did
int64
0
671
query
stringlengths
6
865
name
stringlengths
1
75
datatype
stringclasses
6 values
unit
stringclasses
5 values
IRDI
stringlengths
20
21
metalabel
int64
1
37
200
Nomenclature of goods according to the current regulation including the tariff and statistical nomenclature and the common Customs Tariff in the European Community. The structure of the number defines in the 1.-6. place the HS code of the WCO, in the 7.-8. the combined nomenclature of the European Community, in the 9.-10. the TARIC Code (Integrated Tariff of the European Communities) and in the 11th place a code for national purposes
customs tariff number (TARIC)
INTEGER
null
0173-1#02-AAD931#006
31
201
Nomenclature of goods in accordance with a regulation relating to customs tariff and statistical purposes for application to a specific country and / or region. The structure of the customs tariff number is defined by the type otherwise indicated
Customs tariff number
STRING
null
0173-1#02-AAZ800#001
1
202
Internationally applied 4 to 6-digit coding of classes of goods as defined by the Harmonized System (HS) of the World Customs Organization (WCO)
HS-Code of the WCO
INTEGER
null
0173-1#02-AAZ851#001
31
203
number of following subsystems
number of subsystems
INTEGER
null
0173-1#02-AAV964#001
31
204
name of the status / failure condition
name of status / failure condition
STRING_TRANSLATABLE
null
0173-1#02-AAV958#001
7
205
additional description of the status / failure condition
description
STRING_TRANSLATABLE
null
0173-1#02-AAV960#001
7
206
abbreviation for the used method
abbreviation of method
STRING_TRANSLATABLE
null
0173-1#02-AAV961#001
7
207
name of subsystem
name of subsystem
STRING_TRANSLATABLE
null
0173-1#02-AAV965#001
7
208
location of the asset
functional location
STRING_TRANSLATABLE
null
0173-1#02-AAV946#001
7
209
place of the asset
functional place
STRING_TRANSLATABLE
null
0173-1#02-AAV947#001
7
210
number of following references to subsystem
number of references to subsystem
INTEGER
null
0173-1#02-AAV966#001
31
211
unique identification of the PAM specification sheet
identification of the PAM specification sheet
STRING_TRANSLATABLE
null
0173-1#02-AAV929#001
7
212
electronic reference to the PAM specification sheet of the sub system
reference to the PAM specification sheet
STRING_TRANSLATABLE
null
0173-1#02-AAV967#001
7
213
number of following applicable methods
number of applicable methods
INTEGER
null
0173-1#02-AAV968#001
31
214
number of following static parameters
number of static parameters
INTEGER
null
0173-1#02-AAV977#001
31
215
name of the parameter
name of parameter
STRING_TRANSLATABLE
null
0173-1#02-AAV978#001
7
216
description of the static parameter
description
STRING_TRANSLATABLE
null
0173-1#02-AAV979#001
7
217
value, which leads to a message
value
REAL_TYPE
null
0173-1#02-AAV980#001
37
218
physical unit of the value or value range
unit
STRING_TRANSLATABLE
null
0173-1#02-AAV981#001
7
219
number of following generated signals of method
number of generated signals of method
INTEGER
null
0173-1#02-AAV982#001
31
220
name of the signal
name of signal
STRING_TRANSLATABLE
null
0173-1#02-AAV983#001
7
221
description of the output signals, which are generated by this method
description
STRING_TRANSLATABLE
null
0173-1#02-AAV984#001
7
222
value range of the generated signal
value range
null
null
0173-1#02-AAV985#001
13
223
highest relative humidity to which a device may be subject without permanent impairment of operating characteristics
max. air humidity
REAL_MEASURE
null
0173-1#02-AAN164#003
19
224
specification, if the generated signal should be archived in the PAM-System (historical data)
recording in the PAM system
STRING
null
0173-1#02-AAV986#001
1
225
analog or discrete signal type
type of signal
STRING
null
0173-1#02-AAV987#001
1
226
number of the following available, required sensors, devices
number of available, required sensors, devices
INTEGER
null
0173-1#02-AAV988#001
31
227
name of the input signal or measurement
name of input signal
STRING_TRANSLATABLE
null
0173-1#02-AAV989#001
7
228
description of the input signal or measurement to the method
description
STRING_TRANSLATABLE
null
0173-1#02-AAV990#001
7
229
value range for the required input signal or measurement
value range
null
null
0173-1#02-AAV991#001
13
230
input signal or measurement is required or not
required
STRING
null
0173-1#02-AAV992#001
1
231
input signal or measurement is available or not
available
STRING
null
0173-1#02-AAV993#001
1
232
