ③『クリアするレーン』を押す", "4. ④『クリア』を押す", "5. 生産情報等の各項目が『0』になっている事を確認する" ], "WorkPoints": [ "生産管理情報クリア", "0402RCミス率確認 1/2", "自己診断が開始され、すべて『OK』になったら自動運転が開始される" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)60402RC", "WorkItems": [ "3. 操作パネルの を押しながら③『はい』を押す", "1. 生産が終了したら①『サイクル停止』を押す", "2. サイクル停止したら、②『ホーム』を押す", "4. ④『生産管理』を押す", "5. ⑤『吸着情報』を押す", "6. ⑥『実装したステージ』を選択し、吸着情報の確認を行う", "7. ⑦『印刷』を押し、画面のコピーをSDに保存する", "8. ⑧『実装したステージのR側』を押す", "9. ⑨『印刷』を押し、画面のコピーをSDに保存する", "10. SDに保存した画面のハードコピーを貼付け用ファイルに 貼付けプリントアウトし検査書に添付する" ], "WorkPoints": [ "0402RCミス率 2/2", "規格値:エラー率0.10%以下(1000点/ヘッド以上実装)" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:17.吸着ミス率" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "ミス率確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー率0.10%以下(1000点/ヘッド以上実装)", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(チップ)60402RC", "WorkItems": [ "3. 操作パネルの を押しながら③『はい』を押す", "1. 生産が終了したら①『サイクル停止』を押す", "2. サイクル停止したら、②『ホーム』を押す", "4. ④『生産管理』を押す", "5. ⑤『吸着情報』を押す", "6. ⑥『実装したステージ』を選択し、吸着情報の確認を行う", "7. ⑦『印刷』を押し、画面のコピーをSDに保存する", "8. ⑧『実装したステージのR側』を押す", "9. ⑨『印刷』を押し、画面のコピーをSDに保存する", "10. SDに保存した画面のハードコピーを貼付け用ファイルに 貼付けプリントアウトし検査書に添付する" ], "WorkPoints": [ "0402RCミス率 2/2", "規格値:エラー率0.10%以下(1000点/ヘッド以上実装)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "検査表①:17.吸着ミス率", "WEAV-G002-A05" ] }
{ "QualityItem": "ミス率確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ノーエラーな事(500点/ヘッド以上実装)", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "レーン切替(デュアル→シングル)", "WorkItems": [ "1. ①『マシン調整』を押す", "2. ②『コンベア』を押す", "3. ③『レーン切替』を押す", "4. 操作パネルの を押しながら④『レーン切替』を押す", "5. ⑤『確認』を押す" ], "WorkPoints": [ "下受けピンが付いてい無い事を確認する", "切替動作中" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "広範囲実装精度1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『広範囲実装精度検証』を押す", "5. ⑤『読込』を押す", "6. ⑥データが生成されたか確認する", "4. ④使用するステージを選択する" ], "WorkPoints": [ "データロード" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "広範囲実装精度2", "WorkItems": [ "1. ①『段取り』を押す", "5. ⑤指定されたノズルを指定位置にセットする", "6. ⑥『TBL2』を押す", "7. ⑦チェンジャユニットを取外す", "8. ⑧指定されたノズルを指定位置にセットする", "2. ②『TBL1』を押す", "3. ③『表示切替』を押す", "4. ④チェンジャユニットを取外す" ], "WorkPoints": [ "セット後チェンジャーを戻す", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す", "セット後チェンジャーを戻す", "⑤指定ノズル・位置", "⑧指定ノズル・位置", "ノズルセット", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "※画像は全て16N+16Nのものです" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "広範囲実装精度3", "WorkItems": [ "1. ①『段取り替え』を押す", "2. ②『TBL1』を押す", "3. ③『フィーダ』を押す", "4. ④指定された位置にテープフィーダをセットする", "5. ⑤『TBL2』へ切り替え、手順3~4を実施する" ], "WorkPoints": [ "フィーダセット" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "広範囲実装精度4", "WorkItems": [ "6. ⑥ホームを押すと『コンベアの終了処理を行います  よろしいですか?』と表示されるので  操作パネルの  を押しながら『確認』を押す", "5. 操作パネルの を押しながら⑤『実行』を押す", "3. サポートプレートにピン取付ける(左図参考)", "4. 前扉を閉じ、操作パネルのサーボSWをONに戻す", "1. ①『段取り』を押す", "2. ②『部材準備』を押す", "3. ③『コンベア』を押す", "4. ④『幅調整』を押す", "1. 操作パネルのサーボSWをOFFし、前扉を開ける", "2. フロントヘッドを手で、奥に回避させる" ], "WorkPoints": [ "基板幅変更", "サポートピン取付け", "ヘッド(ノズル)が下がってい無い事を確認 ⇒ 干渉の恐れ有", "サポートピン", "幅寄せ動作が開始する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "ガラエポ基板", "Size": "", "ToolOther": "350×590", "WorkName": "広範囲実装精度5", "WorkItems": [ "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 設備が搬入待ち状態になった事を確認し 基板を設備に搬入する", "4. 基板が搬入され、生産が開始される", "1. 生産が終了したら①『サイクル停止』を押す", "2. サイクル停止したら、②『ホーム』を押す", "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 設備が搬入待ち状態になった事を確認し 基板を設備に搬入する", "4. 