{ "neg": [ "外形尺寸\n变频\n器介绍\n25\n3.3.4\n框架\nD\nS2\nH\nH1\nS1\nD1\nD\nW1\nW\n单位:\nmm\n机种\nW\nW1\nH\nH1\nD\nD1\nS1\nS2\nSA3-043-37K/45KF\n330.0\n245.0\n550.0\n525.0\n275.0\n137.5\n11.0\n11.0\nSA3-043-45K/55KF\nSA3-043-55K/75KF\nSA3-043-75K/90KF\nSA3-023-22K/30KF\nSA3-023-30K/37KF\nSA3-023-37K/45KF" ], "pos": [ "端\n子\n配线\n变频\n器介绍\n46\n\n框架\nG:\nSA3-043-160K/185KF~\nSA3-043-250K/280KF,\nSA3-023-90K/110KF,\nSA3-023-110K/132KF\n\n框架\nH:\nSA3-043-280K/315K,\nSA3-043-315K/355KF\n\n直流电抗器连接\n\n制动单元连接\n注\n:\n框架\nD\n、\nE\n、\nF\n、\nG\n、\nH\n对应的变频器无内置制动单元\n,\n可选配\nBKU\n制动单元和制动电阻详见\n7.4.4\n;\n框架\nA\n、\nB\n、\nC\n对应的变频器内置制动单元可选配制动电阻。框架的说明请参考\n3.3\n节。\n\n制动电阻连接\n注:仅适用于框架\nA\n、\nB\n、\nC\n对应的变频器。框架的说明请参考\n3.3\n节。" ], "query": "框架 H 对应的变频器是否需要外接制动电阻?" }
{ "neg": [ "穿\n墙\n式安\n装说明\n变频\n器介绍\n61\n\n开孔尺寸图\n框架\nD\n框架\nE\n框架\nF\n框架\nG\n框架\nH" ], "pos": [ "端\n子\n配线\n变频\n器介绍\n46\n\n框架\nG:\nSA3-043-160K/185KF~\nSA3-043-250K/280KF,\nSA3-023-90K/110KF,\nSA3-023-110K/132KF\n\n框架\nH:\nSA3-043-280K/315K,\nSA3-043-315K/355KF\n\n直流电抗器连接\n\n制动单元连接\n注\n:\n框架\nD\n、\nE\n、\nF\n、\nG\n、\nH\n对应的变频器无内置制动单元\n,\n可选配\nBKU\n制动单元和制动电阻详见\n7.4.4\n;\n框架\nA\n、\nB\n、\nC\n对应的变频器内置制动单元可选配制动电阻。框架的说明请参考\n3.3\n节。\n\n制动电阻连接\n注:仅适用于框架\nA\n、\nB\n、\nC\n对应的变频器。框架的说明请参考\n3.3\n节。" ], "query": "框架 F 的说明在哪里可以找到?" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n287\n设定\n用户登记参数\n\n此参数组中设定的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/6\n时,不会被恢复出厂设定值。\n\n此参数组中设定的参数值为用户需要登记的参数号,被登记的参数号的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/\n6\n时,不会被恢复出厂设定值。\n\n恢复出厂值的设定请参照\n5.1.2\n参数管理部分。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n(\nP.7\n)\n,\n「顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的\n参数号为\n01-06\n,设定\n15-00=106\n。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n,\n「\n顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的参数号\n为\n01-06\n(\nP.7\n)\n,设定\n15-00=106\n。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "附录中的参数编号是如何设定的?" }
{ "neg": [ "~\n650.00mH\n按机种\n167\n05-15\nP.316\nPM\n马达\n反电势系数\n0\n~\n6500.0V/krpm\n按机种\n167\n05-16\nP.317\nPM\n马达\nZ\n相原点脉冲补\n偿量\n0\n~\n359.9\n°\n0.0\n°\n167\n05-17\nP.318\n马达\n惯量\n0\n~\n6.5000kg.m\n2\n:\n5.5K/7.5KF\n及其以下机种\n按机种\n167\n0\n~\n65.000kg.m\n2\n:\n7.5K/11KF~\n90K/110KF\n机种\n0\n~\n650.00kg.m\n2\n:\n110K/132KF\n及其以上机种\n05-18\nP.319\n负载惯量比\n0~600.0\n1.0\n168\n05-19\nP.391\n惯量辨识转速上限\n0~100%\n50%\n168\n05-20\nP.392\n惯量辨识加减速时间\n0~20.0s\n2.0s\n168" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "过激磁电流准位的默认值是多少?" }
{ "neg": [ "系统参数组\n00\n参数说明\n84\n参数组\n参数编号\n名称\n参数组\n参数编号\n名称\n04-20\nP.132\n程式运行模式第二段速\n08-18\nP.223\n保留\n04-21\nP.133\n程式运行模式第三段速\n08-19\nP.224\n保留\n04-22\nP.134\n程式运行模式第四段速\n10-19\nP.230\n加速时的\nDwell\n频率\n04-23\nP.135\n程式运行模式第五段速\n10-21\nP.232\n减速时的\nDwell\n频率\n04-24\nP.136\n程式运行模式第六段速\n10-45\nP.267\n回生回避动作选择\n04-25\nP.137\n程式运行模式第七段速\n10-46\nP.268\n回生回避动作电压\n准\n位\n04-26\nP.138\n程式运行模式第八段速\n10-47\nP.269\n减速时\nP-N\n端电压检测敏感度\n06-17\nP.261\n维护提醒功能\n10-48\nP.270\n回生回避动作频率补偿值\n06-40\nP.288\n异警代码查询\n10-49\nP.271\n回生回避电压增益系数\n06-42\nP.290\n异警资讯查询\n10-50\nP.272\n回生回避频率增益系数\n08-03\nP.225\nPID\n目标值面板给定量\n11-12\nP.401\n转矩指令\n08-16\nP.221\n保留\n14-05\nP.605\n张力设定\n08-17\nP.222\n保留\n14-45\nP.657\n线速度设定\n\n无法写入参数(\n00-03\n(P.77)\n=\n“\n1\n”\n)\n例外\n以下参数可以写入:\n参数组\n参数编号\n名称\n参数组\n参数编号\n名称\n00-03\nP.77\n参数写保护选择\n00-16\nP.79\n操作模式选择\n\n运行中也可以写入参数(\n00-03\n(P.77)\n=\n“\n2\n”\n)\n例外\n以下参数在运行中不能写入:\n参数组\n参数编号\n名称\n参数组\n参数编号\n名称\n00-00\nP.90\n机种型号\n06-41\nP.289\n异警代码显示\n00-01\nP.188\n变频器程式版本\n06-43\nP.291\n异警资讯显示\n00-11\nP.72\n载波频率\n06-44\nP.740\nE1\n00-15\nP.78\n正反转防止选择\n06-45\nP.741\nE2\n00-16\nP.79\n操作模式选择\n06-46\nP.742\nE3\n00-26\nP.125\n扩充卡\n的类型\n06-47\nP.743\nE4\n03-59\nP.585\n监视本体\n数位\n输入端子状态\n06-48\nP.744\nE5\n03-60\nP.586\n监视本体和外扩\nSlot3\n数位\n输出端子状\n态\n06-49\nP.745\nE6\n06-50\nP.746\nE7\n03-61\nP.587\n监视外扩\nSlot2&3\n数位\n输入端子状态\n06-51\nP.747\nE8\n03-62\nP.588\n监视外扩\nSlot2\n数位\n输出端子状态\n06-52\nP.748\nE9\n06-01\nP.22\n失速防止动作\n准\n位\n06-53\nP.749\nE10\n06-08\nP.155\n过转矩检出\n准\n位\n06-54\nP.750\nE11\n06-11\nP.160\n再启动时失速\n准\n位\n06-55\nP.751\nE12\n06-21\nP.705\n低电压\n准\n位\n06-56\nP.752\nE1\n异警时的输出频率\n06-22\nP.706\n回生制动动作\n准\n位\n06-57\nP.753\nE1\n异警时的输出电流\n06-23\nP.707\n电压失速\n准\n位\n06-58\nP.754\nE1\n异警时的输出电压\n06-26\nP.710\n电解电容寿命检测结果\n06-59\nP.755\nE1\n异警时的温升累计率\n06-27" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "如何设定回生回避动作选择参数?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n352\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n10-33\nP.273\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n245\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:\n有不足电压回避\n(\n出现电压不足停电时\n,\n变频\n器减速停止)\n12\n:\n有不足电压回避\n(\n出现电压不足停电时\n,\n变频\n器减速停止。停电减速中恢复再加速)\n10-34\nP.274\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n245\n10-35\nP.275\n减速处理开始频率\n0\n~\n120.00Hz\n:\n输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n245\n99999\n:\n从输出频率-\n10-34\n(\nP.274\n)开始减速\n10-36\nP.276\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n245\n10-37\nP.277\n停电时减速时间\n2\n0\n~\n360.00s//0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的\n设定频率以下的减速时间\n99999\n245\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减\n速时间\n10-38\nP.278\n停电时减速时间切换频率\n0\n~\n650.00Hz\n50.00Hz\n245\n10-39\nP.279\nUV\n回避电压增益\n0\n~\n200.0%\n100.0%\n245\n10-40\nP.700\nVF\n分离的电压源\n0\n:数位给定\n10-41\n(\nP.701\n)\n0\n246\n1\n:\n类比\n量给定或\nHDI\n脉冲给定\n10-41\nP.701\nVF\n分离的电压数位设定\n50Hz/60Hz\n系统设定时:\n0\n~\n440.00V/0~220.00V\n按电压\n246\n10-42\nP.702\nVF\n分离的电压加速时间\n0\n~\n1000.0s\n0.0s\n246\n10-43\nP.703\nVF\n分离的电压减速时间\n0\n~\n1000.0s\n0.0s\n246\n10-44\nP.704\nVF\n分离停机方式选择\n0\n:频率\n/\n电压独立减至\n0\n0\n246\n1\n:电压减为\n0\n后频率再减\n10-45\nP.267\n回生回避动作选择\n0\n:无回生回避功能\n0\n247\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:\n运转中回生回避功能有效\n(\n手动模式\n,\n动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)\n设定)\n12\n:\n仅在恒速时有回生回避\n(\n手动模式\n,\n动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设\n定\n10-46\nP.268\n回生回避动作电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n247\n310\n~\n800V\n:\n440V\n机种\n760V\n247" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "停电时减速时间的范围是多少?" }
{ "neg": [ "系统参数组\n00\n参数说明\n84\n参数组\n参数编号\n名称\n参数组\n参数编号\n名称\n04-20\nP.132\n程式运行模式第二段速\n08-18\nP.223\n保留\n04-21\nP.133\n程式运行模式第三段速\n08-19\nP.224\n保留\n04-22\nP.134\n程式运行模式第四段速\n10-19\nP.230\n加速时的\nDwell\n频率\n04-23\nP.135\n程式运行模式第五段速\n10-21\nP.232\n减速时的\nDwell\n频率\n04-24\nP.136\n程式运行模式第六段速\n10-45\nP.267\n回生回避动作选择\n04-25\nP.137\n程式运行模式第七段速\n10-46\nP.268\n回生回避动作电压\n准\n位\n04-26\nP.138\n程式运行模式第八段速\n10-47\nP.269\n减速时\nP-N\n端电压检测敏感度\n06-17\nP.261\n维护提醒功能\n10-48\nP.270\n回生回避动作频率补偿值\n06-40\nP.288\n异警代码查询\n10-49\nP.271\n回生回避电压增益系数\n06-42\nP.290\n异警资讯查询\n10-50\nP.272\n回生回避频率增益系数\n08-03\nP.225\nPID\n目标值面板给定量\n11-12\nP.401\n转矩指令\n08-16\nP.221\n保留\n14-05\nP.605\n张力设定\n08-17\nP.222\n保留\n14-45\nP.657\n线速度设定\n\n无法写入参数(\n00-03\n(P.77)\n=\n“\n1\n”\n)\n例外\n以下参数可以写入:\n参数组\n参数编号\n名称\n参数组\n参数编号\n名称\n00-03\nP.77\n参数写保护选择\n00-16\nP.79\n操作模式选择\n\n运行中也可以写入参数(\n00-03\n(P.77)\n=\n“\n2\n”\n)\n例外\n以下参数在运行中不能写入:\n参数组\n参数编号\n名称\n参数组\n参数编号\n名称\n00-00\nP.90\n机种型号\n06-41\nP.289\n异警代码显示\n00-01\nP.188\n变频器程式版本\n06-43\nP.291\n异警资讯显示\n00-11\nP.72\n载波频率\n06-44\nP.740\nE1\n00-15\nP.78\n正反转防止选择\n06-45\nP.741\nE2\n00-16\nP.79\n操作模式选择\n06-46\nP.742\nE3\n00-26\nP.125\n扩充卡\n的类型\n06-47\nP.743\nE4\n03-59\nP.585\n监视本体\n数位\n输入端子状态\n06-48\nP.744\nE5\n03-60\nP.586\n监视本体和外扩\nSlot3\n数位\n输出端子状\n态\n06-49\nP.745\nE6\n06-50\nP.746\nE7\n03-61\nP.587\n监视外扩\nSlot2&3\n数位\n输入端子状态\n06-51\nP.747\nE8\n03-62\nP.588\n监视外扩\nSlot2\n数位\n输出端子状态\n06-52\nP.748\nE9\n06-01\nP.22\n失速防止动作\n准\n位\n06-53\nP.749\nE10\n06-08\nP.155\n过转矩检出\n准\n位\n06-54\nP.750\nE11\n06-11\nP.160\n再启动时失速\n准\n位\n06-55\nP.751\nE12\n06-21\nP.705\n低电压\n准\n位\n06-56\nP.752\nE1\n异警时的输出频率\n06-22\nP.706\n回生制动动作\n准\n位\n06-57\nP.753\nE1\n异警时的输出电流\n06-23\nP.707\n电压失速\n准\n位\n06-58\nP.754\nE1\n异警时的输出电压\n06-26\nP.710\n电解电容寿命检测结果\n06-59\nP.755\nE1\n异警时的温升累计率\n06-27" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "回生回避电压增益系数的范围是多少?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n352\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n10-33\nP.273\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n245\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:\n有不足电压回避\n(\n出现电压不足停电时\n,\n变频\n器减速停止)\n12\n:\n有不足电压回避\n(\n出现电压不足停电时\n,\n变频\n器减速停止。停电减速中恢复再加速)\n10-34\nP.274\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n245\n10-35\nP.275\n减速处理开始频率\n0\n~\n120.00Hz\n:\n输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n245\n99999\n:\n从输出频率-\n10-34\n(\nP.274\n)开始减速\n10-36\nP.276\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n245\n10-37\nP.277\n停电时减速时间\n2\n0\n~\n360.00s//0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的\n设定频率以下的减速时间\n99999\n245\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减\n速时间\n10-38\nP.278\n停电时减速时间切换频率\n0\n~\n650.00Hz\n50.00Hz\n245\n10-39\nP.279\nUV\n回避电压增益\n0\n~\n200.0%\n100.0%\n245\n10-40\nP.700\nVF\n分离的电压源\n0\n:数位给定\n10-41\n(\nP.701\n)\n0\n246\n1\n:\n类比\n量给定或\nHDI\n脉冲给定\n10-41\nP.701\nVF\n分离的电压数位设定\n50Hz/60Hz\n系统设定时:\n0\n~\n440.00V/0~220.00V\n按电压\n246\n10-42\nP.702\nVF\n分离的电压加速时间\n0\n~\n1000.0s\n0.0s\n246\n10-43\nP.703\nVF\n分离的电压减速时间\n0\n~\n1000.0s\n0.0s\n246\n10-44\nP.704\nVF\n分离停机方式选择\n0\n:频率\n/\n电压独立减至\n0\n0\n246\n1\n:电压减为\n0\n后频率再减\n10-45\nP.267\n回生回避动作选择\n0\n:无回生回避功能\n0\n247\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:\n运转中回生回避功能有效\n(\n手动模式\n,\n动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)\n设定)\n12\n:\n仅在恒速时有回生回避\n(\n手动模式\n,\n动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设\n定\n10-46\nP.268\n回生回避动作电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n247\n310\n~\n800V\n:\n440V\n机种\n760V\n247" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "如何设定停电停止方式选择参数?" }
