new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 9

Radiology Report Conditional 3D CT Generation with Multi Encoder Latent diffusion Model

Text to image latent diffusion models have recently advanced medical image synthesis, but applications to 3D CT generation remain limited. Existing approaches rely on simplified prompts, neglecting the rich semantic detail in full radiology reports, which reduces text image alignment and clinical fidelity. We propose Report2CT, a radiology report conditional latent diffusion framework for synthesizing 3D chest CT volumes directly from free text radiology reports, incorporating both findings and impression sections using multiple text encoder. Report2CT integrates three pretrained medical text encoders (BiomedVLP CXR BERT, MedEmbed, and ClinicalBERT) to capture nuanced clinical context. Radiology reports and voxel spacing information condition a 3D latent diffusion model trained on 20000 CT volumes from the CT RATE dataset. Model performance was evaluated using Frechet Inception Distance (FID) for real synthetic distributional similarity and CLIP based metrics for semantic alignment, with additional qualitative and quantitative comparisons against GenerateCT model. Report2CT generated anatomically consistent CT volumes with excellent visual quality and text image alignment. Multi encoder conditioning improved CLIP scores, indicating stronger preservation of fine grained clinical details in the free text radiology reports. Classifier free guidance further enhanced alignment with only a minor trade off in FID. We ranked first in the VLM3D Challenge at MICCAI 2025 on Text Conditional CT Generation and achieved state of the art performance across all evaluation metrics. By leveraging complete radiology reports and multi encoder text conditioning, Report2CT advances 3D CT synthesis, producing clinically faithful and high quality synthetic data.

  • 5 authors
·
Sep 17, 2025

Curriculum-Driven 3D CT Report Generation via Language-Free Visual Grafting and Zone-Constrained Compression

Automated radiology report generation from 3D computed tomography (CT) volumes is challenging due to extreme sequence lengths, severe class imbalance, and the tendency of large language models (LLMs) to ignore visual tokens in favor of linguistic priors. We present Ker-VLJEPA-3B, a four-phase curriculum learning framework for free-text report generation from thoracic CT volumes. A phased training curriculum progressively adapts a Llama 3.2 3B decoder to ground its output in visual features from a frozen, self-supervised encoder. Our visual backbone (LeJEPA ViT-Large) is trained via self-supervised joint-embedding prediction on unlabeled CTs, without text supervision. Unlike contrastive models (CLIP, BiomedCLIP), this language-free backbone yields modality-pure representations. Vision-language alignment is deferred to the curriculum's bridge and generation phases. This modality-agnostic design can integrate any self-supervised encoder into an LLM without paired text during foundation training. Methodological innovations include: (1) zone-constrained cross-attention compressing slice embeddings into 32 spatially-grounded visual tokens; (2) PCA whitening of anisotropic LLM embeddings; (3) a positive-findings-only strategy eliminating posterior collapse; (4) warm bridge initialization transferring projection weights; and (5) selective cross-attention freezing with elastic weight consolidation to prevent catastrophic forgetting. Evaluated on the CT-RATE benchmark (2,984 validation volumes, 18 classes), Ker-VLJEPA-3B achieves a macro F1 of 0.429, surpassing the state-of-the-art (U-VLM, macro F1 = 0.414) by 3.6%, and reaching 0.448 (+8.2%) with threshold optimization. Ablation studies confirm 56.6% of generation quality derives from patient-specific visual content. Code and weights are available.

  • 4 authors
·
Mar 24

DeepTumorVQA: A Hierarchical 3D CT Benchmark for Stage-Wise Evaluation of Medical VLMs and Tool-Augmented Agents

Medical vision-language models (VLMs) and AI agents have made significant progress in learning to analyze and reason about clinical images. However, existing medical visual question answering (VQA) benchmarks collapse model capabilities into a single accuracy score, obscuring where and why models fail. We propose DeepTumorVQA, a hierarchical benchmark that follows the multi-stage evidence chain in tumor diagnosis and decomposes 3D CT reasoning into four stages: recognition, measurement, visual reasoning, and medical reasoning. Higher-level questions remain independently scorable, while their ground-truth evidence chains are defined over lower-level primitives. The benchmark contains 476K questions across 42 clinical subtypes on 9,262 3D CT volumes. In addition to a direct reasoning mode for VLMs, DeepTumorVQA provides tool-interaction environments for agent evaluation, where a model can call external tools, including segmentation models, measurement programs, and medical knowledge modules, before answering the question. Evaluating over 30 model configurations, we find that reliable quantitative measurement is the primary bottleneck, making later-stage visual and medical reasoning harder for VLMs, while tool augmentation substantially mitigates this issue. When tools are available, leveraging medical knowledge and tools to reason about medical images becomes a new challenge. We further show that ground-truth step-by-step tool-use traces from DeepTumorVQA can supervise agents and reduce tool-use and reasoning failures. This stage-wise progression from recognition to measurement to visual and medical reasoning provides a concrete roadmap for future medical VLM and AI agent studies. All data and code are released at https://github.com/Schuture/DeepTumorVQA.

  • 10 authors
·
May 9

GenerateCT: Text-Guided 3D Chest CT Generation

Generative modeling has experienced substantial progress in recent years, particularly in text-to-image and text-to-video synthesis. However, the medical field has not yet fully exploited the potential of large-scale foundational models for synthetic data generation. In this paper, we introduce GenerateCT, the first method for text-conditional computed tomography (CT) generation, addressing the limitations in 3D medical imaging research and making our entire framework open-source. GenerateCT consists of a pre-trained large language model, a transformer-based text-conditional 3D chest CT generation architecture, and a text-conditional spatial super-resolution diffusion model. We also propose CT-ViT, which efficiently compresses CT volumes while preserving auto-regressiveness in-depth, enabling the generation of 3D CT volumes with variable numbers of axial slices. Our experiments demonstrate that GenerateCT can produce realistic, high-resolution, and high-fidelity 3D chest CT volumes consistent with medical language text prompts. We further investigate the potential of GenerateCT by training a model using generated CT volumes for multi-abnormality classification of chest CT volumes. Our contributions provide a valuable foundation for future research in text-conditional 3D medical image generation and have the potential to accelerate advancements in medical imaging research. Our code, pre-trained models, and generated data are available at https://github.com/ibrahimethemhamamci/GenerateCT.

  • 11 authors
·
May 25, 2023

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

Vision-language models (VLMs) achieve remarkable performance on 2D medical images, such as X-rays or pathology images, while 3D VLMs that directly process CT/MRI volumes lag behind due to limited 3D training data and the predominance of 2D foundation architectures. To leverage powerful 2D VLMs for analyzing medical volumes, which contain hundreds of slices, it is therefore necessary to focus only on those few slices, which are diagnostically relevant. To enable such a prioritization, we propose XGLASS, a method that transfers medical expertise from 2D X-rays to 3D CT for task-aware slice prioritization. XGLASS uses disease-conditioned importance maps derived from language-aligned radiologist gaze on X-rays and spatially aligns them with coronal CT projections, bringing gaze priors and CT content into a shared 2D representation. The fused gaze-prior/CT projection is then used to predict a disease-specific ordering of axial slices, prioritizing diagnostically relevant slices. XGLASS significantly improves budgeted retrieval over 2D and 3D-native baselines, achieving a top-10 hit rate up to 75.9% for the best-performing disease. In practice, this means that after inspecting only the top 10 slices (4.17% of a 240-slice scan), XGLASS identifies a diagnostically relevant slice in more than 75% of cases. For downstream slice-wise finding classification, an XGLASS-selected 30-slice candidate set reduces model calls by 87.5% while improving F1 by 11.3 percentage points over all-slice inference, 4.2 points over the strongest 2D selector, and remains competitive with 3D-native selectors while requiring up to 130.8 times less time and 10.9 times less GPU memory per finding, supporting its use as a lightweight preselector for volumetric CT analysis. The code and pretrained checkpoint are available on https://github.com/michaelgloeckler/XGLASS.

  • 2 authors
·
Oct 18

Structured Spectral Graph Representation Learning for Multi-label Abnormality Analysis from 3D CT Scans

With the growing volume of CT examinations, there is an increasing demand for automated tools such as organ segmentation, abnormality detection, and report generation to support radiologists in managing their clinical workload. Multi-label classification of 3D Chest CT scans remains a critical yet challenging problem due to the complex spatial relationships inherent in volumetric data and the wide variability of abnormalities. Existing methods based on 3D convolutional neural networks struggle to capture long-range dependencies, while Vision Transformers often require extensive pre-training on large-scale, domain-specific datasets to perform competitively. In this work of academic research, we propose a 2.5D alternative by introducing a new graph-based framework that represents 3D CT volumes as structured graphs, where axial slice triplets serve as nodes processed through spectral graph convolution, enabling the model to reason over inter-slice dependencies while maintaining complexity compatible with clinical deployment. Our method, trained and evaluated on 3 datasets from independent institutions, achieves strong cross-dataset generalization, and shows competitive performance compared to state-of-the-art visual encoders. We further conduct comprehensive ablation studies to evaluate the impact of various aggregation strategies, edge-weighting schemes, and graph connectivity patterns. Additionally, we demonstrate the broader applicability of our approach through transfer experiments on automated radiology report generation and abdominal CT data.

  • 4 authors
·
Oct 12, 2025

MIS-FM: 3D Medical Image Segmentation using Foundation Models Pretrained on a Large-Scale Unannotated Dataset

Pretraining with large-scale 3D volumes has a potential for improving the segmentation performance on a target medical image dataset where the training images and annotations are limited. Due to the high cost of acquiring pixel-level segmentation annotations on the large-scale pretraining dataset, pretraining with unannotated images is highly desirable. In this work, we propose a novel self-supervised learning strategy named Volume Fusion (VF) for pretraining 3D segmentation models. It fuses several random patches from a foreground sub-volume to a background sub-volume based on a predefined set of discrete fusion coefficients, and forces the model to predict the fusion coefficient of each voxel, which is formulated as a self-supervised segmentation task without manual annotations. Additionally, we propose a novel network architecture based on parallel convolution and transformer blocks that is suitable to be transferred to different downstream segmentation tasks with various scales of organs and lesions. The proposed model was pretrained with 110k unannotated 3D CT volumes, and experiments with different downstream segmentation targets including head and neck organs, thoracic/abdominal organs showed that our pretrained model largely outperformed training from scratch and several state-of-the-art self-supervised training methods and segmentation models. The code and pretrained model are available at https://github.com/openmedlab/MIS-FM.

  • 6 authors
·
Jun 29, 2023

A Skull-Adaptive Framework for AI-Based 3D Transcranial Focused Ultrasound Simulation

Transcranial focused ultrasound (tFUS) is an emerging modality for non-invasive brain stimulation and therapeutic intervention, offering millimeter-scale spatial precision and the ability to target deep brain structures. However, the heterogeneous and anisotropic nature of the human skull introduces significant distortions to the propagating ultrasound wavefront, which require time-consuming patient-specific planning and corrections using numerical solvers for accurate targeting. To enable data-driven approaches in this domain, we introduce TFUScapes, the first large-scale, high-resolution dataset of tFUS simulations through anatomically realistic human skulls derived from T1-weighted MRI images. We have developed a scalable simulation engine pipeline using the k-Wave pseudo-spectral solver, where each simulation returns a steady-state pressure field generated by a focused ultrasound transducer placed at realistic scalp locations. In addition to the dataset, we present DeepTFUS, a deep learning model that estimates normalized pressure fields directly from input 3D CT volumes and transducer position. The model extends a U-Net backbone with transducer-aware conditioning, incorporating Fourier-encoded position embeddings and MLP layers to create global transducer embeddings. These embeddings are fused with U-Net encoder features via feature-wise modulation, dynamic convolutions, and cross-attention mechanisms. The model is trained using a combination of spatially weighted and gradient-sensitive loss functions, enabling it to approximate high-fidelity wavefields. The TFUScapes dataset is publicly released to accelerate research at the intersection of computational acoustics, neurotechnology, and deep learning. The project page is available at https://github.com/CAMMA-public/TFUScapes.