基板が搬入され、生産が開始される", "1. 生産が終了したら①『サイクル停止』を押す", "2. サイクル停止したら、②『ホーム』を押す" ], "WorkPoints": [ "広範囲実装精度確認 1/2", "自己診断が開始され、すべて『OK』になったら自動運転が開始される", "規格値:XY=±0.050㎜ θ=±5° Cpk≧1.0", "広範囲実装精度確認 2/2", "広範囲実装精度確認 1/2", "自己診断が開始され、すべて『OK』になったら自動運転が開始される", "規格値:XY=±0.050㎜ θ=±5° Cpk≧1.0", "広範囲実装精度確認 2/2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "-", "Method": "-", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "2次元測定器", "Size": "", "ToolOther": "", "WorkName": "広範囲実装精度5", "WorkItems": [ "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 設備が搬入待ち状態になった事を確認し 基板を設備に搬入する", "4. 基板が搬入され、生産が開始される", "1. 生産が終了したら①『サイクル停止』を押す", "2. サイクル停止したら、②『ホーム』を押す", "3. ③『はい』を押す", "4. Nikon計測器にて、実装した基板の装着精度を確認する" ], "WorkPoints": [ "広範囲実装精度確認 1/2", "自己診断が開始され、すべて『OK』になったら自動運転が開始される", "規格値:XY=±0.050㎜ θ=±5° Cpk≧1.0", "広範囲実装精度確認 2/2" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:16.広範囲装着精度確認(チップ部品)" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "精度確認", "ToolManageNo": "-", "ToolCycle": "1回/3年", "ToolRecord": "校正成績書", "StdVal": "XY=±0.050㎜θ=±5°Cpk≧1.0", "Method": "2次元測定器", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(混載)1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『 』を押す", "5. ⑤『混載』を押す", "7. ⑦『読込』を押す", "8. ⑧データが生成されたか確認する", "4. ④『吸着ミス率計測を押す』", "6. ⑥使用するステージを選択する" ], "WorkPoints": [ "データロード" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "削除" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(混載)2", "WorkItems": [ "1. ①『段取り』を押す", "2. ②『TBL1』を押す", "3. ③『表示切替』を押す", "4. ④チェンジャユニットを取外す", "5. ⑤指定されたノズルを指定位置にセットする", "6. ⑥『TBL2』を押す", "7. ⑦チェンジャユニットを取外す", "8. ⑧指定されたノズルを指定位置にセットする" ], "WorkPoints": [ "⑤指定ノズル・位置", "⑧指定ノズル・位置", "ノズルセット", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す", "セット後チェンジャーを戻す", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャーを取り外す", "セット後チェンジャーを戻す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "※画像は全て16N+16Nのものです" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(混載)3", "WorkItems": [ "1. ①『段取り替え』を押す", "2. ②『TBL1』を押す", "3. ③『フィーダ』を押す", "4. ④指定された位置にテープフィーダをセットする", "5. ⑤『TBL2』へ切り替え3~4を実施する" ], "WorkPoints": [ "にて表示切替え", "16ノズルヘッド時フィーダ配列7L:1005R 7R:1005C 8L:1608R 8R:1608C9L:2125R9L:2125C10L:3216R10R:3216C11L:MTR11R:SMINITR", "8/4ノズルヘッド時フィーダ配列7L:1005R 7R:1005C 8L:1608R 8R:1608C9L:2125R9L:2125C10L:3216R10R:3216C11L:MTR11R:SMINITR12:6432R13:AL615:SOP-1", "フィーダセット" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(混載)4", "WorkItems": [ "5. ⑤ホームを押すと『コンベアの終了処理を行います  よろしいですか?』と表示されるので  操作パネルの  を押しながら『確認』を押す", "4. 操作パネルの を押しながら④『実行』を押す", "1. 操作パネルのサーボSWをOFFし、前扉を開ける", "2. フロントヘッドを手で、奥に回避させる", "3. サポートプレートにピン取付ける(左図参考)", "4. 前扉を閉じ、操作パネルのサーボSWをONに戻す", "1. ①『段取り』を押す", "2. ②『コンベア』を押す", "3. ④『幅調整』を押す" ], "WorkPoints": [ "サポートピン取付け", "ヘッド(ノズル)が下がってい無い事を確認 ⇒ 干渉の恐れ有", "Ast/Bst両ステージ取付けの事", "サポートピン", "サポートピン", "右→左流れ仕様時", "左→右流れ仕様時", "基板幅変更", "幅寄せ動作が開始する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(混載)5", "WorkItems": [ "1. ①『生産管理』を押す", "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 設備が搬入待ち状態になった事を確認し、基板を設備に搬入する", "4. 基板が搬入され、生産が開始される", "3. ③『クリア』を押す", "2. ②『 』を押す", "4. 生産情報等の各項目が『0』になっている事を確認する" ], "WorkPoints": [ "生産管理情報クリア", "自己診断が開始され、すべて『OK』になったら自動運転が開始される", "混載ミス率確認 1/2", "2枚実装する事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "削除" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "吸着ミス率(混載)6", "WorkItems": [ "1. 