{ "neg": [ "应用参数组\n10\n参数说明\n248\n5.11.15\n过\n激磁\n减速功能\n\n过\n激磁\n减速通过增加减速停止时的磁通来增加\n马达\n端的损耗,从而可以在无制动电阻的情况下缩短减速时间。\n参数\n名称\n出厂值\n设定范围\n内容\n10-51\nP.264\n过\n激磁\n减速选择\n0\n0\n无过\n激磁\n减速功能\n1\n有过\n激磁\n减速功能\n10-52\nP.265\n过\n激磁\n电流\n准\n位\n150.0%\n0\n~\n200.0%\n过\n激磁\n减速时,输出电流在设定\n准\n位以上,过\n激磁\n增益将自动\n降低\n10-53\nP.266\n过\n激磁\n增益\n1.10\n1.00\n~\n1.40\n---\n设定\n过\n激磁\n减速功能\n\n过\n激磁\n减速(\n10-51(P.264)=\n“\n1\n”\n)\n过\n激磁\n控制可以抑制\nP-N\n端\n电压的上升,过\n激磁\n增益越大,抑制效果越明显。\n过\n激磁\n减速过程中出现电压失速时,需延长减速时间或者提高过\n激磁\n增益\n10-53(P.266)\n。\n过\n激磁\n减速过程中出现电流失速时,需延长减速时间或者降低过\n激磁\n增益\n10-53(P.266)\n。\n注\n:\n1.\n再生能量在\n马达\n内部主要以热量的形式被消耗\n,\n因此如果频繁的使用过\n激磁\n减速功能\n,\n将会导致\n马达\n内部的温度\n上升。\n2.\n在过\n激磁\n减速时输入运转指令,则过\n激磁\n减速功能将取消,变频器重新加速至设定频率。\n3.\n使用\nPM\n马达\n时不能使用过\n激磁\n减速功能。\n5.11.16\nPM\n马达\n起动时短路制动功能\n\n该参数用于\nPM\n用无\nPG\n向量控制模式,\n马达\n控制模式的设定请参考参数\n00-21(\nP.300\n),00-22(\nP.370\n)\n。\n参数\n名称\n出厂值\n设定范围\n内容\n10-54\nP.362\nP\nM\n马达\n起动时短路制\n动时间\n0.0s\n0.0\n~\n60.0s\n---\n\n设定起动时使短路制动动作的时间。利用\nIGBT\n的切换使三相短接,产生\n马达\n的制动转矩,使自由运行中的\nPM\n马\n达\n停止后再次起动时使用。\n注:短路制动并不能防止\nPM\n马达\n在外力的作用下旋转。此时请使用直流制动。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "过激磁增益的设定范围是什么?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n352\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n10-33\nP.273\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n245\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:\n有不足电压回避\n(\n出现电压不足停电时\n,\n变频\n器减速停止)\n12\n:\n有不足电压回避\n(\n出现电压不足停电时\n,\n变频\n器减速停止。停电减速中恢复再加速)\n10-34\nP.274\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n245\n10-35\nP.275\n减速处理开始频率\n0\n~\n120.00Hz\n:\n输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n245\n99999\n:\n从输出频率-\n10-34\n(\nP.274\n)开始减速\n10-36\nP.276\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n245\n10-37\nP.277\n停电时减速时间\n2\n0\n~\n360.00s//0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的\n设定频率以下的减速时间\n99999\n245\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减\n速时间\n10-38\nP.278\n停电时减速时间切换频率\n0\n~\n650.00Hz\n50.00Hz\n245\n10-39\nP.279\nUV\n回避电压增益\n0\n~\n200.0%\n100.0%\n245\n10-40\nP.700\nVF\n分离的电压源\n0\n:数位给定\n10-41\n(\nP.701\n)\n0\n246\n1\n:\n类比\n量给定或\nHDI\n脉冲给定\n10-41\nP.701\nVF\n分离的电压数位设定\n50Hz/60Hz\n系统设定时:\n0\n~\n440.00V/0~220.00V\n按电压\n246\n10-42\nP.702\nVF\n分离的电压加速时间\n0\n~\n1000.0s\n0.0s\n246\n10-43\nP.703\nVF\n分离的电压减速时间\n0\n~\n1000.0s\n0.0s\n246\n10-44\nP.704\nVF\n分离停机方式选择\n0\n:频率\n/\n电压独立减至\n0\n0\n246\n1\n:电压减为\n0\n后频率再减\n10-45\nP.267\n回生回避动作选择\n0\n:无回生回避功能\n0\n247\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:\n运转中回生回避功能有效\n(\n手动模式\n,\n动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)\n设定)\n12\n:\n仅在恒速时有回生回避\n(\n手动模式\n,\n动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设\n定\n10-46\nP.268\n回生回避动作电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n247\n310\n~\n800V\n:\n440V\n机种\n760V\n247" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "怎样设定停电时减速时间1和时间2?" }
{ "neg": [ "保护参数组\n06\n参数说明\n178\n\n06-07(P.263)=1\n,固定额定电流,会根据\nIGBT\n模组温度来自动降低运转载波频率,避免\nIGBT\n模组温度过热。\n规律如下:当\nIGBT\n模组温度升到\n80\n°\nC\n左右时,自动降低载波频率到上图中\n100%\n额定时的载波值;当\nIGBT\n模组\n温度降至\n70\n°\nC\n左右时,运转载波自动上升到设定载波值\n(00-11(\nP.37\n))\n。\n(特殊机种除外)\n特殊机种:\n机种\n升高到温度(\n°\nC\n)\n降低到温度(\n°\nC\n)\n043-110K/132KF\n95\n80\n043-250K/280KF\n91\n78\n023-55K/75KF\n88\n75" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "如何设定降载波保护?" }
{ "neg": [ "应用参数组\n10\n参数说明\n247\n5.11.14\n回生回避功能\n\n当变频器负载惯性较大时,减速或其他过程中\nPN\n电压容易受回生能量影响而上升,报\nOV\n异警。该功能通过调整\n变频器输出频率和输出电压,来维持变频器\nPN\n电压在固定\n准\n位,防止\nPN\n电压上升到\nOV\n准\n位。\n参数\n名称\n出厂值\n设定范围\n内容\n10-45\nP.267\n回生回避动作选择\n0\n0\n无回生回避功能\n1\n运转中回生回避功能有效\n(\n自动模式\n,\n动作时加减速自动计算\n)\n2\n仅在恒速时有回生回避(自动模式,动作时加减速自动计算)\n11\n运转中回生回避功能有效(手动模式,动作时加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\n12\n仅在恒速时有回生回避(手动模式,动作时加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\n10-46\nP.268\n回生回避动作电压\n准\n位\n380V\n155\n~\n400V\n220V\n机种\n760V\n310\n~\n800V\n440V\n机种\n10-47\nP.269\n减速时\nP-N\n端电压检测\n敏感度\n0\n0\n根据\nP-N\n端电压变化率防止再生回避无效\n1\n~\n5\n检测\nP-N\n端电压变化率设定灵敏度,数位越大灵敏度越高\n10-48\nP.270\n回生回避动作频率补偿\n值\n6.00Hz\n0\n~\n10.00Hz\n设定回生回避频率补偿的限定\n99999\n无频率限定\n10-49\nP.271\n回生回避电压增益系数\n100.0%\n0\n~\n400.0%/\n0~40.00%\n设定范围和\n10-45\n(\nP.267\n)\n的设定值有关\n,\n10-45\n(\nP.267\n)\n>10\n,\n设定范围为\n0~40.00%\n,\n0-45\n(\nP.267\n)\n<10\n,设定范围\n为\n0~400.0%\n。\n调整再生回避动作时的应回应速度。增大设定值后,将改善\n对\nP-N\n端电压变化的回应。输出频率有可能会不稳定。即使减小\n10-49\n(\nP.271\n)\n的设定值\n,\n还是无法减少振动时\n,\n请减小\n10-50\n(\nP.272\n)的设定值。\n10-50\nP.272\n回生回避频率增益系数\n100.0%\n0\n~\n400.0%/\n0~40.00%\n设定\n回生回避功能\n\n回生回避功能的作用\n:\n在\nP-N\n端\n电压上升\n,\n再生能量大的情况下\n,\n导致\nP-N\n端\n电压过高\n,\n变频器报\nOV\n异警\n。\n回生\n回避功能就是在回升电压超出\n准\n位时\n,\n提高变频器的输出频率来降低\nP-N\n端电压\n,\n避免变频器报\nOV\n异警\n(\n如下图\n)\n。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n308\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.263\n06-07\n降载波保护设定\n0\n:定载波频率,并依照设定载波限制负载电流\n0\n175\n1\n:定额定电流,并依照负载电流及温度限制载波\nP.264\n10-51\n过\n激磁\n减速选择\n0\n:无过\n激磁\n减速功能\n0\n247\n1\n:有过\n激磁\n减速功能\nP.265\n10-52\n过\n激磁\n电流\n准\n位\n0\n~\n200.0%\n150.0%\n247\nP.266\n10-53\n过\n激磁\n增益\n1.00\n~\n1.40\n1.10\n247\nP.267\n10-45\n回生回避动作选择\n0\n:无回生回避功能\n0\n246\n1\n:运转中回生回避功能有效(自动模式,动作时\n加减速自动计算)\n2\n:仅在恒速时有回生回避(自动模式,动作时加\n减速自动计算)\n11\n:运转中回生回避功能有效(手动模式,动作时\n加减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定\n)\n12\n:仅在恒速时有回生回避(手动模式,动作时加\n减速由\n10-49\n(\nP.271\n)和\n10-50\n(\nP.272\n)设定)\nP.268\n10-46\n回生回避动电压\n准\n位\n155\n~\n400V\n:\n220V\n机种\n380V\n246\n310\n~\n800V\n:\n440V\n机种\n760V\n246\nP.269\n10-47\n减速时\nP-N\n端电压检测敏\n感度\n0\n:根据\nP-N\n端电压变化率防止再生回避无效\n0\n246\n1\n~\n5\n:检测\nP-N\n端电压变化率设定灵敏度,数位越\n大灵敏度越高\nP.270\n10-48\n回生回避动作频率补偿值\n0\n~\n10.00Hz\n:\n设定回生回避频率补偿的限定\n6.00Hz\n246\n99999\n:无频率限定\nP.271\n10-49\n回生回避电压增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.272\n10-50\n回生回避频率增益系数\n0\n~\n400.0%/0~40.00%\n100.0%\n246\nP.273\n10-33\n停电停止方式选择\n0\n:无停电时减速停车功能\n0\n244\n1\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止)\n2\n:无不足电压回避(出现电压不足停电时,变频\n器减速停止。停电减速中恢复再加速)\n11\n:有不足电压回避(出现电压不足停电时,变\n频器减速停止)\n12\n:有不足电压回避(出现电压不足停电时,变\n器减速停止。停电减速中恢复再加速)\nP.274\n10-34\n开始减速时减算频率\n0\n~\n20.00Hz\n3.00Hz\n244\nP.275\n10-35\n减速处理开始频率\n0\n~\n120.00Hz\n:输出频率\n≥\n10-35\n(\nP.275\n)时,从\n输出频率-\n10-34(P.274)\n开始减速;输出频率<\n10-35\n(\nP.275\n)时,从输出频率开始减速\n50.00Hz\n244\n99999\n:从输出频率-\n10-34\n(\nP.274\n)开始减速\nP.276\n10-36\n停电时减速时间\n1\n0\n~\n360.00s/0~3600.0s\n5.00s\n244\nP.277\n10-37\n停电时减速时间\n2\n0\n~\n360.00s/0~3600.0s\n:\n设定\n10-38\n(\nP.278\n)\n的设\n定频率以下的减速时间\n99999\n244\n99999\n:设定到\n10-38\n(\nP.278\n)的设定频率的减速\n时间" ], "query": "回生回避动作频率补偿值的范围是多少?" }
{ "neg": [ "端\n子\n配线\n变频\n器介绍\n44\n3.7\n端子配线\nSOURCE\nSINK\nSW5\n4-20mA\n0-10V\n0-10V\n0-20mA\n0-20mA\n0-10V\nSW4\nOPEN\nSW3\nSW2\nSW6\nSW1\n4~20mA\n0-10V\nON\nOFF\n120\n注:\n1.\nR1\n,\nS1\n端子仅适用\nD\n~\nH\n框架,具体配线请参考\n3.7.5\n节。\n2.\nRFI\n滤波器的设定请参照\n3.7.4\n节。\n3.\n+/P\n和\nPR\n之间的制动电阻接线方法只针对框架\nA\n、\nB\n、\nC\n。\n对于框架\nD\n、\nE\n、\nF\n、\nG\n、\nH\n制动单元接在\n(+/P)-(-N)\n之\n间,详细内容请参考\n3.7.1\n节。\n4.\n+/P\n和\nP1\n之间可以选配外加直流电抗器,不用的情况下,直接短接。\n5.\n外加直流电抗器时,必须拆除\n+/P\n、\nP1\n间的短路片,电抗器选型请参考\n3.6.4\n节。\n6.\nHDO\n配线请参考\n5.3.9\n节。" ], "pos": [ "端子\n配线\n变频\n器介绍\n51\n3.7.5\n关于\nP-N\n端\n供电\n\n适用于\nD~H\n框架的操作说明\n1.\nSeparate\npower\nsupply\n出厂\n预设\n状态为\nOFF(\n如下图设定\n),\n此时变频器内部交流接触器由\nR/L1,S/L2,T/L3\n供电驱动\n.\nOFF\nON\n2.\n当变频器通过\nP-N\n端\n(+/P,-/N)\n供电时\n,\n需要设置\nSeparate\npower\nsupply\n状态为\nON(\n如下图设定\n)\n,\n同时\n,\n需在端子\nR1\n,\nS1\n输入\n220Vac(220V\n机种\n)/440Vac(440V\n机种\n)\n。当变频器直流通电后\n[\n端子\nR1\n,\nS1\n未输入\n220Vac(220V\n机\n种\n)/440Vac(440V\n机种\n)]\n,\n数位\n操作器产生错误码\n”\nrAE\n”\n。\nOFF\nON\n3.\n当作为共\nP-N\n端\n(\n入力\nR/L1,S/L2,T/L3\n电源持续供电\n)\n时,\nSeparate\npower\nsupply\n需维持出厂\n预设\n状态\nOFF\n。\n\nNOTE\n共\nP-N\n端\n应用需要驱动器的功率数皆相同,如果不相同功率数的驱动器要共\nP-N\n端\n应用,请来电\n洽询\n。\n(DEFAULT)\nOFF\nON\nR1\nS1\nSEPARATE POWER SUPPLY\nAC INPUT\n\n可以进行支持多种直流供电方式\n,\n适合于不间断电源\n(UPS/EPS),\nP-N\n端\n供电等多种场合" ], "query": "如果我需要使用直流供电方式,该如何配置变频器?" }
{ "neg": [ "附录\n二:\n异常代码\n表\n附录\n363\n代码\n显示幕上的显示\n原因\n处理方法\nHDC\n硬体检测线路\n异常\n硬体检测线路出现故障\n请送厂检修\nADE\n三相电流采样\n线路异常\n三相电流采样线路出现故障\n请送厂检修\nEbE1\n扩充卡\nSLOT1\n异\n常\n变频器自动侦测的首次结果与下次\n结果不一致\n检查扩展板连接情况\nEbE2\n扩充卡\nSLOT2\n异\n常\n变频器自动侦测的首次结果与下次\n结果不一致\n检查扩展板连接情况\nEbE3\n扩充卡\nSLOT3\n异\n常\n变频器自动侦测的首次结果与下次\n结果不一致\n检查扩展板连接情况\n注\n1\n:未排除故障原因前,请勿重复\n送电\n开启。" ], "pos": [ "端子\n配线\n变频\n器介绍\n51\n3.7.5\n关于\nP-N\n端\n供电\n\n适用于\nD~H\n框架的操作说明\n1.\nSeparate\npower\nsupply\n出厂\n预设\n状态为\nOFF(\n如下图设定\n),\n此时变频器内部交流接触器由\nR/L1,S/L2,T/L3\n供电驱动\n.\nOFF\nON\n2.\n当变频器通过\nP-N\n端\n(+/P,-/N)\n供电时\n,\n需要设置\nSeparate\npower\nsupply\n状态为\nON(\n如下图设定\n)\n,\n同时\n,\n需在端子\nR1\n,\nS1\n输入\n220Vac(220V\n机种\n)/440Vac(440V\n机种\n)\n。当变频器直流通电后\n[\n端子\nR1\n,\nS1\n未输入\n220Vac(220V\n机\n种\n)/440Vac(440V\n机种\n)]\n,\n数位\n操作器产生错误码\n”\nrAE\n”\n。\nOFF\nON\n3.\n当作为共\nP-N\n端\n(\n入力\nR/L1,S/L2,T/L3\n电源持续供电\n)\n时,\nSeparate\npower\nsupply\n需维持出厂\n预设\n状态\nOFF\n。\n\nNOTE\n共\nP-N\n端\n应用需要驱动器的功率数皆相同,如果不相同功率数的驱动器要共\nP-N\n端\n应用,请来电\n洽询\n。\n(DEFAULT)\nOFF\nON\nR1\nS1\nSEPARATE POWER SUPPLY\nAC INPUT\n\n可以进行支持多种直流供电方式\n,\n适合于不间断电源\n(UPS/EPS),\nP-N\n端\n供电等多种场合" ], "query": "在什么情况下会产生错误码 \"rAE\"?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n122\n例\n8\n:此范例是反斜率设定的应用。业界经常会使用一些感测器来做压力、温度、流量等的控制,而这些感测器有\n些是当压力大或流量高时,所输出的信号是\n10V\n;而这个讯息就是要交流\n马达\n驱动器减速或停止的命令,范例八的\n设定恰好满足此类的应用。\n例\n9\n:此范例是所有电位器应用的集大成,加上正转与反转区的应用可以很容易的与系统结合做各种复杂的应用。" ], "pos": [ "端子\n配线\n变频\n器介绍\n51\n3.7.5\n关于\nP-N\n端\n供电\n\n适用于\nD~H\n框架的操作说明\n1.\nSeparate\npower\nsupply\n出厂\n预设\n状态为\nOFF(\n如下图设定\n),\n此时变频器内部交流接触器由\nR/L1,S/L2,T/L3\n供电驱动\n.\nOFF\nON\n2.\n当变频器通过\nP-N\n端\n(+/P,-/N)\n供电时\n,\n需要设置\nSeparate\npower\nsupply\n状态为\nON(\n如下图设定\n)\n,\n同时\n,\n需在端子\nR1\n,\nS1\n输入\n220Vac(220V\n机种\n)/440Vac(440V\n机种\n)\n。当变频器直流通电后\n[\n端子\nR1\n,\nS1\n未输入\n220Vac(220V\n机\n种\n)/440Vac(440V\n机种\n)]\n,\n数位\n操作器产生错误码\n”\nrAE\n”\n。\nOFF\nON\n3.\n当作为共\nP-N\n端\n(\n入力\nR/L1,S/L2,T/L3\n电源持续供电\n)\n时,\nSeparate\npower\nsupply\n需维持出厂\n预设\n状态\nOFF\n。\n\nNOTE\n共\nP-N\n端\n应用需要驱动器的功率数皆相同,如果不相同功率数的驱动器要共\nP-N\n端\n应用,请来电\n洽询\n。\n(DEFAULT)\nOFF\nON\nR1\nS1\nSEPARATE POWER SUPPLY\nAC INPUT\n\n可以进行支持多种直流供电方式\n,\n适合于不间断电源\n(UPS/EPS),\nP-N\n端\n供电等多种场合" ], "query": "这篇文章提到的多种直流供电方式都适合哪些场合?" }