upper limit of the temperature range of the surrounding space in which the component, the pipework or the system can be operated
max. ambient temperature
REAL_MEASURE
null
0173-1#02-BAA039#010
19
233
input signal or measurement should be archived in the PAM system (Historical Data) or not
recording in the PAM system
STRING
null
0173-1#02-AAV994#001
1
234
name of the method
name of method
STRING_TRANSLATABLE
null
0173-1#02-AAV969#001
7
235
abbreviation for the method
abbreviation of method
STRING_TRANSLATABLE
null
0173-1#02-AAV970#001
7
236
description of the method in plain text
short description for method
STRING_TRANSLATABLE
null
0173-1#02-AAV971#001
7
237
reference to the method sheet
identification of the method sheet
STRING_TRANSLATABLE
null
0173-1#02-AAV972#001
7
238
electronic reference to the method sheet
reference to the method sheet
STRING_TRANSLATABLE
null
0173-1#02-AAV976#001
7
239
method is allowed or required
required
STRING
null
0173-1#02-AAV973#001
1
240
online or offline implementation of the monitoring
online / offline function
STRING
null
0173-1#02-AAV974#001
1
241
interval of an offline monitoring or sampling time of an online monitoring
interval
REAL_MEASURE
null
0173-1#02-AAV975#002
19
242
lowest relative humidity to which a device may be subject without permanent impairment of operating characteristics
min. air humidity
REAL_MEASURE
null
0173-1#02-AAW976#002
19
243
category of the asset
type of general asset
STRING_TRANSLATABLE
null
0173-1#02-AAV939#001
7
244
unique identification of the PAM specification sheet for an asset type
identification of the type of general asset
STRING_TRANSLATABLE
null
0173-1#02-AAV940#001
7
245
marker for the criticality of the asset with respect to the process
criticality
STRING_TRANSLATABLE
null
0173-1#02-AAV941#001
7
246
marker for the safety class of the asset describing the safety class of the asset
SIL category
STRING
null
0173-1#02-AAV930#002
1
247
number of following additional information
number of additional information
INTEGER
null
0173-1#02-AAV955#001
31
248
title of the document with additional information
title
STRING_TRANSLATABLE
null
0173-1#02-AAV953#001
7
249
reference to the document with additional information
content
STRING_TRANSLATABLE
null
0173-1#02-AAV954#001
7
250
description of the main task of the asset
description
STRING_TRANSLATABLE
null
0173-1#02-AAV948#001
7
251
more detailed description of the asset type related to the general asset type
asset type
STRING_TRANSLATABLE
null
0173-1#02-AAV949#001
7
252
link to a specification sheet, which is independent of the PAM specification sheet
reference to the specification sheet
STRING_TRANSLATABLE
null
0173-1#02-AAV952#001
7
253
probability of failure defined by the user according to a FMEA or RCM analysis
probability of failure
STRING_TRANSLATABLE
null
0173-1#02-AAV942#001
7
254
impact of failure defined by the user according to a FMEA or RCM analysis
degree of failure
STRING_TRANSLATABLE
null
0173-1#02-AAV943#001
7
255
cost of a failure of this asset
cost of failure
STRING_TRANSLATABLE
null
0173-1#02-AAV928#001
7
256
Information about the value scale for the properties probability of failure and degree of failure
definition of the axis
STRING_TRANSLATABLE
null
0173-1#02-AAV944#001
7
257
general description of the tasks related to the Asset in the context of the process and the description of the PAM task
general task
STRING_TRANSLATABLE
null
0173-1#02-AAV956#001
7
258
number of following status / failure conditions
number of status / failure conditions
INTEGER
null
0173-1#02-AAV957#001
31
259
Minimum limit value of specific temperature during operation surrounding the operating unit
min. ambient temperature during operation
REAL_MEASURE
null
0173-1#02-AAC022#006
19
260
Specification of the adjustment mechanisms provided in the device
control types
STRING
null
0173-1#02-AAW268#001
1
261
additional information about the asset
remarks
STRING_TRANSLATABLE
null
0173-1#02-AAV995#001
7
262
number of the following users
number of users
INTEGER
null
0173-1#02-AAV996#001
31
263
quantitative expression of a point in time on a particular time scale
Date
null
null
0173-1#02-AAR969#002
13
264
person, who has created the document
author
STRING_TRANSLATABLE
null
0173-1#02-AAV997#001
7
265
person, who has checked the document
checked
STRING_TRANSLATABLE
null
0173-1#02-AAV999#001
7
266
person, who has released the document
released
STRING_TRANSLATABLE
null
0173-1#02-AAV998#001
7
267
version for the document identification