生産が終了したら①『サイクル停止』を押す", "2. サイクル停止したら、②『ホーム』を押す", "3. 操作パネルの を押しながら③『はい』を押す", "4. ④『生産管理』を押す", "5. ⑤稼働情報を確認し、トラブル停止が無い事を確認する", "6. ⑥『印刷』を押し、画面のコピーをSDに保存する", "7. ⑦『吸着情報』を押す", "10. ⑩『実装したステージのR側』を押し、8~9を実施する", "11. SDに保存した画面のハードコピーを貼付け用ファイルに 貼付けプリントアウトし検査書に添付する", "9. ⑨『印刷』を押し、画面のコピーをSDに保存する", "8. ⑧吸着情報を確認する" ], "WorkPoints": [ "混載ミス率 2/2", "規格値:エラー率0.05%以下(2000点/ヘッド以上実装)" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:17.吸着ミス率" ], "WorkTypes": [ "■安全作業" ], "Words": [ "削除", "WEAV-G002-A05" ] }
{ "QualityItem": "ミス率確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー率0.05%以下(2000点/ヘッド以上実装)", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "トレイフィーダー実装ミス率確認①", "WorkItems": [ "3. ③『 』を押す", "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "4. ④『吸着ミス率計測を押す』", "5. ⑤仕様に応じて『sopTray』または『各チップトレイ』を押す", "6. ⑥使用するステージを選択する", "7. ⑦『読込』を押す", "8. ⑧データが生成されたか確認する" ], "WorkPoints": [ "データロード" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "8NH用ノズル3NH用ノズル16NH用ノズル", "Size": "", "ToolOther": "", "WorkName": "トレイフィーダー実装ミス率確認②", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "1. ①『部材準備』を押す", "2. ②『表示切替』を押す", "3. ③チェンジャユニットを取外す", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャを取外す", "4. ④指定されたノズルをセットする", "指定ノズル", "-段取り替え(ノズルセット)-", "5. ⑤TBL2を押す", "6. ⑥チェンジャユニットを取外す", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャを取外す", "指定ノズル", "7. ⑦指定されたノズルをセットする", "セット後チェンジャーを戻す", "セット後チェンジャーを戻す", "※画像は全て8N+8Nのものです", "マシン仕様を確認して治具を取付ける" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "治具パレット(SOP)治具パレット(5025チップ)", "Size": "", "ToolOther": "FM-1690FM-6088", "WorkName": "トレイフィーダー実装ミス率確認③", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "-段取り替え(トレイ部品セット)-", "1. 治具パレット(2枚)をトレイパレットに取付ける", "2. ①『段取り替え』ボタンを押す", "3. ②『部材準備』を押す", "4. ③『TBL1』を押す", "5. ④『トレイ』を押す", "6. ⑤『マガジン交換』を押す", "トレイが動作し、トレイ扉のロックが解除", "コンパクトトレイ", "7. トレイの前扉を開け、トレイパレットをマガジンの 1・46番にセットする", "8. ⑥『配置』を押す", "9. ⑦『全リセット』を押して、残数を36にする", "10. リア側もトレイの場合、4にて『TBL2』を押し5~9を 実施する。", "※画像は全てSOPのものです", "マシン仕様を確認して治具を取付ける", "※トレイストッカー仕様の場合SD-EJM9D05-204,205を参照" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "FM-1690FM-6088", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "トレイフィーダー実装ミス率確認③-1(トレイストッカー仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "トレイフィーダー実装ミス率確認③-2(トレイストッカー仕様)", "WorkItems": [], "WorkPoints": [ "トレイストッカー仕様時", "【確認順序】 16:マガジンAのドアを開けマガジンをセットする 17:マガジンAのドアを閉める 18:ボタンを押して完了 ※16~18をマガジンBも実施する 19:『配置』を押す 20:『全リセット』を押す", "レバーをつまみ引き出す", "ベアリングの間にマガジンのブロックがハマるようにセットする", "上側から見た状態", "セット完了状態", "マガジン側面ブロック", "レバーがカチッと音がするまで押し込む" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "マガジンA", "-段取り替え(トレイ部品セット)-", "マガジンB" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "治具パレット(SOP)治具パレット(5025チップ)", "Size": "", "ToolOther": "FM-1690FM-6088", "WorkName": "トレイフィーダー実装ミス率確認④", "WorkItems": [ "2. 操作パネルの を押しながら を押し 生産を開始する", "2. ②『稼働情報』を押す", "3. ③『クリア』を押す", "4. ④『はい』を押す", "5. 生産情報等の各項目が『0』になっている事を 確認する", "1. ①『生産』を押す", "3. 機械が搬入待ち状態になった事を確認し、 治具パレットを搬入する", "4. 基板が搬入され、生産が開始される", "5. マシン仕様に応じて生産を実施する 合計4枚 (SOP 120点) 合計4枚 (5025チップ 256点)", "1. ①『生産管理』を押す" ], "WorkPoints": [ "自己診断が開始され、すべて『OK』になったら自動運転が開始される", "マシン仕様を確認して治具を搬入する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "-生産準備(生産管理情報クリア)-", "-トレイミス率確認 1/2-", "= 重要 =サポートプレート上にピンが刺さって無い事を確認!!" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "FM-1690FM-6088", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "トレイフィーダー実装ミス率確認⑤", "WorkItems": [ "1. 生産終了したら、①『サイクル停止』を押し サイクル停止させる", "2. サイクル停止したら、②『ホーム』を押し 生産を終了させる", "3. ③『はい』を押す", "4. ④『生産管理』を押す", "5. ⑤『印刷』を押し、画面のコピーをSDに保存する", "8. ⑧吸着情報を確認を行う", "9. ⑨『印刷』を押し、画面のコピーをSDに保存する", "7. ⑦『TBL2』を押す", "10. SDにセーブした画面のハードコピーを貼付け用 ファイルに貼付けプリントアウトし、検査書に添付する", "6. ⑥『吸着情報』を押す" ], "WorkPoints": [ "エラー無き事(120点実装)" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:19.トレイフィーダミス率確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "-トレイミス率確認 2/2-", "WEAV-G002-A05" ] }
{ "QualityItem": "ミス率確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "各ヘッドノーエラーの事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "レーン切替(シングル→デュアル)", "WorkItems": [ "1. ①『マシン調整』を押す", "2. ②『コンベア』を押す", "3. ③『レーン切替』を押す", "5. 左画面の表示が出たら電源を立ち上げ直す", "4. 操作パネルの を押しながら④『レーン切替』を押す" ], "WorkPoints": [ "電源 OFF→ON", "下受けピンが付いてい無い事を確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "側方照明確認1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『 』を押す", "4. ④『側方照明確認』を押す", "5. ⑤『読込』を押す", "8. ⑧『ティーチ』を押す", "9. ⑨『フィーダ』を押す", "10. ⑩『部品選択』を押す", "11. ⑪『QFP-JIG』を押す", "6. ⑥データが生成されたか確認する", "7. ⑦『生産データ』を押す" ], "WorkPoints": [ "データのノズル配置通りにノズルをチェンジャーにセットする" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "側方照明確認2", "WorkItems": [ "1. ①『設定』を押す", "2. ②『仮想吸着』を押す", "3. ③『ESC』を押す", "4. ④『吸着』を押す", "5. BGAを2番ノズルに吸着させる", "6. ⑤『確認』を押す", "7. ⑥『テスト』を押す", "8. ⑦認識結果が『ANS=100』である事を確認する", "9. ⑧『印刷』を押し、画面のコピーをSDに保存する", "10. ⑨『ESC』を押す", "11. ⑩『ホーム』を押し部品を取る", "12. ⑪『はい』を押す", "13. SDにセーブした画面のハードコピーを、貼付け用ファイル に貼付けプリントアウトし、検査書に添付する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:18.側方照明確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ANS=100", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "Zコプラナリティ確認1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『 』を押す", "4. ④『Zコプラナリティ確認』を押す", "5. ⑤『読込』を押す", "6. ⑥データが生成されたか確認する", "7. ⑦『生産データ』を押す", "8. ⑧『ティーチ』を押す", "9. ⑨『フィーダ』を押す", "10. ⑩確認するTBLを選択する", "11. ⑪『部品選択』を押す", "12. ⑫『FM-4016』を押す" ], "WorkPoints": [ "データのノズル配置通りにノズルをチェンジャーにセットする", "8・4ノズルヘッド時:『FM-0731』" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "LC-DUMMY", "Size": "16ノズルヘッド", "ToolOther": "FM-4016", "WorkName": "Zコプラナリティ確認2", "WorkItems": [ "1. ①『設定』を押す", "2. ②『仮想吸着』を押す", "3. ③『ESC』を押す", "4. ④『吸着』を押す", "6. ⑤『確認』を押す", "7. ⑥『テスト』を押す", "8. ⑦認識結果が『ANS=100』である事を確認する", "9. ⑧ を押し、⑨ を押す", "10. ⑩認識画面にて左下の測定値を記入する", "11. ⑪ を1回押す", "5. 治具を画面指示されたノズルに吸着させる", "12. ⑫『再認識』を押し手順8~11を2回実施する", "13. ⑬『ESC』を押す", "14. ⑭『ホーム』を押し、治具を取外す", "15. ⑮『はい』を押す" ], "WorkPoints": [ "規格値(16ノズルヘッド)・A=50μm±30μm・B=70μm±30μm・C=50μm±30μm・D=70μm±30μm", "規格値(8/4/3ノズルヘッド)・A=50μm±30μm・B=60μm±30μm・C=70μm±30μm・D=80μm±30μm" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:21.Zコプラナリティ確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "A=MaxU・B=MaxL・C=MaxD・D=MaxR", "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-4016", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "A=50μm±30μmB=70μm±30μmC=50μm±30μmD=70μm±30μm", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "LC-DUMMY", "Size": "16ノズルヘッド", "ToolOther": "FM-0731", "WorkName": "Zコプラナリティ確認2", "WorkItems": [ "1. ①『設定』を押す", "2. ②『仮想吸着』を押す", "3. ③『ESC』を押す", "4. ④『吸着』を押す", "6. ⑤『確認』を押す", "7. ⑥『テスト』を押す", "8. ⑦認識結果が『ANS=100』である事を確認する", "9. ⑧ を押し、⑨ を押す", "10. ⑩認識画面にて左下の測定値を記入する", "11. ⑪ を1回押す", "5. 