  • 6 authors
·
May 19, 2025

Resolution Meets Reduction: Efficient Visual Context for 3D Radiology Report Generation

Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges. Modern foundation vision encoders (VEs) can produce tens of thousands of vision tokens per scan, making the visual sequence passed to the large language model (LLM) a primary computational bottleneck. Vision-to-language projectors can compress this sequence to reduce computation, but may discard clinically relevant detail; conversely, effective compression can accommodate higher-resolution inputs while keeping the downstream token count fixed. How this vision-token budget should be allocated across input field of view, spatial resolution, and vision-to-language projection therefore remains an open design question. We systematically evaluate four heterogeneous VEs (CNN- and ViT-based), five token-reducing projectors at up to 64x compression alongside a non-reducing MLP projector baseline, and five instruction-tuned LLMs (1.7B--4B) on two large-scale CT report datasets (CT-RATE and Merlin). At matched LLM token budgets, anatomy-guided region of interest cropping is the most consistent strategy, improving clinical macro F1 in 19 of 20 settings by +3.7 points on average for the 3D ViT Primus encoder and +1.1 for the slice-based 2D ViT Curia encoder. Increasing input resolution further is strongly projector-dependent: the PerceiverResampler, paired with higher-resolution Curia features, yields the strongest configuration in the resolution study on both datasets. Our best configurations achieve state-of-the-art clinical macro F1 on the test sets, reaching 49.5 on CT-RATE and 49.0 on Merlin. Code and models will be published upon publication.

  • 13 authors
·
Aug 8

GLINT: Sparsely Gated Vision-Language Alignment for Fine-Grained Radiology Representations

Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows. However, this pairing reveals a mismatch in scale: each finding occupies only a small region of the image, yet supervision is provided only at the global image-report level. This poses a central challenge: prior approaches spread weight densely across all patches rather than concentrating on the sparse subset relevant to a given query. To address this, we present GLINT (Gated Language-Image alignmeNT), a framework that explicitly models this sparse correspondence. On the alignment side, we introduce Sparsely Gated Alignment, a novel architecture in which a sigmoid gate over a separate gate embedding space activates only the patches relevant to each textual query, enforcing explicit sparsity. On the representation side, we add Dense Feature Regularization, which anchors the trainable encoder's intermediate features to a frozen self-supervised learning (SSL) teacher, preserving the fine-grained patch features that the gate relies on. The same recipe applies to both 2D chest X-ray (CXR) and 3D chest computed tomography (CT), built with DINOv3 and V-JEPA 2.1, respectively. GLINT enables zero-shot classification, grounding, and segmentation from free-text queries, and to our knowledge is the first to demonstrate zero-shot segmentation on 3D CT volumes without mask supervision. Notably, the most pronounced gains arise on zero-shot grounding and segmentation, where sparse, query-specific localization is required, consistent with our design intent. In downstream evaluation, GLINT outperforms both SSL encoders and medical VLMs on classification, report generation, and segmentation.

  • 9 authors
·
Jun 1

AnyCXR: Human Anatomy Segmentation of Chest X-ray at Any Acquisition Position using Multi-stage Domain Randomized Synthetic Data with Imperfect Annotations and Conditional Joint Annotation Regularization Learning

Robust anatomical segmentation of chest X-rays (CXRs) remains challenging due to the scarcity of comprehensive annotations and the substantial variability of real-world acquisition conditions. We propose AnyCXR, a unified framework that enables generalizable multi-organ segmentation across arbitrary CXR projection angles using only synthetic supervision. The method combines a Multi-stage Domain Randomization (MSDR) engine, which generates over 100,000 anatomically faithful and highly diverse synthetic radiographs from 3D CT volumes, with a Conditional Joint Annotation Regularization (CAR) learning strategy that leverages partial and imperfect labels by enforcing anatomical consistency in a latent space. Trained entirely on synthetic data, AnyCXR achieves strong zero-shot generalization on multiple real-world datasets, providing accurate delineation of 54 anatomical structures in PA, lateral, and oblique views. The resulting segmentation maps support downstream clinical tasks, including automated cardiothoracic ratio estimation, spine curvature assessment, and disease classification, where the incorporation of anatomical priors improves diagnostic performance. These results demonstrate that AnyCXR establishes a scalable and reliable foundation for anatomy-aware CXR analysis and offers a practical pathway toward reducing annotation burdens while improving robustness across diverse imaging conditions.

  • 6 authors
·
Jan 1

Parameter-Efficient Adaptation of SAM 3 for Automated ITV Generation from 4DCT Images

Four-dimensional computed tomography (4DCT) captures the full respiratory cycle of thoracic anatomy, yet current Internal Target Volume contouring workflows process each phase in isolation, discarding temporal coherence and leaving contours vulnerable to phase-specific artifacts. We present a lightweight framework that applies parameter-efficient fine-tuning to the Segment Anything Model 3 (SAM 3) via low-rank adaptation (LoRA) to align its text-prompted segmentation with the medical domain using only seven annotated 3D CT volumes. Furthermore, the framework incorporates a hard negative mining strategy to improve boundary discrimination in low-contrast thoracic regions. At inference, phase-wise predictions are refined through phase-coherent temporal filtering and spatial connectivity analysis. Since respiratory motion is continuous and periodic, genuine anatomy appears in contiguous blocks of phases, whereas transient artifacts appear sporadically and are thus effectively suppressed. Experiments on pulmonary and cardiac structures yield median Dice scores of 0.968 and 0.910 with 95th-percentile Hausdorff distances of 0.998 mm and 2.931 mm, respectively. The proposed framework effectively eliminates the severe false-positive predictions inherent in the zero-shot inference of the unadapted SAM 3. With only seven annotated volumes, the framework retains over 95% of full-data accuracy, and the entire pipeline is trainable on a single consumer-grade GPU, demonstrating a scalable, data-efficient solution for adaptive radiotherapy.

  • 1 authors
·
Jun 13

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

  • 4 authors
·
Aug 27

Vision-Language Models for Automated 3D PET/CT Report Generation

Positron emission tomography/computed tomography (PET/CT) is essential in oncology, yet the rapid expansion of scanners has outpaced the availability of trained specialists, making automated PET/CT report generation (PETRG) increasingly important for reducing clinical workload. Compared with structural imaging (e.g., X-ray, CT, and MRI), functional PET poses distinct challenges: metabolic patterns vary with tracer physiology, and whole-body 3D contextual information is required rather than local-region interpretation. To advance PETRG, we propose PETRG-3D, an end-to-end 3D dual-branch framework that separately encodes PET and CT volumes and incorporates style-adaptive prompts to mitigate inter-hospital variability in reporting practices. We construct PETRG-Lym, a multi-center lymphoma dataset collected from four hospitals (824 reports w/ 245,509 paired PET/CT slices), and construct AutoPET-RG-Lym, a publicly accessible PETRG benchmark derived from open imaging data but equipped with new expert-written, clinically validated reports (135 cases). To assess clinical utility, we introduce PETRG-Score, a lymphoma-specific evaluation protocol that jointly measures metabolic and structural findings across curated anatomical regions. Experiments show that PETRG-3D substantially outperforms existing methods on both natural language metrics (e.g., +31.49\% ROUGE-L) and clinical efficacy metrics (e.g., +8.18\% PET-All), highlighting the benefits of volumetric dual-modality modeling and style-aware prompting. Overall, this work establishes a foundation for future PET/CT-specific models emphasizing disease-aware reasoning and clinically reliable evaluation. Codes, models, and AutoPET-RG-Lym will be released.

  • 11 authors
·
Nov 24, 2025

PETAR: Localized Findings Generation with Mask-Aware Vision-Language Modeling for PET Automated Reporting

Generating automated reports for 3D positron emission tomography (PET) is an important and challenging task in medical imaging. PET plays a vital role in oncology, but automating report generation is difficult due to the complexity of whole-body 3D volumes, the wide range of potential clinical findings, and the limited availability of annotated datasets. To address these challenges, we introduce PETARSeg-11K, the first large-scale, publicly available dataset that provides lesion-level correspondence between 3D PET/CT volumes and free-text radiological findings. It comprises 11,356 lesion descriptions paired with 3D segmentations. Second, we propose PETAR-4B, a 3D vision-language model designed for mask-aware, spatially grounded PET/CT reporting. PETAR-4B jointly encodes PET, CT, and 3D lesion segmentation masks, using a 3D focal prompt to capture fine-grained details of lesions that normally comprise less than 0.1% of the volume. Evaluations using automated metrics show PETAR-4B substantially outperforming all 2D and 3D baselines. A human study involving five physicians -- the first of its kind for automated PET reporting -- confirms the model's clinical utility and establishes correlations between automated metrics and expert judgment. This work provides a foundational dataset and a novel architecture, advancing 3D medical vision-language understanding in PET.

  • 14 authors
·
Nov 29, 2025

Head and Neck Tumor Segmentation from [18F]F-FDG PET/CT Images Based on 3D Diffusion Model

Head and neck (H&N) cancers are among the most prevalent types of cancer worldwide, and [18F]F-FDG PET/CT is widely used for H&N cancer management. Recently, the diffusion model has demonstrated remarkable performance in various image-generation tasks. In this work, we proposed a 3D diffusion model to accurately perform H&N tumor segmentation from 3D PET and CT volumes. The 3D diffusion model was developed considering the 3D nature of PET and CT images acquired. During the reverse process, the model utilized a 3D UNet structure and took the concatenation of PET, CT, and Gaussian noise volumes as the network input to generate the tumor mask. Experiments based on the HECKTOR challenge dataset were conducted to evaluate the effectiveness of the proposed diffusion model. Several state-of-the-art techniques based on U-Net and Transformer structures were adopted as the reference methods. Benefits of employing both PET and CT as the network input as well as further extending the diffusion model from 2D to 3D were investigated based on various quantitative metrics and the uncertainty maps generated. Results showed that the proposed 3D diffusion model could generate more accurate segmentation results compared with other methods. Compared to the diffusion model in 2D format, the proposed 3D model yielded superior results. Our experiments also highlighted the advantage of utilizing dual-modality PET and CT data over only single-modality data for H&N tumor segmentation.

  • 2 authors
·
Jan 30, 2024

Advancing Multimodal Medical Capabilities of Gemini

Many clinical tasks require an understanding of specialized data, such as medical images and genomics, which is not typically found in general-purpose large multimodal models. Building upon Gemini's multimodal models, we develop several models within the new Med-Gemini family that inherit core capabilities of Gemini and are optimized for medical use via fine-tuning with 2D and 3D radiology, histopathology, ophthalmology, dermatology and genomic data. Med-Gemini-2D sets a new standard for AI-based chest X-ray (CXR) report generation based on expert evaluation, exceeding previous best results across two separate datasets by an absolute margin of 1% and 12%, where 57% and 96% of AI reports on normal cases, and 43% and 65% on abnormal cases, are evaluated as "equivalent or better" than the original radiologists' reports. We demonstrate the first ever large multimodal model-based report generation for 3D computed tomography (CT) volumes using Med-Gemini-3D, with 53% of AI reports considered clinically acceptable, although additional research is needed to meet expert radiologist reporting quality. Beyond report generation, Med-Gemini-2D surpasses the previous best performance in CXR visual question answering (VQA) and performs well in CXR classification and radiology VQA, exceeding SoTA or baselines on 17 of 20 tasks. In histopathology, ophthalmology, and dermatology image classification, Med-Gemini-2D surpasses baselines across 18 out of 20 tasks and approaches task-specific model performance. Beyond imaging, Med-Gemini-Polygenic outperforms the standard linear polygenic risk score-based approach for disease risk prediction and generalizes to genetically correlated diseases for which it has never been trained. Although further development and evaluation are necessary in the safety-critical medical domain, our results highlight the potential of Med-Gemini across a wide range of medical tasks.