{ "neg": [ "变频\n器的操作模式\n基本\n操作\n71\n4.2.4\n频率设定模式的操作流程图,使用\nPU301\n操作键盘\n或\n>\n或\nWRITE\nWRITE\nWRITE\n>\n>\n>\n<\n>\n>\n<\n闪烁\n闪烁\n闪烁\nMON\nPU\nEXT\nNET\nPLC\nHz\nA\nV\n.\n6\n0\n0\n1\n1\n0\n0\n6\n.\nV\nA\nHz\nPLC\nNET\nEXT\nPU\nMON\n1\n0\n0\n6\n0\n.\nV\nA\nHz\nPLC\nNET\nEXT\nPU\nMON\nMON\nPU\nEXT\nNET\nPLC\nHz\nA\nV\n.\n0\n6\n0\n0\n0\n0\n0\n0\n6\n.\nV\nA\nHz\nPLC\nNET\nEXT\nPU\nMON\n注:\n1.\n当变频器在运转状态下操作键盘旋钮修改频率。\n2.\n频率设定模式下,指示灯\nHz\n会亮,指示灯\nMON\n不会亮。\n3.\nPU\n设定频率时,频率的设定值不能大于上限频率,当需要高频运转时,需先修改上限频率。\n4.2.5\n参数设定模式的操作流程图,使用\nPU301\n操作键盘\nMON\nPU\nEXT\nNET\nPLC\nHz\nA\nV\n0\n1\n-\n0\n2\nMON\nPU\nEXT\nNET\nPLC\nHz\nA\nV\n.\n1\n2\n0\n2\n0\n闪烁\n闪烁\n或\n>\n<\n>\n>\n>\n>\nESC\nREAD\nREAD\nWRITE\nMON\nPU\nEXT\nNET\nPLC\nHz\nA\nV\n0\n1\n-\n0\n3\n0\n2\n0\n2\n1\n.\nV\nA\nHz\nPLC\nNET\nEXT\nPU\nMON\nMON\nPU\nEXT\nNET\nPLC\nHz\nA\nV\n.\n1\n2\n0\n0\n0\n2\n0\n-\n1\n0\nV\nA\nHz\nPLC\nNET\nEXT\nPU\nMON\n注:参数设定模式下,指示灯\nHz\n与指示灯\nMON\n不会亮。写参数值用\nWRITE\n键。\n闪烁\n闪烁\n闪烁\n闪烁\n闪烁" ], "pos": [ "端子\n配线\n变频\n器介绍\n51\n3.7.5\n关于\nP-N\n端\n供电\n\n适用于\nD~H\n框架的操作说明\n1.\nSeparate\npower\nsupply\n出厂\n预设\n状态为\nOFF(\n如下图设定\n),\n此时变频器内部交流接触器由\nR/L1,S/L2,T/L3\n供电驱动\n.\nOFF\nON\n2.\n当变频器通过\nP-N\n端\n(+/P,-/N)\n供电时\n,\n需要设置\nSeparate\npower\nsupply\n状态为\nON(\n如下图设定\n)\n,\n同时\n,\n需在端子\nR1\n,\nS1\n输入\n220Vac(220V\n机种\n)/440Vac(440V\n机种\n)\n。当变频器直流通电后\n[\n端子\nR1\n,\nS1\n未输入\n220Vac(220V\n机\n种\n)/440Vac(440V\n机种\n)]\n,\n数位\n操作器产生错误码\n”\nrAE\n”\n。\nOFF\nON\n3.\n当作为共\nP-N\n端\n(\n入力\nR/L1,S/L2,T/L3\n电源持续供电\n)\n时,\nSeparate\npower\nsupply\n需维持出厂\n预设\n状态\nOFF\n。\n\nNOTE\n共\nP-N\n端\n应用需要驱动器的功率数皆相同,如果不相同功率数的驱动器要共\nP-N\n端\n应用,请来电\n洽询\n。\n(DEFAULT)\nOFF\nON\nR1\nS1\nSEPARATE POWER SUPPLY\nAC INPUT\n\n可以进行支持多种直流供电方式\n,\n适合于不间断电源\n(UPS/EPS),\nP-N\n端\n供电等多种场合" ], "query": "在使用UPS或EPS时,应该如何配置变频器的供电方式?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n338\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-33\nP.559\n数位输入端子\nM10(Slot2)\n同\n03-00\n(P.83)\n99999\n149\n03-34\nP.560\n数位输入端子\nM11(Slot2)\n同\n03-00\n(P.83)\n99999\n14\n9\n03-35\nP.561\n数位输入端子\nM12(Slot2)\n同\n03-00\n(P.83)\n99999\n149\n03-36\nP.562\n数位输入端子\nM13(Slot2)\n同\n03-00\n(P.83)\n99999\n14\n9\n03-37\nP.563\n数位输入端子\nM14(Slot2)\n同\n03-00\n(P.83)\n99999\n149\n03-38\nP.564\n数位输入端子\nM15(Slot2)\n同\n03-00\n(P.83)\n99999\n149\n03-41\nP.567\n外扩数位输入端子正反逻辑\n(Slot2&3)\n0\n~\n65535\n0\n150\n03-42\nP.568\n数位输出端子\nA10(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-43\nP.569\n数位输出端子\nA11(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-44\nP.570\n数位输出端子\nA12(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-45\nP.571\n数位输出端子\nA13(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-46\nP.572\n数位输出端子\nA14(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-47\nP.573\n数位输出端子\nA15(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-48\nP.574\n数位输出端子\nA16(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-49\nP.575\n数位输出端子\nA17(Slot3)\n同\n03-10(P.40)\n99999\n150\n03-50\nP.576\n数位输出端子\nA10(Slot2)\n同\n03-10(P.40)\n99999\n15\n1\n03-51\nP.577\n数位输出端子\nA11(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-52\nP.578\n数位输出端子\nA12(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-53\nP.579\n数位输出端子\nA13(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-54\nP.580\n数位输出端子\nA14(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-55\nP.581\n数位输出端子\nA15(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-56\nP.582\n数位输出端子\nA16(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-57\nP.583\n数位输出端子\nA17(Slot2)\n同\n03-10(P.40)\n99999\n151\n03-58\nP.584\n外扩数位输出端子正反逻辑\n(Slot2)\n0\n~\n255\n0\n151\n03-59\nP.585\n监视本体数位输入端子状态\n唯读\n唯读\n152\n03-60\nP.586\n监视本体和外扩\nSlot3\n数位输\n出端子状态\n唯读\n唯读\n152\n03-61\nP.587\n监视外\n扩\nSlot2&\n3\n数位输入端\n子状态\n唯读\n唯读\n152\n03-62\nP.588\n监视外扩\nSlot2\n数位输出端子" ], "pos": [ "端子\n配线\n变频\n器介绍\n51\n3.7.5\n关于\nP-N\n端\n供电\n\n适用于\nD~H\n框架的操作说明\n1.\nSeparate\npower\nsupply\n出厂\n预设\n状态为\nOFF(\n如下图设定\n),\n此时变频器内部交流接触器由\nR/L1,S/L2,T/L3\n供电驱动\n.\nOFF\nON\n2.\n当变频器通过\nP-N\n端\n(+/P,-/N)\n供电时\n,\n需要设置\nSeparate\npower\nsupply\n状态为\nON(\n如下图设定\n)\n,\n同时\n,\n需在端子\nR1\n,\nS1\n输入\n220Vac(220V\n机种\n)/440Vac(440V\n机种\n)\n。当变频器直流通电后\n[\n端子\nR1\n,\nS1\n未输入\n220Vac(220V\n机\n种\n)/440Vac(440V\n机种\n)]\n,\n数位\n操作器产生错误码\n”\nrAE\n”\n。\nOFF\nON\n3.\n当作为共\nP-N\n端\n(\n入力\nR/L1,S/L2,T/L3\n电源持续供电\n)\n时,\nSeparate\npower\nsupply\n需维持出厂\n预设\n状态\nOFF\n。\n\nNOTE\n共\nP-N\n端\n应用需要驱动器的功率数皆相同,如果不相同功率数的驱动器要共\nP-N\n端\n应用,请来电\n洽询\n。\n(DEFAULT)\nOFF\nON\nR1\nS1\nSEPARATE POWER SUPPLY\nAC INPUT\n\n可以进行支持多种直流供电方式\n,\n适合于不间断电源\n(UPS/EPS),\nP-N\n端\n供电等多种场合" ], "query": "如果我想了解共P-N端应用的详细信息,应该如何咨询?" }
{ "neg": [ "穿\n墙\n式安\n装说明\n变频\n器介绍\n61\n\n开孔尺寸图\n框架\nD\n框架\nE\n框架\nF\n框架\nG\n框架\nH" ], "pos": [ "端子\n配线\n变频\n器介绍\n51\n3.7.5\n关于\nP-N\n端\n供电\n\n适用于\nD~H\n框架的操作说明\n1.\nSeparate\npower\nsupply\n出厂\n预设\n状态为\nOFF(\n如下图设定\n),\n此时变频器内部交流接触器由\nR/L1,S/L2,T/L3\n供电驱动\n.\nOFF\nON\n2.\n当变频器通过\nP-N\n端\n(+/P,-/N)\n供电时\n,\n需要设置\nSeparate\npower\nsupply\n状态为\nON(\n如下图设定\n)\n,\n同时\n,\n需在端子\nR1\n,\nS1\n输入\n220Vac(220V\n机种\n)/440Vac(440V\n机种\n)\n。当变频器直流通电后\n[\n端子\nR1\n,\nS1\n未输入\n220Vac(220V\n机\n种\n)/440Vac(440V\n机种\n)]\n,\n数位\n操作器产生错误码\n”\nrAE\n”\n。\nOFF\nON\n3.\n当作为共\nP-N\n端\n(\n入力\nR/L1,S/L2,T/L3\n电源持续供电\n)\n时,\nSeparate\npower\nsupply\n需维持出厂\n预设\n状态\nOFF\n。\n\nNOTE\n共\nP-N\n端\n应用需要驱动器的功率数皆相同,如果不相同功率数的驱动器要共\nP-N\n端\n应用,请来电\n洽询\n。\n(DEFAULT)\nOFF\nON\nR1\nS1\nSEPARATE POWER SUPPLY\nAC INPUT\n\n可以进行支持多种直流供电方式\n,\n适合于不间断电源\n(UPS/EPS),\nP-N\n端\n供电等多种场合" ], "query": "变频器的适用框架是指哪些框架?需要特别注意什么?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n345\n参数\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n:\n无同位\n0\n192\n1\n:\n奇数同位检查\n2\n:\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n:仅有\nCR\n1\n192\n2\n:\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n0\n:\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n4\n192\n1\n:\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n:\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n:\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n:\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n:\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n0\n~\n10\n1\n192\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n0\n~\n999.8s\n:\n以设定值进行通讯超时检验\n99999\n192\n99999\n:不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n:报警并空转停车\n0\n192\n1\n:不报警并继续运行\n07-11\nP.34\n通讯\nEEPROM\n写入选择\n0\n:通讯模式写入参数时,写入\nRAM\n和\nEEPROM\n0\n207\n1\n:通讯模式写入参数时,只写入\nRAM\n07-15\nP.800\nCANopen\n从站地址\n0\n~\n127\n0\n207\n07-16\nP.801\nCANopen\n速率\n0\n:\n1Mbps\n0\n207\n1\n:\n500Kbps\n2\n:\n250K/280KFbps\n3\n:\n125Kbps\n4\n:\n100Kbps\n5\n:\n50\nKbps\n07-17\nP.802\nCANopen\n通讯状态\n0\n:节点复归状态\n0\n207\n1\n:通讯复归状态\n2\n:复归完成状态\n3\n:预操作状态\n4\n:操作状态\n5\n:停止状态\n07-18\nP.803\nCANopen\n控制状态\n0\n:开机尚未完成状态\n0\n207\n1\n:禁止运转状态\n2\n:预激磁状态\n3\n:激磁状态\n4\n:允许操作状态\n7\n:快速动作停止状态\n13\n:触发错误动作状态\n14\n:已错误状态" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "怎样设置COM1的通讯站号?" }
{ "neg": [ "通讯参数组\n07\n参数说明\n190\n5.8\n通讯参数组\n07\n参数\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n0\n:\nModbus\n协定\n1\n192\n1\n:士林\n协定\n2\n:\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n~\n254\n0\n192\n07-02\nP.32\nCOM1\n串行通讯串列传输速\n率\n0\n:串列传输速率为\n4800bps\n1\n192\n1\n:串列传输速率为\n9600bps\n2\n:串列传输速率为\n19200bps\n3\n:串列传输速率为\n38400bps\n4\n:串列传输速率为\n57600bps\n5\n:串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n:\n8bit\n0\n192\n1\n:\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n:\n1bit\n0\n192\n1\n:\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n:\n无同位\n0\n192\n1\n:\n奇数同位检查\n2\n:\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n:仅有\nCR\n1\n192\n2\n:\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n0\n:\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n4\n192\n1\n:\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n:\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n:\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n:\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n:\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n0\n~\n10\n1\n192\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n0\n~\n999.8s\n:\n以设定值进行通讯超时检验\n99999\n192\n99999\n:不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n:报警并空转停车\n0\n192\n1\n:不报警并继续运行\n07-11\nP.34\n通讯\nEEPROM\n写入选择\n0\n:通讯模式写入参数时,写入\nRAM\n和\nEEPROM\n0\n207\n1\n:通讯模式写入参数时,只写入\nRAM\n07-15\nP.800\nCANopen\n从站地址\n0\n~\n127\n0\n207\n07-16\nP.801\nCANopen\n速率\n0\n:\n1Mbps\n0\n207\n1\n:\n500Kbps\n2\n:\n250K/280KFbps\n3\n:\n125Kbps\n4\n:\n100Kbps\n5\n:\n50\nKbps\n07-17\nP.802\nCANopen\n通讯状态\n0\n:节点复归状态\n0\n207\n1\n:通讯复归状态\n2\n:复归完成状态\n3\n:预操作状态\n4\n:操作状态\n5\n:停止状态" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "COM1的数据长度可以怎样设定?" }