治具を画面指示されたノズルに吸着させる", "12. ⑫『再認識』を押し手順8~11を2回実施する", "13. ⑬『ESC』を押す", "14. ⑭『ホーム』を押し、治具を取外す", "15. ⑮『はい』を押す" ], "WorkPoints": [ "規格値(16ノズルヘッド)・A=50μm±30μm・B=70μm±30μm・C=50μm±30μm・D=70μm±30μm", "規格値(8/4/3ノズルヘッド)・A=50μm±30μm・B=60μm±30μm・C=70μm±30μm・D=80μm±30μm" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "A=MaxU・B=MaxL・C=MaxD・D=MaxR", "検査表①:21.Zコプラナリティ確認", "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-0731", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "A=50μm±30μmB=60μm±30μmC=70μm±30μmD=80μm±30μm", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "厚み計測1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『 』を押す", "4. ④『厚み計測』を押す", "5. ⑤『読込』を押す", "6. ⑥データが生成されたか確認する", "7. ⑦『段取り替え』を押す", "9. ⑨『確認するステージ』を選択する", "8. ⑧『フィーダ』を押す", "10. ⑩指定された位置テープフィーダをセットする" ], "WorkPoints": [ "データのノズル配置通りにノズルをチェンジャーにセットする" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "JIG" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "厚み計測2", "WorkItems": [ "1. ①『生産データ』を押す", "2. ②『ティーチ』を押す", "3. ③『フィーダ』を押す", "4. ④『部品選択』を押す", "7. ⑦『テスト』を押す", "6. ⑥『吸着』を押す", "11. ⑪『設定』を押す", "12. ⑫『pos8』を押す", "10. ⑩『ESC』を押す", "8. ⑧ANS=100を確認し、ΔTの値を記入する", "9. ⑨『再認識』を押し、残り2回計測する", "5. ⑤『1005Thickness』を押す", "13. ⑬『ESC』を押す", "14. 手順6~13を実施する", "15. ⑭『ホーム』を押す", "16. ⑮『はい』を押す" ], "WorkPoints": [ "規格値:ΔT=±40μm", "規格値:ΔT=±40μm", "16ノズルヘッド:『pos1』⇒『pos8』⇒『pos9』⇒『pos16』8ノズルヘッド:『pos1』⇒『pos4』⇒『pos5』⇒『pos8』4ノズルヘッド:『pos1』⇒『pos4』3ノズルヘッド:『pos1』⇒『pos3』" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:22.厚み計測", "検査表①:22.厚み計測" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ΔT=±40μm", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "高さセンサ確認1", "WorkItems": [ "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『基板反り機能』を押す", "4. ④『読込』を押す", "5. ⑤データが生成されたか確認する", "1. ①『マシン調整』を押す", "4. ④『動作パラメータ』を押す", "3. ③『高さセンサ』を押す", "2. ②『 』を押す", "5. ⑤基板反り勾配許容値を『10.000』にする" ], "WorkPoints": [ "レーン2生成時はここを選択する", "データロード", "データのノズル配置通りにノズルをチェンジャーにセットする", "マシン設定", "確認作業終了後、勾配許容値を『0.500』に再設定する事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "高さセンサ確認2", "WorkItems": [ "1. ①『生産』を押す", "2. ②操作パネルの を押しながら を押し生産を開始する", "3. 機械が搬入待ち状態になった事を確認し、基板を 搬入する", "4. 基板が搬入され、生産が開始される", "5. 実装後目視にて実装状態を確認する", "6. レーン2も同様に確認する" ], "WorkPoints": [ "自己診断が開始され、すべて『OK』になったら自動運転が開始される", "実装ずれ(θずれ、欠品、ばらまき)無き事", "実装ずれ(θずれ、欠品、ばらまき)無き事" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:23.高さセンサ", "検査表①:23.高さセンサ" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "実装ずれ(θずれ、欠品、ばらまき)無き事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "下受けピン自動交換確認1", "WorkItems": [ "2. ②『動作パラメータ』を押す", "1. ①『サービスマン』を押す", "3. ③下受けピン自動交換の設定が『ON』になって いる事を確認する", "1. ①『メンテナンス』を押す", "2. ②『精度検証』を押す", "3. ③『下受けピン自動交換機能』を押す", "4. ④『読込』を押す", "5. ⑤データが生成されたか確認する" ], "WorkPoints": [ "オプション設定確認", "データロード", "レーン2生成時はここを選択する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "下受けピン自動交換確認2", "WorkItems": [ "1. 下受けピン用ノズルをチェンジャーにセットする", "1. ①『段取り』を押す", "2. ②『部材準備』を押す", "3. ③『コンベア』を押す", "4. ④『下受けピン交換』を押す", "5. ⑤『確認』を押す", "6. 