  • 47 authors
·
May 6, 2024

Text-to-CT Generation via 3D Latent Diffusion Model with Contrastive Vision-Language Pretraining

Objective: While recent advances in text-conditioned generative models have enabled the synthesis of realistic medical images, progress has been largely confined to 2D modalities such as chest X-rays. Extending text-to-image generation to volumetric Computed Tomography (CT) remains a significant challenge, due to its high dimensionality, anatomical complexity, and the absence of robust frameworks that align vision-language data in 3D medical imaging. Methods: We introduce a novel architecture for Text-to-CT generation that combines a latent diffusion model with a 3D contrastive vision-language pretraining scheme. Our approach leverages a dual-encoder CLIP-style model trained on paired CT volumes and radiology reports to establish a shared embedding space, which serves as the conditioning input for generation. CT volumes are compressed into a low-dimensional latent space via a pretrained volumetric VAE, enabling efficient 3D denoising diffusion without requiring external super-resolution stages. Results: We evaluate our method on the CT-RATE dataset and conduct a comprehensive assessment of image fidelity, clinical relevance, and semantic alignment. Our model achieves competitive performance across all tasks, significantly outperforming prior baselines for text-to-CT generation. Moreover, we demonstrate that CT scans synthesized by our framework can effectively augment real data, improving downstream diagnostic performance. Conclusion: Our results show that modality-specific vision-language alignment is a key component for high-quality 3D medical image generation. By integrating contrastive pretraining and volumetric diffusion, our method offers a scalable and controllable solution for synthesizing clinically meaningful CT volumes from text, paving the way for new applications in data augmentation, medical education, and automated clinical simulation.

  • 5 authors
·
May 31, 2025

H-DenseUNet: Hybrid Densely Connected UNet for Liver and Tumor Segmentation from CT Volumes

Liver cancer is one of the leading causes of cancer death. To assist doctors in hepatocellular carcinoma diagnosis and treatment planning, an accurate and automatic liver and tumor segmentation method is highly demanded in the clinical practice. Recently, fully convolutional neural networks (FCNs), including 2D and 3D FCNs, serve as the back-bone in many volumetric image segmentation. However, 2D convolutions can not fully leverage the spatial information along the third dimension while 3D convolutions suffer from high computational cost and GPU memory consumption. To address these issues, we propose a novel hybrid densely connected UNet (H-DenseUNet), which consists of a 2D DenseUNet for efficiently extracting intra-slice features and a 3D counterpart for hierarchically aggregating volumetric contexts under the spirit of the auto-context algorithm for liver and tumor segmentation. We formulate the learning process of H-DenseUNet in an end-to-end manner, where the intra-slice representations and inter-slice features can be jointly optimized through a hybrid feature fusion (HFF) layer. We extensively evaluated our method on the dataset of MICCAI 2017 Liver Tumor Segmentation (LiTS) Challenge and 3DIRCADb Dataset. Our method outperformed other state-of-the-arts on the segmentation results of tumors and achieved very competitive performance for liver segmentation even with a single model.

  • 6 authors
·
Sep 21, 2017

MedNeXt-v2: Scaling 3D ConvNeXts for Large-Scale Supervised Representation Learning in Medical Image Segmentation

Large-scale supervised pretraining is rapidly reshaping 3D medical image segmentation. However, existing efforts focus primarily on increasing dataset size and overlook the question of whether the backbone network is an effective representation learner at scale. In this work, we address this gap by revisiting ConvNeXt-based architectures for volumetric segmentation and introducing MedNeXt-v2, a compound-scaled 3D ConvNeXt that leverages improved micro-architecture and data scaling to deliver state-of-the-art performance. First, we show that routinely used backbones in large-scale pretraining pipelines are often suboptimal. Subsequently, we use comprehensive backbone benchmarking prior to scaling and demonstrate that stronger from scratch performance reliably predicts stronger downstream performance after pretraining. Guided by these findings, we incorporate a 3D Global Response Normalization module and use depth, width, and context scaling to improve our architecture for effective representation learning. We pretrain MedNeXt-v2 on 18k CT volumes and demonstrate state-of-the-art performance when fine-tuning across six challenging CT and MR benchmarks (144 structures), showing consistent gains over seven publicly released pretrained models. Beyond improvements, our benchmarking of these models also reveals that stronger backbones yield better results on similar data, representation scaling disproportionately benefits pathological segmentation, and that modality-specific pretraining offers negligible benefit once full finetuning is applied. In conclusion, our results establish MedNeXt-v2 as a strong backbone for large-scale supervised representation learning in 3D Medical Image Segmentation. Our code and pretrained models are made available with the official nnUNet repository at: https://www.github.com/MIC-DKFZ/nnUNet

  • 7 authors
·
Dec 19, 2025

Are Vision Language Models Ready for Clinical Diagnosis? A 3D Medical Benchmark for Tumor-centric Visual Question Answering

Vision-Language Models (VLMs) have shown promise in various 2D visual tasks, yet their readiness for 3D clinical diagnosis remains unclear due to stringent demands for recognition precision, reasoning ability, and domain knowledge. To systematically evaluate these dimensions, we present DeepTumorVQA, a diagnostic visual question answering (VQA) benchmark targeting abdominal tumors in CT scans. It comprises 9,262 CT volumes (3.7M slices) from 17 public datasets, with 395K expert-level questions spanning four categories: Recognition, Measurement, Visual Reasoning, and Medical Reasoning. DeepTumorVQA introduces unique challenges, including small tumor detection and clinical reasoning across 3D anatomy. Benchmarking four advanced VLMs (RadFM, M3D, Merlin, CT-CHAT), we find current models perform adequately on measurement tasks but struggle with lesion recognition and reasoning, and are still not meeting clinical needs. Two key insights emerge: (1) large-scale multimodal pretraining plays a crucial role in DeepTumorVQA testing performance, making RadFM stand out among all VLMs. (2) Our dataset exposes critical differences in VLM components, where proper image preprocessing and design of vision modules significantly affect 3D perception. To facilitate medical multimodal research, we have released DeepTumorVQA as a rigorous benchmark: https://github.com/Schuture/DeepTumorVQA.

  • 8 authors
·
May 24, 2025

RadRotator: 3D Rotation of Radiographs with Diffusion Models

Transforming two-dimensional (2D) images into three-dimensional (3D) volumes is a well-known yet challenging problem for the computer vision community. In the medical domain, a few previous studies attempted to convert two or more input radiographs into computed tomography (CT) volumes. Following their effort, we introduce a diffusion model-based technology that can rotate the anatomical content of any input radiograph in 3D space, potentially enabling the visualization of the entire anatomical content of the radiograph from any viewpoint in 3D. Similar to previous studies, we used CT volumes to create Digitally Reconstructed Radiographs (DRRs) as the training data for our model. However, we addressed two significant limitations encountered in previous studies: 1. We utilized conditional diffusion models with classifier-free guidance instead of Generative Adversarial Networks (GANs) to achieve higher mode coverage and improved output image quality, with the only trade-off being slower inference time, which is often less critical in medical applications; and 2. We demonstrated that the unreliable output of style transfer deep learning (DL) models, such as Cycle-GAN, to transfer the style of actual radiographs to DRRs could be replaced with a simple yet effective training transformation that randomly changes the pixel intensity histograms of the input and ground-truth imaging data during training. This transformation makes the diffusion model agnostic to any distribution variations of the input data pixel intensity, enabling the reliable training of a DL model on input DRRs and applying the exact same model to conventional radiographs (or DRRs) during inference.

  • 7 authors
·
Apr 19, 2024

MInDI-3D: Iterative Deep Learning in 3D for Sparse-view Cone Beam Computed Tomography

We present MInDI-3D (Medical Inversion by Direct Iteration in 3D), the first 3D conditional diffusion-based model for real-world sparse-view Cone Beam Computed Tomography (CBCT) artefact removal, aiming to reduce imaging radiation exposure. A key contribution is extending the "InDI" concept from 2D to a full 3D volumetric approach for medical images, implementing an iterative denoising process that refines the CBCT volume directly from sparse-view input. A further contribution is the generation of a large pseudo-CBCT dataset (16,182) from chest CT volumes of the CT-RATE public dataset to robustly train MInDI-3D. We performed a comprehensive evaluation, including quantitative metrics, scalability analysis, generalisation tests, and a clinical assessment by 11 clinicians. Our results show MInDI-3D's effectiveness, achieving a 12.96 (6.10) dB PSNR gain over uncorrected scans with only 50 projections on the CT-RATE pseudo-CBCT (independent real-world) test set and enabling an 8x reduction in imaging radiation exposure. We demonstrate its scalability by showing that performance improves with more training data. Importantly, MInDI-3D matches the performance of a 3D U-Net on real-world scans from 16 cancer patients across distortion and task-based metrics. It also generalises to new CBCT scanner geometries. Clinicians rated our model as sufficient for patient positioning across all anatomical sites and found it preserved lung tumour boundaries well.

  • 10 authors
·
Aug 13, 2025

On the Evaluation of Prohibited Item Classification and Detection in Volumetric 3D Computed Tomography Baggage Security Screening Imagery

X-ray Computed Tomography (CT) based 3D imaging is widely used in airports for aviation security screening whilst prior work on prohibited item detection focuses primarily on 2D X-ray imagery. In this paper, we aim to evaluate the possibility of extending the automatic prohibited item detection from 2D X-ray imagery to volumetric 3D CT baggage security screening imagery. To these ends, we take advantage of 3D Convolutional Neural Neworks (CNN) and popular object detection frameworks such as RetinaNet and Faster R-CNN in our work. As the first attempt to use 3D CNN for volumetric 3D CT baggage security screening, we first evaluate different CNN architectures on the classification of isolated prohibited item volumes and compare against traditional methods which use hand-crafted features. Subsequently, we evaluate object detection performance of different architectures on volumetric 3D CT baggage images. The results of our experiments on Bottle and Handgun datasets demonstrate that 3D CNN models can achieve comparable performance (98% true positive rate and 1.5% false positive rate) to traditional methods but require significantly less time for inference (0.014s per volume). Furthermore, the extended 3D object detection models achieve promising performance in detecting prohibited items within volumetric 3D CT baggage imagery with 76% mAP for bottles and 88% mAP for handguns, which shows both the challenge and promise of such threat detection within 3D CT X-ray security imagery.

  • 3 authors
·
Mar 26, 2020

Rad-JEPA 3D: Radiology Joint-Embedding Predictive Model for 3D Computed Tomography

Self-supervised pretraining is central to 3D medical image analysis, where unlabeled CT volumes are abundant but expert annotations are scarce. Yet existing volumetric encoders often fail to preserve the coarse spatial and geometric structure that downstream reasoning depends on, limiting their performance on organ disentanglement, abnormality detection, and spatial understanding when paired with language models. We introduce Rad-JEPA 3D, a joint-embedding predictive framework that learns volumetric CT representations by predicting the latent features of a complete scan from a masked view. At its core is a hybrid H-Mamba encoder that fuses a Mamba state-space branch, which models inter-slice continuity through sequential scanning, with a grouped-query attention branch, which captures cross-plane spatial context, combined through a lightweight per-token router. To improve the quality of intermediate representations, we further propose Hidden States Orthogonal Regularization (HSOR), which aligns student-teacher hidden states and reduces feature redundancy throughout the encoder. This layer-wise regularization produces more consistent and discriminative volumetric representations, leading to improved performance on organ recognition and spatial reasoning tasks. Pretrained on approximately 120,000 CT scans, Rad-JEPA 3D attains state-of-the-art results despite its compact size: with only 4.0B total parameters, it achieves competitive results with state-of-the-art on closed-ended VQA and the best average spatial-reasoning score on the Spatial-Med benchmark. Ablation studies confirm that the hybrid block and HSOR contribute complementary gains, and that the induced spatial structure can substitute for raw language-model scale on volumetric reasoning tasks.