{ "neg": [ "基本参数组\n0\n1\n参数说明\n110\n例如\n:\n在参数为初始值的状态下\n(60Hz\n系统\n)\n,\n如下图所示\n,\n按\nS\n字加减速曲线\n3\n加速\n,\n从停止中运转至\n60Hz\n的实\n际加速时间为:\n设定加速时间\nT1\n=\n(01-09(P.20)\n-\n01-11(P.13))\n*\n01-06(P.7)/\n01-09(P.20)\n实际加速时间\nT2=\nT1\n+\n(01-36(P.255)\n+\n01-37(P.256)\n)\n*\n(01-09(P.20)\n-\n01-11(P.13))\n/\n2\n/\n01-09(P.20)\n所以\nT1\n=\n(60\n-\n0.5)\n*\n5\n/\n60\n=\n4.96s\n(\n直线加速时的实际加速时间\n)\n实际加速时间\nT2\n=\n4.96\n+\n(0.2\n+\n0.2)\n*\n(60\n-\n0.5)\n/\n2\n/\n60\n=\n5.16s\n注:所有加减速时间的计算都是基于\n01-09(P.20)\n。" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "COM1的停止位长度如何调整?" }
{ "neg": [ "通讯参数组\n07\n参数说明\n190\n5.8\n通讯参数组\n07\n参数\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n0\n:\nModbus\n协定\n1\n192\n1\n:士林\n协定\n2\n:\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n~\n254\n0\n192\n07-02\nP.32\nCOM1\n串行通讯串列传输速\n率\n0\n:串列传输速率为\n4800bps\n1\n192\n1\n:串列传输速率为\n9600bps\n2\n:串列传输速率为\n19200bps\n3\n:串列传输速率为\n38400bps\n4\n:串列传输速率为\n57600bps\n5\n:串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n:\n8bit\n0\n192\n1\n:\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n:\n1bit\n0\n192\n1\n:\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n:\n无同位\n0\n192\n1\n:\n奇数同位检查\n2\n:\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n:仅有\nCR\n1\n192\n2\n:\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n0\n:\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n4\n192\n1\n:\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n:\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n:\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n:\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n:\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n0\n~\n10\n1\n192\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n0\n~\n999.8s\n:\n以设定值进行通讯超时检验\n99999\n192\n99999\n:不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n:报警并空转停车\n0\n192\n1\n:不报警并继续运行\n07-11\nP.34\n通讯\nEEPROM\n写入选择\n0\n:通讯模式写入参数时,写入\nRAM\n和\nEEPROM\n0\n207\n1\n:通讯模式写入参数时,只写入\nRAM\n07-15\nP.800\nCANopen\n从站地址\n0\n~\n127\n0\n207\n07-16\nP.801\nCANopen\n速率\n0\n:\n1Mbps\n0\n207\n1\n:\n500Kbps\n2\n:\n250K/280KFbps\n3\n:\n125Kbps\n4\n:\n100Kbps\n5\n:\n50\nKbps\n07-17\nP.802\nCANopen\n通讯状态\n0\n:节点复归状态\n0\n207\n1\n:通讯复归状态\n2\n:复归完成状态\n3\n:预操作状态\n4\n:操作状态\n5\n:停止状态" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "如何选择COM1的奇偶检验?" }
{ "neg": [ "多段速\n参数组\n04\n参数说明\n156\n\n当\n04-03\n(P.24)\n~04-06\n(P.27)\n、\n04-07\n(P.142)\n~04-14\n(P.149)\n的参数设定值为\n99999\n时\n,\n目标频率由\nRL\n、\nRM\n、\nRH\n3\n个\n段速决定,如下表所示(端子优先权\nRL>RM>RH\n)\n:\n参数\n目标\n频率\n04-03(\nP.24)=\n99999\n04-04(\nP.25)=\n99999\n04-05(\nP.26)=\n99999\n04-06(\nP.27)=\n99999\n04-07\n(P.142\n)=9999\n9\n04-08(\nP.143)\n=9999\n9\n04-09(\nP.144)\n=9999\n9\n04-10(\nP.145)\n=9999\n9\n04-11(\nP.146)\n=9999\n9\n04-12(\nP.147)\n=9999\n9\n04-13(\nP.148)\n=9999\n9\n04-14(\nP.149)\n=9999\n9\nRL\n(\n04-02\n)\n○\n○\n○\n○\n○\n○\n○\n○\nRM\n(\n04-01\n)\n○\n○\n○\nRH\n(\n04-00\n)\n○\n例如:当\n04-05\n(P.26)\n=\n99999\n时,目标频率取决于\nRM\n(\n04-01\n(P.5)\n的设定值\n)\n。\n注:\n1.\n只有在「外部模式\n」\n、\n「混合模式\n2\n」或「混合模式\n4\n」下,才能使用多段速档位设定变频器的目标频率。\n2.\n本段落所提到的\nRL\n、\nRM\n、\nRH\n、\nREX\n为「多功能数位输入端子」的功能名称(例:\n03-03\n(P.80)\n=2\n,选择\nM0\n端\n子作为\nRL\n功能\n)\n。多功能数位输入端子的功能选择与功能,请参考\n03-03\n(P.80)\n、\n03-04\n(P.81)\n、\n03-05\n(P.82)\n、\n03-00\n(P.83)\n、\n03-01\n(P.84)\n、\n03-02\n(P.86)\n、\n03-06\n(P.126)\n、\n03-09\n(P.550)\n;相关配线,请参考\n3.5\n节。" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "如何设定CR/LF的选择?" }
{ "neg": [ "通讯参数组\n07\n参数说明\n190\n5.8\n通讯参数组\n07\n参数\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n0\n:\nModbus\n协定\n1\n192\n1\n:士林\n协定\n2\n:\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n~\n254\n0\n192\n07-02\nP.32\nCOM1\n串行通讯串列传输速\n率\n0\n:串列传输速率为\n4800bps\n1\n192\n1\n:串列传输速率为\n9600bps\n2\n:串列传输速率为\n19200bps\n3\n:串列传输速率为\n38400bps\n4\n:串列传输速率为\n57600bps\n5\n:串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n:\n8bit\n0\n192\n1\n:\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n:\n1bit\n0\n192\n1\n:\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n:\n无同位\n0\n192\n1\n:\n奇数同位检查\n2\n:\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n:仅有\nCR\n1\n192\n2\n:\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n0\n:\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n4\n192\n1\n:\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n:\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n:\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n:\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n:\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n0\n~\n10\n1\n192\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n0\n~\n999.8s\n:\n以设定值进行通讯超时检验\n99999\n192\n99999\n:不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n:报警并空转停车\n0\n192\n1\n:不报警并继续运行\n07-11\nP.34\n通讯\nEEPROM\n写入选择\n0\n:通讯模式写入参数时,写入\nRAM\n和\nEEPROM\n0\n207\n1\n:通讯模式写入参数时,只写入\nRAM\n07-15\nP.800\nCANopen\n从站地址\n0\n~\n127\n0\n207\n07-16\nP.801\nCANopen\n速率\n0\n:\n1Mbps\n0\n207\n1\n:\n500Kbps\n2\n:\n250K/280KFbps\n3\n:\n125Kbps\n4\n:\n100Kbps\n5\n:\n50\nKbps\n07-17\nP.802\nCANopen\n通讯状态\n0\n:节点复归状态\n0\n207\n1\n:通讯复归状态\n2\n:复归完成状态\n3\n:预操作状态\n4\n:操作状态\n5\n:停止状态" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "如何配置COM1的Modbus通讯格式?" }
{ "neg": [ "通讯参数组\n07\n参数说明\n190\n5.8\n通讯参数组\n07\n参数\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n0\n:\nModbus\n协定\n1\n192\n1\n:士林\n协定\n2\n:\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n~\n254\n0\n192\n07-02\nP.32\nCOM1\n串行通讯串列传输速\n率\n0\n:串列传输速率为\n4800bps\n1\n192\n1\n:串列传输速率为\n9600bps\n2\n:串列传输速率为\n19200bps\n3\n:串列传输速率为\n38400bps\n4\n:串列传输速率为\n57600bps\n5\n:串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n:\n8bit\n0\n192\n1\n:\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n:\n1bit\n0\n192\n1\n:\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n:\n无同位\n0\n192\n1\n:\n奇数同位检查\n2\n:\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n:仅有\nCR\n1\n192\n2\n:\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n0\n:\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n4\n192\n1\n:\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n:\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n:\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n:\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n:\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n0\n~\n10\n1\n192\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n0\n~\n999.8s\n:\n以设定值进行通讯超时检验\n99999\n192\n99999\n:不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n:报警并空转停车\n0\n192\n1\n:不报警并继续运行\n07-11\nP.34\n通讯\nEEPROM\n写入选择\n0\n:通讯模式写入参数时,写入\nRAM\n和\nEEPROM\n0\n207\n1\n:通讯模式写入参数时,只写入\nRAM\n07-15\nP.800\nCANopen\n从站地址\n0\n~\n127\n0\n207\n07-16\nP.801\nCANopen\n速率\n0\n:\n1Mbps\n0\n207\n1\n:\n500Kbps\n2\n:\n250K/280KFbps\n3\n:\n125Kbps\n4\n:\n100Kbps\n5\n:\n50\nKbps\n07-17\nP.802\nCANopen\n通讯状态\n0\n:节点复归状态\n0\n207\n1\n:通讯复归状态\n2\n:复归完成状态\n3\n:预操作状态\n4\n:操作状态\n5\n:停止状态" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "COM1通讯异常容许次数如何设定?" }
{ "neg": [ "通讯参数组\n07\n参数说明\n190\n5.8\n通讯参数组\n07\n参数\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n0\n:\nModbus\n协定\n1\n192\n1\n:士林\n协定\n2\n:\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n~\n254\n0\n192\n07-02\nP.32\nCOM1\n串行通讯串列传输速\n率\n0\n:串列传输速率为\n4800bps\n1\n192\n1\n:串列传输速率为\n9600bps\n2\n:串列传输速率为\n19200bps\n3\n:串列传输速率为\n38400bps\n4\n:串列传输速率为\n57600bps\n5\n:串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n:\n8bit\n0\n192\n1\n:\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n:\n1bit\n0\n192\n1\n:\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n:\n无同位\n0\n192\n1\n:\n奇数同位检查\n2\n:\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n:仅有\nCR\n1\n192\n2\n:\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n0\n:\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n4\n192\n1\n:\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n:\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n:\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n:\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n:\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n0\n~\n10\n1\n192\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n0\n~\n999.8s\n:\n以设定值进行通讯超时检验\n99999\n192\n99999\n:不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n:报警并空转停车\n0\n192\n1\n:不报警并继续运行\n07-11\nP.34\n通讯\nEEPROM\n写入选择\n0\n:通讯模式写入参数时,写入\nRAM\n和\nEEPROM\n0\n207\n1\n:通讯模式写入参数时,只写入\nRAM\n07-15\nP.800\nCANopen\n从站地址\n0\n~\n127\n0\n207\n07-16\nP.801\nCANopen\n速率\n0\n:\n1Mbps\n0\n207\n1\n:\n500Kbps\n2\n:\n250K/280KFbps\n3\n:\n125Kbps\n4\n:\n100Kbps\n5\n:\n50\nKbps\n07-17\nP.802\nCANopen\n通讯状态\n0\n:节点复归状态\n0\n207\n1\n:通讯复归状态\n2\n:复归完成状态\n3\n:预操作状态\n4\n:操作状态\n5\n:停止状态" ], "pos": [ "通讯参数组\n07\n参数说明\n192\n5.8.1\n士林\n协定\n及\nModbus\n协定\n\n可以通过变频器的\nRS-485\n通信\n埠\n和上位机链接通讯,进行参数设定,监视等。\n参数\n名称\n出厂值\n设定范围\n内容\n07-00\nP.33\nCOM1\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-01\nP.36\nCOM1\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-02\nP.32\nCOM1\n串行通讯串列传输\n速率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-03\nP.48\nCOM1\n数据长度\n0\n0\n8bit\n1\n7bit\n07-04\nP.49\nCOM1\n停止位长度\n0\n0\n1bit\n1\n2bit\n07-05\nP.50\nCOM1\n奇偶检验选择\n0\n0\n无同位\n1\n奇数同位检查\n2\n偶数同位检查\n07-06\nP.51\nCOM1\nCR/LF\n选择\n1\n1\n仅有\nCR\n2\nCR,LF\n皆有\n07-07\nP.154\nCOM1\nModbus\n通讯格式\n4\n0\n1\n、\n7\n、\nN\n、\n2\n(Modbus,\nASCII)\n1\n1\n、\n7\n、\nE\n、\n1\n(Modbus,\nASCII)\n2\n1\n、\n7\n、\nO\n、\n1\n(Modbus,\nASCII)\n3\n1\n、\n8\n、\nN\n、\n2\n(Modbus,\nRTU)\n4\n1\n、\n8\n、\nE\n、\n1\n(Modbus,\nRTU)\n5\n1\n、\n8\n、\nO\n、\n1\n(Modbus,\nRTU)\n07-08\nP.52\nCOM1\n通讯异常容许次数\n1\n0\n~\n10\n当通讯出错次数超过\n07-08(P.52)\n的设定值,且\n07-10(P.153)\n设为\n0\n,则报异警\nOPT\n。\n07-09\nP.53\nCOM1\n通讯间隔容许时间\n99999\n0\n~\n999.8s\n以设定值进行通讯超时检验\n99999\n不进行超时检验\n07-10\nP.153\nCOM1\n通讯错误处理\n0\n0\n报警并空转停车\n1\n不报警并继续运行\n07-25\nP.810\nPU\n通讯\n协定\n选择\n1\n0\nModbus\n协定\n1\n士林\n协定\n2\nPLC\n协定\n(使用士林内置\nPLC\n时有效)\n07-26\nP.811\nPU\n变频器通讯站号\n0\n0\n~\n254\n实际实现台数由配线方式及阻抗匹配决定。使用\nModbus\n协定\n时请将其值设为非\n0\n值。\n07-27\nP.812\nPU\n串行通讯串列传输速\n率\n1\n0\n串列传输速率为\n4800bps\n1\n串列传输速率为\n9600bps\n2\n串列传输速率为\n19200bps\n3\n串列传输速率为\n38400bps\n4\n串列传输速率为\n57600bps\n5\n串列传输速率为\n115200bps\n07-28\nP.813\nPU\n数据长度\n0\n0\n8bit\n1\n7bit\n07-29\nP.814\nPU\n停止位长度\n0\n0\n1bit\n1\n2bit" ], "query": "如何设置COM1通讯间隔容许时间?" }