画面の⑥をタッチする", "7. ⑦下受けピン保持数を10 と入力し『ENT』を押す", "8. ⑧入力した本数になっているか確認する" ], "WorkPoints": [ "ノズルセット", "下受けピン交換用ノズルチェンジャー", "動作設定", "ノズルセット方法・16/8ノズルヘッド用 チェンジャーに入れ時計回りにセット位置まで90度回す・3/4ノズルヘッド用 チェンジャーに入れて時計回りにセット位置まで回す", "各ステージ、ヘッド仕様に合わせてセットする事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "16/8ノズル用", "3/4ノズル用", "切り欠き左側" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "下受けピン自動交換確認3", "WorkItems": [ "1. ①『ピン登録』を押す", "2. ②の画面のメッセージが表示されたらピンを ホームポジションにセットする", "3. ③『実行』を押す", "4. ④1~10間までがホーム表示(緑色)になっている事 を確認する", "5. ⑤『ピン交換』を押す", "6. ⑥1~10間までが配置表示(青色)になっている事 を確認する", "7. ⑦『ピン戻し』を押す", "8. 再度手順5~7を実施する" ], "WorkPoints": [ "ホームポジション", "下受けピン配置位置", "緑色表示されていない場所は再度ピンの位置を確認し、手順1から実施する", "ピンが10本配置位置にある事を目視確認", "ピンが10本ホーム位置に戻っている事を目視確認する", "動作確認1/2" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "ボルトとボルトの間にセットする", "【左⇒右流れ】【基板右下基準】", "【右⇒左流れ】【基板左下基準】" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "下受けピン自動交換確認4", "WorkItems": [ "1. ①『ピン情報削除』を押す", "1. ①『マシン調整』を押す", "2. ②『ヘッドを押す』", "3. ③『pos1』を押す", "4. ④『取外し』を押す", "5. ⑤『取付け』を押す", "6. ⑥『取外し』を押す", "7. レーン2も同様に確認する", "3. ③『確認』を押す", "4. 画面の④を押す", "5. ⑤『0』と入力し『ENT』を押す", "2. ②『実行』を押す" ], "WorkPoints": [ "動作確認2/2", "下受けピン用ノズルがチェンジャーに戻る事を確認する", "下受けピン用ノズルが取付いた事を確認する", "下受けピン用ノズルがチェンジャーに戻る事を確認する", "下受けピンを取り外す" ], "Tolks": [], "InspectionNo": "WEAV-G002-A05", "InspectionItems": [ "検査表①:24.下受けピン自動交換機能の動作確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A05" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A05", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(CeTaQ測定準備1)", "WorkItems": [ "1. 準備物を確認する", "2. ①③の電源を入れる", "3. 計測用パソコンの電源を入れる", "5. 『NI MAX』を起動する", "6. 『NI cDAQ-9191\"cDAQ9191-FM804-023\"』を選択する", "4. パスワードに『CmForce』と入力しEnterを押す" ], "WorkPoints": [ "①計測センサ②分銅200g(センサ確認・キャリブ用)③無線ルーター④計測用パソコン", "※計測センサを20分以上通電させる事" ], "Tolks": [], "InspectionNo": "WEAV-G002-A03", "InspectionItems": [ "検査表①:16WC1.CetaQセットアップ" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A03" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:141Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(CeTaQ測定準備2)", "WorkItems": [ "1. 『Self-Test』を選択する", "2. 『The self test completed successfully』が表示されたか確認する", "3. 『×』を押し終了する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(本体側設定1)", "WorkItems": [ "1. オプションライセンスが登録されている事を確認する", "2. 定荷重制御1.0NをONにする" ], "WorkPoints": [ "サービスエンジニアに設定", "定荷重制御(前側)(後側)を仕様に基づき『ON』にする", "ページ切替" ], "Tolks": [], "InspectionNo": "WEAV-G002-A03", "InspectionItems": [ "検査表①:16WC2.オプションライセンス登録確認" ], "WorkTypes": [ "■安全作業" ], "Words": [ "1.オプションライセンスを登録する", "検査表①:16WC3.定荷重制御設定確認", "WEAV-G002-A03" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "230CSノズル", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(本体側設定2)", "WorkItems": [ "1. ①『段取り』を押す", "4. ④『確認』を押す", "5. ⑤『SD』を押し、読み込み元をSDに切り替える", "2. ②『ファイル操作』を押す", "3. ③マシンデータが入ったSDカードをセットする", "6. ⑥対象の実装データを選択する", "7. ⑦『SD⇒マシン』を押し、データのロードを行う", "8. ⑧『はい』を押す", "9. ⑨データが読み込まれたか、確認する", "1. ①『部材準備』を押す", "2. ②『表示切替』を押す", "3. ③チェンジャユニットを取外す", "4. ④指定位置に230CSノズルをセットする" ], "WorkPoints": [ "指定位置", "WX_**_F#F#_A-$_LOAD_MEASUREMENT*はヘッド・#は供給部構成・$は確認するヘッド ⇒ 設備に合わせて選択する事", "(例) WX_1616_F17F17_A-F_LOAD_MEASUREMENT", "デュアルレーン仕様時もレーン1のみロードする", "レバーを左に倒すとロックが外れるレバーを左に倒したままチェンジャを取外す", "セット後チェンジャを戻す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "-データロード-", "-ノズルセット-" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(本体側設定3)", "WorkItems": [ "1. .基板幅を210㎜に合わせる", "2. レーン1に計測センサを写真の向きにセットする", "4. 装着設定確認をする", "5. ソフトスイッチ設定を行う", "3. 