  • 3 authors
·
Jul 27

Mediastinal lymph nodes segmentation using 3D convolutional neural network ensembles and anatomical priors guiding

As lung cancer evolves, the presence of enlarged and potentially malignant lymph nodes must be assessed to properly estimate disease progression and select the best treatment strategy. Following the clinical guidelines, estimation of short-axis diameter and mediastinum station are paramount for correct diagnosis. A method for accurate and automatic segmentation is hence decisive for quantitatively describing lymph nodes. In this study, the use of 3D convolutional neural networks, either through slab-wise schemes or the leveraging of downsampled entire volumes, is investigated. Furthermore, the potential impact from simple ensemble strategies is considered. As lymph nodes have similar attenuation values to nearby anatomical structures, we suggest using the knowledge of other organs as prior information to guide the segmentation task. To assess the segmentation and instance detection performances, a 5-fold cross-validation strategy was followed over a dataset of 120 contrast-enhanced CT volumes. For the 1178 lymph nodes with a short-axis diameter geq10 mm, our best performing approach reached a patient-wise recall of 92%, a false positive per patient ratio of 5, and a segmentation overlap of 80.5%. The method performs similarly well across all stations. Fusing a slab-wise and a full volume approach within an ensemble scheme generated the best performances. The anatomical priors guiding strategy is promising, yet a larger set than four organs appears needed to generate an optimal benefit. A larger dataset is also mandatory, given the wide range of expressions a lymph node can exhibit (i.e., shape, location, and attenuation), and contrast uptake variations.

  • 5 authors
·
Feb 11, 2021

RadGenome-Anatomy: A Large-Scale Anatomy-Labeled Chest Radiograph Dataset via Physically Grounded Volumetric Projection

Anatomical structure labels for chest radiographs are essential for medical image segmentation and a broad range of downstream diagnostic tasks. However, annotating anatomy directly on 2D chest radiographs is labor-intensive and intrinsically ambiguous, as 3D anatomical structures are projected onto a single 2D plane where boundaries may overlap, be occluded, or appear only partially visible. Consequently, existing anatomy-labeled chest radiograph datasets remain limited in scale, anatomy coverage, and label reliability. To address these limitations, we introduce RadGenome-Anatomy, the largest anatomy-labeled chest radiograph dataset, containing over 10 million segmentation masks across 210 anatomical structures in 25,692 studies. It is constructed by projecting large-scale 3D anatomical masks from CT volumes into 2D radiographic space through canonical radiographic geometry. This shifts annotation from directly tracing uncertain 2D boundaries to defining anatomy in volumetric space, where structures that overlap or become partially invisible in radiographs remain spatially separable. As a result, each 2D mask represents the physically grounded projected footprint of a volumetrically defined structure. The scale and broad anatomical coverage of RadGenome-Anatomy, including structures that are overlapping, partially visible, or difficult to delineate directly, enable research on geometric measurements as explicit evidence for chest radiograph interpretation. We demonstrate this by training XAnatomy to predict structure-specific masks and derive clinically relevant measurements, achieving diagnostic accuracies of 96.4%, 95.6%, and 89.2% for cardiomegaly, kyphosis, and scoliosis, respectively.

  • 5 authors
·
May 16

nnFoundation: 3D Foundation Models for Radiology

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

  • 83 authors
·
Sep 21

Learning Generalizable 3D Medical Image Representations from Mask-Guided Self-Supervision

Foundation models have transformed vision and language by learning general-purpose representations from large-scale unlabeled data, yet 3D medical imaging lacks analogous approaches. Existing self-supervised methods rely on low-level reconstruction or contrastive objectives that fail to capture the anatomical semantics critical for medical image analysis, limiting transfer to downstream tasks. We present MASS (MAsk-guided Self-Supervised learning), which treats in-context segmentation as the pretext task for learning general-purpose medical imaging representations. MASS's key insight is that automatically generated class-agnostic masks provide sufficient structural supervision for learning semantically rich representations. By training on thousands of diverse mask proposals spanning anatomical structures and pathological findings, MASS learns what semantically defines medical structures: the holistic combination of appearance, shape, spatial context, and anatomical relationships. We demonstrate effectiveness across data regimes: from small-scale pretraining on individual datasets (20-200 scans) to large-scale multi-modal pretraining on 5K CT, MRI, and PET volumes, all without annotations. MASS demonstrates: (i) few-shot segmentation on novel structures, (ii) matching full supervision with only 20-40\% labeled data while outperforming self-supervised baselines by over 20 in Dice score in low-data regimes, and (iii) frozen-encoder classification on unseen pathologies that matches full supervised training with thousands of samples. Mask-guided self-supervised pretraining captures broadly generalizable knowledge, opening a path toward 3D medical imaging foundation models without expert annotations. Code is available: https://github.com/Stanford-AIMI/MASS.

  • 8 authors
·
Mar 13

Better Tokens for Better 3D: Advancing Vision-Language Modeling in 3D Medical Imaging

Recent progress in vision-language modeling for 3D medical imaging has been fueled by large-scale computed tomography (CT) corpora with paired free-text reports, stronger architectures, and powerful pretrained models. This has enabled applications such as automated report generation and text-conditioned 3D image synthesis. Yet, current approaches struggle with high-resolution, long-sequence volumes: contrastive pretraining often yields vision encoders that are misaligned with clinical language, and slice-wise tokenization blurs fine anatomy, reducing diagnostic performance on downstream tasks. We introduce BTB3D (Better Tokens for Better 3D), a causal convolutional encoder-decoder that unifies 2D and 3D training and inference while producing compact, frequency-aware volumetric tokens. A three-stage training curriculum enables (i) local reconstruction, (ii) overlapping-window tiling, and (iii) long-context decoder refinement, during which the model learns from short slice excerpts yet generalizes to scans exceeding 300 slices without additional memory overhead. BTB3D sets a new state-of-the-art on two key tasks: it improves BLEU scores and increases clinical F1 by 40% over CT2Rep, CT-CHAT, and Merlin for report generation; and it reduces FID by 75% and halves FVD compared to GenerateCT and MedSyn for text-to-CT synthesis, producing anatomically consistent 512*512*241 volumes. These results confirm that precise three-dimensional tokenization, rather than larger language backbones alone, is essential for scalable vision-language modeling in 3D medical imaging. The codebase is available at: https://github.com/ibrahimethemhamamci/BTB3D

  • 10 authors
·
Oct 23, 2025

Rapid patient-specific neural networks for intraoperative X-ray to volume registration

The integration of artificial intelligence in image-guided interventions holds transformative potential, promising to extract 3D geometric and quantitative information from conventional 2D imaging modalities during complex procedures. Achieving this requires the rapid and precise alignment of 2D intraoperative images (e.g., X-ray) with 3D preoperative volumes (e.g., CT, MRI). However, current 2D/3D registration methods fail across the broad spectrum of procedures dependent on X-ray guidance: traditional optimization techniques require custom parameter tuning for each subject, whereas neural networks trained on small datasets do not generalize to new patients or require labor-intensive manual annotations, increasing clinical burden and precluding application to new anatomical targets. To address these challenges, we present xvr, a fully automated framework for training patient-specific neural networks for 2D/3D registration. xvr uses physics-based simulation to generate abundant high-quality training data from a patient's own preoperative volumetric imaging, thereby overcoming the inherently limited ability of supervised models to generalize to new patients and procedures. Furthermore, xvr requires only 5 minutes of training per patient, making it suitable for emergency interventions as well as planned procedures. We perform the largest evaluation of a 2D/3D registration algorithm on real X-ray data to date and find that xvr robustly generalizes across a diverse dataset comprising multiple anatomical structures, imaging modalities, and hospitals. Across surgical tasks, xvr achieves submillimeter-accurate registration at intraoperative speeds, improving upon existing methods by an order of magnitude. xvr is released as open-source software freely available at https://github.com/eigenvivek/xvr.

  • 8 authors
·
Mar 20, 2025

Scaling Self-Supervised and Cross-Modal Pretraining for Volumetric CT Transformers

We introduce SPECTRE, a fully transformer-based foundation model for volumetric computed tomography (CT). Our Self-Supervised & Cross-Modal Pretraining for CT Representation Extraction (SPECTRE) approach utilizes scalable 3D Vision Transformer architectures and modern self-supervised and vision-language pretraining strategies to learn general-purpose CT representations. Volumetric CT poses unique challenges, such as extreme token scaling, geometric anisotropy, and weak or noisy clinical supervision, that make standard transformer and contrastive learning recipes ineffective out of the box. The framework jointly optimizes a local transformer for high-resolution volumetric feature extraction and a global transformer for whole-scan context modeling, making large-scale 3D attention computationally tractable. Notably, SPECTRE is trained exclusively on openly available CT datasets, demonstrating that high-performing, generalizable representations can be achieved without relying on private data. Pretraining combines DINO-style self-distillation with SigLIP-based vision-language alignment using paired radiology reports, yielding features that are both geometrically consistent and clinically meaningful. Across multiple CT benchmarks, SPECTRE consistently outperforms prior CT foundation models in both zero-shot and fine-tuned settings, establishing SPECTRE as a scalable, open, and fully transformer-based foundation model for 3D medical imaging.

  • 5 authors
·
Mar 29

RadGenome-Chest CT: A Grounded Vision-Language Dataset for Chest CT Analysis

Developing generalist foundation model has recently attracted tremendous attention among researchers in the field of AI for Medicine (AI4Medicine). A pivotal insight in developing these models is their reliance on dataset scaling, which emphasizes the requirements on developing open-source medical image datasets that incorporate diverse supervision signals across various imaging modalities. In this paper, we introduce RadGenome-Chest CT, a comprehensive, large-scale, region-guided 3D chest CT interpretation dataset based on CT-RATE. Specifically, we leverage the latest powerful universal segmentation and large language models, to extend the original datasets (over 25,692 non-contrast 3D chest CT volume and reports from 20,000 patients) from the following aspects: (i) organ-level segmentation masks covering 197 categories, which provide intermediate reasoning visual clues for interpretation; (ii) 665 K multi-granularity grounded reports, where each sentence of the report is linked to the corresponding anatomical region of CT volume in the form of a segmentation mask; (iii) 1.3 M grounded VQA pairs, where questions and answers are all linked with reference segmentation masks, enabling models to associate visual evidence with textual explanations. All grounded reports and VQA pairs in the validation set have gone through manual verification to ensure dataset quality. We believe that RadGenome-Chest CT can significantly advance the development of multimodal medical foundation models, by training to generate texts based on given segmentation regions, which is unattainable with previous relevant datasets. We will release all segmentation masks, grounded reports, and VQA pairs to facilitate further research and development in this field.

  • 7 authors
·
Apr 25, 2024

Multi-Class 3D Object Detection Within Volumetric 3D Computed Tomography Baggage Security Screening Imagery

Automatic detection of prohibited objects within passenger baggage is important for aviation security. X-ray Computed Tomography (CT) based 3D imaging is widely used in airports for aviation security screening whilst prior work on automatic prohibited item detection focus primarily on 2D X-ray imagery. These works have proven the possibility of extending deep convolutional neural networks (CNN) based automatic prohibited item detection from 2D X-ray imagery to volumetric 3D CT baggage security screening imagery. However, previous work on 3D object detection in baggage security screening imagery focused on the detection of one specific type of objects (e.g., either {\it bottles} or {\it handguns}). As a result, multiple models are needed if more than one type of prohibited item is required to be detected in practice. In this paper, we consider the detection of multiple object categories of interest using one unified framework. To this end, we formulate a more challenging multi-class 3D object detection problem within 3D CT imagery and propose a viable solution (3D RetinaNet) to tackle this problem. To enhance the performance of detection we investigate a variety of strategies including data augmentation and varying backbone networks. Experimentation carried out to provide both quantitative and qualitative evaluations of the proposed approach to multi-class 3D object detection within 3D CT baggage security screening imagery. Experimental results demonstrate the combination of the 3D RetinaNet and a series of favorable strategies can achieve a mean Average Precision (mAP) of 65.3\% over five object classes (i.e. {\it bottles, handguns, binoculars, glock frames, iPods}). The overall performance is affected by the poor performance on {\it glock frames} and {\it iPods} due to the lack of data and their resemblance with the baggage clutter.