{ "neg": [ "基本\n参数组\n01\n参数说明\n105\n5.2.7\nJOG\n运行\n\n能够设定点动运行用的频率和加减速时间。能够进行运输机械的位置调整和试运行等。\n参数\n名称\n出厂值\n设定范围\n内容\n01-13\nP.15\nJOG\n频率\n5.00Hz\n0\n~\n650.00Hz\n---\n01-14\nP.16\nJOG\n加减速时间\n0.50s\n0\n~\n360.00s/\n0\n~\n3600.0s\n01-0\n(P.21)\n=0/\n01-08\n(P.21)\n=1\n设定\nJOG\n运行\n\n在\nJOG\n模式下,变频器的目标频率为\n01-13\n(P.15)\n的设定值,加速时间与减速时间为\n01-14\n(P.16)\n的设定值\n注:如何进入\nJOG\n模式,请参考\n4.3.3\n节的内容。\n5.2.8\n输出频率滤波时间\n\n设定输出频率滤波时间可在高低频相互切换的瞬间对输出频率进行滤波,以减小机器的震动。\n参数\n名称\n出厂值\n设定范围\n内容\n01-15\nP.28\n输出频率滤波时间\n0ms\n0\n~\n1000ms\n---\n设定\n输出频率滤波时间\n\n输出频率滤波常数设定值越大,滤波效果越好,但相应的也会造成回应延迟加大。\n\n当设定值为\n0\n时,该滤波功能无效。" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "如何调整变频器的JOG频率?" }
{ "neg": [ "基本参数组\n0\n1\n参数说明\n110\n例如\n:\n在参数为初始值的状态下\n(60Hz\n系统\n)\n,\n如下图所示\n,\n按\nS\n字加减速曲线\n3\n加速\n,\n从停止中运转至\n60Hz\n的实\n际加速时间为:\n设定加速时间\nT1\n=\n(01-09(P.20)\n-\n01-11(P.13))\n*\n01-06(P.7)/\n01-09(P.20)\n实际加速时间\nT2=\nT1\n+\n(01-36(P.255)\n+\n01-37(P.256)\n)\n*\n(01-09(P.20)\n-\n01-11(P.13))\n/\n2\n/\n01-09(P.20)\n所以\nT1\n=\n(60\n-\n0.5)\n*\n5\n/\n60\n=\n4.96s\n(\n直线加速时的实际加速时间\n)\n实际加速时间\nT2\n=\n4.96\n+\n(0.2\n+\n0.2)\n*\n(60\n-\n0.5)\n/\n2\n/\n60\n=\n5.16s\n注:所有加减速时间的计算都是基于\n01-09(P.20)\n。" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "加减速时间的设定方法在哪里可以找到?" }
{ "neg": [ "基本\n参数组\n01\n参数说明\n105\n5.2.7\nJOG\n运行\n\n能够设定点动运行用的频率和加减速时间。能够进行运输机械的位置调整和试运行等。\n参数\n名称\n出厂值\n设定范围\n内容\n01-13\nP.15\nJOG\n频率\n5.00Hz\n0\n~\n650.00Hz\n---\n01-14\nP.16\nJOG\n加减速时间\n0.50s\n0\n~\n360.00s/\n0\n~\n3600.0s\n01-0\n(P.21)\n=0/\n01-08\n(P.21)\n=1\n设定\nJOG\n运行\n\n在\nJOG\n模式下,变频器的目标频率为\n01-13\n(P.15)\n的设定值,加速时间与减速时间为\n01-14\n(P.16)\n的设定值\n注:如何进入\nJOG\n模式,请参考\n4.3.3\n节的内容。\n5.2.8\n输出频率滤波时间\n\n设定输出频率滤波时间可在高低频相互切换的瞬间对输出频率进行滤波,以减小机器的震动。\n参数\n名称\n出厂值\n设定范围\n内容\n01-15\nP.28\n输出频率滤波时间\n0ms\n0\n~\n1000ms\n---\n设定\n输出频率滤波时间\n\n输出频率滤波常数设定值越大,滤波效果越好,但相应的也会造成回应延迟加大。\n\n当设定值为\n0\n时,该滤波功能无效。" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "如何设置输出频率滤波时间?" }
{ "neg": [ "P.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "如何配置回避频率1A?" }
{ "neg": [ "P.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "怎样设定回避频率1B?" }
{ "neg": [ "P.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "650.00Hz的频率如何应用?" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n287\n设定\n用户登记参数\n\n此参数组中设定的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/6\n时,不会被恢复出厂设定值。\n\n此参数组中设定的参数值为用户需要登记的参数号,被登记的参数号的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/\n6\n时,不会被恢复出厂设定值。\n\n恢复出厂值的设定请参照\n5.1.2\n参数管理部分。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n(\nP.7\n)\n,\n「顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的\n参数号为\n01-06\n,设定\n15-00=106\n。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n,\n「\n顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的参数号\n为\n01-06\n(\nP.7\n)\n,设定\n15-00=106\n。" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "如何清除无效的配置?" }
{ "neg": [ "多段速\n参数组\n04\n参数说明\n154\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n04-31\nP.105\n程式运行模式第五段速运行\n时间\n0\n~\n6000.0s\n0.0s\n158\n04-32\nP.106\n程式运行模式第六段速运行\n时间\n0\n~\n6000.0s\n0.0s\n158\n04-33\nP.107\n程式运行模式第七段速运行\n时间\n0\n~\n6000.0s\n0.0s\n158\n04-34\nP.108\n程式运行模式第八段速运行\n时间\n0\n~\n6000.0s\n0.0s\n159\n04-35\nP.111\n程式运行模式第一段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-36\nP.112\n程式运行模式第二段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-37\nP.113\n程式运行模式第三段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-38\nP.114\n程式运行模式第四段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-39\nP.115\n程式运行模式第五段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-40\nP.116\n程式运行模式第六段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-41\nP.117\n程式运行模式第七段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-42\nP.118\n程式运行模式第八段速加减\n速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159" ], "pos": [ ":\nV/F\n半分离模式\n01-13\nP.15\nJOG\n频率\n0\n~\n650.00Hz\n5.00Hz\n107\n01-14\nP.16\nJOG\n加减速时间\n0\n~\n360.00s/0\n~\n3600.0s\n0.50s\n107\n01-15\nP.28\n输出频率滤波时间\n0\n~\n1000ms\n0ms\n107\n01-16\nP.91\n回避频率\n1A\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效\n01-17\nP.92\n回避频率\n1B\n0\n~\n650.00Hz\n99999\n108\n99999\n:无效" ], "query": "是否有其他特殊的功能或参数需要额外的设置?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n318\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.547\n02-37\n3-5\n最大输入电流\n/\n电压\n对应百分比\n-100.0%\n~\n100.0%\n100.0%\n127\n-400.0%\n~\n400.0%\n(\nP.504\n=\n2/14/15/16/17\n)\nP.548\n02-34\n3-5\n最小输入电流\n/\n电压\n0\n~\n10.00V\n0.00V\n127\nP.549\n02-35\n3-5\n最大输入电流\n/\n电压\n0\n~\n10.00V\n10.00V\n127\nP.550\n03-09\nHDI\n端子功能设置\n同\n03-00\n(P.83)\n57\n141\nP.551\n03-25\n数位输入端\n子\nM10(Slot3)\n同\n03-00\n(P.83)\n99999\n150\nP.552\n03-26\n数位输入端\n子\nM11(Slot3)\n同\n03-00\n(P.83)\n99999\n150\nP.553\n03-27\n数位输入端\n子\nM12(Slot3)\n同\n03-00\n(P.83)\n99999\n150\nP.554\n03-28\n数位输入端\n子\nM13(Slot3)\n同\n03-00\n(P.83)\n99999\n150\nP.555\n03-29\n数位输入端\n子\nM14(Slot3)\n同\n03-00\n(P.83)\n99999\n150\nP.556\n03-30\n数位输入端\n子\nM15(Slot3)\n同\n03-00\n(P.83)\n99999\n150\nP.559\n03-33\n数位输入端\n子\nM10(Slot2)\n同\n03-00\n(P.83)\n99999\n150\nP.560\n03-34\n数位输入端\n子\nM11(Slot2)\n同\n03-00\n(P.83)\n99999\n150\nP.561\n03-35\n数位输入端\n子\nM12(Slot2)\n同\n03-00\n(P.83)\n99999\n150\nP.562\n03-36\n数位输入端\n子\nM13(Slot2)\n同\n03-00\n(P.83)\n99999\n150\nP.563\n03-37\n数位输入端\n子\nM14(Slot2)\n同\n03-00\n(P.83)\n99999\n150\nP.564\n03-38\n数位输入端\n子\nM15(Slot2)\n同\n03-00\n(P.83)\n99999\n150\nP.567\n03-41\n外扩数位输入端子正反\n逻辑\n(Slot2&3)\n0\n~\n65535\n0\n151\nP.568\n03-42\n数位输出端\n子\nA10(Slot3)\n同\n03-10(P.40)\n99999\n151\nP.569\n03-43\n数位输出端\n子\nA11(Slot3)\n同\n03-10(P.40)\n99999\n151\nP.570\n03-44\n数位输出端\n子\nA12(Slot3)\n同\n03-10(P.40)\n99999\n151\nP.571\n03-45\n数位输出端\n子\nA13(Slot3)\n同\n03-10(P.40)\n99999\n151\nP.572\n03-46\n数位输出端\n子\nA14(Slot3)\n同\n03-10(P.40)\n99999\n151\nP.573\n03-47\n数位输出端\n子\nA15(Slot3)\n同\n03-10(P.40)\n99999\n151" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "关于参数组0的输出功能选择,如何设定为输出电流?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n128\n参数\n名称\n出厂值\n设定范围\n内容\n02-44\nP.543\nFM\n输出功能选择\n0\n8\n激磁\n电流\n,\n以\n马达\n额定电流为\n100%\n(\n此功能只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定为\n3~6\n时有效)\n9\n输出转矩,以\n2\n倍的\n马达\n额定转矩为\n100%\n(此功能只\n在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定为\n3~6\n时有效)\n10\n输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n高速脉冲输入,以\n100.00KHz\n为\n100%\n12\n马达运转速度,以显示基准\n02-51(P.55)\n为\n100%\n设定\nFM\n类比\n输出端子的使用\n\nFM\n端子的校正,请参照\n5.4.7FM\n校正系数。\n5.3.11\nAM1\n输出的选择与处理\n\n此功能用来调整变频器\n类比\n信号\nAM1\n输出端子,\nAM1\n输出至\n类比\n表头的\n准\n位。\n参数\n名称\n出厂值\n设定范围\n内容\n02-45\nP.64\nAM1\n输出信号选择\n0\n0\nAM1-5\n之间输出\n0\n~\n10V\n电压\n1\n保留\n2\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n3210\n0\n~\n5000\n---\n02-47\nP.190\nAM1\n输出偏置\n18\n0\n~\n5000\n---\n设定\nAM1\n输出的选择与处理\n\nAM1\n端子的输出电流\n/\n电压是由控制板上的拨动开关\nSW3\n和参数\n02-45(P.64)\n共同来设定的\n,\n用户在选择\nAM1\n端子\n的输出类型时,请先把拨动开关\nSW3\n拨到相应的类型上,再设定\n02-45(P.64)\n的值。\n\nAM1\n端子输出如下图所示:\n图\n1.\nAM1-5\n输出\n0~10V\n电压\n图\n2.\nAM1-5\n输出\n0~20mA\n电流" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "如何设定AM1的输出信号选择为输出0~10V电压?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n02\n参数说明\n129\n图\n3.\nAM1-5\n输出\n4~20mA\n电流\n\n因为组件上的差异,表头需要校正。\nAM1\n端子电压\n/\n电流校正步骤如下:\n1.\n拨动开关\nSW3\n拨到\n0~10V/0~20mA\n端,然后设定\n02-45(P.64)=0\n/\n02-45(P.64)=2\n;\n2.\n在\nAM1\n端子与\n5\n端子之间接一只\n[\n全刻度为\n10V/20mA\n的电表\n]\n,并且设定\n02-04(P.54)=0\n,\n02-51(P.55)=60Hz\n。\n3.\n将\n01-11(P.13)\n设为\n0\n,启动\n马达\n运转,固定变频器输出频率为\n0Hz\n。\n4.\n按\n>\n键调整\n02-47(P.190)\n的值,显示幕显示的\nAM1\n输出偏置值向上累加,按\nW R ITE\n键并保持\n1s\n以上,表\n头指针向上移动\n;\n按\n>\n下降键调整\n02-47(P.190)\n的值\n,\n显示幕显示的\nAM1\n输出偏置值向下递减\n,\n按\nW R ITE\n键并保持\n1s\n以上,表头指针向下移动;当调整指针至\n0\n刻度位置时,完成\nAM1\n输出偏置值校正工作。\n5.\n调整并固定变频器的输出频率在\n60Hz\n。\n6.\n将\n02-46(P.191)\n的设定值读出,此时显示幕显示当时的\nAM1\n输出增益。\n7.\n按\n>\n键或是\n>\n键调整\n02-46(P.191)\n的值\n,\nW R ITE\n键并保持\n1s\n以上\n,\n表头指针向上或向下移动\n,\n当调整\n指针移至全刻度位置时,完成校正工作。\n注\n:\n在\nAM1\n输出信号进行选择时\n,\n请注意开关\nSW3\n的切换\n。\n如果选择\n4~20mA\n输出电流\n,\n请把\nSW3\n拨到\n0~20mA\n侧\n。\n5.3.12\nAM2\n输出的选择与处理\n\n此功能用来调整变频器\n类比\n信号\nAM2\n输出端子,\nAM2\n输出至\n类比\n表头的\n准\n位。\n参数\n名称\n出厂值\n设定范围\n内容\n02-48\nP.538\nAM2\n输出信号选择\n0\n0\nAM2-5\n之间输出\n0\n~\n10V\n电压\n1\n保留\n2\nAM2-5\n之间输出\n0\n~\n20mA\n电流\n3\nAM2-5\n之间输出\n4\n~\n20mA\n电流\n02-49\nP.536\nAM2\n输出增益\n3210\n0\n~\n5000\n---\n02-50\nP.535\nAM2\n输出偏置\n18\n0\n~\n5000\n---\n设定\nAM2\n输出的选择与处理\n\n此端子功能参照\nAM1\n的相关说明,调整\nAM2\n的偏压和增益的动作与\nAM1\n类似,\n02-50\n对应\n02-47(P.190)\n,\n02-4\n9\n对应\n02-46(P.191)\n。\n\nAM2\n端子的输出电流\n/\n电压是由控制板上的拨动开关\nSW4\n和参数\n02-48(P.538)\n共同设定的\n,\n出厂\n预设\n值为\n0~10V\n。\n.\n注\n:\n在\nAM2\n输出信号进行选择时\n,\n请注意开关\nSW4\n的切换\n。\n如果选择\n4~20mA\n输出电流\n,\n请把\nSW4\n拨到\n0~20mA\n侧\n。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "怎样调整AM1的输出增益?" }