identification of document
STRING_TRANSLATABLE
null
0173-1#02-AAW000#001
7
268
name of the company
company
STRING_TRANSLATABLE
null
0173-1#02-AAW001#001
7
269
number of the following suppliers
number of suppliers
INTEGER
null
0173-1#02-AAW002#001
31
270
head observed at outlet area of the pump, corresponding to the sum of the height, pressure head and velocity head
total head at outlet area of the pump
REAL_MEASURE
null
0173-1#02-ABC216#001
19
271
rated flow at pump outlet connection divided by the inlet area of the pump
mean rated velocity at outlet
REAL_MEASURE
null
0173-1#02-ABC214#001
19
272
height of the centre of the outlet connection of the pump
height of the outlet connection
REAL_MEASURE
null
0173-1#02-ABC213#001
19
273
rated flow at pump inlet connection divided by the inlet area of the pump
mean rated velocity at inlet
REAL_MEASURE
null
0173-1#02-ABC218#001
19
274
inlet pressure of the operating conditions at the guarantee point
rated inlet pressure
REAL_MEASURE
null
0173-1#02-ABC219#001
19
275
height of the centre of the inlet connection of the pump
height of the inlet connection
REAL_MEASURE
null
0173-1#02-ABC217#001
19
276
Alphanumeric designation (starting with DN) of the size for components in a pipeline system, used for reference purposes
Nominal size of nozzle/pipe
STRING_TRANSLATABLE
null
0173-1#02-AAO341#002
7
277
degree of ingress protection offered by a housing or enclosure
enclosure type no/class
STRING_TRANSLATABLE
null
0173-1#02-AAN027#002
7
278
Relation of the amount of the active power to the false performance
Power factor (cos phi)
REAL_TYPE
null
0173-1#02-AAN420#001
37
279
The torque transferable via the operating medium
Torque at nominal speed, drive
REAL_MEASURE
null
0173-1#02-BAH949#004
19
280
lowest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used
minimum allowable inlet pressure
REAL_MEASURE
null
0173-1#02-ABC208#001
19
281
free cross-sectional area of the orifice in the outlet connection of the pump
outlet area of the pump
REAL_MEASURE
null
0173-1#02-ABC198#001
19
282
id of the asset to which the port is assigned
ID carrier
STRING
null
0173-1#02-ABC195#001
1
283
direction of the port
direction
STRING
null
0173-1#09-AAN669#001
1
284
describes the port type
category
STRING
null
0173-1#02-ABC193#001
1
285
actual redundant pumps within the pump system
redundant pump Ids
STRING
null
0173-1#02-ABC192#001
1
286
role respectively task of the pump within the multi pump management
pump role
STRING
null
0173-1#09-AAN665#001
1
287
pumps within the pump system
pump collective Ids
STRING
null
0173-1#02-ABC190#001
1
288
actual multi pump operation mode
operation mode
STRING
null
0173-1#09-AAN666#001
1
289
maximum number of pumps in operation. the difference between numpumps and maxnumpumpsop identifies the redundant pumps
maximum number of pumps in operation
INTEGER
null
0173-1#02-ABC188#001
31
290
determination of the time for the next exchange of the pump relative to exchangetime, if operator specific pump exchange mode is activated
exchange time difference
null
null
0173-1#02-ABC187#001
13
291
determination of the absolute time for the next exchange of the pump, if operator specific pump exchange mode is activated
exchange time
null
null
0173-1#02-ABC186#001
13
292
exchange mode of the pump
exchange mode
STRING
null
0173-1#09-AAN667#001
1
293
share of operation time of different pumps of the pump system in addition operation mode
distribution type
STRING
null
0173-1#09-AAN668#001
1
294
ascending order the priority of pumps in addition operation mode
distribution priority
STRING
null
0173-1#02-ABC183#001
1
295
Number
Number of Pumps
INTEGER
null
0173-1#02-AAV891#001
31
296
measured rate of flow at pump outlet connection divided by the outlet area of the pump
mean velocity at outlet
REAL_MEASURE
null
0173-1#02-ABC221#001
19
297
outlet pressure of the pump at the guarantee point with rated flow and rated speed, as well as rated inlet pressure, for rotodynamic pumps only
rated outlet pressure
REAL_MEASURE
null
0173-1#02-ABC215#001
19
298
interval time of a pump kick, if pump kick mode is operator specific. the time for the next pump kick results of the sum of pump kick time and pump kick time difference
pump kick time difference
null
null
0173-1#02-ABC145#001
13
299
absolute time of a pump kick, if pump kick mode is operator specific. the time for the next pump kick results of the sum of pump kick time and pump kick time difference
pump kick time
null
null
0173-1#02-ABC144#001
13