  • 3 authors
·
Aug 2, 2020

MedVista3D: Vision-Language Modeling for Reducing Diagnostic Errors in 3D CT Disease Detection, Understanding and Reporting

Radiologic diagnostic errors-under-reading errors, inattentional blindness, and communication failures-remain prevalent in clinical practice. These issues often stem from missed localized abnormalities, limited global context, and variability in report language. These challenges are amplified in 3D imaging, where clinicians must examine hundreds of slices per scan. Addressing them requires systems with precise localized detection, global volume-level reasoning, and semantically consistent natural language reporting. However, existing 3D vision-language models are unable to meet all three needs jointly, lacking local-global understanding for spatial reasoning and struggling with the variability and noise of uncurated radiology reports. We present MedVista3D, a multi-scale semantic-enriched vision-language pretraining framework for 3D CT analysis. To enable joint disease detection and holistic interpretation, MedVista3D performs local and global image-text alignment for fine-grained representation learning within full-volume context. To address report variability, we apply language model rewrites and introduce a Radiology Semantic Matching Bank for semantics-aware alignment. MedVista3D achieves state-of-the-art performance on zero-shot disease classification, report retrieval, and medical visual question answering, while transferring well to organ segmentation and prognosis prediction. Code and datasets will be released.

  • 6 authors
·
Sep 3, 2025 2

MedSyn: Text-guided Anatomy-aware Synthesis of High-Fidelity 3D CT Images

This paper introduces an innovative methodology for producing high-quality 3D lung CT images guided by textual information. While diffusion-based generative models are increasingly used in medical imaging, current state-of-the-art approaches are limited to low-resolution outputs and underutilize radiology reports' abundant information. The radiology reports can enhance the generation process by providing additional guidance and offering fine-grained control over the synthesis of images. Nevertheless, expanding text-guided generation to high-resolution 3D images poses significant memory and anatomical detail-preserving challenges. Addressing the memory issue, we introduce a hierarchical scheme that uses a modified UNet architecture. We start by synthesizing low-resolution images conditioned on the text, serving as a foundation for subsequent generators for complete volumetric data. To ensure the anatomical plausibility of the generated samples, we provide further guidance by generating vascular, airway, and lobular segmentation masks in conjunction with the CT images. The model demonstrates the capability to use textual input and segmentation tasks to generate synthesized images. The results of comparative assessments indicate that our approach exhibits superior performance compared to the most advanced models based on GAN and diffusion techniques, especially in accurately retaining crucial anatomical features such as fissure lines, airways, and vascular structures. This innovation introduces novel possibilities. This study focuses on two main objectives: (1) the development of a method for creating images based on textual prompts and anatomical components, and (2) the capability to generate new images conditioning on anatomical elements. The advancements in image generation can be applied to enhance numerous downstream tasks.

  • 5 authors
·
Oct 5, 2023

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

  • 7 authors
·
Oct 29

MedVL-SAM2: A unified 3D medical vision-language model for multimodal reasoning and prompt-driven segmentation

Recent progress in medical vision-language models (VLMs) has achieved strong performance on image-level text-centric tasks such as report generation and visual question answering (VQA). However, achieving fine-grained visual grounding and volumetric spatial reasoning in 3D medical VLMs remains challenging, particularly when aiming to unify these capabilities within a single, generalizable framework. To address this challenge, we proposed MedVL-SAM2, a unified 3D medical multimodal model that concurrently supports report generation, VQA, and multi-paradigm segmentation, including semantic, referring, and interactive segmentation. MedVL-SAM2 integrates image-level reasoning and pixel-level perception through a cohesive architecture tailored for 3D medical imaging, and incorporates a SAM2-based volumetric segmentation module to enable precise multi-granular spatial reasoning. The model is trained in a multi-stage pipeline: it is first pre-trained on a large-scale corpus of 3D CT image-text pairs to align volumetric visual features with radiology-language embeddings. It is then jointly optimized with both language-understanding and segmentation objectives using a comprehensive 3D CT segmentation dataset. This joint training enables flexible interaction via language, point, or box prompts, thereby unifying high-level visual reasoning with spatially precise localization. Our unified architecture delivers state-of-the-art performance across report generation, VQA, and multiple 3D segmentation tasks. Extensive analyses further show that the model provides reliable 3D visual grounding, controllable interactive segmentation, and robust cross-modal reasoning, demonstrating that high-level semantic reasoning and precise 3D localization can be jointly achieved within a unified 3D medical VLM.

  • 7 authors
·
Jan 14

VELVET-Med: Vision and Efficient Language Pre-training for Volumetric Imaging Tasks in Medicine

Vision-and-language models (VLMs) have been increasingly explored in the medical domain, particularly following the success of CLIP in general domain. However, unlike the relatively straightforward pairing of 2D images and text, curating large-scale paired data in the medical field for volumetric modalities such as CT scans remains a challenging and time-intensive process. This difficulty often limits the performance on downstream tasks. To address these challenges, we propose a novel vision-language pre-training (VLP) framework, termed as VELVET-Med, specifically designed for limited volumetric data such as 3D CT and associated radiology reports. Instead of relying on large-scale data collection, our method focuses on the development of effective pre-training objectives and model architectures. The key contributions are: 1) We incorporate uni-modal self-supervised learning into VLP framework, which are often underexplored in the existing literature. 2) We propose a novel language encoder, termed as TriBERT, for learning multi-level textual semantics. 3) We devise the hierarchical contrastive learning to capture multi-level vision-language correspondence. Using only 38,875 scan-report pairs, our approach seeks to uncover rich spatial and semantic relationships embedded in volumetric medical images and corresponding clinical narratives, thereby enhancing the generalization ability of the learned encoders. The resulting encoders exhibit strong transferability, achieving state-of-the-art performance across a wide range of downstream tasks, including 3D segmentation, cross-modal retrieval, visual question answering, and report generation.

  • 4 authors
·
Aug 16, 2025

NV-Reason-CT: 3D Visual Language Model for CT Analysis

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

  • 16 authors
·
Sep 22

ReXGroundingCT: A 3D Chest CT Dataset for Segmentation of Findings from Free-Text Reports

We present ReXGroundingCT, the first publicly available dataset to link free-text radiology findings with pixel-level segmentations in 3D chest CT scans that is manually annotated. While prior datasets have relied on structured labels or predefined categories, ReXGroundingCT captures the full expressiveness of clinical language represented in free text and grounds it to spatially localized 3D segmentation annotations in volumetric imaging. This addresses a critical gap in medical AI: the ability to connect complex, descriptive text, such as "3 mm nodule in the left lower lobe", to its precise anatomical location in three-dimensional space, a capability essential for grounded radiology report generation systems. The dataset comprises 3,142 non-contrast chest CT scans paired with standardized radiology reports from the CT-RATE dataset. Using a systematic three-stage pipeline, GPT-4 was used to extract positive lung and pleural findings, which were then manually segmented by expert annotators. A total of 8,028 findings across 16,301 entities were annotated, with quality control performed by board-certified radiologists. Approximately 79% of findings are focal abnormalities, while 21% are non-focal. The training set includes up to three representative segmentations per finding, while the validation and test sets contain exhaustive labels for each finding entity. ReXGroundingCT establishes a new benchmark for developing and evaluating sentence-level grounding and free-text medical segmentation models in chest CT. The dataset can be accessed at https://huggingface.co/datasets/rajpurkarlab/ReXGroundingCT.

  • 23 authors
·
Jul 29, 2025

Bridging 2D and 3D Segmentation Networks for Computation Efficient Volumetric Medical Image Segmentation: An Empirical Study of 2.5D Solutions

Recently, deep convolutional neural networks have achieved great success for medical image segmentation. However, unlike segmentation of natural images, most medical images such as MRI and CT are volumetric data. In order to make full use of volumetric information, 3D CNNs are widely used. However, 3D CNNs suffer from higher inference time and computation cost, which hinders their further clinical applications. Additionally, with the increased number of parameters, the risk of overfitting is higher, especially for medical images where data and annotations are expensive to acquire. To issue this problem, many 2.5D segmentation methods have been proposed to make use of volumetric spatial information with less computation cost. Despite these works lead to improvements on a variety of segmentation tasks, to the best of our knowledge, there has not previously been a large-scale empirical comparison of these methods. In this paper, we aim to present a review of the latest developments of 2.5D methods for volumetric medical image segmentation. Additionally, to compare the performance and effectiveness of these methods, we provide an empirical study of these methods on three representative segmentation tasks involving different modalities and targets. Our experimental results highlight that 3D CNNs may not always be the best choice. Despite all these 2.5D methods can bring performance gains to 2D baseline, not all the methods hold the benefits on different datasets. We hope the results and conclusions of our study will prove useful for the community on exploring and developing efficient volumetric medical image segmentation methods.

  • 4 authors
·
Oct 13, 2020

Cardiac-CLIP: A Vision-Language Foundation Model for 3D Cardiac CT Images

Foundation models have demonstrated remarkable potential in medical domain. However, their application to complex cardiovascular diagnostics remains underexplored. In this paper, we present Cardiac-CLIP, a multi-modal foundation model designed for 3D cardiac CT images. Cardiac-CLIP is developed through a two-stage pre-training strategy. The first stage employs a 3D masked autoencoder (MAE) to perform self-supervised representation learning from large-scale unlabeled volumetric data, enabling the visual encoder to capture rich anatomical and contextual features. In the second stage, contrastive learning is introduced to align visual and textual representations, facilitating cross-modal understanding. To support the pre-training, we collect 16641 real clinical CT scans, supplemented by 114k publicly available data. Meanwhile, we standardize free-text radiology reports into unified templates and construct the pathology vectors according to diagnostic attributes, based on which the soft-label matrix is generated to supervise the contrastive learning process. On the other hand, to comprehensively evaluate the effectiveness of Cardiac-CLIP, we collect 6,722 real-clinical data from 12 independent institutions, along with the open-source data to construct the evaluation dataset. Specifically, Cardiac-CLIP is comprehensively evaluated across multiple tasks, including cardiovascular abnormality classification, information retrieval and clinical analysis. Experimental results demonstrate that Cardiac-CLIP achieves state-of-the-art performance across various downstream tasks in both internal and external data. Particularly, Cardiac-CLIP exhibits great effectiveness in supporting complex clinical tasks such as the prospective prediction of acute coronary syndrome, which is notoriously difficult in real-world scenarios.

  • 23 authors
·
Jul 29, 2025

nnInteractive: Redefining 3D Promptable Segmentation

Accurate and efficient 3D segmentation is essential for both clinical and research applications. While foundation models like SAM have revolutionized interactive segmentation, their 2D design and domain shift limitations make them ill-suited for 3D medical images. Current adaptations address some of these challenges but remain limited, either lacking volumetric awareness, offering restricted interactivity, or supporting only a small set of structures and modalities. Usability also remains a challenge, as current tools are rarely integrated into established imaging platforms and often rely on cumbersome web-based interfaces with restricted functionality. We introduce nnInteractive, the first comprehensive 3D interactive open-set segmentation method. It supports diverse prompts-including points, scribbles, boxes, and a novel lasso prompt-while leveraging intuitive 2D interactions to generate full 3D segmentations. Trained on 120+ diverse volumetric 3D datasets (CT, MRI, PET, 3D Microscopy, etc.), nnInteractive sets a new state-of-the-art in accuracy, adaptability, and usability. Crucially, it is the first method integrated into widely used image viewers (e.g., Napari, MITK), ensuring broad accessibility for real-world clinical and research applications. Extensive benchmarking demonstrates that nnInteractive far surpasses existing methods, setting a new standard for AI-driven interactive 3D segmentation. nnInteractive is publicly available: https://github.com/MIC-DKFZ/napari-nninteractive (Napari plugin), https://www.mitk.org/MITK-nnInteractive (MITK integration), https://github.com/MIC-DKFZ/nnInteractive (Python backend).