下受けプレートを上昇させる(計測センサをクランプさせる)" ], "WorkPoints": [ "左 ⇒ 右流れ仕様", "右 ⇒ 左流れ仕様", "装着・幅調整・基板認識・ノズル認識をON後は全てOFFに設定する", "計測センサの端面をガイドのマークセンターに合わせる", "左 ⇒ 右流れ仕様", "右 ⇒ 左流れ仕様" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "装着2段動作(下降):2段下降2段動作速度(下降):×0.6に設定されている事を確認", "210.00と表示されていない場合は手入力する", "搬送方向が変わっても向きは変えない", "16..基板幅を210㎜に合わせる" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(CeTaQキャリブレーション1)", "WorkItems": [ "1. 『CmForce』を起動する", "2. 『default.ini』を選択する", "3. 『Setup⇒Hardware』を選択する", "4. 計測センサに何も載っていない状態で『Meas.1』を押す", "5. 『Std.Dev.の値が40E-6以下』である事を確認する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "40×10-6N以下", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(CeTaQキャリブレーション2)", "WorkItems": [ "1. 計測センサ中央に分銅200gを載せる", "2. 『Meas.2』を押す", "5. 1で載せた分銅を取り除く", "4. 『Back』を押し、メインメニューに戻る", "3. 『Std.Dev.の値が40E-6以下』である事を確認する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "40×10-6N以下", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(キャリブレーションテスト確認)", "WorkItems": [ "2. 『Start』を押す", "4. 分銅を載せた時の値を確認する", "6. 『Back』を押し、メインメニューに戻る", "1. 『Measurement』を押す", "3. 計測センサ中央に分銅200gを載せる", "5. 『Stop』を押し分銅を取り除く", "7. 『Yes』を押し、メインメニューに戻る" ], "WorkPoints": [ "グラフ値が1.96Nを表しているか確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "2.''Measurement''を押す" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "1.96N", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(本体キャリブレーション1)", "WorkItems": [ "2. 本体設備をSTARTさせる", "4. 『F1』を押す", "6. 『サイクル停止』を押す", "1. 『Measure』を押す", "3. 『はい』を押す", "5. 『Start』を押す", "7. サイクル停止後『Stop 』を押す" ], "WorkPoints": [ "クランプと同時に押す (理由:クランプの衝撃をひろい、誤った測定結果が出てしまう為)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "作業確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通りである事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(本体キャリブレーション2)", "WorkItems": [ "9. 『Peak』を押す", "11. 『Search』を押し、Detectedの値が 48になっているか確認する", "8. 『Back』を押す", "10. 『# Peaks exp.』に48を入力する", "12. 『Back』を押す", "13. 波形の頂点にて計測されているか確認する", "14. 『Statistic』を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "CeTaQサンプリングレ-ト:4.8kHzフィルタ:140Hz", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(本体キャリブレーション3)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "WEAV-G002-A03", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A03" ] }
{ "QualityItem": "荷重確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "F1:0.3≦F1≦1.3F2:0.5≦F2≦1.5", "Method": "目視", "RecordMethod": "WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "データ保存用SDカード", "Size": "", "ToolOther": "", "WorkName": "16NH定荷重制御(装着荷重検査)", "WorkItems": [ "1. 16NH定荷重制御(本体キャリブレーション)の1~3を実施する", "2. 『F1.0』を選択する", "3. 16NH定荷重制御(本体キャリブレーション)の5~17を実施する", "4. Max-Min欄で結果を確認する", "5. 『Windows ⇒ Snipping Tool』を選択する", "7. 『保存』を押す", "8. SDカードに保存する", "9. 保存したデータを印刷する", "6. 測定結果範囲を選択する", "10..検査実施後、7、8項目 定荷重制御(前後)はOFFの設定にする" ], "WorkPoints": [ "規格値:Max;1.0N以下 Min;0.6N以上", "拡張子を(PNG)にする" ], "Tolks": [], "InspectionNo": "WEAV-G002-A03", "InspectionItems": [ "検査表①:16WC7.装着荷重確認①", "検査表①:16WC7.装着荷重確認①" ], "WorkTypes": [ "■安全作業" ], "Words": [ "Head:16はここを押して確認する", "1CVV0001_F", "WEAV-G002-A03" ] }