{ "neg": [ "基本\n参数组\n01\n参数说明\n97\n5.2.1\n限制输出频率\n\n可对输出频率进行限制。对输出频率的上限及下限实施钳位。\n参数\n名称\n出厂值\n设定范围\n内容\n01-00\nP.1\n上限频率\n120.00Hz\n0.00\n~\n01-02\n(\nP.18\n)\nHz\n55K/75KF\n及以下机种\n60.00Hz\n75K/90KF\n及以上机种\n01-01\nP.2\n下限频率\n0.00Hz\n0\n~\n120.00Hz\n输出频率下限\n01-02\nP.18\n高速上限频率\n120.00Hz\n01-00\n(\nP.1\n)~\n650.00Hz\n进行\n120Hz\n以上运行时设定\n设定\n上限频率、高速上限频率\n\n「上限频率」与「高速上限频率」是相互牵连的:\n1.\n当目标频率需要限制在\n01-00(P.1)\n以下的时候,请用\n01-00(P.1)\n作为上限频率;\n2.\n当目标频率需要限制在\n01-00(P.1)\n以上时,请用\n01-02(P.18)\n作为上限频率。\n\n若\n01-00(P.1)<\n01-01(P.2)\n,则稳定输出频率永远等于\n01-00(P.1)\n的设定值。\n\n设定\nPU\n模式的目标频率时,所设定的频率值不会超过\n01-00(P.1)\n的值。\n设定\n下限频率\n\n若目标频率\n≤\n01-01(P.2)\n,则稳定输出频率\n=\n01-01(P.2)\n。\n\n若\n01-01(P.2)<\n目标频率\n≤\n01-00(P.1)\n(01-02(P.18))\n,则稳定输出频率\n=\n目标频率。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "如何设定类比输出时的频率显示基准为60Hz?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n02\n参数说明\n131\n5.3.15\nPT100\n准\n位设定\n\n通过参数设定\nPT100\n保护\n准\n位及动作频率\n参数\n名称\n出厂值\n设定范围\n内容\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n5.00V\n0\n~\n10.00V\n0\n无\nPT100\n准\n位\n1\n保护\n0.10V~10.00V\nPT100\n大于\n准\n位\n1\n时\n,\n经过\n02-58(P.595)\n设定时\n间后,输出频率降低到\n02-57(P.594)\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n7.00V\n0\n~\n10.00V\n0\n无\nPT100\n准\n位\n2\n保护\n0.10V~10.00V\nPT100\n大于\n准\n位\n2\n时\n,\n根据\n06-15(P.533)\n设定作\n出相应动作\n02-57\nP.594\nPT10\n0\n准\n位\n1\n开始频率\n0.00Hz\n0\n~\n650.00Hz\n超出\nPT100\n准\n位\n1\n后,输出频率下降到\n02-57(P.594)\n02-58\nP.595\n启\n动\nPT10\n0\n准\n位\n1\n延迟\n时间\n60s\n0\n~\n6000s\n输出频率下降到\n02-57(P.594)\n的动作延迟时间\n设定\nPT100\n准\n位设定\n\nPT100\n通过\n类比\n电压输入,设定\n2-5/4-5/3-5\n的电压输入范围为\n0~10V(02-08(P.73)=1;02-20(P.17)=1;\n02-29(P.531)=1\n,并请注意控制板上的电压\n/\n电流切换开关拨到电压输入位置\n)\n,并设定\n类比\n电压输入用于\nPT100\n功\n能\n(02-00(P.500),02-01(P.501),02-02(P.504)\n设定为\n12)\n。\n\n当变频器处于运转状态\n,\nPT100\n输入电压大于\n02-55(P.592)\n设定值\n,\n经过\n02-58(P.595)\n设定时间后\n,\n变频器输出频\n率降低到\n02-57(P.594)\n设定频率。\n\n当\nPT100\n输入电压大于\n02-56(P.593)\n设定值时,变频器将按照\n06-15(P.533)\n设定作出相应动作。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "怎样设置PT100电压准位为5.00V?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n130\n5.3.13\n类比\n输出时显示基准\n\n用于设定在\nAM/FM\n类比\n输出时选择输出频率和输出电流时的显示基准。\n参数\n名称\n出厂值\n设定范围\n内容\n02-51\nP.55\n类比\n输出时\n频率显示基\n准\n50.00Hz\n0\n~\n650.00Hz\n50Hz\n系统设定时(当\n00-24\n(P.189)\n=1\n时)\n60.00Hz\n60Hz\n系统设定时(当\n00-24\n(P.189)\n=0\n时)\n02-52\nP.56\n类比\n输出时\n电流显示基\n准\n注\n0\n~\n500.00A\nG\n框架以下机种\n0\n~\n5000.0A\nG\n框架及其以上机种\n设定\n显示基准\n\n以\n02-51\n(P.55)\n的设定频率为\n100%\n对应\nAM/FM\n的最大输出。\n\n以\n02-52\n(P.56)\n的设定频率为\n100%\n对应\nAM/FM\n的最大输出。\n注:参数\n02-52(P.56)\n的出厂值由机种决定。\n5.3.14\nAM/FM\n固定输出\n准\n位\n\n此设定使\nAM/FM\n输出为一固定的输出。\n参数\n名称\n出厂值\n设定范围\n内容\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0.0%\n0\n~\n100.0%\n---\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0.0%\n0\n~\n100.0%\n---\n设定\n\nA\nM\n的电压\n/\n电流输出\n由\n02-53(P.539)\n与\n02-54(P.541)\n控制\n,\n02-53(P.539)\n设\n定\n0~100.0%\n对\n应\nAM\n2\n的\n0~10V/20mA\n;\n02-54(P.541)\n设定\n0~100.0%\n对应\nAM1\n的\n0~10V/20mA\n;\n例如\n:\n02-54(P.541)=50%\n,\nAM1\n输出\n10V*50%=5V\n。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "如何调整AM2的固定输出准位为50%?" }
{ "neg": [ "应用参数组\n10\n参数说明\n244\n2.\n有自动切换顺序(\n10-31\n(P.249)\n≠\n99999,\n10-32\n(P.250)\n=\n99999\n)的动作顺序\n3.\n有自动切换顺序(\n10-31\n(P.249)\n≠\n99999,\n10-32\n(P.250)\n≠\n99999\n)的动作顺序例\n自动切换时,\nA\n:\n10-29(P.247)\nMC\n切换互锁时间,\nB\n:\n10-30(P.248)\n启动等待时间,\nC\n:\n10-09(P.57)\n再启动\n自由运行时间,\nD\n:\n10-10(P.58)\n再启动上升时间。\n注\n:\n1.\n马达\n在\n50Hz\n(\n或者\n60Hz\n)\n的频率下运行时\n,\n以\n电源频率\n电源运行效率更高\n。\n另外\n,\n变频器维护检修时\n,\n为使\n马\n达\n不长时间停止,建议同时设置\n电源频率\n电源电路。\n2.\n切换变频器运行和\n电源频率\n电源运行时,为使变频器不进行过电流报警,必须采取互锁措施,一旦\n马达\n停止后\n,\n通过变频器开始启动\n。\n如果使用能够输出使电磁接触器动作的信号的\n电源频率\n切换时序功能\n,\n能够通过变频器与\n复杂的\n电源频率\n电源进行切换互锁。\n3.\n此功能只在\nV/F\n模式下有效,即\n00-21(\nP.300\n)=0\n时有效。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "怎样设定PT100准位1的开始频率为100.00Hz?" }
{ "neg": [ "基本参数组\n0\n1\n参数说明\n110\n例如\n:\n在参数为初始值的状态下\n(60Hz\n系统\n)\n,\n如下图所示\n,\n按\nS\n字加减速曲线\n3\n加速\n,\n从停止中运转至\n60Hz\n的实\n际加速时间为:\n设定加速时间\nT1\n=\n(01-09(P.20)\n-\n01-11(P.13))\n*\n01-06(P.7)/\n01-09(P.20)\n实际加速时间\nT2=\nT1\n+\n(01-36(P.255)\n+\n01-37(P.256)\n)\n*\n(01-09(P.20)\n-\n01-11(P.13))\n/\n2\n/\n01-09(P.20)\n所以\nT1\n=\n(60\n-\n0.5)\n*\n5\n/\n60\n=\n4.96s\n(\n直线加速时的实际加速时间\n)\n实际加速时间\nT2\n=\n4.96\n+\n(0.2\n+\n0.2)\n*\n(60\n-\n0.5)\n/\n2\n/\n60\n=\n5.16s\n注:所有加减速时间的计算都是基于\n01-09(P.20)\n。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "如何延迟PT100准位1的启动时间到120s?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n132\n5.3.16\nFM\n校正系数\n\n用来调整变频器\n类比\n信号\nFM\n输出端子,\nFM\n输出至\n类比\n表头的\n准\n位。\n参数\n名称\n出厂值\n设定范围\n内容\n02-59\nP.187\nFM\n校正系数\n450\n0\n~\n9998\n---\n设定\nFM\n校正系数\n\nHDO\n端子为\nFM\n功能时输出如下图所示:\n\n因为组件上的差异,表头需要校正。\nHDO\n端子校正步骤如下:\n1.\n在\nHDO\n端子与\nSD\n端子之间接一只\n[\n全刻度为\n1mA\n的电表或者频率计数器\n]\n,接线如下图所示,并且设定\n02-51(P.55)\n=\n60Hz\n,\n02-44(P.543)=0\n。\n2.\n启动\n马达\n运转并固定变频器输出频率为\n60Hz\n。\n3.\n待运转稳定后\n,\n将\n02-59(P.187)\n的设定值读出\n,\n此时显示幕显示当时\n的\nF\nM\n校正系数\n,\n按\n>\n键调\n整\n02-59(P.187)\n的值\n,\n显示幕显示的\nFM\n校正系数向上累加\n,\n按\nW R ITE\n键并保持\n1s\n以上\n,\n表头指针向上移动\n;\n按\n>\n下降键\n调整\n02-59(P.187)\n的值\n,\n显示幕显示的\nFM\n校正系数向下递减\n,\n按\nW R ITE\n键并保持\n1s\n以上\n,\n表头指针向下移动\n。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "怎样校正FM的校正系数为800?" }
{ "neg": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n130\n5.3.13\n类比\n输出时显示基准\n\n用于设定在\nAM/FM\n类比\n输出时选择输出频率和输出电流时的显示基准。\n参数\n名称\n出厂值\n设定范围\n内容\n02-51\nP.55\n类比\n输出时\n频率显示基\n准\n50.00Hz\n0\n~\n650.00Hz\n50Hz\n系统设定时(当\n00-24\n(P.189)\n=1\n时)\n60.00Hz\n60Hz\n系统设定时(当\n00-24\n(P.189)\n=0\n时)\n02-52\nP.56\n类比\n输出时\n电流显示基\n准\n注\n0\n~\n500.00A\nG\n框架以下机种\n0\n~\n5000.0A\nG\n框架及其以上机种\n设定\n显示基准\n\n以\n02-51\n(P.55)\n的设定频率为\n100%\n对应\nAM/FM\n的最大输出。\n\n以\n02-52\n(P.56)\n的设定频率为\n100%\n对应\nAM/FM\n的最大输出。\n注:参数\n02-52(P.56)\n的出厂值由机种决定。\n5.3.14\nAM/FM\n固定输出\n准\n位\n\n此设定使\nAM/FM\n输出为一固定的输出。\n参数\n名称\n出厂值\n设定范围\n内容\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0.0%\n0\n~\n100.0%\n---\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0.0%\n0\n~\n100.0%\n---\n设定\n\nA\nM\n的电压\n/\n电流输出\n由\n02-53(P.539)\n与\n02-54(P.541)\n控制\n,\n02-53(P.539)\n设\n定\n0~100.0%\n对\n应\nAM\n2\n的\n0~10V/20mA\n;\n02-54(P.541)\n设定\n0~100.0%\n对应\nAM1\n的\n0~10V/20mA\n;\n例如\n:\n02-54(P.541)=50%\n,\nAM1\n输出\n10V*50%=5V\n。" ], "pos": [ "类比输\n入\n输\n出\n参数组\n0\n2\n参数说明\n114\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n02-44\nP.543\nFM\n输出功能选择\n0\n:输出频率,以显示基准\n02-51(P.55)\n为\n100%\n0\n129\n1\n:输出电流,以显示基准\n02-52(P.56)\n为\n100%\n2\n:输出\nP-N\n端\n电压,以\nOV\n准\n位为\n100%\n3\n:\n输出变频器温升累计率\n,\n以\nNTC\n准\n位为\n100%\n4\n:输出变频器电子积热率:\n以电子热动电驿动作\n(\n当\n06-00(P.9)\n≠\n0\n时\n)\n或\nIGBT\n模组积热电驿动作\n(\n当\n06-00(P.9)=\n0\n时\n)\n为\n100%\n5\n:目标频率,以显示基准\n02-51(P.55)\n为\n100%\n6\n:\n固定脉冲输出\n,\n脉冲输出\n准\n位可\n由\n02-54(P.541)\n设定\n7\n:输出电压,以变频器额定电压为\n100%\n8\n:\n激磁\n电流,以\n马达\n额定电流为\n100%\n(此功能\n只在\n00-21\n(\nP.300\n)\n或者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效\n)\n。\n9\n:\n输出转矩\n,\n以\n2\n倍的\n马达\n额定转矩为\n100%\n(\n此\n功能只\n在\n00-21\n(\nP.300\n)\n或\n者\n00-22\n(\nP.370\n)\n设定\n为\n3~6\n时有效)\n10\n:输出功率,以\n2\n倍的\n马达\n额定功率为\n100%\n11\n:高速脉冲输入,以\n100.00KHz\n为\n100%\n12:\n马达运转速度\n,\n以显示基准\n02-51\n(\nP.55\n)为\n100%\n02-45\nP.64\nAM1\n输出信号选择\n0\n:\nAM1-5\n之间输出\n0\n~\n10V\n电压\n0\n12\n9\n1\n:保留\n2\n:\nAM1-5\n之间输出\n0\n~\n20mA\n电流\n3\n:\nAM1-5\n之间输出\n4\n~\n20mA\n电流\n02-46\nP.191\nAM1\n输出增益\n0\n~\n5000\n3210\n12\n9\n02-47\nP.190\nAM1\n输出偏置\n0\n~\n5000\n18\n12\n9\n02-48\nP.538\nAM2\n输出信号选择\n同\n02-45(P.64)\n0\n131\n02-49\nP.536\nAM2\n输出增益\n0\n~\n5000\n3210\n131\n02-50\nP.535\nAM2\n输出偏压\n0\n~\n5000\n18\n131\n02-51\nP.55\n类比\n输出时频率显示基准\n50Hz\n系统设定时:\n0.00\n~\n650.00Hz\n50.00Hz\n131\n60Hz\n系统设定时:\n0.00\n~\n650.00Hz\n60.00Hz\n02-52\nP.56\n类比\n输出时\n电流显示基准\n0~500.00A\n:\nG\n框架以下机种\n按机种\n131\n0~5000.0A\n:\nG\n框架及其以上机种\n02-53\nP.539\nAM2\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-54\nP.541\nAM1/FM\n固定输出\n准\n位\n0\n~\n100.0%\n0.0%\n132\n02-55\nP.592\nPT100\n电压\n准\n位\n1\n0\n~\n10.00V\n5.00V\n132\n02-56\nP.593\nPT100\n电压\n准\n位\n2\n0\n~\n10.00V\n7.00V\n132\n02-57\nP.594\nPT100\n准\n位\n1\n开始频率\n0\n~\n650.00Hz\n0.00Hz\n132\n02-58\nP.595\n启动\nPT100\n准\n位\n1\n延迟时间\n0\n~\n6000s\n60s\n132\n02-59\nP.187\nFM\n校正系数\n0\n~\n9998\n450\n133" ], "query": "如何将AM1/FM的固定输出准位设定为20%?" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n287\n设定\n用户登记参数\n\n此参数组中设定的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/6\n时,不会被恢复出厂设定值。\n\n此参数组中设定的参数值为用户需要登记的参数号,被登记的参数号的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/\n6\n时,不会被恢复出厂设定值。\n\n恢复出厂值的设定请参照\n5.1.2\n参数管理部分。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n(\nP.7\n)\n,\n「顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的\n参数号为\n01-06\n,设定\n15-00=106\n。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n,\n「\n顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的参数号\n为\n01-06\n(\nP.7\n)\n,设定\n15-00=106\n。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "请解释一下参数模式和参数组模式的区别。" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n286\n5.16.1\n用户登记参数\n\n用户参数组用来登记用户不需要被恢复出厂值的参数的参数号。