MIC-DKFZ MIC at DKFZ
·
Mar 11, 2025

3D Medical Image Segmentation based on multi-scale MPU-Net

The high cure rate of cancer is inextricably linked to physicians' accuracy in diagnosis and treatment, therefore a model that can accomplish high-precision tumor segmentation has become a necessity in many applications of the medical industry. It can effectively lower the rate of misdiagnosis while considerably lessening the burden on clinicians. However, fully automated target organ segmentation is problematic due to the irregular stereo structure of 3D volume organs. As a basic model for this class of real applications, U-Net excels. It can learn certain global and local features, but still lacks the capacity to grasp spatial long-range relationships and contextual information at multiple scales. This paper proposes a tumor segmentation model MPU-Net for patient volume CT images, which is inspired by Transformer with a global attention mechanism. By combining image serialization with the Position Attention Module, the model attempts to comprehend deeper contextual dependencies and accomplish precise positioning. Each layer of the decoder is also equipped with a multi-scale module and a cross-attention mechanism. The capability of feature extraction and integration at different levels has been enhanced, and the hybrid loss function developed in this study can better exploit high-resolution characteristic information. Moreover, the suggested architecture is tested and evaluated on the Liver Tumor Segmentation Challenge 2017 (LiTS 2017) dataset. Compared with the benchmark model U-Net, MPU-Net shows excellent segmentation results. The dice, accuracy, precision, specificity, IOU, and MCC metrics for the best model segmentation results are 92.17%, 99.08%, 91.91%, 99.52%, 85.91%, and 91.74%, respectively. Outstanding indicators in various aspects illustrate the exceptional performance of this framework in automatic medical image segmentation.

  • 3 authors
·
Jul 11, 2023

Med-StepBench: A Hierarchical Reasoning Framework for Evaluating Hallucinations in Medical Vision-Language Models

Large vision-language models (VLMs) demonstrate strong performance in medical image understanding, but frequently generate clinically plausible yet incorrect statements, raising significant safety concerns. Existing medical hallucination benchmarks primarily focus on 2D imaging with one-shot diagnostic questions, offering limited insight into whether predictions are grounded in correct localization and abnormality identification, allowing critical reasoning errors to remain hidden behind seemingly correct diagnoses. We introduce Med-StepBench, the first large-scale benchmark for step-wise hallucination detection in 3D oncological PET/CT, comprising over 12,000 images and more than 1,000,000 image-statement pairs across volumetric and multi-view 2D data, which decomposes clinical reasoning into four expert-designed diagnostic stages. Using clinician-verified annotations, we perform the first step-level evaluation of general-purpose and medical VLMs, revealing systematic failure modes obscured by aggregate accuracy metrics. Furthermore, we show that current VLMs are highly susceptible to adversarial yet clinically plausible intermediate explanations, which significantly amplify hallucinations despite contradictory visual evidence. Together, our findings highlight fundamental limitations in grounding multi-step clinical reasoning and establish Med-StepBench as a rigorous benchmark for developing safer and more reliable medical VLMs.

  • 11 authors
·
May 10

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

  • 10 authors
·
Sep 5

Segmentation of 3D pore space from CT images using curvilinear skeleton: application to numerical simulation of microbial decomposition

Recent advances in 3D X-ray Computed Tomographic (CT) sensors have stimulated research efforts to unveil the extremely complex micro-scale processes that control the activity of soil microorganisms. Voxel-based description (up to hundreds millions voxels) of the pore space can be extracted, from grey level 3D CT scanner images, by means of simple image processing tools. Classical methods for numerical simulation of biological dynamics using mesh of voxels, such as Lattice Boltzmann Model (LBM), are too much time consuming. Thus, the use of more compact and reliable geometrical representations of pore space can drastically decrease the computational cost of the simulations. Several recent works propose basic analytic volume primitives (e.g. spheres, generalized cylinders, ellipsoids) to define a piece-wise approximation of pore space for numerical simulation of draining, diffusion and microbial decomposition. Such approaches work well but the drawback is that it generates approximation errors. In the present work, we study another alternative where pore space is described by means of geometrically relevant connected subsets of voxels (regions) computed from the curvilinear skeleton. Indeed, many works use the curvilinear skeleton (3D medial axis) for analyzing and partitioning 3D shapes within various domains (medicine, material sciences, petroleum engineering, etc.) but only a few ones in soil sciences. Within the context of soil sciences, most studies dealing with 3D medial axis focus on the determination of pore throats. Here, we segment pore space using curvilinear skeleton in order to achieve numerical simulation of microbial decomposition (including diffusion processes). We validate simulation outputs by comparison with other methods using different pore space geometrical representations (balls, voxels).

  • 6 authors
·
Sep 4, 2023

A 3D foundation model unifying CT interpretation and segmentation

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, CT models have treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, providing 3D masks as evidence. We curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

  • 17 authors
·
Nov 3

Leveraging Semantic Asymmetry for Precise Gross Tumor Volume Segmentation of Nasopharyngeal Carcinoma in Planning CT

In the radiation therapy of nasopharyngeal carcinoma (NPC), clinicians typically delineate the gross tumor volume (GTV) using non-contrast planning computed tomography to ensure accurate radiation dose delivery. However, the low contrast between tumors and adjacent normal tissues necessitates that radiation oncologists manually delineate the tumors, often relying on diagnostic MRI for guidance. % In this study, we propose a novel approach to directly segment NPC gross tumors on non-contrast planning CT images, circumventing potential registration errors when aligning MRI or MRI-derived tumor masks to planning CT. To address the low contrast issues between tumors and adjacent normal structures in planning CT, we introduce a 3D Semantic Asymmetry Tumor segmentation (SATs) method. Specifically, we posit that a healthy nasopharyngeal region is characteristically bilaterally symmetric, whereas the emergence of nasopharyngeal carcinoma disrupts this symmetry. Then, we propose a Siamese contrastive learning segmentation framework that minimizes the voxel-wise distance between original and flipped areas without tumor and encourages a larger distance between original and flipped areas with tumor. Thus, our approach enhances the sensitivity of features to semantic asymmetries. % Extensive experiments demonstrate that the proposed SATs achieves the leading NPC GTV segmentation performance in both internal and external testing, e.g., with at least 2\% absolute Dice score improvement and 12\% average distance error reduction when compared to other state-of-the-art methods in the external testing.

  • 15 authors
·
Nov 27, 2024

Cross-D Conv: Cross-Dimensional Transferable Knowledge Base via Fourier Shifting Operation

In biomedical imaging analysis, the dichotomy between 2D and 3D data presents a significant challenge. While 3D volumes offer superior real-world applicability, they are less available for each modality and not easy to train in large scale, whereas 2D samples are abundant but less comprehensive. This paper introduces the Cross-D Conv operation, a novel approach that bridges the dimensional gap by learning the phase shifting in the Fourier domain. Our method enables seamless weight transfer between 2D and 3D convolution operations, effectively facilitating cross-dimensional learning. The proposed architecture leverages the abundance of 2D training data to enhance 3D model performance, offering a practical solution to the multimodal data scarcity challenge in 3D medical model pretraining. Experimental validation on the RadImagenet (2D) and multimodal (3D) sets demonstrates that our approach achieves comparable or superior performance in feature quality assessment comparable to conventional methods. The enhanced convolution operation presents new opportunities for developing efficient classification and segmentation models in medical imaging. This work represents an advancement in cross-dimensional and multi-modal medical image analysis, offering a robust framework for utilizing 2D priors in 3D model pretraining or vice versa while maintaining computational efficiency.

  • 2 authors
·
Nov 2, 2024

Astra: a generalizable report generation foundation model for 3D computed tomography

Interpreting computed tomography (CT) requires review of hundreds of volumetric slices and remains time-intensive and expertise-dependent. Automated CT report generation offers a promising route to improving clinical efficiency, yet the field still lacks a generalizable CT report generation foundation model that supports multi-region reporting and remains robust across external real-world cohorts. Intrinsic inconsistencies in reporting style and diagnostic terminology across cohorts make naive joint training difficult. Here we present Astra, a generalizable CT report generation foundation model developed on 90,678 thoracoabdominal CT-report pairs collected from five sites worldwide (CTRgDB), comprising 353,671 abnormalities spanning eight organ systems. By harmonizing report style and further refining diagnostic consistency via reinforcement learning, Astra achieves style-consistent and diagnostically accurate report generation across diverse anatomical regions and institutions. Evaluated on CTRgDB and six external cohorts, Astra achieves state-of-the-art performance with a 38.4% average improvement in fine-grained diagnostic metrics (P<0.001). Deployed at external clinical sites without any site-specific fine-tuning, Astra accelerated chest report drafting by 29.6% and improved abdominal report completeness by 11.3% among junior and mid-level radiologists (P<0.001). Furthermore, Astra demonstrates broad utility as a foundation for CT AI development, improving downstream diagnostic performance and scaling vision-language pretrain through high-quality report synthesis. Overall, Astra serves as a broadly accessible clinical assistant and a pivotal infrastructure for the next generation of AI-powered healthcare. The code for Astra is publicly available at https://github.com/zh-Wang-Med/Astra.

  • 22 authors
·
Jul 13

IMVS: Interactive Medical Volume Segmentation with Test-Time Adaptation - A New Method for Annotating Radiology Datasets

Annotating large radiology datasets is bottlenecked by the manual effort of delineating structures slice-by-slice in 3D volumes. Interactive methods reduce this effort but stay interaction-inefficient: slice-wise methods (including many foundation models) ignore inter-slice continuity, while 3D and video-based methods propagate a prompt with a fixed propagator that never adapts to the target volume, so it drifts on low-contrast or pathological structures and must be re-prompted. We present IMVS, a human-in-the-loop annotation framework that composes three components into a closed loop rather than a new segmentation primitive: a lightweight 2D Slice Mask Adapter (SMA) fine-tuned online from user scribbles, a frozen Volume Mask Tracker (VMT) that propagates corrected masks across adjacent slices, and a soft teacher--student alignment that limits forgetting. The SMA is backbone-agnostic (UNet++, DeepLabV3, TransUNet). Across 8 public CT/MRI datasets, IMVS matches strong interactive baselines in quality while sharply cutting annotation effort: 14.4times faster than a proficient copy-based manual workflow (22.3times over naive manual), 4.6times over slice-wise and 1.9times over 3D interactive methods. MedSAM2 and ScribblePrompt stay competitive or stronger on well-delineated organs; IMVS's advantage is largest on challenging targets and on interaction efficiency. Source code and Demo Video: https://github.com/AbhilakshSinghReen/imvs.

  • 3 authors
·
Sep 14

Generative Enhancement for 3D Medical Images

The limited availability of 3D medical image datasets, due to privacy concerns and high collection or annotation costs, poses significant challenges in the field of medical imaging. While a promising alternative is the use of synthesized medical data, there are few solutions for realistic 3D medical image synthesis due to difficulties in backbone design and fewer 3D training samples compared to 2D counterparts. In this paper, we propose GEM-3D, a novel generative approach to the synthesis of 3D medical images and the enhancement of existing datasets using conditional diffusion models. Our method begins with a 2D slice, noted as the informed slice to serve the patient prior, and propagates the generation process using a 3D segmentation mask. By decomposing the 3D medical images into masks and patient prior information, GEM-3D offers a flexible yet effective solution for generating versatile 3D images from existing datasets. GEM-3D can enable dataset enhancement by combining informed slice selection and generation at random positions, along with editable mask volumes to introduce large variations in diffusion sampling. Moreover, as the informed slice contains patient-wise information, GEM-3D can also facilitate counterfactual image synthesis and dataset-level de-enhancement with desired control. Experiments on brain MRI and abdomen CT images demonstrate that GEM-3D is capable of synthesizing high-quality 3D medical images with volumetric consistency, offering a straightforward solution for dataset enhancement during inference. The code is available at https://github.com/HKU-MedAI/GEM-3D.