{ "QualityItem": "荷重確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "Max:1.0N以下Min:0.6N以上", "Method": "目視", "RecordMethod": "WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "PIP照明確認1", "WorkItems": [ "1. ①『段取り』を押す", "2. ②『ファイル操作』を押す", "3. ③マシンデータが入ったSDカードをセットする", "4. ④『確認』を押す", "8. ⑧『はい』を押す", "9. ⑨データが読み込まれたか確認する", "5. ⑤『SD』を押し、読み込み元をSDに切り替える", "6. ⑥対象の実装データを選択する", "10. データのノズル配置通りにノズルをチェンジャにセットする", "7. ⑦『SD⇒マシン』を押し、データのロードを行う" ], "WorkPoints": [ "WX_**_#_#_LANP_CHECK*はヘッド・#は供給部構成 ⇒ 設備に合わせて選択する事(例) WX_0303_T46F17_T46F17_LANP_CHECK", "SD-EJM9D05-012参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "PIP照明確認2", "WorkItems": [ "1. ①『生産データ』を押す", "2. ②『フィーダ』を押す", "3. ③『ティーチング』を押す", "4. ④『部品選択』を押す", "6. ⑥『設定』を押す", "7. ⑦『仮想吸着』を押す", "8. ⑧『ESC』を押す", "9. ⑨『吸着』を押す", "11. ⑪『確認』を押す", "5. ⑤『5×20㎜PIP_JIG_OK』を選択する", "10. ⑩治具を画面指示ノズルに吸着させる" ], "WorkPoints": [ "表示されない場合はページを切換え選択する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "MTPA022851AAJIG-WORK" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "PIP照明確認3", "WorkItems": [ "1. ①『テスト』を押す", "2. ②認識結果が『ANS 100』である事を確認する", "3. ③『ESC』を押す", "4. ④『部品選択』を押す", "5. ⑤治具を取外し『はい』を押す", "6. ⑥『5×20㎜PIP_JIG_NG』を選択する", "7. ⑦『設定』を押す", "8. ⑧『仮想吸着』を押す", "9. ⑨『ESC』を押す", "10. ⑩『吸着』を押す" ], "WorkPoints": [ "指示通り認識出来ていること", "表示されない場合はページを切換え選択する" ], "Tolks": [], "InspectionNo": "WEAV-G002-A03", "InspectionItems": [ "検査表①:PIPL2.認識精度検証" ], "WorkTypes": [ "■安全作業" ], "Words": [ "WEAV-G002-A03" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ANS=100", "Method": "目視", "RecordMethod": "WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "PIP照明確認4", "WorkItems": [ "2. ②『確認』を押す", "3. ③『テスト』を押す", "4. ④認識結果が『ANS 100』で無い事を確認する", "5. ⑤『ESC』を押す", "6. ⑥『ホーム』を押す", "7. ⑦治具を取外し『はい』を押す", "1. ①治具を画面指示ノズルに吸着させる" ], "WorkPoints": [ "リード曲がり検出にてエラー表示する事" ], "Tolks": [], "InspectionNo": "WEAV-G002-A03", "InspectionItems": [ "検査表①:PIPL2.認識精度検証" ], "WorkTypes": [ "■安全作業" ], "Words": [ "MTPA022851AAJIG-WORK", "WEAV-G002-A03" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ANS≠100", "Method": "目視", "RecordMethod": "WEAV-G002-A03", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "PE結合試験器", "Size": "", "ToolOther": "", "WorkName": "抵抗試験器始業前点検1", "WorkItems": [ "1. 低抵抗試験器のプローブに劣化や損傷が無いか確認する", "■2. プローブの先端同士を接続する (ショートする)", "■3. テスト棒側のプローブにクランプメータをセットする", "4. 低抵抗試験器のPOWERを押して電源を入れる", "5. TIMERをOFFに設定する", "■6. STARTを押す", "■7. TEST CURRENTをゆっくり回して、 電流表示針が10Aになるよう設定する", "■8. クランプメータの値を読み取り記入する", "9. STOPを押す" ], "WorkPoints": [ "図2参照", "電源スイッチ、テストボタンを押す前にテストプローブの状態を確認する事", "図3参照", "全体を目視にて確認", "丸端子の抜け確認", "テスト棒の緩み確認", "図1-1", "図1-2", "図1-3", "図2", "図3", "KIKUSUI TOS-6100", "図1-1~3参照", "図7", "図4", "図5", "図6", "図4参照", "図5参照", "図4参照", "図6・7参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "■安全作業" ] }
{ "QualityItem": "使用前確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "PE結合試験器", "Size": "", "ToolOther": "", "WorkName": "抵抗試験器始業前点検2", "WorkItems": [ "1. SUBTRACTをOFF設定にする", "■3. マイナスドライバーにてSUBTRACT横のPUSH TO OFFSETを 押した時と離した時の値が同一になる様に調整する", "2. STARTを押す" ], "WorkPoints": [ "図1参照", "図1", "図2", "図4", "図3", "図2参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "■安全作業" ] }
{ "QualityItem": "使用前確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "PE結合試験器", "Size": "", "ToolOther": "", "WorkName": "抵抗試験器始業前点検3", "WorkItems": [ "■1. 丸端子を治具BOX(KMーCO 0001) 固定抵抗のナット側へ接続する", "■2. テスト棒を治具BOXの固定抵抗のボルト側へ当てる" ], "WorkPoints": [ "図1参照", "図2参照", "図1", "図2", "治具BOX KMーCO 0001", "図3", "図4", "図5", "図6", "図7" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [ "■安全作業" ], "Words": [ "■安全作業" ] }
{ "QualityItem": "使用前確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null