\n参数\n名称\n出厂值\n设定范围\n内容\n15-00\nP.900\n用户登记参数\n1\n99999\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n---\n15-01\nP.901\n用户登记参数\n2\n99999\n---\n15-02\nP.902\n用户登记参数\n3\n99999\n---\n15-03\nP.903\n用户登记参数\n4\n99999\n---\n15-04\nP.904\n用户登记参数\n5\n99999\n---\n15-05\nP.905\n用户登记参数\n6\n99999\n---\n15-06\nP.906\n用户登记参数\n7\n99999\n---\n15-07\nP.907\n用户登记参数\n8\n99999\n---\n15-08\nP.908\n用户登记参数\n9\n99999\n---\n15-09\nP.909\n用户登记参数\n10\n99999\n---\n15-10\nP.910\n用户登记参数\n11\n99999\n---\n15-11\nP.911\n用户登记参数\n12\n99999\n---\n15-12\nP.912\n用户登记参数\n13\n99999\n---\n15-13\nP.913\n用户登记参数\n14\n99999\n---\n15-14\nP.914\n用户登记参数\n15\n99999\n---\n15-15\nP.915\n用户登记参数\n16\n99999\n---\n15-16\nP.916\n用户登记参数\n17\n99999\n---\n15-17\nP.917\n用户登记参数\n18\n99999\n---\n15-18\nP.918\n用户登记参数\n19\n99999\n---\n15-19\nP.919\n用户登记参数\n20\n99999\n---" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "如何在变频器中设置用户登记参数?" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n287\n设定\n用户登记参数\n\n此参数组中设定的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/6\n时,不会被恢复出厂设定值。\n\n此参数组中设定的参数值为用户需要登记的参数号,被登记的参数号的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/\n6\n时,不会被恢复出厂设定值。\n\n恢复出厂值的设定请参照\n5.1.2\n参数管理部分。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n(\nP.7\n)\n,\n「顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的\n参数号为\n01-06\n,设定\n15-00=106\n。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n,\n「\n顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的参数号\n为\n01-06\n(\nP.7\n)\n,设定\n15-00=106\n。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "有哪些参数编号是可以设置的?" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n287\n设定\n用户登记参数\n\n此参数组中设定的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/6\n时,不会被恢复出厂设定值。\n\n此参数组中设定的参数值为用户需要登记的参数号,被登记的参数号的参数值,在执行\n00-02\n(P.996\n~\nP.999)=5/\n6\n时,不会被恢复出厂设定值。\n\n恢复出厂值的设定请参照\n5.1.2\n参数管理部分。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n(\nP.7\n)\n,\n「顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的\n参数号为\n01-06\n,设定\n15-00=106\n。\n注:请注意「顺序编号」或「参数组」模式下登记的参数号的区别。\n例如需要登记参数号\n01-06\n,\n「\n顺序编号」时,登记参数号为\nP.7\n,设定\nP.900=7\n;在「参数组」模式下,登记的参数号\n为\n01-06\n(\nP.7\n)\n,设定\n15-00=106\n。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "请提供参数编号P.902对应的默认设定值。" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n286\n5.16.1\n用户登记参数\n\n用户参数组用来登记用户不需要被恢复出厂值的参数的参数号。\n参数\n名称\n出厂值\n设定范围\n内容\n15-00\nP.900\n用户登记参数\n1\n99999\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n---\n15-01\nP.901\n用户登记参数\n2\n99999\n---\n15-02\nP.902\n用户登记参数\n3\n99999\n---\n15-03\nP.903\n用户登记参数\n4\n99999\n---\n15-04\nP.904\n用户登记参数\n5\n99999\n---\n15-05\nP.905\n用户登记参数\n6\n99999\n---\n15-06\nP.906\n用户登记参数\n7\n99999\n---\n15-07\nP.907\n用户登记参数\n8\n99999\n---\n15-08\nP.908\n用户登记参数\n9\n99999\n---\n15-09\nP.909\n用户登记参数\n10\n99999\n---\n15-10\nP.910\n用户登记参数\n11\n99999\n---\n15-11\nP.911\n用户登记参数\n12\n99999\n---\n15-12\nP.912\n用户登记参数\n13\n99999\n---\n15-13\nP.913\n用户登记参数\n14\n99999\n---\n15-14\nP.914\n用户登记参数\n15\n99999\n---\n15-15\nP.915\n用户登记参数\n16\n99999\n---\n15-16\nP.916\n用户登记参数\n17\n99999\n---\n15-17\nP.917\n用户登记参数\n18\n99999\n---\n15-18\nP.918\n用户登记参数\n19\n99999\n---\n15-19\nP.919\n用户登记参数\n20\n99999\n---" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "如何在变频器中查看或修改用户登记参数的数值?" }
{ "neg": [ "位置控制参数组\n12\n参数说明\n262\n参数\n组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n12-44\nP.474\n位置指令\n13\n的圈数\n-30000~30000\n0\n271\n12-45\nP.475\n位置指令\n13\n的脉冲数\n-30000~30000\n0\n271\n12-46\nP.476\n位置指令\n14\n的圈数\n-30000~30000\n0\n271\n12-47\nP.477\n位置指令\n14\n的脉冲数\n-30000~30000\n0\n271\n12-48\nP.478\n位置指令\n15\n的圈数\n-30000~30000\n0\n271\n12-49\nP.479\n位置指令\n15\n的脉冲数\n-30000~30000\n0\n271" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "参数组模式的范围是多少?" }
{ "neg": [ "保护参数组\n06\n参数说明\n177" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "请解释参数组模式的作用和用途。" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n286\n5.16.1\n用户登记参数\n\n用户参数组用来登记用户不需要被恢复出厂值的参数的参数号。\n参数\n名称\n出厂值\n设定范围\n内容\n15-00\nP.900\n用户登记参数\n1\n99999\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n---\n15-01\nP.901\n用户登记参数\n2\n99999\n---\n15-02\nP.902\n用户登记参数\n3\n99999\n---\n15-03\nP.903\n用户登记参数\n4\n99999\n---\n15-04\nP.904\n用户登记参数\n5\n99999\n---\n15-05\nP.905\n用户登记参数\n6\n99999\n---\n15-06\nP.906\n用户登记参数\n7\n99999\n---\n15-07\nP.907\n用户登记参数\n8\n99999\n---\n15-08\nP.908\n用户登记参数\n9\n99999\n---\n15-09\nP.909\n用户登记参数\n10\n99999\n---\n15-10\nP.910\n用户登记参数\n11\n99999\n---\n15-11\nP.911\n用户登记参数\n12\n99999\n---\n15-12\nP.912\n用户登记参数\n13\n99999\n---\n15-13\nP.913\n用户登记参数\n14\n99999\n---\n15-14\nP.914\n用户登记参数\n15\n99999\n---\n15-15\nP.915\n用户登记参数\n16\n99999\n---\n15-16\nP.916\n用户登记参数\n17\n99999\n---\n15-17\nP.917\n用户登记参数\n18\n99999\n---\n15-18\nP.918\n用户登记参数\n19\n99999\n---\n15-19\nP.919\n用户登记参数\n20\n99999\n---" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "如何将用户登记参数与特定功能或模式相关联?" }
{ "neg": [ "用户\n参数组\n15\n参数说明\n286\n5.16.1\n用户登记参数\n\n用户参数组用来登记用户不需要被恢复出厂值的参数的参数号。\n参数\n名称\n出厂值\n设定范围\n内容\n15-00\nP.900\n用户登记参数\n1\n99999\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n---\n15-01\nP.901\n用户登记参数\n2\n99999\n---\n15-02\nP.902\n用户登记参数\n3\n99999\n---\n15-03\nP.903\n用户登记参数\n4\n99999\n---\n15-04\nP.904\n用户登记参数\n5\n99999\n---\n15-05\nP.905\n用户登记参数\n6\n99999\n---\n15-06\nP.906\n用户登记参数\n7\n99999\n---\n15-07\nP.907\n用户登记参数\n8\n99999\n---\n15-08\nP.908\n用户登记参数\n9\n99999\n---\n15-09\nP.909\n用户登记参数\n10\n99999\n---\n15-10\nP.910\n用户登记参数\n11\n99999\n---\n15-11\nP.911\n用户登记参数\n12\n99999\n---\n15-12\nP.912\n用户登记参数\n13\n99999\n---\n15-13\nP.913\n用户登记参数\n14\n99999\n---\n15-14\nP.914\n用户登记参数\n15\n99999\n---\n15-15\nP.915\n用户登记参数\n16\n99999\n---\n15-16\nP.916\n用户登记参数\n17\n99999\n---\n15-17\nP.917\n用户登记参数\n18\n99999\n---\n15-18\nP.918\n用户登记参数\n19\n99999\n---\n15-19\nP.919\n用户登记参数\n20\n99999\n---" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "如何备份或恢复用户登记参数的设置?" }
{ "neg": [ "位置控制参数组\n12\n参数说明\n262\n参数\n组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n12-44\nP.474\n位置指令\n13\n的圈数\n-30000~30000\n0\n271\n12-45\nP.475\n位置指令\n13\n的脉冲数\n-30000~30000\n0\n271\n12-46\nP.476\n位置指令\n14\n的圈数\n-30000~30000\n0\n271\n12-47\nP.477\n位置指令\n14\n的脉冲数\n-30000~30000\n0\n271\n12-48\nP.478\n位置指令\n15\n的圈数\n-30000~30000\n0\n271\n12-49\nP.479\n位置指令\n15\n的脉冲数\n-30000~30000\n0\n271" ], "pos": [ "附录\n一:\n参数\n表\n附录\n359\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n15-00\nP.900\n用户登记参数\n1\nP\n参数模式:\n0\n~\n1299\n参数组模式:\n00-00~15-99\n99999\n286\n15-01\nP.901\n用户登记参数\n2\n99999\n286\n15-02\nP.902\n用户登记参数\n3\n99999\n286\n15-03\nP.903\n用户登记参数\n4\n99999\n286\n15-04\nP.904\n用户登记参数\n5\n99999\n286\n15-05\nP.905\n用户登记参数\n6\n99999\n286\n15-06\nP.906\n用户登记参数\n7\n99999\n286\n15-07\nP.907\n用户登记参数\n8\n99999\n286\n15-08\nP.908\n用户登记参数\n9\n99999\n286\n15-09\nP.909\n用户登记参数\n10\n99999\n286\n15-10\nP.910\n用户登记参数\n11\n99999\n286\n15-11\nP.911\n用户登记参数\n12\n99999\n286\n15-12\nP.912\n用户登记参数\n13\n99999\n286\n15-13\nP.913\n用户登记参数\n14\n99999\n286\n15-14\nP.914\n用户登记参数\n15\n99999\n286\n15-15\nP.915\n用户登记参数\n16\n99999\n286\n15-16\nP.916\n用户登记参数\n17\n99999\n286\n15-17\nP.917\n用户登记参数\n18\n99999\n286\n15-18\nP.918\n用户登记参数\n19\n99999\n286\n15-19\nP.919\n用户登记参数\n20\n99999\n286" ], "query": "请解释一下参数表中的页码是如何使用的。" }
{ "neg": [ "数位输\n入\n输\n出\n参数组\n03\n参数说明\n152\n范例:\n输入端子:\n设定\n03-00(P.83)\n=\n0\n(\nSTF\n)\n,\n正转信号\n;\n03-03(P.80)\n=\n5\n(\nM0\n)\n,\n类比\n4-5\n优先\n,\n其他端子\n预设\n设定出厂值\n,\n数位\n输入端子\nSTF\n和\nM0\n闭合后,变频器以\n4-5\n给定的频率正转运行,\n03-59(P.585)\n各位的状态如下,表示\nSTF\n,\nM\n0\n动作。\n所以\n03-59(P.585)\n=\n1\n×\n2\n2\n+\n0\n×\n2\n1\n+\n1\n×\n2\n0\n=\n5\n输出端子:\n03-50(A10)\n,\nRUN\n信号检出\n;\n03-57(A17)\n都设定为\n2\n(\nFU\n输出频率检出\n)\n,\n其他端子\n预设\n设定\n,\n扩充卡\n插入\nSLOT2\n,\n运转变频器到目标频率后,则\n03-62(P.588)\n各位状态如下图,表示\nA17\n,\nA10\n有输出。\n所以\n03-62(P.588)=1\n×\n2\n7\n+\n0\n×\n2\n6\n+\n0\n×\n2\n5\n+\n0\n×\n2\n4\n+\n0\n×\n2\n3\n+\n0\n×\n2\n2\n+\n0\n×\n2\n1\n+\n1\n×\n2\n0\n=\n129" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "请解释一下参数编号03-00代表的功能是什么?" }
{ "neg": [ "多段速\n参数组\n04\n参数说明\n156\n\n当\n04-03\n(P.24)\n~04-06\n(P.27)\n、\n04-07\n(P.142)\n~04-14\n(P.149)\n的参数设定值为\n99999\n时\n,\n目标频率由\nRL\n、\nRM\n、\nRH\n3\n个\n段速决定,如下表所示(端子优先权\nRL>RM>RH\n)\n:\n参数\n目标\n频率\n04-03(\nP.24)=\n99999\n04-04(\nP.25)=\n99999\n04-05(\nP.26)=\n99999\n04-06(\nP.27)=\n99999\n04-07\n(P.142\n)=9999\n9\n04-08(\nP.143)\n=9999\n9\n04-09(\nP.144)\n=9999\n9\n04-10(\nP.145)\n=9999\n9\n04-11(\nP.146)\n=9999\n9\n04-12(\nP.147)\n=9999\n9\n04-13(\nP.148)\n=9999\n9\n04-14(\nP.149)\n=9999\n9\nRL\n(\n04-02\n)\n○\n○\n○\n○\n○\n○\n○\n○\nRM\n(\n04-01\n)\n○\n○\n○\nRH\n(\n04-00\n)\n○\n例如:当\n04-05\n(P.26)\n=\n99999\n时,目标频率取决于\nRM\n(\n04-01\n(P.5)\n的设定值\n)\n。\n注:\n1.\n只有在「外部模式\n」\n、\n「混合模式\n2\n」或「混合模式\n4\n」下,才能使用多段速档位设定变频器的目标频率。\n2.\n本段落所提到的\nRL\n、\nRM\n、\nRH\n、\nREX\n为「多功能数位输入端子」的功能名称(例:\n03-03\n(P.80)\n=2\n,选择\nM0\n端\n子作为\nRL\n功能\n)\n。多功能数位输入端子的功能选择与功能,请参考\n03-03\n(P.80)\n、\n03-04\n(P.81)\n、\n03-05\n(P.82)\n、\n03-00\n(P.83)\n、\n03-01\n(P.84)\n、\n03-02\n(P.86)\n、\n03-06\n(P.126)\n、\n03-09\n(P.550)\n;相关配线,请参考\n3.5\n节。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "如何将变频器设置为多段速低速模式(RL)?" }