  • 6 authors
·
Mar 19, 2024

FleXray: Universal Clinical X-ray Segmentation

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

  • 5 authors
·
Sep 21

CADS: A Comprehensive Anatomical Dataset and Segmentation for Whole-Body Anatomy in Computed Tomography

Accurate delineation of anatomical structures in volumetric CT scans is crucial for diagnosis and treatment planning. While AI has advanced automated segmentation, current approaches typically target individual structures, creating a fragmented landscape of incompatible models with varying performance and disparate evaluation protocols. Foundational segmentation models address these limitations by providing a holistic anatomical view through a single model. Yet, robust clinical deployment demands comprehensive training data, which is lacking in existing whole-body approaches, both in terms of data heterogeneity and, more importantly, anatomical coverage. In this work, rather than pursuing incremental optimizations in model architecture, we present CADS, an open-source framework that prioritizes the systematic integration, standardization, and labeling of heterogeneous data sources for whole-body CT segmentation. At its core is a large-scale dataset of 22,022 CT volumes with complete annotations for 167 anatomical structures, representing a significant advancement in both scale and coverage, with 18 times more scans than existing collections and 60% more distinct anatomical targets. Building on this diverse dataset, we develop the CADS-model using established architectures for accessible and automated full-body CT segmentation. Through comprehensive evaluation across 18 public datasets and an independent real-world hospital cohort, we demonstrate advantages over SoTA approaches. Notably, thorough testing of the model's performance in segmentation tasks from radiation oncology validates its direct utility for clinical interventions. By making our large-scale dataset, our segmentation models, and our clinical software tool publicly available, we aim to advance robust AI solutions in radiology and make comprehensive anatomical analysis accessible to clinicians and researchers alike.

  • 33 authors
·
Jul 29, 2025

Multi-view X-ray Image Synthesis with Multiple Domain Disentanglement from CT Scans

X-ray images play a vital role in the intraoperative processes due to their high resolution and fast imaging speed and greatly promote the subsequent segmentation, registration and reconstruction. However, over-dosed X-rays superimpose potential risks to human health to some extent. Data-driven algorithms from volume scans to X-ray images are restricted by the scarcity of paired X-ray and volume data. Existing methods are mainly realized by modelling the whole X-ray imaging procedure. In this study, we propose a learning-based approach termed CT2X-GAN to synthesize the X-ray images in an end-to-end manner using the content and style disentanglement from three different image domains. Our method decouples the anatomical structure information from CT scans and style information from unpaired real X-ray images/ digital reconstructed radiography (DRR) images via a series of decoupling encoders. Additionally, we introduce a novel consistency regularization term to improve the stylistic resemblance between synthesized X-ray images and real X-ray images. Meanwhile, we also impose a supervised process by computing the similarity of computed real DRR and synthesized DRR images. We further develop a pose attention module to fully strengthen the comprehensive information in the decoupled content code from CT scans, facilitating high-quality multi-view image synthesis in the lower 2D space. Extensive experiments were conducted on the publicly available CTSpine1K dataset and achieved 97.8350, 0.0842 and 3.0938 in terms of FID, KID and defined user-scored X-ray similarity, respectively. In comparison with 3D-aware methods (pi-GAN, EG3D), CT2X-GAN is superior in improving the synthesis quality and realistic to the real X-ray images.

  • 9 authors
·
Apr 18, 2024

VoxStruct3D: Structure-Leading Flow Matching for Voxel-Space 3D MRI Synthesis

High-fidelity 3D MRI synthesis requires both globally coherent anatomy and fine-grained voxel-level detail. Although latent diffusion makes volumetric generation tractable, its image autoencoder introduces a reconstruction bottleneck that can limit the fine detail recoverable in the final volume. We present VoxStruct3D, a voxel-space flow-matching framework that directly models full-resolution MRI volumes using a clean-data prediction objective. Its Volumetric Voxel Generator (VVG) combines factorized 3D patch embedding with overlapping upsampling, time-modulated residual refinement, and skip fusion, enabling neighboring tokens to jointly reconstruct shared voxel regions and suppress patch-boundary artifacts. To complement direct voxel-space modeling with an explicit anatomical prior, we further introduce a Structure-First, Image-Follows (SFIF) strategy. A frozen pretrained 3D medical encoder and a StructVAE extract compact structure tokens that preserve dominant anatomy, while a structure-leading schedule keeps their trajectory ahead of the image trajectory. Patch-Aligned RoPE spatially aligns the unequal token grids, and asymmetric attention enforces one-way guidance from structure to image. Experiments on pathological and healthy T1-weighted brain MRI datasets show that VoxStruct3D achieves the strongest overall performance across feature-distribution alignment, sample diversity, and perceptual quality, producing anatomically coherent and visually realistic volumes.

  • 8 authors
·
Aug 4

SAM-Med3D: Towards General-purpose Segmentation Models for Volumetric Medical Images

Existing volumetric medical image segmentation models are typically task-specific, excelling at specific target but struggling to generalize across anatomical structures or modalities. This limitation restricts their broader clinical use. In this paper, we introduce SAM-Med3D for general-purpose segmentation on volumetric medical images. Given only a few 3D prompt points, SAM-Med3D can accurately segment diverse anatomical structures and lesions across various modalities. To achieve this, we gather and process a large-scale 3D medical image dataset, SA-Med3D-140K, from a blend of public sources and licensed private datasets. This dataset includes 22K 3D images and 143K corresponding 3D masks. Then SAM-Med3D, a promptable segmentation model characterized by the fully learnable 3D structure, is trained on this dataset using a two-stage procedure and exhibits impressive performance on both seen and unseen segmentation targets. We comprehensively evaluate SAM-Med3D on 16 datasets covering diverse medical scenarios, including different anatomical structures, modalities, targets, and zero-shot transferability to new/unseen tasks. The evaluation shows the efficiency and efficacy of SAM-Med3D, as well as its promising application to diverse downstream tasks as a pre-trained model. Our approach demonstrates that substantial medical resources can be utilized to develop a general-purpose medical AI for various potential applications. Our dataset, code, and models are available at https://github.com/uni-medical/SAM-Med3D.

  • 14 authors
·
Oct 23, 2023

I^3Net: Inter-Intra-slice Interpolation Network for Medical Slice Synthesis

Medical imaging is limited by acquisition time and scanning equipment. CT and MR volumes, reconstructed with thicker slices, are anisotropic with high in-plane resolution and low through-plane resolution. We reveal an intriguing phenomenon that due to the mentioned nature of data, performing slice-wise interpolation from the axial view can yield greater benefits than performing super-resolution from other views. Based on this observation, we propose an Inter-Intra-slice Interpolation Network (I^3Net), which fully explores information from high in-plane resolution and compensates for low through-plane resolution. The through-plane branch supplements the limited information contained in low through-plane resolution from high in-plane resolution and enables continual and diverse feature learning. In-plane branch transforms features to the frequency domain and enforces an equal learning opportunity for all frequency bands in a global context learning paradigm. We further propose a cross-view block to take advantage of the information from all three views online. Extensive experiments on two public datasets demonstrate the effectiveness of I^3Net, and noticeably outperforms state-of-the-art super-resolution, video frame interpolation and slice interpolation methods by a large margin. We achieve 43.90dB in PSNR, with at least 1.14dB improvement under the upscale factor of times2 on MSD dataset with faster inference. Code is available at https://github.com/DeepMed-Lab-ECNU/Medical-Image-Reconstruction.

  • 5 authors
·
May 4, 2024

CT-Flow: Orchestrating CT Interpretation Workflow with Model Context Protocol Servers

Recent advances in Large Vision-Language Models (LVLMs) have shown strong potential for multi-modal radiological reasoning, particularly in tasks like diagnostic visual question answering (VQA) and radiology report generation. However, most existing approaches for 3D CT analysis largely rely on static, single-pass inference. In practice, clinical interpretation is a dynamic, tool-mediated workflow where radiologists iteratively review slices and use measurement, radiomics, and segmentation tools to refine findings. To bridge this gap, we propose CT-Flow, an agentic framework designed for interoperable volumetric interpretation. By leveraging the Model Context Protocol (MCP), CT-Flow shifts from closed-box inference to an open, tool-aware paradigm. We curate CT-FlowBench, the first large-scale instruction-tuning benchmark tailored for 3D CT tool-use and multi-step reasoning. Built upon this, CT-Flow functions as a clinical orchestrator capable of decomposing complex natural language queries into automated tool-use sequences. Experimental evaluations on CT-FlowBench and standard 3D VQA datasets demonstrate that CT-Flow achieves state-of-the-art performance, surpassing baseline models by 41% in diagnostic accuracy and achieving a 95% success rate in autonomous tool invocation. This work provides a scalable foundation for integrating autonomous, agentic intelligence into real-world clinical radiology.

  • 7 authors
·
Feb 22

Vision Tomography: Towards Portable 3D Bidirectional Face-Skull Inference from Visual Data

Traditional computed tomography (CT) can capture paired 3D face and skull geometry, but it remains costly, fixed in location, and exposes patients to radiation. For applications such as remote diagnostics, digital healthcare, forensic identification, missing-person investigation, and archaeological analysis, there is an urgent need for a portable, safe, and accessible solution to capture 3D skull geometry. In this work, we introduce Vision Tomography (VT), a concept and framework capable of reconstructing paired 3D face-skull geometry from various visual modalities, and also enabling joint manipulation of 3D facial and skull geometry. To achieve this, we first construct a dataset of over 200 samples, where each case includes a CT-based skull, a CT-based face, and a high-fidelity textured face scan. Secondly, we propose a novel dense ray matching registration method that ensures topological consistency across face, skull, and their tissue correspondences. Building on this registration, we introduce the 3D Bidirectional Face-Skull Morphable Model (BFSM) as the foundation of Vision Tomography, which enables shape inference between the face and skull through a shared coefficient space, while also modeling tissue thickness variation to support one-to-many facial reconstructions from the same skull, reflecting individual facial changes such as age or body fat. Finally, we demonstrate the effectiveness of Vision Tomography across various forensic and medical applications, including paired 3D face-skull reconstruction from images or sketches and predicting surgical outcomes with joint face-skull editing. Extensive experiments confirm the robustness and accuracy of our method. Vision Tomography is available at https://github.com/wang-zidu/BFSM

  • 8 authors
·
Oct 26

Joint Self-Supervised Image-Volume Representation Learning with Intra-Inter Contrastive Clustering

Collecting large-scale medical datasets with fully annotated samples for training of deep networks is prohibitively expensive, especially for 3D volume data. Recent breakthroughs in self-supervised learning (SSL) offer the ability to overcome the lack of labeled training samples by learning feature representations from unlabeled data. However, most current SSL techniques in the medical field have been designed for either 2D images or 3D volumes. In practice, this restricts the capability to fully leverage unlabeled data from numerous sources, which may include both 2D and 3D data. Additionally, the use of these pre-trained networks is constrained to downstream tasks with compatible data dimensions. In this paper, we propose a novel framework for unsupervised joint learning on 2D and 3D data modalities. Given a set of 2D images or 2D slices extracted from 3D volumes, we construct an SSL task based on a 2D contrastive clustering problem for distinct classes. The 3D volumes are exploited by computing vectored embedding at each slice and then assembling a holistic feature through deformable self-attention mechanisms in Transformer, allowing incorporating long-range dependencies between slices inside 3D volumes. These holistic features are further utilized to define a novel 3D clustering agreement-based SSL task and masking embedding prediction inspired by pre-trained language models. Experiments on downstream tasks, such as 3D brain segmentation, lung nodule detection, 3D heart structures segmentation, and abnormal chest X-ray detection, demonstrate the effectiveness of our joint 2D and 3D SSL approach. We improve plain 2D Deep-ClusterV2 and SwAV by a significant margin and also surpass various modern 2D and 3D SSL approaches.

  • 10 authors
·
Dec 4, 2022

Med3D: Transfer Learning for 3D Medical Image Analysis

The performance on deep learning is significantly affected by volume of training data. Models pre-trained from massive dataset such as ImageNet become a powerful weapon for speeding up training convergence and improving accuracy. Similarly, models based on large dataset are important for the development of deep learning in 3D medical images. However, it is extremely challenging to build a sufficiently large dataset due to difficulty of data acquisition and annotation in 3D medical imaging. We aggregate the dataset from several medical challenges to build 3DSeg-8 dataset with diverse modalities, target organs, and pathologies. To extract general medical three-dimension (3D) features, we design a heterogeneous 3D network called Med3D to co-train multi-domain 3DSeg-8 so as to make a series of pre-trained models. We transfer Med3D pre-trained models to lung segmentation in LIDC dataset, pulmonary nodule classification in LIDC dataset and liver segmentation on LiTS challenge. Experiments show that the Med3D can accelerate the training convergence speed of target 3D medical tasks 2 times compared with model pre-trained on Kinetics dataset, and 10 times compared with training from scratch as well as improve accuracy ranging from 3% to 20%. Transferring our Med3D model on state-the-of-art DenseASPP segmentation network, in case of single model, we achieve 94.6\% Dice coefficient which approaches the result of top-ranged algorithms on the LiTS challenge.