{ "neg": [ "各模式下的基本操作\n程式\n基本操作\n72\n4.3\n各模式下的基本操作程式\n4.3.1\nPU\n模式下,基本操作程式(\n00-16\n(P.79)\n=\n0\n或\n1\n)\n步骤\n描述\n1\n•\n切换操作模式至\nPU\n模式,此时指示灯\nPU\n会亮起\n。\n注:\n1.\n00-16(\nP.79)=0\n时,电源启动或变频器重置后,变频器会先处于外部模式。\n2.\n操作模式的选择与切换,请参考\n4.2\n节的内容。\n2\n•\n进入频率设定模式,并且将目标频率写入记忆体中。\n注:频率设定模式的操作流程,请参考\n4.2.4\n节的内容。\n3\n•\n按下\nFWD\n或\nREV\n后,\n马达\n开始运转。此时指示灯\nFWD\n或\nREV\n会闪烁,指示\n马达\n正在运转。且操作键盘会自动进入\n「监视模式\n」\n,显示当前稳定输出频率。\n注:\n1.\n监视模式的操作流程,请参考\n4.2.3\n节的内容。\n2.\n马达\n运转中,亦可进入频率设定模式,更改记忆体中的目标频率,以改变\n马达\n转速。\n4\n•\n按下\nRESET\nSTOP\n后,\n马达\n减速,直至停止。\n•\n变频器必须等到电压停止输出后,指示灯\nFWD\n或\nREV\n才会熄灭。\n4.3.2\n外部模式下,基本操作程式(\n00-16(P.79)\n=\n0\n或\n2\n)\n步骤\n描述\n1\n•\n切换操作模式至外部模式,操作键盘显示幕会显示\n,指示灯\nEXT\n会亮起。\n注\n:\n1.\n00-16(\nP.79)=0\n时\n,\n电源启动或变频器重置后\n,\n按\nMODE\n键切换到工作模式之\n「\n操作模式\n」\n下\n,\n变频器会先处于外部\n模式,然后用操作键盘的旋钮或上下键可切换到\nPU\n模式下;\n2.\n00-16(\nP.79)=2\n时,变频器永远处于外部模式;\n3.\n操作模式的选择与切换,请参考\n4.2\n节的内容。\n2\n•\n目标频率由外部端子设定\n(\n预设\n优先顺序由高到低\n)\n:\n•\n若选择程式运行模式,请参考\n5.4.1\n数位\n输入功能选择和\n5.5.2\n程式运行模式。\n•\n若目标频率由多段速档位设定,请参考第\n5\n章\n04-00(P.4)\n。\n•\n若目标频率由\nPG\n卡的\nA2/B2\n端子输入信号设定,请参考第\n5\n章\n09-07(P.356).\n•\n若目标频率由\nPWM\n脉冲输入设定,请参考\n5.4.1\n节。\n••\n若目标频率由\n2-5\n端子输入信号设定,请参考第\n5\n章\n02-09(P.38)\n。\n•\n若目标频率由\n4-5\n端子输入信号设定,请参考第\n5\n章\n02-21(P.39)\n。\n•\n若目标频率由\n3-5\n端子输入信号设定,请参考第\n5\n章\n02-30(P.508)\n。\n•\n若目标频率由\nHDI\n端子高速脉冲输入设定,请参考\n5.3.8\n节。\n3\n•\nSTF\n「\nturn\non\n」或\nSTR\n「\nturn\non\n」\n,则\n马达\n启动运转。\n•\n此时指示灯\nFWD\n或\nREV\n会闪烁,指示\n马达\n正在运转。\n注:\n1.\n启动端子\nSTF\n及\nSTR\n的设定,请参考\n5.1.8\n节\n00-15(\nP.78\n)\n及\n5.4.1\n数位\n输入功能选择。\n2.\n监视模式的操作流程,请参\n4.2.3\n节的内容。\n3.\n当选择程式运行模式时,\nSTF\n及\nSTR\n分别为启动信号和暂停信号,而非正反转端子。\n4\n•\nSTF\n「\nturn\noff\n」或\nSTR\n「\nturn\noff\n」后,\n马达\n减速,直到停止。\n•\n变频器必须等到电压停止输出后,指示灯\nFWD\n或\nREV\n才会熄灭。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "变频器的外部热继电器动作模式是什么?如何启用它?" }
{ "neg": [ "各模式下的基本操作\n程式\n基本操作\n72\n4.3\n各模式下的基本操作程式\n4.3.1\nPU\n模式下,基本操作程式(\n00-16\n(P.79)\n=\n0\n或\n1\n)\n步骤\n描述\n1\n•\n切换操作模式至\nPU\n模式,此时指示灯\nPU\n会亮起\n。\n注:\n1.\n00-16(\nP.79)=0\n时,电源启动或变频器重置后,变频器会先处于外部模式。\n2.\n操作模式的选择与切换,请参考\n4.2\n节的内容。\n2\n•\n进入频率设定模式,并且将目标频率写入记忆体中。\n注:频率设定模式的操作流程,请参考\n4.2.4\n节的内容。\n3\n•\n按下\nFWD\n或\nREV\n后,\n马达\n开始运转。此时指示灯\nFWD\n或\nREV\n会闪烁,指示\n马达\n正在运转。且操作键盘会自动进入\n「监视模式\n」\n,显示当前稳定输出频率。\n注:\n1.\n监视模式的操作流程,请参考\n4.2.3\n节的内容。\n2.\n马达\n运转中,亦可进入频率设定模式,更改记忆体中的目标频率,以改变\n马达\n转速。\n4\n•\n按下\nRESET\nSTOP\n后,\n马达\n减速,直至停止。\n•\n变频器必须等到电压停止输出后,指示灯\nFWD\n或\nREV\n才会熄灭。\n4.3.2\n外部模式下,基本操作程式(\n00-16(P.79)\n=\n0\n或\n2\n)\n步骤\n描述\n1\n•\n切换操作模式至外部模式,操作键盘显示幕会显示\n,指示灯\nEXT\n会亮起。\n注\n:\n1.\n00-16(\nP.79)=0\n时\n,\n电源启动或变频器重置后\n,\n按\nMODE\n键切换到工作模式之\n「\n操作模式\n」\n下\n,\n变频器会先处于外部\n模式,然后用操作键盘的旋钮或上下键可切换到\nPU\n模式下;\n2.\n00-16(\nP.79)=2\n时,变频器永远处于外部模式;\n3.\n操作模式的选择与切换,请参考\n4.2\n节的内容。\n2\n•\n目标频率由外部端子设定\n(\n预设\n优先顺序由高到低\n)\n:\n•\n若选择程式运行模式,请参考\n5.4.1\n数位\n输入功能选择和\n5.5.2\n程式运行模式。\n•\n若目标频率由多段速档位设定,请参考第\n5\n章\n04-00(P.4)\n。\n•\n若目标频率由\nPG\n卡的\nA2/B2\n端子输入信号设定,请参考第\n5\n章\n09-07(P.356).\n•\n若目标频率由\nPWM\n脉冲输入设定,请参考\n5.4.1\n节。\n••\n若目标频率由\n2-5\n端子输入信号设定,请参考第\n5\n章\n02-09(P.38)\n。\n•\n若目标频率由\n4-5\n端子输入信号设定,请参考第\n5\n章\n02-21(P.39)\n。\n•\n若目标频率由\n3-5\n端子输入信号设定,请参考第\n5\n章\n02-30(P.508)\n。\n•\n若目标频率由\nHDI\n端子高速脉冲输入设定,请参考\n5.3.8\n节。\n3\n•\nSTF\n「\nturn\non\n」或\nSTR\n「\nturn\non\n」\n,则\n马达\n启动运转。\n•\n此时指示灯\nFWD\n或\nREV\n会闪烁,指示\n马达\n正在运转。\n注:\n1.\n启动端子\nSTF\n及\nSTR\n的设定,请参考\n5.1.8\n节\n00-15(\nP.78\n)\n及\n5.4.1\n数位\n输入功能选择。\n2.\n监视模式的操作流程,请参\n4.2.3\n节的内容。\n3.\n当选择程式运行模式时,\nSTF\n及\nSTR\n分别为启动信号和暂停信号,而非正反转端子。\n4\n•\nSTF\n「\nturn\noff\n」或\nSTR\n「\nturn\noff\n」后,\n马达\n减速,直到停止。\n•\n变频器必须等到电压停止输出后,指示灯\nFWD\n或\nREV\n才会熄灭。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "如何将变频器设置为外部Reset功能模式(RES)?" }
{ "neg": [ "应用参数组\n10\n参数说明\n241\n如下图所示:\n注:设定了齿隙补偿时,加减速时间中仅中断时间部分变长。\n5.11.10\n三角波功能\nV/F\n\n依照一定的周期,通过三角波运行使频率产生振幅。\n参数\n名称\n出厂值\n设定范围\n内容\n10-23\nP.234\n三角波功能选择\n(摆频功能)\n0\n0\n无功能\n1\n外部\nTRI\n信号接通,三角波功能有效\n2\n在任何时候三角波功能都有效\n10-24\nP.235\n最大振幅量\n10.0%\n0\n~\n25.0%\n---\n10-25\nP.236\n减速时振幅补偿量\n10.0%\n0\n~\n50.0%\n---\n10-26\nP.237\n加速时振幅补偿量\n10.0%\n0\n~\n50.0%\n---\n10-27\nP.238\n振幅加速时间\n10.00s\n0\n~\n360.00s/\n0\n~\n3600.0s\n当\n01-08(P.21)\n=0\n时\n,\n10-27\n(\nP.238\n)\n,\n10-28\n(\nP.239\n)\n的单\n位为\n0.01s\n。\n10-28\nP.239\n振幅减速时间\n10.00s\n0\n~\n360.00s/\n0\n~\n3600.0s\n当\n01-08(P.21)\n=1\n时,\n10-27\n(\nP.238\n)\n,\n10-28\n(\nP.239\n)的单\n位为\n0.1s\n。\n设定\n三角波功能\n\n10-23(P.234)\n“\n三角波功能选择\n”\n=\n“\n1\n”\n的情况下接通三角波运行信号(\nTRI\n)\n,三角波功能有效。请将\n03-00(P.83)~03-05(P.82)\n、\n03-06(P.126)\n、\n03-09(P.550)\n“\n输入端子功能选择\n”\n中任意一个参数设置为\n“\n36\n”\n后,向数\n位输入端子分配\nTRI\n信号。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "请解释一下参数编号03-00中的TRI代表什么功能?" }
{ "neg": [ "多段速\n参数组\n04\n参数说明\n156\n\n当\n04-03\n(P.24)\n~04-06\n(P.27)\n、\n04-07\n(P.142)\n~04-14\n(P.149)\n的参数设定值为\n99999\n时\n,\n目标频率由\nRL\n、\nRM\n、\nRH\n3\n个\n段速决定,如下表所示(端子优先权\nRL>RM>RH\n)\n:\n参数\n目标\n频率\n04-03(\nP.24)=\n99999\n04-04(\nP.25)=\n99999\n04-05(\nP.26)=\n99999\n04-06(\nP.27)=\n99999\n04-07\n(P.142\n)=9999\n9\n04-08(\nP.143)\n=9999\n9\n04-09(\nP.144)\n=9999\n9\n04-10(\nP.145)\n=9999\n9\n04-11(\nP.146)\n=9999\n9\n04-12(\nP.147)\n=9999\n9\n04-13(\nP.148)\n=9999\n9\n04-14(\nP.149)\n=9999\n9\nRL\n(\n04-02\n)\n○\n○\n○\n○\n○\n○\n○\n○\nRM\n(\n04-01\n)\n○\n○\n○\nRH\n(\n04-00\n)\n○\n例如:当\n04-05\n(P.26)\n=\n99999\n时,目标频率取决于\nRM\n(\n04-01\n(P.5)\n的设定值\n)\n。\n注:\n1.\n只有在「外部模式\n」\n、\n「混合模式\n2\n」或「混合模式\n4\n」下,才能使用多段速档位设定变频器的目标频率。\n2.\n本段落所提到的\nRL\n、\nRM\n、\nRH\n、\nREX\n为「多功能数位输入端子」的功能名称(例:\n03-03\n(P.80)\n=2\n,选择\nM0\n端\n子作为\nRL\n功能\n)\n。多功能数位输入端子的功能选择与功能,请参考\n03-03\n(P.80)\n、\n03-04\n(P.81)\n、\n03-05\n(P.82)\n、\n03-00\n(P.83)\n、\n03-01\n(P.84)\n、\n03-02\n(P.86)\n、\n03-06\n(P.126)\n、\n03-09\n(P.550)\n;相关配线,请参考\n3.5\n节。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "变频器的多段速组合为十六段速(REX)模式如何配置?" }
{ "neg": [ "0\n~\n6000.0s\n0.0s\n159\n04-35\nP.111\n程式运行模式第一段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-36\nP.112\n程式运行模式第二段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-37\nP.113\n程式运行模式第三段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-38\nP.114\n程式运行模式第四段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-39\nP.115\n程式运行模式第五段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-40\nP.116\n程式运行模式第六段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-41\nP.117\n程式运行模式第七段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159\n04-42\nP.118\n程式运行模式第八段速加减速时间\n0\n~\n600.00s/0\n~\n6000.0s\n0.00s\n159" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "如何在外部模式下选择程式运行模式(PO)?" }
{ "neg": [ "各模式下的基本操作\n程式\n基本操作\n72\n4.3\n各模式下的基本操作程式\n4.3.1\nPU\n模式下,基本操作程式(\n00-16\n(P.79)\n=\n0\n或\n1\n)\n步骤\n描述\n1\n•\n切换操作模式至\nPU\n模式,此时指示灯\nPU\n会亮起\n。\n注:\n1.\n00-16(\nP.79)=0\n时,电源启动或变频器重置后,变频器会先处于外部模式。\n2.\n操作模式的选择与切换,请参考\n4.2\n节的内容。\n2\n•\n进入频率设定模式,并且将目标频率写入记忆体中。\n注:频率设定模式的操作流程,请参考\n4.2.4\n节的内容。\n3\n•\n按下\nFWD\n或\nREV\n后,\n马达\n开始运转。此时指示灯\nFWD\n或\nREV\n会闪烁,指示\n马达\n正在运转。且操作键盘会自动进入\n「监视模式\n」\n,显示当前稳定输出频率。\n注:\n1.\n监视模式的操作流程,请参考\n4.2.3\n节的内容。\n2.\n马达\n运转中,亦可进入频率设定模式,更改记忆体中的目标频率,以改变\n马达\n转速。\n4\n•\n按下\nRESET\nSTOP\n后,\n马达\n减速,直至停止。\n•\n变频器必须等到电压停止输出后,指示灯\nFWD\n或\nREV\n才会熄灭。\n4.3.2\n外部模式下,基本操作程式(\n00-16(P.79)\n=\n0\n或\n2\n)\n步骤\n描述\n1\n•\n切换操作模式至外部模式,操作键盘显示幕会显示\n,指示灯\nEXT\n会亮起。\n注\n:\n1.\n00-16(\nP.79)=0\n时\n,\n电源启动或变频器重置后\n,\n按\nMODE\n键切换到工作模式之\n「\n操作模式\n」\n下\n,\n变频器会先处于外部\n模式,然后用操作键盘的旋钮或上下键可切换到\nPU\n模式下;\n2.\n00-16(\nP.79)=2\n时,变频器永远处于外部模式;\n3.\n操作模式的选择与切换,请参考\n4.2\n节的内容。\n2\n•\n目标频率由外部端子设定\n(\n预设\n优先顺序由高到低\n)\n:\n•\n若选择程式运行模式,请参考\n5.4.1\n数位\n输入功能选择和\n5.5.2\n程式运行模式。\n•\n若目标频率由多段速档位设定,请参考第\n5\n章\n04-00(P.4)\n。\n•\n若目标频率由\nPG\n卡的\nA2/B2\n端子输入信号设定,请参考第\n5\n章\n09-07(P.356).\n•\n若目标频率由\nPWM\n脉冲输入设定,请参考\n5.4.1\n节。\n••\n若目标频率由\n2-5\n端子输入信号设定,请参考第\n5\n章\n02-09(P.38)\n。\n•\n若目标频率由\n4-5\n端子输入信号设定,请参考第\n5\n章\n02-21(P.39)\n。\n•\n若目标频率由\n3-5\n端子输入信号设定,请参考第\n5\n章\n02-30(P.508)\n。\n•\n若目标频率由\nHDI\n端子高速脉冲输入设定,请参考\n5.3.8\n节。\n3\n•\nSTF\n「\nturn\non\n」或\nSTR\n「\nturn\non\n」\n,则\n马达\n启动运转。\n•\n此时指示灯\nFWD\n或\nREV\n会闪烁,指示\n马达\n正在运转。\n注:\n1.\n启动端子\nSTF\n及\nSTR\n的设定,请参考\n5.1.8\n节\n00-15(\nP.78\n)\n及\n5.4.1\n数位\n输入功能选择。\n2.\n监视模式的操作流程,请参\n4.2.3\n节的内容。\n3.\n当选择程式运行模式时,\nSTF\n及\nSTR\n分别为启动信号和暂停信号,而非正反转端子。\n4\n•\nSTF\n「\nturn\noff\n」或\nSTR\n「\nturn\noff\n」后,\n马达\n减速,直到停止。\n•\n变频器必须等到电压停止输出后,指示灯\nFWD\n或\nREV\n才会熄灭。" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "变频器的外部Reset信号只在异警时有效(RES_E)模式如何配置?" }
{ "neg": [ "附录\n一:\n参数\n表\n附录\n299\n参数编号\n参数组\n参数名称\n设定范围\n出厂值\n参照\n页码\nP.83\n03-00\nSTF\n功能选择\n26\n:\nSTF+RT+RL+RM\n0\n139\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」时,\n马达\n反转;\nSTF/STR\n「\noff\n」\n,电\n机正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(结合\nRUN\n信号,\nSTF/STR\n端子可\n组\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)\n37\n:\nGP_BP\n(\n电源频率\n变频切换功能)\n38\n:\nCS\n(手动切换\n电源频率\n信号)\n39\n:\nSTF/STR\n+STOP\n(结合\nRUN\n信号,\nON\n时,\n马达\n反转;\nOFF\n时,先停车然后再\nRUN\n马达\n正转)\n40\n:\nP_MRS\n(变频器输出立即停止,此处\nMRS\n为脉冲信号输入)\n41\n:\nPWM\n设定频率(注\n1\n)\n42\n:保留\n43\n:\nRUN_EN\n(数位输入端子运转\n致能\n)\n44\n:\nPID_OFF\n数位输入端子关闭\nPID\n致能\n45\n:第二模式\n46\n:初始卷径选择\n1\n47\n:初始卷径选择\n2\n48\n:材料厚度选择\n1\n49\n:材料厚度选择\n2\n50\n:收放卷切换\n51\n:预驱动命令\n52\n:转矩记忆\n53\n:转矩记忆\n致能\n54\n:记圈信号(注\n1\n)\n55\n:切换速度\n/\n转矩控制\n56\n:卷径\n复归\n57\n:高速脉冲输入功能(注\n1\n)\n58\n:\n类比\n端子\n2-5\n优先\n59\n:\n类比\n端子\n3-5\n优先\n60\n:\nPLC\n的启动\n/\n停止\n61\n:原点复归\n致能\nSHOM\n62\n:原点复归设定原点\nORGP\n63\n:切换位置\n/\n速度控制\n64\n:外部切换零伺服\n65\n:外部加减速暂停\n66\n:外部强制停车\n67\n:卷径计算停止\n68\n:单点定位\n致能" ], "pos": [ "附录\n一:\n参数\n表\n附录\n335\n参数组\n参数编号\n参数名称\n设定范围\n出厂值\n参照\n页码\n03-00\nP.83\nSTF\n功能选择\n0\n:\nSTF\n(变频器正转)\n0\n139\n1\n:\nSTR\n(变频器反转)\n2\n:\nRL\n(多段速低速)\n3\n:\nRM\n(多段速中速)\n4\n:\nRH\n(多段速高速)\n5\n:\nAU\n(\n类比\n端子\n4-5\n优先)\n6\n:外部热继电器动作\n7\n:\nMRS\n(变频器输出立即停止)\n8\n:\nRT\n(变频器第二机能)\n9\n:\nEXT\n(外部点动)\n10\n:\nSTF+EXJ\n11\n:\nSTR+EXJ\n12\n:\nSTF+RT\n13\n:\nSTR+RT\n14\n:\nSTF+RL\n15\n:\nSTR+RL\n16\n:\nSTF+RM\n17\n:\nSTR+RM\n18\n:\nSTF+RH\n19\n:\nSTR+RH\n20\n:\nSTF+RL+RM\n21\n:\nSTR+RL+RM\n22\n:\nSTF+RT+RL\n23\n:\nSTR+RT+RL\n24\n:\nSTF+RT+RM\n25\n:\nSTR+RT+RM\n26\n:\nSTF+RT+RL+RM\n27\n:\nSTR+RT+RL+RM\n28\n:\nRUN\n(\n马达\n正转)\n29\n:\nSTF/STR\n(结合\nRUN\n信号使用,\nSTF/STR\n「\non\n」\n时\n,\n马达\n反转\n;\nSTF/STR\n「\noff\n」\n,\n马达\n正转)\n30\n:\nRES\n(外部\nReset\n功能)\n31\n:\nSTOP\n(\n结合\nRUN\n信号\n,\nSTF/STR\n端子可组\n合为三线功能)\n32\n:\nREX\n(多段速组合为十六段速)\n33\n:\nPO\n(外部模式下,选择程式运行模式)\n34\n:\nRES_E\n(外部\nReset\n信号只在异警时有效)\n35\n:\nMPO\n(外部模式下,手动回圈功能)\n36\n:\nTRI\n(三角波功能)" ], "query": "请解释一下参数编号03-00中的MPO代表什么功能?" }