  • 3 authors
·
Apr 1, 2019

Preserving Tumor Volumes for Unsupervised Medical Image Registration

Medical image registration is a critical task that estimates the spatial correspondence between pairs of images. However, current traditional and deep-learning-based methods rely on similarity measures to generate a deforming field, which often results in disproportionate volume changes in dissimilar regions, especially in tumor regions. These changes can significantly alter the tumor size and underlying anatomy, which limits the practical use of image registration in clinical diagnosis. To address this issue, we have formulated image registration with tumors as a constraint problem that preserves tumor volumes while maximizing image similarity in other normal regions. Our proposed strategy involves a two-stage process. In the first stage, we use similarity-based registration to identify potential tumor regions by their volume change, generating a soft tumor mask accordingly. In the second stage, we propose a volume-preserving registration with a novel adaptive volume-preserving loss that penalizes the change in size adaptively based on the masks calculated from the previous stage. Our approach balances image similarity and volume preservation in different regions, i.e., normal and tumor regions, by using soft tumor masks to adjust the imposition of volume-preserving loss on each one. This ensures that the tumor volume is preserved during the registration process. We have evaluated our strategy on various datasets and network architectures, demonstrating that our method successfully preserves the tumor volume while achieving comparable registration results with state-of-the-art methods. Our codes is available at: https://dddraxxx.github.io/Volume-Preserving-Registration/.

  • 5 authors
·
Sep 18, 2023

VoCo: A Simple-yet-Effective Volume Contrastive Learning Framework for 3D Medical Image Analysis

Self-Supervised Learning (SSL) has demonstrated promising results in 3D medical image analysis. However, the lack of high-level semantics in pre-training still heavily hinders the performance of downstream tasks. We observe that 3D medical images contain relatively consistent contextual position information, i.e., consistent geometric relations between different organs, which leads to a potential way for us to learn consistent semantic representations in pre-training. In this paper, we propose a simple-yet-effective Volume Contrast (VoCo) framework to leverage the contextual position priors for pre-training. Specifically, we first generate a group of base crops from different regions while enforcing feature discrepancy among them, where we employ them as class assignments of different regions. Then, we randomly crop sub-volumes and predict them belonging to which class (located at which region) by contrasting their similarity to different base crops, which can be seen as predicting contextual positions of different sub-volumes. Through this pretext task, VoCo implicitly encodes the contextual position priors into model representations without the guidance of annotations, enabling us to effectively improve the performance of downstream tasks that require high-level semantics. Extensive experimental results on six downstream tasks demonstrate the superior effectiveness of VoCo. Code will be available at https://github.com/Luffy03/VoCo.

  • 3 authors
·
Feb 27, 2024

SegBook: A Simple Baseline and Cookbook for Volumetric Medical Image Segmentation

Computed Tomography (CT) is one of the most popular modalities for medical imaging. By far, CT images have contributed to the largest publicly available datasets for volumetric medical segmentation tasks, covering full-body anatomical structures. Large amounts of full-body CT images provide the opportunity to pre-train powerful models, e.g., STU-Net pre-trained in a supervised fashion, to segment numerous anatomical structures. However, it remains unclear in which conditions these pre-trained models can be transferred to various downstream medical segmentation tasks, particularly segmenting the other modalities and diverse targets. To address this problem, a large-scale benchmark for comprehensive evaluation is crucial for finding these conditions. Thus, we collected 87 public datasets varying in modality, target, and sample size to evaluate the transfer ability of full-body CT pre-trained models. We then employed a representative model, STU-Net with multiple model scales, to conduct transfer learning across modalities and targets. Our experimental results show that (1) there may be a bottleneck effect concerning the dataset size in fine-tuning, with more improvement on both small- and large-scale datasets than medium-size ones. (2) Models pre-trained on full-body CT demonstrate effective modality transfer, adapting well to other modalities such as MRI. (3) Pre-training on the full-body CT not only supports strong performance in structure detection but also shows efficacy in lesion detection, showcasing adaptability across target tasks. We hope that this large-scale open evaluation of transfer learning can direct future research in volumetric medical image segmentation.

  • 10 authors
·
Nov 21, 2024 2

Dia-LLaMA: Towards Large Language Model-driven CT Report Generation

Medical report generation has achieved remarkable advancements yet has still been faced with several challenges. First, the inherent imbalance in the distribution of normal and abnormal cases may lead models to exhibit a biased focus on normal samples, resulting in unreliable diagnoses. Second, the frequent occurrence of common template sentences in the reports may overwhelm the critical abnormal information. Moreover, existing works focus on 2D chest X-rays, leaving CT report generation underexplored due to the high-dimensional nature of CT images and the limited availability of CT-report pairs. Recently, LLM has shown a great ability to generate reliable answers with appropriate prompts, which shed light on addressing the aforementioned challenges. In this paper, we propose Dia-LLaMA, a framework to adapt the LLaMA2-7B for CT report generation by incorporating diagnostic information as guidance prompts. Considering the high dimension of CT, we leverage a pre-trained ViT3D with perceiver to extract the visual information. To tailor the LLM for report generation and emphasize abnormality, we extract additional diagnostic information by referring to a disease prototype memory bank, which is updated during training to capture common disease representations. Furthermore, we introduce disease-aware attention to enable the model to adjust attention for different diseases. Experiments on the chest CT dataset demonstrated that our proposed method outperformed previous methods and achieved state-of-the-art on both clinical efficacy performance and natural language generation metrics. The code will be made publically available.

  • 4 authors
·
Mar 24, 2024

MVGS: Multi-view-regulated Gaussian Splatting for Novel View Synthesis

Recent works in volume rendering, e.g. NeRF and 3D Gaussian Splatting (3DGS), significantly advance the rendering quality and efficiency with the help of the learned implicit neural radiance field or 3D Gaussians. Rendering on top of an explicit representation, the vanilla 3DGS and its variants deliver real-time efficiency by optimizing the parametric model with single-view supervision per iteration during training which is adopted from NeRF. Consequently, certain views are overfitted, leading to unsatisfying appearance in novel-view synthesis and imprecise 3D geometries. To solve aforementioned problems, we propose a new 3DGS optimization method embodying four key novel contributions: 1) We transform the conventional single-view training paradigm into a multi-view training strategy. With our proposed multi-view regulation, 3D Gaussian attributes are further optimized without overfitting certain training views. As a general solution, we improve the overall accuracy in a variety of scenarios and different Gaussian variants. 2) Inspired by the benefit introduced by additional views, we further propose a cross-intrinsic guidance scheme, leading to a coarse-to-fine training procedure concerning different resolutions. 3) Built on top of our multi-view regulated training, we further propose a cross-ray densification strategy, densifying more Gaussian kernels in the ray-intersect regions from a selection of views. 4) By further investigating the densification strategy, we found that the effect of densification should be enhanced when certain views are distinct dramatically. As a solution, we propose a novel multi-view augmented densification strategy, where 3D Gaussians are encouraged to get densified to a sufficient number accordingly, resulting in improved reconstruction accuracy.

  • 3 authors
·
Oct 2, 2024 3

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

  • 11 authors
·
Oct 26

DMCVR: Morphology-Guided Diffusion Model for 3D Cardiac Volume Reconstruction

Accurate 3D cardiac reconstruction from cine magnetic resonance imaging (cMRI) is crucial for improved cardiovascular disease diagnosis and understanding of the heart's motion. However, current cardiac MRI-based reconstruction technology used in clinical settings is 2D with limited through-plane resolution, resulting in low-quality reconstructed cardiac volumes. To better reconstruct 3D cardiac volumes from sparse 2D image stacks, we propose a morphology-guided diffusion model for 3D cardiac volume reconstruction, DMCVR, that synthesizes high-resolution 2D images and corresponding 3D reconstructed volumes. Our method outperforms previous approaches by conditioning the cardiac morphology on the generative model, eliminating the time-consuming iterative optimization process of the latent code, and improving generation quality. The learned latent spaces provide global semantics, local cardiac morphology and details of each 2D cMRI slice with highly interpretable value to reconstruct 3D cardiac shape. Our experiments show that DMCVR is highly effective in several aspects, such as 2D generation and 3D reconstruction performance. With DMCVR, we can produce high-resolution 3D cardiac MRI reconstructions, surpassing current techniques. Our proposed framework has great potential for improving the accuracy of cardiac disease diagnosis and treatment planning. Code can be accessed at https://github.com/hexiaoxiao-cs/DMCVR.

  • 7 authors
·
Aug 17, 2023

TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT

Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CBCT) images. Materials and Methods: In this retrospective technical study, the dataset was assembled between 2020 and 2026 from SynthRAD challenge data, four prostate cohorts, and BIC-MAC. After registration quality control, 1450 of 1800 public challenge pairs were retained; 350 were excluded for insufficient registration quality or major source/CT mismatch. The corpus also included 84 additional prostate MRI/CT and 60 external BIC-MAC MRI/CT cases. Three 5-fold model families were evaluated with image-domain, anatomy-aware, registration-based, and uncertainty metrics. Age and sex were not consistently available across public datasets. Results: The released MRI-to-CT model achieved an overall MAE of 67.49 HU, SSIM of 0.920, and PSNR of 29.28 dB. The CBCT-to-CT model achieved an overall MAE of 53.55 HU, SSIM of 0.939, and PSNR of 32.09 dB. The unified model maintained similar performance on MRI inputs (MAE, 67.68 HU) and CBCT inputs (MAE, 54.22 HU). On external BIC-MAC data, MRI-to-CT MAE was 100.91 HU without fine-tuning and 62.21 HU after fine-tuning. Conclusion: TotalSynth provides reusable MRI- and CBCT-based CT synthesis models with broad anatomical coverage, while external evaluation highlights the need for local validation and optional fine-tuning under domain shift.

  • 6 authors
·
Sep 11

OmniCT: Towards a Unified Slice-Volume LVLM for Comprehensive CT Analysis

Computed Tomography (CT) is one of the most widely used and diagnostically information-dense imaging modalities, covering critical organs such as the heart, lungs, liver, and colon. Clinical interpretation relies on both slice-driven local features (e.g., sub-centimeter nodules, lesion boundaries) and volume-driven spatial representations (e.g., tumor infiltration, inter-organ anatomical relations). However, existing Large Vision-Language Models (LVLMs) remain fragmented in CT slice versus volumetric understanding: slice-driven LVLMs show strong generalization but lack cross-slice spatial consistency, while volume-driven LVLMs explicitly capture volumetric semantics but suffer from coarse granularity and poor compatibility with slice inputs. The absence of a unified modeling paradigm constitutes a major bottleneck for the clinical translation of medical LVLMs. We present OmniCT, a powerful unified slice-volume LVLM for CT scenarios, which makes three contributions: (i) Spatial Consistency Enhancement (SCE): volumetric slice composition combined with tri-axial positional embedding that introduces volumetric consistency, and an MoE hybrid projection enables efficient slice-volume adaptation; (ii) Organ-level Semantic Enhancement (OSE): segmentation and ROI localization explicitly align anatomical regions, emphasizing lesion- and organ-level semantics; (iii) MedEval-CT: the largest slice-volume CT dataset and hybrid benchmark integrates comprehensive metrics for unified evaluation. OmniCT consistently outperforms existing methods with a substantial margin across diverse clinical tasks and satisfies both micro-level detail sensitivity and macro-level spatial reasoning. More importantly, it establishes a new paradigm for cross-modal medical imaging understanding. Our project is available at https://github.com/ZJU4HealthCare/OmniCT.

  • 15 authors
·
Feb 17